Transformers Weiz
Transcription
Transformers Weiz
Our Profile Fiscal Year 2014 Transforming Know-How into Solutions. EM TR LPT STW siemens.com/answers Structure 1. Overview and History Siemens Transformers 2. Facts and Figures Siemens AG ÖsterreichTransformers Weiz 3. Product and Service Portfolio Siemens AG ÖsterreichTransformers Weiz 4. References Siemens AG ÖsterreichTransformers Weiz 5. Business excellence Siemens Transformers Page 2 EM TR LPT STW © Siemens AG 2014 All rights reserved. Siemens Transformers The Business Units of Energy Management High Voltage Products Transformers Transmission Solutions Medium Voltage & Low Voltage & Systems Products Energy Automation Smart Grid Solutions & Services Bild Circuit Breakers Disconnectors and Earthing Switches Hybrid Switchgear Instrument Transform. Surge Arresters Coils Bushings Power Transformers High-Voltage, Direct-Current Transmission (HVDC) Air & Gas Insulated MV Switchgear Special Purpose Transformers Reactive Power Compensation / FACTS LV Switchgear & busbar trunking systems Traction Transformers Turnkey Grid Access Solutions Generator Switchgear Phaseshifter Transformers Solutions for Gasand Air-insulated Switchgear (GIS, AIS) Storage, grid coupling and sub–sea solutions, e-houses Distribution Transformers Gas-Insulated Switchgear (GISSystems) TLMTM #1 market position #2 market position Transformer Components Gas-insulated lines (GIL) #2 market position #3 market position Electrification Page 3 EM TR LPT STW LV Protection, switching, measuring & monitoring devices LV distribution boards /systems MV vacuum circuit breakers, contactors & interrupters Grid automation Grid protection Communication devices Power quality Sensors Grid control center Grid applications Meter data management Data analytics Software solutions Integration services Asset services #3 market position #1 market position #2 market position Automation Digitalization © Siemens AG 2014 All rights reserved. Siemens Transformers At all Levels of Transmission and Distribution • Wind, solar and hydro power integration • Offshore and onshore solutions • Applications for Smart Unit Auxiliary Transformers Generator Step-Up Transformers HVDC Transformers grid and distributed power generation Phase Shifters Static VAR FACTS Transformers System and SystemInterconnecting Transformers Shunt and Series Reactors TLM - Transformer Lifecycle Management Renewable Energy Solutions Grid Access Solutions Special Transformers for Industrial Applications Line Feeder Transformers • Online-Monitoring • Consulting & Expertise • Condition Assessment & Diagnostics • Maintenance & Lifecycle Extension • Spare Parts & Accessories Liquid immersed DTs for Distribution networks Page 4 Liquid DTs and CRTs for Infrastructure Solutions Voltage Regulators EM TR LPT STW Traction Transformers for Mobility Applications • Repair & Retrofit • Transport, Installation & Commissioning © Siemens AG 2014 All rights reserved. Siemens Transformers Business Overview Portfolio Key figures Power Transformers (≤ 1.300MVA / ≤ 1.100kV) • • • • • • • • 20 manufacturing locations in 14 countries worldwide, including Brazil, China, Germany, India, Russia and USA System interconnecting transformers (NET) • Global service setup with focus on Europe and USA Phase shifters • Approximately 8.000 employees worldwide • Manufacturing capacity approximately 280 GVA (max.) Generator step-up transformers (GSU) Special transformers for industrial applications HVDC converter transformers Line feeders for rail system power supplies Market 2013 – 2019 Shunt and series reactors Distribution Transformers • • • Liquid-immersed transformers (≤ 30MVA / ≤ 72,5kV) Cast-resin transformers GEAFOL (≤ 50MVA / ≤ 72,5kV) Voltage regulators Traction transformers for rail vehicles (≤ 10MVA / ≤ 50kV) Transformer Lifecycle Management (TLM) Power Transformers Page 5 Distribution Transformers • Transformers market is currently growing by ~3% p.a. driven by USA, China and India • Global trends towards Energy efficiency improvement (e.g. via HVDC) and grid interconnections • Siemens Transformers is in no. 2 position worldwide Traction Transformers EM TR LPT STW TLM © Siemens AG 2014 All rights reserved. Siemens Transformers