service manual

Transcription

service manual
SERVICE MANUAL
MANUEL DE SERVICE
WEB ACCESS: http://www.yorkville.com
WORLD HEADQUARTERS
CANADA
U.S.A.
Yorkville Sound
Yorkville Sound Inc.
550 Granite Court
Pickering, Ontario
L1W-3Y8 CANADA
4625 Witmer Industrial Estate
Niagara Falls, New York
14305 USA
Voice: (905) 837-8481
Fax: (905) 837-8746
Voice: (716) 297-2920
Fax: (716) 297-3689
KW
MODEL TYPE: 100W
Quality and Innovation Since 1963
Printed in Canada
Manual-Service-100kw-00-1v4 • Feb 17, 2016
IM PORTAN T S A FE TY IN S TRU C TION S
This lightning flash with arrowhead symbol, within
an equilateral triangle, is intended to alert the user to the presence of
uninsulated “dangerous voltage” within the product’s enclosure that may be
of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilatereal triangle is intended to alert the
user to the presence of important operating and maintenance (servicing)
instructions in the literature accompanying the appliance.
Ce symbole d’éclair avec tête de flèche dans un triangle équilatéral est prévu pour alerter
l’utilisateur de la présence d’un « voltage dangereux » non-isolé à proximité de l’enceinte
du produit qui pourrait être d’ampleur suffisante pour présenter un risque de choque
IEC 60417-5041
Caution: hot surface
Attention: surface chaude
Le point d’exclamation à l’intérieur d’un triangle équilatéral est prévu pour alerter
l’utilisateur de la présence d’instructions importantes dans la littérature accompagnant
l’appareil en ce qui concerne l’opération et la maintenance de cet appareil.
S2125A
FOLLOW ALL INSTRUCTIONS
Instructions pertaining to a risk of fire, electric shock, or injury to a person
SUIVEZ TOUTES LES INSTRUCTIONS
Instructions relatives au risque de feu, choc électrique, ou blessures aux personnes
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK).
AVIS: AFIN DE REDUIRE LES RISQUE DE CHOC ELECTRIQUE, N’ENLEVEZ PAS LE COUVERT
(OU LE PANNEAU ARRIERE)
NO USER SERVICEABLE PARTS INSIDE.
NE CONTIENT AUCUNE PIECE REPARABLE PAR L’UTILISATEUR.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
CONSULTEZ UN TECHNICIEN QUALIFIE POUR L’ENTRETIENT
CE PRODUIT EST POUR L’USAGE À L’INTÉREUR SEULEMENT
THIS DEVICE IS FOR INDOOR USE ONLY!
Read Instructions: The Owner’s Manual should be read and understood before operation of your unit. Please, save these
instructions for future reference and heed all warnings.
Clean only with dry cloth.
Packaging: Keep the box and packaging materials, in case the unit needs to be returned for service.
Warning: To reduce the risk or fire or electric shock, do not expose this apparatus to rain or moisture. Do not
use this apparatus near water!
Warning: When using electric products, basic precautions should always be followed, including the following:
Power Sources
Your unit should be connected to a power source only of the voltage specified in the owners manual or as marked on the
unit. This unit has a polarized plug. Do not use with an extension cord or receptacle unless the plug can be fully inserted.
Precautions should be taken so that the grounding scheme on the unit is not defeated. An apparatus with CLASS I
construction shall be connected to a Mains socket outlet with a protective earthing ground. Where the MAINS plug or an
appliance coupler is used as the disconnect device, the disconnect device shall remain readily operable.
Hazards
Do not place this product on an unstable cart, stand, tripod, bracket or table. The product may fall, causing serious personal
injury and serious damage to the product. Use only with cart, stand, tripod, bracket, or table recommended by the
manufacturer or sold with the product. Follow the manufacturer’s instructions when installing the product and use mounting
accessories recommended by the manufacturer. Only use attachments/accessories specified by the manufacturer
Note: Prolonged use of headphones at a high volume may cause health damage on your ears.
The apparatus should not be exposed to dripping or splashing water; no objects filled with liquids should be
placed on the apparatus.
Terminals marked with the “lightning bolt” are hazardous live; the external wiring connected to these terminals require
installation by an instructed person or the use of ready made leads or cords.
Ensure that proper ventilation is provided around the appliance. Do not install near any heat sources such as radiators,
heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
No naked flame sources, such as lighted candles, should be placed on the apparatus.
Power Cord
Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the
other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your
safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. The AC supply
cord should be routed so that it is unlikely that it will be damaged. Protect the power cord from being walked on or pinched particularly
at plugs. If the AC supply cord is damaged DO NOT OPERATE THE UNIT. To completely disconnect this apparatus from the AC
Mains, disconnect the power supply cord plug from the AC receptacle. The mains plug of the power supply cord shall remain readily
operable.
Unplug this apparatus during lightning storms or when unused for long periods of time.
Service
The unit should be serviced only by qualified service personnel. Servicing is required when the apparatus has been damaged in
any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
Veuillez Lire le Manuel: Il contient des informations qui devraient êtres comprises avant l’opération de votre appareil.
Conservez. Gardez S.V.P. ces instructions pour consultations ultérieures et observez tous les avertissements.
Nettoyez seulement avec le tissu sec.
Emballage: Conservez la boite au cas ou l’appareil devait être retourner pour réparation.
Avertissement: Pour réduire le risque de feu ou la décharge électrique, n'exposez pas cet appareil à la pluie ou à l'humidité.
N’utilisez pas cet appareil près de l’eau!
Attention: Lors de l’utilisation de produits électrique, assurez-vous d’adhérer à des précautions de bases incluant celle qui suivent:
Alimentation
L’appareil ne doit être branché qu’à une source d’alimentation correspondant au voltage spécifié dans le manuel ou tel
qu’indiqué sur l’appareil. Cet appareil est équipé d’une prise d’alimentation polarisée. Ne pas utiliser cet appareil avec un
cordon de raccordement à moins qu’il soit possible d’insérer complètement les trois lames. Des précautions doivent êtres
prises afin d’eviter que le système de mise à la terre de l’appareil ne soit désengagé. Un appareil construit selon les normes
de CLASS I devrait être raccordé à une prise murale d’alimentation avec connexion intacte de mise à la masse. Lorsqu’une
prise de branchement ou un coupleur d'appareils est utilisée comme dispositif de débranchement, ce dispositif de
débranchement devra demeurer pleinement fonctionnel avec raccordement à la masse.
