CT130-EHS | CT130-DHSG | CT130
Transcription
CT130-EHS | CT130-DHSG | CT130
CT130-EHS | CT130-DHSG | CT130-CALOG Wireless headset systems on Siemens LF-workstation switch USB-Adapter CT130 Page 1 of 12 Product characteristics Plantronics wireless headset systems on Siemens NFworkstation switch USB-Adapter CT130 The EHS-adapters in the version CT130-EHS, CT130-DHSG and CT130-CALOG are adaptation moduls between the Siemens NF-workstation-switch-USB-Adapter and the wireless headset solutions of the companies Plantronics, Sennheiser and GN Netcom. The adapter versions differ in functionality and purpose. The business version (CT130-EHS supports the wireless Plantronics headset systems CS60, CS70, CS351/361 as well as Savi Office. The connection works by using the digital control output - Plantronics Serial Bus - (PSB) of the headset cradle. The robust Plantronics wireless headset solution was developed for a 24/7 use in control centers. A modified solution with integrated logic control and additional features is called CALOG. Apart from the call answer and termination exists a special highlight in the multiplex functionality of the Push-To-Talk (PTT)-button and external button, respectively. During a call the control functions could be activated using a keystroke, for example to open a door lock. This product is connected with the CT130-CALOG adapter. The DHSG-adapter CT130-DHSG realizes the transfer and the bidirectional headset control with DHSG1 headset solutions. This feature makes it possible to receice calls pushing a button on the headset or on the telephone or base station. Examples for comfortable wireless headsets with DHSG standard are products of the following manufactures: Plantronics, GN Netcom and Sennheiser. Compatible wireless headsets Business Version (p. 2-3) Business Plus Version (p. 4-6) Control Center Version (p. 7-10) CT130-EHS CT130-DHSG CT130-CALOG Plantronics CS60 | CS70 | CS351 CS 361 | Savi Office Plantronics CS60 | CS70 | CS351 CS361 | Savi Office Plantronics CA12CD - modified (CALOG) GN Netcom 9120 | 9350 | 9460 6470 | 9470 Sennheiser BW 900 | DW Office service- und dienstleistungszentrum GmbH leipzig für kommunikationssysteme CT130-EHS | CT130-DHSG | CT130-CALOG Wireless headset systems on Siemens LF-workstation switch USB-Adapter CT130 Page 2 of 12 Business Version CT130-EHS Mode of Operation, control and configuration Inside the adapter the digital control protocol will be converted from Plantronics (PSB) to analog input and output parameters. Using the jumper inside the adapter the cable connection configurations and the call options will be chosen. The schematic illustration on page 5 shows the jumper configuration at delivery status. At the 8-pin RJ45 connection cable the wiring is as follows: IN 1 and OUT 1 (as shown in the manual Siemens CT130). With the jumpers 1,2,3 at the jumper region A the cable connection configuration of the input of the CT130 is arbitrary. The modulation of the configuration of the output signal from CT130 could be determined by the jumper pairs 1 and 2 at the jumper region B. The call trigger from the output, directed to CT130 will be determined witch the jumper region C. If the Jumper C is not set, an impuls of at least 10 ms is enough to activate the call automatically. During this continuous call, the impulse will be converted to a call signal at the headset with an 1.2 sec duration. Compatible wireless Plantronics headsets of business version CT130-EHS CS 60 CS 70 CS 351/361 Savi Office service- und dienstleistungszentrum GmbH leipzig für kommunikationssysteme CT130-EHS | CT130-DHSG | CT130-CALOG Wireless headset systems on Siemens LF-workstation switch USB-Adapter CT130 Page 3 of 12 Support of two call options: û Continous ringing depending on closing time of raising delay. A call cycles of an 1.2 sec and a 2 sec break will be generated at the wireless headset. û The call initiation will become a ringing 1.2 sec (2 double ringings – delivery status). Functions û Call receiving and call completing at the headset. û Call activation at the cradle of the mobil handset. û Logic control at the CT130 for the headset status ON/OFF. CT130-EHS Siemens CT130 CT130-EHS Siemens CT130 on Plantronics Headset systems PC USB X3 PC RJ 45 USB Article description: CT130-EHS Made in Germany Fon: +49 (0) 341 8684230 www.headsetsysteme.de X2 PSB EHS Manufacture: SDZ-GmbH RoHS Control RJ 10 Low frequency and logic control e.g.: Plantronics CS 60 Schematic board illustration CT130-EHS wireless Plantronics headsets in Business Version CT130-EHS CT130 1A / 30V DC PSB in-house protocol EHS-Input A 8 1 4 Meter 1 2 * C 3 1 1 2 * * 2 1 x3 8 PSB converter * calloption 3,5 mm phone jack call detector B A - Input signal for CT130 B - Output signal from CT130 call signal at least 10ms * delivery status service- und dienstleistungszentrum GmbH leipzig für kommunikationssysteme CT130-EHS | CT130-DHSG | CT130-CALOG Wireless headset systems on Siemens LF-workstation switch USB-Adapter CT130 Page 4 of 12 Business Plus Version CT130-DHSG - bidirectional Connection and bidirectional control wireless headset systems 1 at DHSG -interface at Siemens USB-Adapter CT130 Siemens USB-Adapter CT130 CT130 PC USB CT130-DHSG