Merged strengths – our history 1955 1960 1965 1970 1975 1980 1985 1990 1995 2000 2005 2010 Est. in Siemens Schuckert 1903 PTD Energy VEB Transformatoren- und Röntgenwerk 1904 Transformers 1921 Csepel Transformers 1960 Transformers 1836 ELIN AG ELIN-Union AG Elektrobau AG 1920 1912 EV Transformatoren 1883 1892 Trafo Ferranti Ferranti-Packard Transformers 1894 Packard Page 6 EM TR LPT STW © Siemens AG 2014 All rights reserved. Siemens Transformers has a global footprint of 20 locations in 14 countries EM TR – Overview and history Trois-Rivieres Jinan Canada China Jackson Wuhan USA China Guanajuato Guangzhou EM TR Mexico China Tenjo Karachi Locations Colombia ~2,000 km Pakistan Jundiai Kirchheim Nuremberg Dresden Nuremberg Trento Weiz Linz Zagreb Budapest Voronezh Kalwa Brazil Germany Germany Germany Germany Italy Austria Austria Croatia Hungary Russia India Page 7 EM TR LPT STW © Siemens AG 2014 All rights reserved. Structure 1. Overview and History Siemens Transformers 2. Facts and Figures Siemens AG ÖsterreichTransformers Weiz 3. Product and Service Portfolio Siemens AG ÖsterreichTransformers Weiz 4. References Siemens AG Österreich-Transformers Weiz 5. Business excellence Siemens Transformers Page 8 EM TR LPT STW © Siemens AG 2014 All rights reserved. Siemens AG Österreich-Transformers Weiz Weiz, Austria Austria Member of the European Union Population … 8.507.786 Area … 83.878 km² Federal States… 9 Page 9 Plant Weiz Since … 1892 Employees … 1153 Area … 54.300m² EM TR LPT STW © Siemens AG 2014 All rights reserved. Siemens AG Österreich-Transformers Weiz Company History 2012 “SIEMENS Aktiengesellschaft Österreich – Transformers Weiz” 2007 “SIEMENS Transformers Austria GmbH & Co. KG” 2005 Integration into SIEMENS 2003 VA TECH ELIN Transformatoren is one of two competence centers of VA TECH Transformers worldwide 2000 “VA TECH ELIN Transformatoren GmbH & Co.” 1990 “ELIN Transformatoren GmbH” 1988 Transformer Division was established 1959 “ELIN Union AG für Elektrische Industrie” 1922 “ELIN Aktiengesellschaft für Elektrische Industrie” 1892 “Franz Pichler Werke” – First Transformer Page 10 EM TR LPT STW © Siemens AG 2014 All rights reserved. Siemens AG Österreich-Transformers Weiz Mission Statement Page 11 EM TR LPT STW Strategic partner for our customers Utmost performance by motivated & qualified employees Customer oriented, ecological & economical solutions Technology leader through innovation © Siemens AG 2014 All rights reserved. Siemens AG Österreich-Transformers Weiz Milestones in Development 1996 : 1300 MVA Transformer (USA) 1993 : 650 MVA / 525 kV / ±24°Phase Shifter (USA) 1892: “Franz Pichler” First Transformer 2007 : 1200 MVA / 400 kV / ±24°±32 Taps Phase Shifter (Germany) 2005 : 420 MVA / 345 kV - 57 dB(A) Transformer (USA) 1986 : 975 MVA Transformer (USA) 1892 1965 1986 1996 1989 : 765 kV – BIL 2050 Transformer (USA) 1951 : 230 kV Transformer (Austria) 2014 : 1200 MVA / 410 / 410 ± 20°(No Load) ± 32 steps Phase Shifter(Poland) 2005 2009 2012 2014 2008 : 133 MVAr / 765 kV Single Phase Shunt Reactor (South Africa) 2012 : 100 MVA / 735 kV Single Phase SVC Transformer (Canada) 1965 : 800 kV Transformer (USA) 1965 : 400 kV Transformer (Sweden) Page 12 EM TR LPT STW © Siemens AG 2014 All rights reserved. Siemens AG Österreich-Transformers Weiz Figures (app.) – FY 2014 FY 2014 FY 2013 Order Intake € 330 Mio € 313 Mio Turn Over € 331 Mio € 353 Mio Production Area 54.300 m² 54.300 m² 47.300 47.200 7.300 7.200 40.000 40.000 969* 974* Employees (Office) 359 361 Employees (Workshop) 547 544 Apprentices 63 69 Production Capacity in MVA Distribution Transformers Power Transformers and Shunt Reactors Employees (September 2014) *) incl. temp. Staff 1153 *) incl. temp. Staff 1177 Page 13 EM TR LPT STW © Siemens AG 2014 All rights reserved. Siemens AG Österreich-Transformers Weiz Annual Production in MVA overall 60000 50000 TARGET 40000 30000 20000 10000 0 Page 14 07 08 09 10 11 EM TR LPT STW 12 13 14 15 © Siemens AG 2014 All rights reserved. Siemens AG Österreich-Transformers Weiz Markets FY 2014 Order Intake (€ 330 Mio) Turn Over (€ 331 Mio) 2% 9% 19% 39% 26% 5% 54% 20% Europe Austria 12% 14% N/M East Africa Americas Asia/Australia Page 15 EM TR LPT STW © Siemens