Risque
Ne pas placer cet appareil sur un chariot, un support, un trépied ou une table instables. L’appareil pourrait tomber et blesser
quelqu’un ou subir des dommages importants. Utiliser seulement un chariot, un support, un trépied ou une table
recommandés par le fabricant ou vendus avec le produit. Suivre les instructions du fabricant pour installer l’appareil et utiliser
les accessoires recommandés par le fabricant. Utilisez seulement les attachements/accessoires indiqués par le fabricant
Note: L'utilisation prolongée des écouteurs à un volume élevé peut avoir des conséquences néfastes sur la santé
sur vos oreilles. .
Il convient de ne pas placer sur l’appareil de sources de flammes nues, telles que des bougies allumées.
L’appeil ne doit pas être exposé à des égouttements d’eau ou des éclaboussures et qu’aucun objet rempli de liquide tel
que des vases ne doit être placé sur l’appareil.
Assurez que lappareil est fourni de la propre ventilation. Ne procédez pas à l’installation près de source de chaleur tels
que radiateurs, registre de chaleur, fours ou autres appareils (incluant les amplificateurs) qui produisent de la chaleur.
Les dispositifs marqués d’une symbole “d’éclair” sont des parties dangereuses au toucher et que les câblages
extérieurs connectés à ces dispositifs de connection extérieure doivent être effectivés par un opérateur formé ou en
utilisant des cordons déjà préparés.
Cordon d’Alimentation
Ne pas enlever le dispositif de sécurité sur la prise polarisée ou la prise avec tige de mise à la masse du cordon d’alimentation.
Une prise polarisée dispose de deux lames dont une plus large que l’autre. Une prise avec tige de mise à la masse dispose de
deux lames en plus d’une troisième tige qui connecte à la masse. La lame plus large ou la tige de mise à la masse est prévu
pour votre sécurité. La prise murale est désuète si elle n’est pas conçue pour accepter ce type de prise avec dispositif de
sécurité. Dans ce cas, contactez un électricien pour faire remplacer la prise murale. Évitez d’endommager le cordon
d’alimentation. Protégez le cordon d’alimentation. Assurez-vous qu’on ne marche pas dessus et qu’on ne le pince pas en
particulier aux prises. N’UTILISEZ PAS L’APPAREIL si le cordon d’alimentation est endommagé. Pour débrancher
complètement cet appareil de l’alimentation CA principale, déconnectez le cordon d’alimentation de la prise d’alimentation
murale. Le cordon d’alimentation du bloc d’alimentation de l’appareil doit demeurer pleinement fonctionnel.
Débranchez cet appareil durant les orages ou si inutilisé pendant de longues périodes.
Service
Consultez un technicien qualifié pour l’entretien de votre appareil. L'entretien est nécessaire quand l'appareil a été endommagé de
quelque façon que se soit. Par exemple si le cordon d’alimentation ou la prise du cordon sont endommagés, si il y a eu du liquide
qui a été renversé à l’intérieur ou des objets sont tombés dans l'appareil, si l'appareil a été exposé à la pluie ou à l'humidité, si il ne
fonctionne pas normalement, ou a été échappé.
IMP ORTA N T S A FE TY IN S TRU C TION S (U L60065)
The Lightning Flash with arrowhead symbol within an equilateral triangle, is intended to alert the user to the presence of uninsulated
"dangerous voltage" within the product enclosure that may be of sufficient magnitude to constitute a risk of shock to persons
Le symbole représentant un éclair avec une flèche à l’intérieur d’un triangle équilatéral est utilisé pour prévenir l’utilisateur de la
présence d’une tension électrique dangereuse non isolée à l’intérieur de l’appareil. Cette tension est d’un niveau suffisamment
élevé pour représenter un risque d’électrocution
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance
(servicing) instructions in the literature accompanying the product
Le symbole représentant un point d’exclamation à l’intérieur d’un triangle équilatéral, signale à l’utilisateur la présence d’instructions
importantes relatives au fonctionnement et à l’entretien de l’appareil dans cette notice d’installation
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A
grounding type plug has two blades and a third grounding prong. The wide blade or the third prongs are provided for your safety. If the provided
plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit
from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution
when moving the cart/apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as
power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or
moisture, does not operate normally, or has been dropped.
1. Lisez ces instructions.
2. Conservez ces instructions.
3. Respecter tous les avertissements.
4. Suivez toutes les instructions.
5. N'utilisez pas l'appareil près de l'eau.
6. Nettoyer uniquement avec chiffon sec.
7. Ne bloquez pas les ouvertures de ventilation. Installer en suivant les instructions du fabricant.
8. Ne pas installer près des sources de chaleur telles que radiateurs, bouches de chaleur, four ou autres appareils (y compris les amplificateurs)
produisant de la chaleur.
9. N'annulez pas l'objectif sécuritaire de la fiche polarisée ou de la tige de mise à la terre. Une fiche polarisée possède deux lames avec une plus
large que l'autre. Une prise avec mise à la terre possède deux lames et une troisième tige. La lame large ou la troisième tige sont fournis pour
votre sécurité. Si la fiche n'entre pas dans votre prise, consultez un électricien pour remplacer la prise obsolète.
10. Protéger le cordon d'alimentation des piétinements ou pincements en particulier près des fiches, des prises de courant et au point de
sortie de l'appareil.
11. Utilisez uniquement les accessoires spécifiés par le fabricant.
12. Utiliser uniquement avec un charriot, stand, trépied ou une table spécifiée par le fabricant, ou vendus avec l'appareil.
13. Débranchez l'appareil durant un orage ou lorsqu'il reste inutilisé pendant de longues périodes de temps.
14. Confiez toute réparation à un technicien qualifié. Une réparation est nécessaire lorsque l'appareil a été endommagé de quelque façon que ce
soit; comme lorsque le cordon d'alimentation ou la fiche est endommagé, lorsque du liquide a été renversé ou des objets sont tombés à l'intérieur,
lorsque l'appareil a été exposé à la pluie ou l'humidité, ne fonctionne pas normalement, ou est tombé.
WARNING:
• To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture and objects filled with liquids, such as vases, should not be
placed on this apparatus.
• To completely disconnect this apparatus from the ac mains, disconnect the power supply cord plug from the ac receptacle.
