two.2.block - König + Neurath
Transcription
two.2.block - König + Neurath
The new patent solution for more efficient use of space. Freiräume für Leistung. TWO.2.BLOCK TWO.2.BLOCK TWO.2.BLOCK – the new patent solution for more efficient use of space. An innovative room system is the ultimate answer to the large-scale budgeting challenges encountered when constructing a new building as well as redeveloping existing property. Whenever shorter utilisation cycles and changing space requirements make it necessary to redesign room layouts frequently, Two.2.Block provides a solution that is affordable as well as extremely flexible. The patented modular bi-block system guarantees a low-cost, resource-friendly system that gives you unbeatable value for money – starting with production and logistics up to the point of installation and alteration. Mobility in facilities. Efficient, flexible and transparent. Two.2.Block features transparent and opaque wall modules that fulfil these requirements on a permanent basis. There are numerous design possibilities to provide maximum variability. Transparent flexibility. TWO.2.BLOCK’s functional design is the basis for a high-quality room system. With its modular structure, TWO.2.BLOCK can be transported as a mono-block or bi-block. This makes handling quick and easy. Patented connector Welt track 1 l Transparent wall with flush-fitted double glazing including entrance door. Laminated safety glass ensures good acoustic properties. Entrance door with concealed closure and optional floor seal). Panel covering all electrical installations for building facilities. Installation the new way. The TWO.2.BLOCK logistics concept. For industrial quality even during installation. TWO.2.BLOCK is quick and easy to reconfigure. The concept, assembly and logistics of Two.2.Block reduce installation/alteration time by around 85% compared with standard dry construction methods. There are fewer lost working hours and the areas are fit for use again more quickly – tangible budgeting factors that have a convincing effect. A new join between elements. Connecting the TWO.2.BLOCK elements. Today it’s a cubicle office and open space, tomorrow a multi-purpose office: altering the layout makes it possible to adapt the office structures to suit changing tenant requirements. Change has to be commercially viable. TWO.2.BLOCK reduces the costs of changing room structures and alteration projects. Time is money: TWO.2.BLOCK saves both. It is considerably faster to install and therefore more commercially viable than all other standard room systems. Two.2.Block – so that you reap benefits from your investments. Two.2.Block has a significant cost advantage right from the start compared with conventional dry construction partition systems. The cost of setting up a room as a price per square metre over a tenancy of five years on average works out 67% cheaper than it would do for conventional interior furnishing.*** Cost comparison based on length of tenancy* Cost per m2 (Euro) ** 2.000 Plasterboard wall 1.500 1.000 TWO.2.BLOCK 500 0 Tenancy length (years) 10 20% Investition, 80% Folgekosten – die Realität bei Büroimmobilien. Immer kürzere Vermietungszyklen und die individuellen Raumanforderungen der Mieter erfordern immer häufiger den Umbau der Bestandsflächen. Der Anpassungsdruck wird zum Kostenproblem, Ihre Rendite droht zu schrumpfen. Ein innovatives Raumsystem bietet die Lösung: Two.2.Block 9 8 7 6 5 4 3 * A ssuming the lifespan of office premises to be 30 years and the resulting alteration costs arising through each tenancy cycle for room partitioning. Does not take into account interest rates and inflation. ** Investment and alteration costs. *** Assuming the lifespan of office premises to be 30 years. Details. Absolute transparency. 