AG 2014 All rights reserved. Siemens AG Österreich-Transformers Weiz Markets FY 2014 – LPT only Order Intake (€ 204,4 Mio) Turn Over (€ 203,5 Mio) 1% 2% 2% 4% 25% 28% 48% 39% 12% 4% 18% Europe Austria 18% N/M East Africa USA Canada Asia/Australia Page 16 EM TR LPT STW © Siemens AG 2014 All rights reserved. Structure 1. Overview and History Siemens Transformers 2. Facts and Figures Siemens AG ÖsterreichTransformers Weiz, Austria 3. Product and Service Portfolio Siemens AG ÖsterreichTransformers Weiz 4. References Siemens AG ÖsterreichTransformers Weiz 5. Business excellence Siemens Transformers Page 17 EM TR LPT STW © Siemens AG 2014 All rights reserved. Siemens AG Österreich-Transformers Weiz Products Power Transformers Phase Shifting Transformers Generator Step Up Transformers Substation Transformers (Multiwinding- & Autotransformers) Single- & Dualtank Symmetric & asymmetric Phase Angle 1ph and 3ph up to 1,300 MVA / 765 kV 1ph and 3ph up to 1,200 MVA / 765 kV Page 18 Distribution Transformers Reactors Standard Distribution Transformers Special Applications (Renewables, Industry, etc.) 1ph up to 150 MVAr / 1ph and 3ph 765 kV up to 3ph up to 250 MVAr / 20 MVA / 72,5 kV 765 kV (Adjustable) Shunt Reactors Seriesreactors EM TR LPT STW © Siemens AG 2014 All rights reserved. Siemens AG Österreich-Transformers Weiz Service Transformer Lifecycle Management (TLM) Page 19 EM TR LPT STW © Siemens AG 2014 All rights reserved. STW total delivered MVA and number of units worldwide MVA Number of Units 4.035 642.000 561.161 3.005 Total delivered MVA from 1937 to date Currently installed capacity suitable for commercial service Total number of units delivered from 1937 to date Total number of currently installed units suitable for commercial service In the period from 1937 to date, STW has supplied to 72 different countries and through the deployment of supervisors STW has been physically present in almost all of these countries. *) based on a 40 year lifetime Page 20 EM TR LPT STW © Siemens AG 2014 All rights reserved. Siemens AG Österreich-Transformers Weiz Service Repair & Retrofit Spare Parts & Accessories Transport On site repair Consulting Commissioning Engineering service Advice & recommendations for preventive, curative and corrective actions Diagnostic training Custom-tailored workshop Page 21 EM TR LPT STW © Siemens AG 2014 All rights reserved. Structure 1. Overview and History Siemens Transformers 2. Facts and Figures Siemens AG ÖsterreichTransformers Weiz, Austria 3. Product and Service Portfolio Siemens AG ÖsterreichTransformers Weiz 4. References Siemens AG ÖsterreichTransformers Weiz 5. Business excellence Siemens Transformers Page 22 EM TR LPT STW © Siemens AG 2014 All rights reserved. Siemens AG Österreich-Transformers Weiz Reference for Generator Step Up Transformer Generator Step Up Transformer Customer EDF, France Destination Nuclear Power Plant Cattenom and Creil Delivery 2010-2012 (4 units) Rating 570 MVA, single-phase GSU 405/20 kV Key Features Short circuit test on model transformer Replacement of old transformer under very limited space and timely conditions Page 23 EM TR LPT STW © Siemens AG 2014 All rights reserved. Siemens AG Österreich-Transformers Weiz Reference for Generator Step Up Transformer Generator Step Up Transformer Customer Exelon, USA Destination Quad Cities/Dresden Power Station Delivery 2006-2008 (4 units) Rating 1100 MVA, three-phase GSU 362/18 kV Key Features Two LV high current bushings per phase (current 17.6 kA) Special cooling design for temperature-control on LV turret Page 24 EM TR LPT STW © Siemens AG 2014 All rights reserved. Siemens AG Österreich-Transformers Weiz Reference for Autotransformer Autotransformer Customer ESKOM, South Africa Destination Big Horn Substation and others Delivery 2007-2013 (12 units) Rating 800 MVA, three-phase AUT 400/275/22 kV Key Features 232 tons per heavy part with dry air Total weight fully assembled 390 tons per unit. Page 25 EM TR LPT STW © Siemens AG 2014 All rights reserved. Siemens AG Österreich-Transformers Weiz Reference for Phase Shifting Transformer Phase Shifting Transformer Customer ELES, Slovenia Destination Divača Substation Delivery 2010 Rating 1200 MVA, three-phase