• The mains plug of the power supply cord or appliance coupler shall remain readily accessible.
AVERTISSEMENT:
• Pour réduire les risques d'incendie ou de choc électrique, ne pas exposer cet appareil à la pluie ou à l'humidité et ne placez pas d’objets contenant
des liquides, tels que des vases, sur l’appareil.
• Pour isoler totalement cet appareil de l'alimentation secteur, débranchez totalement son cordon d'alimentation du réceptacle CA.
• La prise du cordon d’alimentation ou du prolongateur, si vous en utilisez un comme dispositif de débranchement, doit rester facilement accessible
CAUTION
TO PREVENT ELECTRIC SHOCK HAZARD,
DO NOT CONNECT TO MAINS POWER SUPPLY
WHILE GRILLE IS REMOVED.
AVIS
POUR PRÉVENIR LES RISQUES D'ÉLECTROCUTION,
NE PAS RACCORDER A L’ALIMENTATION ÉLECTRIQUE ALORS
QUE LA GRILLE EST RETIRÉE.
_safety-5v0+UL60065-00-1v0 • October 28/2014
CHANNEL1
4
5
BAL
LINE IN
MIC
6
3
4
7
2
1
5
9
LINE IN
CD / LINE
1
12
15
10
3
6
9
9
0
3
6
8
KW
HIGH
LOW
3
7
2
10
BAL
6
3
8
0
CHANNEL 2
15
3
6
6
9
9
12
12
BAL
9
15
12
15
EFX SEND
MODEL TYPE: 100W
230V
50Hz 0,5A
POWER
EFX RTN
PHONES
A-Z349R / 3v90
Yorkville
120VAC
60Hz 1.0A
KW
DESIGNED & MANUFACTURED BY
YORKVILLE SOUND • Toronto, CANADA
Specifications
Power @ min. impedance (Watts)
Minimum Impedance (ohms)
Burst Power - 2 cycle
100
4
115 Watts
Speaker Configuration - LF (Size / Power)
12 inch / 100 Watts
Speaker Configuration - HF (Size / Power)
1 inch / 30 Watts
Input Channels
Channel 1 - inputs
Channel 1 - controls
Channel 2 - inputs
2
XLR, 1/4 inch TRS
Volume
2x 1/4 inch TRS, RCA
Channel 2 - controls
Volume
Main Tone Controls
Low, High
Input Sensitivity (mV)
Line Out (type / configuration)
Line Out Sensitivity (Vrms)
Effects Loop / Location
Effects Return Sensitivity (Vrms)
LED Indicators
Limiter / Switchable
Headphone Jack
ch. 1 XLR=3 Phone=10, ch.2 Phone=75 RCA=150
1/4 inch / Front (Effects Send)
1
Yes / Front
1
Power
Yes / No
Yes
Dimensions (DWH, inches)
19 x 17 x 19
Dimensions (DWH, cm)
48 x 43 x 48
Weight (lbs / kg)
39 / 17.7
100KW Parts List 1/27/2016
YS #
1310
2406
2415
3414
3428
3460
3498
3563
3660
3698
3810
4124
4418
4420
4599
4618
4639
4671
4673
4692
4729
4734
4799
4803
4809
4815
4817
4823
4824
4825
4826
4827
4829
4832
4833
4838
4844
4847
4849
4856
4857
4867
4868
4869
4980
5113
5119
5223
5226
5233
5255
5257
5259
5260
5265
5314
5406
5408
5410
5420
5422
5424
5621
5627
5834
5841
5879
5887
5925
5961
6119
6123
6150
6408
6435
6438
6451
6745
6774
6802
Description
XFMR:AM100/100KB/100KW
_1.6 AMP SLO-BLO .25X1.25 FUSE
_5.0 AMP FAST-BLO .25X1.25 FUSE
INTERNATIONAL PC MOUNT FUSEHOLDER
8' 3/18 SJT AC LINE CORD REMOVABLE
RCA DUAL PCB MT VERT GOLD .475"
1/4" JCK PCB MT HORZ
TRANSISTOR MOUNTING BRACKET
XLR FEML PCB MT HORZ
SPST ROKR SW QUIK 180" AC PWR BL/BL
4" NYLON CABLE TIE
SILPAD 1500ST 1.100 X0.820 BERQUIST
_10K 5C R/A 9MM HORIZONTAL P28
_50K B LIN 9MM HORIZONTAL P28
22AWG SOLID SC WIR
T&R JMP
W500 22R 5%
T&R RES
W250 4K99 1%
T&R RES
W500 560R 5%
T&R RES
W500 680R 5%
T&R RES
5W00 100R 5%
BLK RES
5W00 0R27 5%
BLK RES
5W00 3R9 5%
BLK RES
W250 562R 1%
T&R RES
W250 49K9 1%
T&R RES
W250 10M 5%
T&R RES
W250 12R 5%
T&R RES
W250 47R 5%
T&R RES
W250 1K 5%
T&R RES
W250 1K5 5%
T&R RES
W250 1K8 5%
T&R RES
W250 3K3 5%
T&R RES
W250 4K7 5%
T&R RES
W250 10K 5%
T&R RES
W250 22K 5%
T&R RES
W250 27K 5%
T&R RES
W250 100K 5%
T&R RES
W250 1M 5%
T&R RES
W250 2K2 5%
T&R RES
W250 180K 5%
T&R RES
W250 12K 5%
T&R RES
W250 220R 5%
T&R RES
W250 270R 5%
T&R RES
W250 36K 5%
T&R RES
W250 750R 5%
T&R RES
W250 470R 5%MINI
T&R RES
MPSA42
TO92 NPN TRAN T&R TA
J111
TO92 NCH JFET T&R TC
_39N 100V 10%CAP T&R RAD .2FLM
_68N 100V 5%CAP T&R RAD .2FLM
330N 63V 5%CAP T&R RAD .2FLM
__1U 63V 20%CAP T&R RAD .2EL
__2U2 63V 20%CAP T&R RAD .2EL
__4U7 63V 20%CAP T&R RAD .2
_22U 50V 20%CAP T&R RAD .2EL
_68U 25V 20%CAP T&R RAD .2EL
100N 50V 10%CAP T&R BEAD
X7R
_33P 50V 10%CAP BLK BEAD
NPO
_47P 100V 10%CAP T&R BEAD
NPO
100P 100V 10%CAP T&R BEAD
NPO
680P 50V 10%CAP T&R BEAD
NPO
__1N 50V 10%CAP T&R BEAD
NPO
__1N5 50V 10%CAP T&R BEAD
Y5P
470U 63V 20%CAP BLK 12X25MM EL
_47U 10V 20%CAP BLK RAD
NP
_10N 630V 10%CAP BLK RAD POLY FLM
_47N 250V 10%CAP RAD POLYFILM BULK
100U 16V 20%CAP T&R 8X7MM .2EL
2200U 50V 20%CAP BLK 18X27MM EL
__1U5 250DC10%CAP BLK RAD POLYE FLM
_33U 16V 20%CAP T&R RAD .2IN NP
W250 47K 5%MINI
T&R RES
W250 20K0 1%MINI MF
T&R RES
W250 301R 1%MINI MF
T&R RES
GRN 3MM LED 2V2 20MA DIFFUSD
_22N 275V 20%CAP BLK 'X2' 15MM AC
1N4007 1000V 1A0 DIODE
T&R
__4N7 250V 20%CAP BLK 'Y' 10MM AC
LM13600N IC XCONDUCTANCE AMP
BD139
TO126 NPN TRAN
TG
MJH11017(23) TO218 PNP TRAN DARL TI
Qty.