2 1 3 1 l Hinge 3D adjustable 2 l Veneered door panel in Canadian maple 3 l Glazed key safe box 4 l Flush-fitted glazing Element frame axially split. Recessed groove, 10 mm wide. 4 TWO.2.BLOCK Detailed drawing TWO.2.BLOCK Schalldämmwert Product overview Test Prüfung cladding face 1.1st Schalenseite 2nd cladding face 2. Schalenseite Filling / Insulation Füllung/Dämmung Acoustic value Schalldämmwert RW,P, P,dB dB RW, Element Element ESG, TSG,88mm mm ESG,88mm mm TSG, keine none 36 36 Element Element Element Element VSG, LSG,88mm mm ESG, 8 mm TSG, 8 mm VSG,88mm mm LSG, VSG-S, 8 mm LSG-S, 8 mm keine none keine none 41 41 42 42 Element Element VSG-S, 8 mm LSG-S, 8 mm VSG-S, 8 mm LSG-S, 8 mm keine none 45 GLASS GLAS 45 Alle Prüfungen auf durchgendem Teppichboden. All tests on fully-carpeted floors. Door Tür TSG,88mm mm ESG, TSG, ESG,88mm mm none keine 35 35 Tür Door VSG-S, mm LSG-S,88mm VSG-S,8mm 8 mm LSG-S, keine none 37 37 Tests withmitfloor seal on threshold plate on carpeting Prüfungen Bodendichtung auf Höckerschwelle im Tepichboden (oderhard auf glattem, Boden). Ohne plate (or on smooth, floor). festen Without a threshold Höckerschwelle auf Teppichboden kann sich der Schallon carpeting, the acoustic value can be reduced by more than 6 dB. dämmwert um über 6 dB verringern. OPAK OPAQUE Wand Wall MELA, MELA,16 16mm mm MELA,16 16mm mm MELA, Miwo, 5050 mm Min. wool, mm 39 39 Wand Wall MELA, MELA,16 16mm mm MELA,16 16mm mm MELA, 43 43 Wand Wall MELA, 16 mm MELA, 16 mm MELA, 16 mm MELA, 16 mm Miwo, 4050 mm Min. wool, mm GK, 12,5 mm Chipboard, 12,5 (1x) mm (1x) Miwo, 40 mm Min. wool, 50 mm GK, 12,5 mm (2x) Chipboard, 12,5 mm (2x) Min. wool, mm Miwo, 4040 mm 40 40 Prüfung einer kompletten Wand aus 4 Elementen. Wand (4,45 x 3,0 m) mitwall Wandanschluss. Test on a complete made up of 4 elements. Auf Teppichboden montiert. Walldurchgehendem (4.45 x 3.0 m) with wall connection. 45 45 Fitted on fully-carpeted floor. Wall Wand MELA,16 16mm mm MELA, MELA, MELA,16 16mm mm GK, 12,512,5 mm (1x) Chipboard, mm (1x) Prüfungen Bodendichtung auf Höckerschwelle im Tests withmitfloor seal on threshold plate on carpeting Tepichboden (oder auf glattem, festen Boden). Ohne (or on smooth, hard floor). Without a threshold plate Höckerschwelle auf Teppichbodenkann sich der Schallon carpeting, the6acoustic value can be reduced by more than 6 dB. dämmwert um über dB verringern. T SG: Tempered safety glass LSG: Laminated safety glass K+N 22 TWO.2.BLOCK K+N 23 TWO.2.BLOCK Deutschland König + Neurath AG Büromöbel-Systeme Industriestraße 1–3 61184 Karben Tel.: +49 (0)6039 483-0 Fax: +49 (0)6039 483-214 e-mail: info@koenig-neurath.de www.koenig-neurath.de Great Britain K + N International (Office Systems) Ltd 52 Britton Street London EC1M 5UQ Tel.: +44 (0)20 74909340 Fax: +44 (0)20 74909349 e-mail: sales@kn-international.co.uk www.kn-city.co.uk Nederland König + Neurath Nederland Office Furniture Airport Business Park Lijnden Frankfurtstraat 18–22 1175 RH Lijnden Tel.: +31 (0)20 4109410 Fax: +31 (0)20 4109419 e-mail: info@konig-neurath.nl www.konig-neurath.nl France König + Neurath AG Showroom Paris 66, rue de la Victoire 75009 Paris Tel.: +33 (0)1 44 63 23 93 Fax: +33 (0)1 44 63 23 97 www.koenig-neurath.de/fr Freiräume für Leistung.