PST 400/400 kV Key Features Phase Angle ±40° 4 tanks max. 306t transportation weight each (excl. oil) Used for Power Flow Control between Slovenia and Italy. Page 26 EM TR LPT STW © Siemens AG 2014 All rights reserved. Siemens AG Österreich-Transformers Weiz Reference for Phase Shifting Transformer Phase Shifting Transformer Customer ALPIQ, Switzerland Destination Lavorgo Station Delivery 2011 Rating 800 MVA PST 420/√3 // 247/√3 // 33 kV, ±9.6° Key Features ONAN / ODAF Single Phase PST Bank incl. Spare Biggest unit ever to cross below the Alps by using the 9-mile Gotthard railroad tunnel Page 27 EM TR LPT STW © Siemens AG 2014 All rights reserved. Siemens AG Österreich-Transformers Weiz Reference for Shunt Reactor Single Phase Shunt Reactor Customer AEP, USA Destination Rockport and others Delivery 2005 through 2013 (36 units) Rating 100 MVAr SHR 765/√3 kV Key Features ONAN Low Loss Design Full Type Tests Page 28 EM TR LPT STW © Siemens AG 2014 All rights reserved. Siemens AG Österreich-Transformers Weiz Reference for Series Reactor Series Reactor Customer Singapore Power, Singapore Destination Tembusu Substation Delivery 2013 (3 units) Rating 500 MVA three-phase CLR 230 kV Key Features First Series-Reactor in Singapore Page 29 EM TR LPT STW © Siemens AG 2014 All rights reserved. Siemens AG Österreich-Transformers Weiz Reference for Renewable Energy – Transformer for Wind Turbines Transformer for Wind Turbines Customer Siemens Wind Power / Dong Energy Destination Windfarm Anhold, Denmark Delivery 2013 (111 units) Rating 4 MVA Ratio 33000 / 690 V Key Features Hermetically sealed with rubber bag Filling with ester Midel 7131® (biodegradable) Nomex® high temperature insulation Fully aluminium windings Zincflake coating system acc. C5M (marine standard) with 240 µm layer thickness KFAF cooling (forced liquid / forced air) Installation inside the wind turbine Page 30 EM TR LPT STW © Siemens AG 2014 All rights reserved. Siemens AG Österreich-Transformers Weiz Reference for Generator Step Up Transformer Generator Step Up Transformer Customer KWD GmbH Destination Hydro Power Plant Dientenbach, Austria Delivery 2011 (1 unit) Rating 6300 kVA Ratio 30200 / 6300 V Key Features Expansion tank design Low loss design Sound pressure level 45 dB(A) only @ 0,3 m Zincflake coating system with 210 µm layer thickness Fully type tested (Noise level, Heat run test, Lightning impulse test, partial discharge test) Page 31 EM TR LPT STW © Siemens AG 2014 All rights reserved. Siemens AG Österreich-Transformers Weiz Reference for Transformer for 24-pulse Drive Application Transformer for 24-pulse Drive Application Customer Mutanda Mining Group Destination Congo Delivery 2013 (2 units) Rating 5500 kVA Ratio 22000 / 4 x 2200 V Key Features Vector group D+7,5°y11d0 and D-7,5°y11d0 Conservator hermetically sealed (rubber bag) Cable boxes IP54 Zincflake coating system acc. C5M marine standard with 240 µm layer thickness Fully equipped with CT’s for differential protection (3 pcs. CT’s HV side, 12 pcs. CT’s LV side) Special protection devices Page 32 EM TR LPT STW © Siemens AG 2014 All rights reserved. Structure 1. Overview and History Siemens Transformers 2. Facts and Figures Siemens AG ÖsterreichTransformers Weiz 3. Product and Service Portfolio Siemens AG ÖsterreichTransformers Weiz 4. References Siemens AG ÖsterreichTransformers Weiz 5. Business excellence Siemens Transformers Page 33 EM TR LPT STW © Siemens AG 2014 All rights reserved. For us, excellence is leadership in quality, environmental care, health and safety Therefore, we continuously work to live excellent business processes … … because excellence in processes leads to operational excellence … because good processes are prerequisite to achieve customer satisfaction Our Management Policy and Business Charter build the basic framework Source: E T TR BE Page 34 EM TR LPT STW © Siemens AG 2014 All rights reserved. Excellence in processes is standardization, harmonization and continuous process improvement Business Process Management (BPM) Comprises process management of all processes within the defined company structure Our objectives: Targeted control of Business, Management and Support Processes Focuses on clearly structured