1
1
2
6
1
1
6
1
1
1
4
2
2
2
44
1
4
6
3
1
2
1
2
2
2
2
1
1
1
2
2
8
9
3
1
1
4
3
1
1
4
1
1
1
6
8
1
2
1
1
1
2
2
2
1
12
1
1
3
2
3
1
2
1
1
1
1
2
1
1
9
2
1
1
1
2
1
1
1
2
YS #
6822
6824
6825
6827
6882
7288
8458
8468
8547
8641
8886
8241D
N252XN
Description
1N4745A 16V0 1W0 ZENER 5% T&R
1N5246B 16V0 0W5 ZENER 5% T&R
1N4148 75V 0A45 DIODE
T&R
1N5402 200V 3A0 DIODE
TL072CP IC FET DUAL OP AMP
12" 4R 100WPGM SPEAKER
10.5" STRAP HANDLE, PLASTIC ENDCAPS
VELCRO STRAP 3/4"X22CM (VELSTRAP)
PLASTIC FOOT BLACK, POLYETHYLENE
KNOB AM SERIES AQUA
NEOPRENE N252 DRIVER GASKET
"Y" LOGO ACOUSTIC SERIES SML. DOMED
_8R 30W 1.00" DRIVER N252XN RCF
Qty.
2
4
6
4
4
1
1
1
8
4
1
1
1
YS #
Description
Qty.
M579 Parts Reference List 2/17/2016
REF
C1
C2
C3
C4
C5
C6
C7
C8
C9
C10
C11
C12
C13
C14
C25
C26
C27
C28
C29
C30
C31
C32
C33
C34
C36
C37
C38
C47
C49
C101
C102
CA1
CA2
CA3
CA4
CA5
CA6
CA7
CA8
CA9
CA10
CL1
CL2
CL3
CL4
CL5
CL6
CL7
CL8
CL10
D1
D2
D3
D4
D6
D7
D8
DL1
DL4
DL5
DL6
DL7
F1
F2
F3
JB1
JB2
JB3
JB4
JB5
JB6
JB7
JB8
LED1
P1
P2
P3
P4
QA1
QA2
YS #
5410
5314
5314
5422
5422
5961
5879
5402
5259
5314
5422
5410
5402
5841
5887
5887
5621
5621
5255
6451
5267
6435
5314
5314
5314
5307
5307
5314
5314
5257
5410
5420
5265
5314
5420
5925
5260
5259
5834
5402
5406
5226
5260
5314
5314
5314
5233
5627
5424
5408
6827
6827
6827
6827
6438
6438
6825
6825
6425
6825
6425
6425
3414
3414
3414
3498
3660
3498
3498
3460
3498
3450
3450
6408
4418
4418
4420
4420
6779
5101
Description
100P 100V 10%CAP T&R BEAD
NPO
100N 50V 10%CAP T&R BEAD
X7R
100N 50V 10%CAP T&R BEAD
X7R
1N 50V 10%CAP T&R BEAD
NPO
1N 50V 10%CAP T&R BEAD
NPO
33U 16V 20%CAP T&R RAD .2inNP
100U 16V 20%CAP T&R 8X7MM .2inEL
15P 100V 10%CAP T&R BEAD
NPO
4U7 63V 20%CAP T&R RAD .2inEL
100N 50V 10%CAP T&R BEAD
X7R
1N 50V 10%CAP T&R BEAD
NPO
100P 100V 10%CAP T&R BEAD
NPO
15P 100V 10%CAP T&R BEAD
NPO
47N 250V 10%CAP BLK RAD POLY FLM
2200U 50V 20%CAP BLK 18X27MM EL
2200U 50V 20%CAP BLK 18X27MM EL
470U 63V 20%CAP BLK 12X25MM EL
470U 63V 20%CAP BLK 12X25MM EL
1U 63V 20%CAP T&R RAD .2inEL
4N7 250V 20%CAP BLK 'Y' 10MM AC
100U 25V 20%CAP T&R RAD .2inEL
22N 275V 20%CAP BLK 'X2' 15MM AC
100N 50V 10%CAP T&R BEAD
X7R
100N 50V 10%CAP T&R BEAD
X7R
100N 50V 10%CAP T&R BEAD
X7R
39N 50V 10%CAP T&R BEAD
X7R
39N 50V 10%CAP T&R BEAD
X7R
100N 50V 10%CAP T&R BEAD
X7R
100N 50V 10%CAP T&R BEAD
X7R
2U2 63V 20%CAP T&R RAD .2inEL
100P 100V 10%CAP T&R BEAD
NPO
680P 50V 10%CAP T&R BEAD
NPO
68U 25V 20%CAP T&R RAD .2inEL
100N 50V 10%CAP T&R BEAD
X7R
680P 50V 10%CAP T&R BEAD
NPO
1U5 100V 10%CAP BLK RAD POLY FLM
22U 50V 20%CAP T&R RAD .2inEL
4U7 63V 20%CAP T&R RAD .2inEL
10N 400V 10%CAP BLK RAD POLY FLM
15P 100V 10%CAP T&R BEAD
NPO
33P 50V 10%CAP BLK BEAD
NPO
68N 100V 5%CAP T&R RAD .2inFLM
22U 50V 20%CAP T&R RAD .2inEL
100N 50V 10%CAP T&R BEAD
X7R
100N 50V 10%CAP T&R BEAD
X7R
100N 50V 10%CAP T&R BEAD
X7R
330N 63V 5%CAP T&R RAD .2inFLM
47U 10V 20%CAP BLK RAD
NP
1N5 50V 10%CAP T&R BEAD
Y5P
47P 100V 10%CAP T&R BEAD
NPO
1N5402 200V 3A0 DIODE
1N5402 200V 3A0 DIODE
1N5402 200V 3A0 DIODE
1N5402 200V 3A0 DIODE
1N4007 1000V 1A0 DIODE
T&R
1N4007 1000V 1A0 DIODE
T&R
1N4148 75V 0A45 DIODE
T&R
1N4148 75V 0A45 DIODE
T&R
BAV21 200V 0A25 DIODE
T&R
1N4148 75V 0A45 DIODE
T&R
BAV21 200V 0A25 DIODE
T&R
BAV21 200V 0A25 DIODE
T&R
INTERNATIONAL PC MOUNT FUSEHOLDER
INTERNATIONAL PC MOUNT FUSEHOLDER
INTERNATIONAL PC MOUNT FUSEHOLDER
1/4in JCK PCB MT HORZ
XLR FEML PCB MT HORZ
1/4in JCK PCB MT HORZ
1/4in JCK PCB MT HORZ
RCA DUAL PCB MT VERT GOLD .475
1/4in JCK PCB MT HORZ
1/4in JCK PCB MT HORZ GOLD TRS
1/4in JCK PCB MT HORZ GOLD TRS
GRN 3MM LED 1V9 5MA FROSTED
_10K 5C R/A 9MM HORIZONTAL P28
_10K 5C R/A 9MM HORIZONTAL P28
_50K B LIN 9MM HORIZONTAL P28
_50K B LIN 9MM HORIZONTAL P28
MJH11018 TO218 NPN TRAN DARL TI
BC550C
TO92 NPN TRAN T&R TB
REF
QA4
QA5
QA6
QA7
QL1
QL2
QL3
QL4
QL5
R1
R2
R3
R4
R5
R6
R7
R8
R9
R10
R11
R14
R15
R31
R35
R37
R39
R40
R41
R42
R43
R44
R45
R46
R47
R48
R49
R50
R51
R52
R54
R55
R70
R71
R72
R73
R75
R76
R77
R88
R89
R90
R101
R102
RA1
RA2
RA3
RA4
RA5
RA6
RA7
RA8
RA9
RA10
RA11
RA12
RA13
RA14
RA15
RA16
RA18
RA19
RA20
RL1
RL2
RL3
RL4
RL5
RL6
RL7
RL8
YS #
6774
5102
5102
5119
5104
5104
5104
5113
5104
4980
4980
4639
4639
4799
4799
4639
4639
6150
4849
4827
4834
4834
4692
4825
4673
4671
4847
4829
4844
4856
4834
4827
4827
4834
4847
6119
6119
4821
4980
4827
4827
4933
4933
6123
6123
4671
4671
4673
4671
4671
4671
4803
4803
4815
4832
4867
4869
4833
4868
4826
4826
4815
4817
4847
4825
4824
4834
4618
4838
4729
4729
4734
4673
4827
4829
4829
4857
4857
4829
4829
Description
BD139
TO126 NPN TRAN
TG
BC560C
TO92 PNP TRAN T&R TB
BC560C
TO92 PNP TRAN T&R TB
J111
TO92 NCH JFET T&R TC
MPSA56
TO92 PNP TRAN T&R TA
MPSA56
TO92 PNP TRAN T&R TA
MPSA56
TO92 PNP TRAN T&R TA
MPSA42
TO92 NPN TRAN T&R TA
MPSA56
TO92 PNP TRAN T&R TA
W250 470R 5%MINI
T&R RES
W250 470R 5%MINI
T&R RES
W250 4K99 1%
T&R RES
W250 4K99 1%
T&R RES
W250 562R 1%
T&R RES
W250 562R 1%
T&R RES
W250 4K99 1%
T&R RES
W250 4K99 1%
T&R RES
W250 301R 1%MINI MF
T&R RES
W250 180K 5%
T&R RES
W250 4K7 5%
T&R RES
W250 47K 5%
T&R RES
W250 47K 5%
T&R RES
5W00 100R 5%
BLK RES
W250 1K8 5%
T&R RES
W500 680R 5%
T&R RES
W500 560R 5%
T&R RES
W250 2K2 5%
T&R RES
W250 10K 5%
T&R RES
W250 1M 5%
T&R RES
W250 12K 5%
T&R RES
W250 47K 5%
T&R RES
W250 4K7 5%
T&R RES
W250 4K7 5%
T&R RES
W250 47K 5%
T&R RES
W250 2K2 5%
T&R RES
W250 47K 5%MINI
T&R RES
W250 47K 5%MINI
T&R RES
W250 470R 5%
T&R RES
W250 470R 5%MINI
T&R RES
W250 4K7 5%
T&R RES
W250 4K7 5%
T&R RES
W250 470R 5% .2inU
T&R RES
W250 470R 5% .2inU
T&R RES
W250 20K0 1%MINI MF
T&R RES
W250 20K0 1%MINI MF
T&R RES
W500 560R 5%
T&R RES
W500 560R 5%
T&R RES
W500 680R 5%
T&R RES
W500 560R 5%
T&R RES
W500 560R 5%
T&R RES
W500 560R 5%
T&R RES
W250 49K9 1%
T&R RES
W250 49K9 1%
T&R RES
W250 12R 5%
T&R RES
W250 22K 5%
T&R RES
W250 270R 5%
T&R RES
W250 750R 5%
T&R RES
W250 27K 5%
T&R RES
W250 36K 5%
T&R RES
W250 3K3 5%
T&R RES
W250 3K3 5%
T&R RES
W250 12R 5%
T&R RES
W250 47R 5%
T&R RES
W250 2K2 5%
T&R RES
W250 1K8 5%
T&R RES
W250 1K5 5%
T&R RES
W250 47K 5%
T&R RES
W500 22R 5%
T&R RES
W250 100K 5%
T&R RES
5W00 0R27 5%
BLK RES
5W00 0R27 5%
BLK RES
5W00 3R9 5%
BLK RES
W500 680R 5%
T&R RES
W250 4K7 5%