process presentation Created value for customers, employees, and business partners through efficient and effective processes Standardization of processes for us is an important success factor Source: E T TR BE Page 35 EM TR LPT STW © Siemens AG 2014 All rights reserved. The holistic and integrated process house approach is our way to realize process excellence Transformer Process House (TPH) TPH provides the standardized processes to all departments and factories. TPH is the basis for a common language and terminology in all units of E T TR. Source: E T TR BE Page 36 EM TR LPT STW © Siemens AG 2014 All rights reserved. Our manufacturing processes in operation 1) Transformer design A strong global network of highly experienced engineers (>500) Proven standard design or Individual mechanical and electrical design to customers requirements State of the art design processes using CAE* methods, pre-testing algorithms and latest results of our R&D departments and materials and high voltage laboratories 2) Core building Fully automated core cutting Stacked cores with GOES steel Manual core stacking up to 350 tons according to customer requirements and product type CAE : Computer Aided Engineering e.g. finite elements analysis Page 37 EM TR LPT STW 3) Winding shop Manual laying of windings for optimal materials handling with perfect results according to product type Layer or disc windings with copper or aluminum conductors Winding processing including pressing and pre-drying Inhouse insulation workshops © Siemens AG 2014 All rights reserved. Our manufacturing processes in operation 4) Active part Inhouse lead preparation Arranging winding, core, lead and other components (e.g. tap changers) to active parts up to 400 tons Complex active part assembly in desert climate chambers for highest manufacturing quality Page 38 5) Final assembly Assembly area with equipment up to 400 tons of total weight capacity to unify tank and active part Sophisticated vacuum and oil filling processes with final filtration EM TR LPT STW 6) Testing High tech test field suitable to test units up to 800 kV Full compliance with any existing international standard Guaranteed functionality of all devices © Siemens AG 2014 All rights reserved. Our manufacturing processes in operation 7) Transport 8) Commissioning We check and handle the complete transport procedure from our manufacturing facility to the customer on site Long experience with first class transportation partners for rail, water and road all over the world Deep knowledge and experience in installing and commissioning our products worldwide (incl. nuclear power plant certification) Customer trainings in the factory and on site Highest level of EHS-regulations (zero harm culture) *TLM : Transformer Lifecycle Management Page 39 EM TR LPT STW 9) Service & Repairs Strong global network of experts from14 countries for unparalleled expertise and every-time and every-place support TLM* with condition assessment, diagnostics, online monitoring, repair and retrofit Facilities and experience with Siemens and competitor products © Siemens AG 2014 All rights reserved. Excellence in operation – this is our quality We believe in quality to be the primary lever for products and solutions with exceptionally successful innovations. Experienced Workforce Periodic and standardized training Competence management Modern and reliable equipment Highest quality Fast and flexible Standardized Production Processes World wide production standards Clear commitment to EHS (zero harm culture) Environmental Friendly Production Avoid energy wasting processes Energy recycling Siemens Production System Lean production Continuous improvement Source: E T TR BE Page 40 EM TR LPT STW © Siemens AG 2014 All rights reserved. All our locations are ISO 9001, ISO 14001 and OHSAS 1801 certified Page 41 EM TR LPT STW © Siemens AG 2014 All rights reserved. Environmental Portfolio audited and approved by Ernst&Young since 2011 Source: E T TR BE Page 42 EM TR LPT STW © Siemens AG 2014 All rights reserved. Clean electrification for societies Thank you! Restricted © Siemens AG 2014 All rights reserved. Page 43 EM TR LPT STW siemens.com/answers © Siemens AG 2014 All rights reserved.