T&R RES
W250 10K 5%
T&R RES
W250 10K 5%
T&R RES
W250 220R 5%
T&R RES
W250 220R 5%
T&R RES
W250 10K 5%
T&R RES
W250 10K 5%
T&R RES
REF
RL10
RL11
RL12
RL13
RL14
RL15
RL16
RL17
RL18
RL19
RL20
RL21
RL22
RL23
RL24
RL25
RL26
U1
U2
U3
U4
U5
ZD2
ZD3
ZD4
ZDL1
ZDL2
ZDL3
YS #
4829
4834
4829
4829
4857
4857
4809
4834
4823
4844
4844
4829
4827
4832
4827
4832
4844
6882
6840
6882
6882
6745
6822
6822
6463
6824
6461
6461
Description
W250 10K 5%
T&R RES
W250 47K 5%
T&R RES
W250 10K 5%
T&R RES
W250 10K 5%
T&R RES
W250 220R 5%
T&R RES
W250 220R 5%
T&R RES
W250 10M 5%
T&R RES
W250 47K 5%
T&R RES
W250 1K 5%
T&R RES
W250 1M 5%
T&R RES
W250 1M 5%
T&R RES
W250 10K 5%
T&R RES
W250 4K7 5%
T&R RES
W250 22K 5%
T&R RES
W250 4K7 5%
T&R RES
W250 22K 5%
T&R RES
W250 1M 5%
T&R RES
TL072
IC FET DUAL OP AMP
MC33078P IC DUAL OP AMP
TL072
IC FET DUAL OP AMP
TL072
IC FET DUAL OP AMP
LM13600N IC XCONDUCTANCE AMP
1N4745A 16V0 1W0 ZENER 5% T&R
1N4745A 16V0 1W0 ZENER 5% T&R
1N5251BRL 22V0 0W5 ZENER 5% T&R
1N5246B 16V0 0W5 ZENER 5% T&R
1N5240BRL 10V0 0W5 ZENER 5% T&R
1N5240BRL 10V0 0W5 ZENER 5% T&R
JB2
22V/.5W
1N5251
ZD4
2
5
4K99
R
T
4
6
562R
2
RCA
3
U2
1
33U
C6
1/2
R6
J5A
4K99
R10
+16V
180K
16V
6
33078
R8
7
5
U2
1/2
4K99
C5
1N
CL3
C2
C33
C47
100N
100N
100N
100N
CL4
C3
C34
C36
100N
100N
100N
100N
400V
230Vac
50Hz
C32 100n
-16V
SECONDARY FUSES
FOR EXPORT ARE
F5A
SG
SG
F1
250V
120Vac
60Hz
400V
C32
22n
#1310
47K
47K
R71
J5B
CHANNEL 2
INPUT
470R
R1
1
3
5
JB3 S
LINE
NO_GOLD 2
R
T
470R
R2
4
6
470R
SW1
R102
R43
R44
49K9
12K
47K
20K0
1
3
U1
1/2
R70
75mVrms
NO_GOLD 2
LINE
JB4 S
4
6
R
T
1
3
2U2
C101
16V
R45
4K7
B P3
20K0
P1
10K
49K9
C1
100P
R46
CW
47K
5B
VOLUME2
R11
6
4K7
5
7
C11
1N
TREBLE
B P4
U1
1/2
R48
2
2K2
3
0.5W
16V/.5W
1N5246 RL2
ZDL1
RL1
680R
DL1
4K7
RL3
10K
STYLE
"P28"
10K
CL2
10V
22U
RL5
13
220R
15
RL6
14
AG
CL1
50V
68N
PIN OUTS
MJH11017
MJH11018
AG
RL9
10K
10M
16
1/2
LM13600
C37
39N
IABC
D
R55
C49
100N
4K7
5
47K
47K
CL10
7
1M
RL26
CL8
1N5
HIGH FREQUENCY LIMITER
QL2
MPSA56
RL22
+16V
B C E
BAV21
10V/.5W
1N5240
ZDL3
DL6
BD139
RL25
BAV21 22K
MPSA56
DL4
BC550C
BC560C
CBE
MODEL(S):# DATE
1
2
3
4
5
6
7
8
9
10
FEB/2000
MAR/23/00
MAY/02/00
SEP/04/02
SEP/13/02
AUG/14/06
.
APR/28/08
D
JUN/29/10
OCT/08/15
2N5638
DSG
1M
RL19
BAV21
MPSA56
QL3
RL24
AG
CA6
16V
22U
CLIPPING LIMITER
RL12
4K7
RL16
10K
+16V
10M
22K
RL23
2
RL13
47U
CL7
10V
RL15
4
220R
2
RL14
3
RL21
10K
1
1/2
LM13600
IABC
D
M579.SCH_DATABASE_HISTORY
100KW-100KWCE
VER# DESCRIPTION OF CHANGE
AG
AG
1.00
1.0P3
1.00
1.10
1.20
1.30
.
1.40
V
DERIVED_FROM_M517
ADD_C14_R48_1K-2K2
C32_FOR_CE_22N->100N_PT#5242
PC#6564_RA4_680R->750R
ADD_AC_SKT
PC#7150, REPLACE C37 AND C38 #5307 WITH #5223
HAND INSERTED
PC#7488, REPLACE R9 120R WITH 300R 1/4W #4798
REPLACE C12 15P with 100P #5410
PC#8129_Change resistor values.PT
5.00
Double Sided pcb added AI tabs TC/MP
(6=-16V,11=+16V)
5
7
1
2
3
4
5
6
7
8
9
10
P1
P2
P3
P4
D
D
D
D
D
D
M579.PCB_POT_LIST
100W/100WS
FUNCTION
GAIN-2
GAIN-1
BASS
TREBLE
F
F
F
F
F
F
PART#
#4403
#4409
#4406
#4406
N
N
N
N
N
N
100N
8
FETCTL
KNOB
#8641
.
.
.
K
K
K
K
K
K
AS_OF
FEB/2000
.
.
.
D
D
D
D
D
D
RA16
100K
AG
AG
RA8
3K3
R35
RA11
2K2
CL6
330N 16V
5
3
1
T
R
S JB6
6
4
EFX_SEND
2 NO_GOLD
5
3
1
T
R
S JB7
6
4
1Vrms
1Vrms
EFX_RTN
2 GOLD_T
SG
680P
RA7
3K3
RA4
750R
RA5
27K
RA3
270R
RA6
36K
QA2
BC550C
MJH11018
QA1
12R
TP1
CA3
TP2
CA9
RA9
15P
QA4
BD139
CUT OUT RA5, RA6 UNTIL
18 TO 22 mV IS ACROSS
TP1 AND TP2 WITH AMP COLD
RA10
47R
5
RA1
100N
NOTE:
ALL UNMARKED DIODES ARE 1N4148
AC VOLTAGES MEASURED AT 1KHz WITH
VOLUMES AT 10, TONES AT 0
YORKVILLE
R51
470R
AG
CA1
47K
CA10
33p
RA13
1K5
CA7
10V
4U7
AG
QA6
U5
2N5638
QA7
MODEL(S):# REF
CL5
RL10
10K
PIN 11
1K8
+38VDC
CA2
QA5
25V
BC560
68U
RA14
U4
1/2
220R
-38VDC
RA12
1K8
BC560
1
TLO72
10K
22K
AG
3
4K7
RL18
1K
DL5
RL20
1M
10V/.5W
1N5240
ZDL2
AG
QL5
DL7
QL4
MPSA43
E CB
47K
RL17
AG
LD1
47P
RA2
+38VDC
0.5W
560R
SG
U4
9
-16V
0.5W
560R
TLO72
1/2
10
7
U3
RL11
5
16V/1W
1N4745
ZD3
R52
470R
1/2
TLO72
12
6
47K
10K
U5
(6=-16V,11=+16V)
R49
SG
RL8
220R
AG
C38
+16V
6
0.5W
C28
25V
470U
R89 560R R39 560R
C13
15P
R50
39N
PIN 11
0.5W
16V/1W
1N4745
ZD2
CHAS-GND
SG
4K7
RL7
5A-FB
SG
R90
C27
25V
470U
AG
TLO72
50K
R54
QL1
MPSA56
RL4
F3
1N5402
C14
47n
250V
SG
SG
IG
0.5W
680R
GREEN
U3
+16V
1/2
SG
5
0.5W
C26
50V
2200U
R88
-38VDC
1
CW
TLO72
AG
1N5402
D4
C30
4n7
250V
C12
100P
R77
0.5W
560R
50V
C25 2200U
4K7
R47
16V
TLO72
R101
R72
470R
4U7
C9
C10
100N
50K
BASS
2
R73
C8
15P
F1
2
C102
100P
CW
RCA
R14
R75
0.5W
5A-FB
1N5402
D3
AG
FETCTL
R76 560R R37 680R
F2
1N5402
D2
T1
R15
IG
D6
1N4004
D1
C30 4n7
33078
AG
D8
+38VDC
D7
1N4004
1
1
150mVrms
2K2
R40
#1203
SW1
1M
RA18
0R27
RA19
0R27
POLY
QA3
12R
680P MJH11017
3
1
T
R
6
4
S JB8
PHONES
2 GOLD_S
AG
19Vrms
With Limiter
Defeated
100R
R31
CA5
1U5
22R
RA15
5W
10mVrms
R4
2
5W
JB1 S
MONO
NO_GOLD 2
562R
C7
16V
100U
5C P2
300R
R9
C31
25V
2U2
R42
0.5W
3
4K99
10K
R41
T1
CW
5W
1
R5
C29
25V
1U
5W
CHANNEL 1
INPUT
R3
C4
1N
R7
1.6A-SB
IG
EXPORT
10K VOLUME1
T800mA
MIC_IN
3
NUTRIX 1
3mVrms
CA8
SPKR1
10N
AG
4R
12"
#7288
CA4
RA20
3R9
SPKR2
8R
N252XN
#7270
-38VDC
DATE: SEP/13/2002
MODELS:
NAME: 100KW.SCH
PCB#&VER:
100KW
M579
SHEET
1OF
1
SCH ISSUE:
1.30
TITLE: 100W_MIXER_AMP
BOT W IP TOP
4418
JB1
3498
3660
JB2
BOT W IP TOP
10K
4418
P1
R2
470R
470R
3498
R72
R1 R14
R15
20K0
47K
47K
3498
JB4
C47
R70
470R
JB3
JB5
WHT
3460
4420
BOT W IP TOP
50K
P3
C49
100N
R51
SEE NOTE
BOT W IP TOP
50K
GRN
WC2
4420
BAR
5887
JB6
3498
2200U
3414
EFX_SEND
BAR
+16VDC
2415
R52
470R
JB7
3450
RED
WC1
F3
BLK
TO
AC
SWITCH
3414
CSA-5A-FB
EFX_RTN
P4
RED
GRN 18AWG
TO CHASSIS GROUND
3414
TAB1
AC HOT
6435
TRANSPRIM
TAB3
WC3
REPLACE WITH
SAME TYPE
FUSE250V
CE-F5A
R35
1K8
JB8
PHONES
GOLD-TIP
GOLD-SLV
3450
LED1
F1
RED
4n7
6451
WC10
CHASS
GND
22n
GRN
2406
3414
J6
J5
J4
RA9
CA4
RA8
RA7
CA3
RA6
RA5
R42
D8
100R
4692
100N
R41
6451
4148
1M
1N4004
1N4004
1M
10K
4148
4148
4148
47K
1K
1M
QL3
U5
U4
CL8
RL9
RL8
RL7
RL6
RL5
2K2
R40
ZD4
10K
1N5251
RL21
RL20
DL6
DL5
DL4
RL19
RL18
RL17
RL16
10M
MPSA56
1N5
RL4
RL3
DL1
ZDL1
RL2
RL1
QA3
CL2
CL1
5101
CL3
10K
10K
4148
4K7
220R
220R
10K
10K
10M
QA2
BC550C
1N5246
680R
68N
2U2
CE-T800MA
2415
C32
F2
TRANS
PRIM
CE-F5A
TAB7
MPSA56
C31
CSA-1.6A-SB
2200U
1N5402
DOWN
6827
3414
6827
BAR
1N5402
DOWN
D1
6827
BAR
1N5402
DOWN
D2
QL5
4148
ZDL2
QL4
4K7
22K
4K7
MPSA43
D4
YEL
TAB6
220R
220R
1N5240
DL7
1N5240
ZDL3
+38VDC
1N5402
DOWN
6827
D3
5887
22K
RL24
RL23
10K
100N
100N
1M
47K
5408
RA3
RA4
RA20
QL1
CA5
MPSA56
RL11
10K
12R
MPSA56
1U
3414
470U
TAB5
TAB8
BLK SPEAKER (-)
RL25
CL7
QL2
RL22
RL15
RL14
RL13
RL12
CL5
RL26
CL4
CL10
330N
CL6
R76
4734
3R9
1U5
5925
4729
47U
47n
C25
560R
R77
R37
QA7
RL10
10K
TABA1
0R27
33p
680P
3K3
3K3
100N
36K
27K
750R
270R
CA2
LM13600
C14
5621
C26
680R
680R
R75
560R
C11
R48
R50
47K
15P
47K
470R
R45
U3
R49
TLO72
C36
RTV
ZD2
1N4745
ZD3
C28
470U
C10
C37
C12
39N
100P
C27
1N4745
5621
100N
100N
R54
C9
4K7
R55
R90 -16VCD
4K7
C38
10N
22R
47K
TWEET (+)
TLO72
D6
D7
R31
6408
R73
20K0
39N
4U7
R44
47K
15P
C8
2N5638
R46
TLO72
560R
560R
560R
560R
CA8
RA15
RA14
100K
QA5
CA10
1K5
1K8
CA7
RA11
RA10
YEL
TABA2
1N
2U2
R39
22U
R47
C3
-38VDC
100N
R43
RA16
QA6
RA12
RA13
2K2
15P
47R
6802
C13
U1
12K
C1
R101
C2
R8
C5
R88 R89
47K
4K7
C102
R11
4K7
100N
49K9
100P
4K99
1N
C34
100N
CA9
6774
QA4
CA6
QA1
MJH11017
100N
4K7
2K2
MIC_IN
49K9
100P
R102
R5
562R
562R
R6
R4
R10
180K
BC560
OUTPUTSPKR(+)
LINE
MONO
R3
U2
BD139
470R
+
33078
4U7
BC560
RA19
R71
33U
C33
RA18
100N
R7
J3
J2
J1
FLAT SIDE DOWN
-
P2
C4
22U
C101
100U
1N
4K99
0R27
CA1
RA1
MJH11018
+
10K
4729
12R
22K
680P
68U
RED
LINE
C6
RA2
6779
4K99
4K99
301R
R9
C7
PT#7288
PT#7270
WAVE DIRECTION
C29
C30
AC RET
CSA-5A-FB
TAB2
TAB4
FOR 'E'
CHANGE
C32 22N
TO 100N
#5242
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
PCB ASSEMBLY DOCUMENTATION
A
A
B
B
SPECIAL PRODUCTION NOTES
1.
2.
3.
4.
5.
6.
7.
8.
C
PCB HARDWARE
QA2 IS HAND INSERTED
BEND QA2 DOWN INTO ROUTED AREA WITH TOP OF QA2 AGAINST TOP OF ROUTED AREA
OUTPUT DEVICES MOUNTED ON #8656 SPACERS
WC10 4" GREEN 22G TO CHASSIS GND.
WC2 12" GREEN 18G TO CHASSIS GND.
WC3 4" BLK 22G WIRE TO POWER SW.
WC1 4" BLK 22G WIRE TO POWER SW.
FOR CE CHANGE C32 TO 22N 100N #5242
C
D
D
E
E
F
F
G
G
H
H
I
I
J
J
OCT/08/15
JAN/22/16
5.00
5.00
DOUBLE SIDED PCB
FIXED CAP AND ADD HOLE UPDATED DRILL VERS.
Assembly Documentation
Section:
K
Product(s):
THIS SHEET CONTAINS SPECIAL PRODUCTION NOTES AND A LIST OF PCB HARDWARE PARTS REQUIRED FOR THE BUILD.
PCB#:
100KW
M579
Rev#: V05
Modified: 1/22/2016
1
2
3
4
5
6
7
8
9
10
11
12
13
14
K
EML Rev#:
File: Assembly.SchDoc
15
16
01
Sheet
1
Of
Tmp Rev: V031
17
*
4" GRN
GR NCHASS
GR ND
WC10
B L KTPRRAINMSA C R E T
.
GRN
.
RED
RED
YEL
S PE A KE R (-)
.
TA B4
.
220 0U
50V
TAB 5
TAB 7
.
.
.
TR AN S
PRB1
IM
TA
TA B6
220 0U
50V
A C HO T
TA B3 TA B2
C32
BLK
100KW AC WI RI NG
SEPT 13, 2002
VERSI ON 2. 00
WC1
BLK
TO
AC
S WI T C H
PT # 3698
AC SW IT CH
TOP OF CHASSIS
GR N
WC 6A
5" BLACK DBL/INSL
WC2
5" BLACK DBL/INSL
WC3
100K WC E
E XP OR T AC
WIR ING
S E P T 13, 2002
#8486
LOC K W AS HE R
C H A S S IS
4" G R N
G R N C HAS S
GR ND
WC 10
RET
.
B L KT PRRAINMSA C
GR N
.
RED
RED
YE L
11" B LAC K DB L/INS L
8 " G R N /Y E L L
S P E AK E R (- )
WC2
5" B LAC K DB L/INS L
P T # 3702
AC S W IT C H
T O P O F C H A S S IS
GRN
WC6A
5" WHIT E DB L/INS L
WC3
12 1/2" W H IT E DB L/INS L
TR AN S
PT AR BIM1
TAB 7
WC1
BLK
T O
AC
S WITC H
5" B LAC K DB L/INS L
2200U
50V
TAB 5
.
.
.
.
.
T AB 4
BLK
TAB 6
2200U
50V
AC HOT
T AB 3 T AB 2
C32

Similar documents

SERVICE MANUAL YSM1p

SERVICE MANUAL YSM1p table instables. L’appareil pourrait tomber et blesser quelqu’un ou subir des dommages importants. Utiliser seulement un chariot, un support, un trépied ou une table recommandés par le fabricant ou...

More information

SERVICE MANUAL

SERVICE MANUAL • To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture and objects filled with liquids, such as vases, should not be

More information