compatible headsets CT130 - DHSG Adapter Protocol converter, Siemens CT130 at DHSG headset interface - bidirectional X3 PC RJ 45 USB X2 Made in Germany Fon: +49 (0) 341 8684230 www.headsetsysteme.de RJ 10 logic control ext. Button Product characteristics The CT130-DHSG-Adapter operates bidirectionally. This feature enables a two-way control between the headset cradle and the phone. A telephone call can be received and terminated on the headset or on the phone. The adapter converts the CT130 control-protocol into the DHSG headset protocol. The used headset technique is not proprietary. Furthermore an optional connection for a external pedal button for the control of the headset is integrated. An integrated link plug (bridge one) switches the mode of operation on “send PTT“ when the jumper is open. This means that the phone is controlled only after a incomming call. service- und dienstleistungszentrum GmbH leipzig für kommunikationssysteme CT130-EHS | CT130-DHSG | CT130-CALOG Wireless headset systems on Siemens LF-workstation switch USB-Adapter CT130 Page 5 of 12 Technological functionality Link: X2 and X3 on CT130 Call for headset cradle, 1:3. The incomming call-signal will be transmitted over X3, pin 5 and pin 6 (DHSG-protocol) to the headset cradle in real-time. Calling acceptance by CT130 CT130-Control (output-signal X3, pin 7 and pin 8): ON/OFF. Managed by converter und will be sended to headset cradle (DHSG). At the same time the control-signal „Answer a telephone call“ is sended over input CT130, X3, pin 1 and pin 2. Call signal stop Open X3, pin 7 and pin 8, signal over X3, pin 1 and pin 2 unlinked by the converter. Calling acceptance over wireless headset Answering and termination will be managed by pressing on the headset-button. The headset cradle DHSG-protocol is converted into the switch-signal to the CT130, link X3 (pin 1 and pin 2). (calling acceptance and hang up). For system synchronisation the CT130 must be send a response (ON/OFF) to link X3, pin 7 and pin 8 to the CT130 converter. Afterwards the converter sends a DHSG protocoll command to the headset cradle. The trigger criterion (active ON) on X3 (pin 7 and pin 8) must be present as long as the signal exists on pin 1 and pin 2. External pedal button Function calling acceptance using external button: call-signal on link X3, pin 5 and pin 6 switching by call-frequency → causing DHSGû signal on headset cradle external button is pressed → DHSG-Code is sended to the cradle → link on X3, pin 2 û and pin 2 will be closed → call answering feedback signal → active on link X3, pin 7 and pin 8 will await for the confirmation → û code will be sended to cradle for synchronisation. service- und dienstleistungszentrum GmbH leipzig für kommunikationssysteme CT130-EHS | CT130-DHSG | CT130-CALOG Wireless headset systems on Siemens LF-workstation switch USB-Adapter CT130 Page 6 of 12 Functions special Function Call by ext. button û Ext. button is pressed → converter opens link X3, pin 1 and pin 2. û Link CT130 (active criterion) X3, pin 7 and pin 8, open. û The converter sends OFF-Code to headset cradle. û Wireless headset OFF (stand by). All operations are free in order and can be combined. Connector pin assignment CT130 X3 8 CT130-DHSG controller CS60 APS1 VK 2026 1 8 output call answer/complete output 2 Mi output 1 Rec 150 ohm Rec input optocoupler call Mi input 1 input optocoupler active criterion 8 1 DHSG to PSB 1 X2 Mi LED operating mode Rec Rec Mi VK 2002 Link closed: only phone Link opened: phone + wireless-PTT function (Push-to-Talk) ~ power supply 9V AC ~ external pedal button (3,5 mm phone jack) service- und dienstleistungszentrum GmbH leipzig für kommunikationssysteme CT130-EHS | CT130-DHSG | CT130-CALOG Wireless headset systems on Siemens LF-workstation switch USB-Adapter CT130 Page 7 of 12 Control Center Version CT130-CALOG Siemens USB-Adapter CT130 CT130 CA12CD or with logic control (CALOG) CT130-CALOG LF-Working station switch - Siemens CT130 at Plantronics headset PC USB X3 PC Article description: CT130-CALOG RJ 45 USB PTT Button LF Signal Logic control Manufactor: SDZ-GmbH X2 Made in Germany Tel.-Hotline: +49 (0) 341 8684230 www.headsetsysteme.de RoHS RJ 10 low frequency logic control with CALOG ext. pedal button Product characteristics active signal call special functions e.g.: door lock The adapter CT130-CALOG was optimized for the control center application and offers besides the input of professional wireless headsets plantronics CA12CD with push-to-talk (PTT) button although an extended functionality as compared to the adapter version CT130-EHS. Through the connection of an external button (pedal) at the EHS adapter, with the same performance as the PTT button at the headsets, an efficient remote control of the phone/USB and the wireless headset solution is possible. Apart from the call answer and termination exists a special highlight in the multiplex functionality of the PTT button and the external button, respectively. During a call, the control functions could be activated using a keystroke, for example to open a door lock. (Capabilities: barrier site, emergency call, attack report, process control, recording, door lock) Is the modified headset solution CA12CD, called „CALOG“, in operation, the feature: automatically logic control/ headset ON after the removal of the mobile headset from the recharger, could be used. service- und dienstleistungszentrum GmbH leipzig für kommunikationssysteme CT130-EHS | CT130-DHSG | CT130-CALOG Wireless headset systems on Siemens LF-workstation switch USB-Adapter CT130 Page 8 of 12 The application of the modified headset solution CA12CD, called CALOG, combines following advantages: Uncomplicated û non-stop operation. Fast cut connector for personalized headsets (each employee has its own) automatic headû set detection and switch over in headset service after removal from recharger of the base station (necessary for control center logic switch). Microphone and receiver analysis, criterium for logic control. û Masking of calls in headset. û Control of “door lock function” during a call using the push-to-talk button at the mobil handû set or the external button. Special push button at the mobile headset in halt and non-halt functionality for specific û applications. Low radiation system - health neutral. û Wireless disconnection using a button on mobile headset (Stand by). û High capacity battery in stand by. û Functions Call answer û and termination at the mobile headset (PTT button). Call ringing masking to hearing level. û Logic control on CT130, headset service ON for control center implementation. û External pedal button for call answer and completing. û Two way control for active analysis and control of external applications like ELA, speaker, acû tive notification. Two way contact for call analysis and control of external application, like central notificaû tions, signaling device. Two way contact activated by keystroke for the control of external applications, like door û lock, barrier site, alarm, call, attack report. Prevention of call waiting during an open connection (ON). û service- und dienstleistungszentrum GmbH leipzig für kommunikationssysteme CT130-EHS | CT130-DHSG | CT130-CALOG Wireless headset systems on Siemens LF-workstation switch USB-Adapter CT130 Page 9 of 12 Extended functions CT130-CALOG with modified CA12CD (CALOG) û It is communicated to the CT130 and to the logic control, if the mobile headset is loaded to the base station and the automatic headset service is shifted to the hand receiver. Short and long keystroke û The multiplex functionality is activated by pushing the PTT button at the mobile headset or the external button under 0.5 seconds for call control and by pushing over 1 second, the special application, like the door lock will be activated. The switching operation is defined by 1.8 seconds. A blocked button will be ignored after first analysis. û Insert optional û To simplify the installation of the systems a insert is offered. It is delivered together with the adapter and 3x 20cm fast connecting wire. In the insert the relay outputs for external control systems could be switched on by spring clips. service- und dienstleistungszentrum GmbH leipzig für kommunikationssysteme CT130-EHS | CT130-DHSG | CT130-CALOG Wireless headset systems on Siemens LF-workstation switch USB-Adapter CT130 Page 10 of 12 With the adapter the input and output signals are adjusted to the combined system solution. The received call signal from the CT130 causes a powerfree masking of the ringing into the hearing level of the mobile headset. The definition of the mode of operation, if the call is connected over short term impulse or in real time, will be determined by the jumper region B in the adapter. In delivery status the jumper B is set and a call impulse is enough and an own signal cycle will be generated. The PTT button at the mobile headset and the external button to the remote control of the CT130 as well as the bidirectional mode of operation with the switch function active ON of the CT130 and the door lock function through the keystroke are confirmed by a tone in the headset. In delivery status the jumper C in the adapter is set and the conformation tone is switched on. On the left hand site of the shell the 3.5 mm phone jacks are situated for external hook ups and three output sockets, each with relay switch. The power is supplied from the headset technique. Schematic board illustration CT130-CALOG CT130 0,3A / 30V DC 1 1 A - input signal for CT130 B - output signal from CT130 C- B A 8 * Mode of operation, set up and configuration * 2 C * CA12CD or CALOG (with logic control) 3 6 Microcontroller calloption call call detector optoc. 1 x3 4 Meter 8 1 active Mi Hö call ringing in headset Mi x2 PTT button optoc. call signal at least 10ms optoc. 0,5A 30V DC * delivery status phone jack 3,5 mm ext. pedal button actice signal call special functions e.g.: door lock service- und dienstleistungszentrum GmbH leipzig für kommunikationssysteme CT130-EHS | CT130-DHSG | CT130-CALOG Wireless headset systems on Siemens LF-workstation switch USB-Adapter CT130 Page 11 of 12 Wiring diagramm Business Version CT130-EHS Plantronics Siemens CT130 LF-Working station switch - Siemens CT130 X3 8 RJ 45 1 PC USB Input/Output Software controlled at Plantronics headset PSB 1 Article description: CT130-EHS 8 CS 60 Manufacture: SDZ-GmbH Made in Germany Fon: +49 (0) 341 8684230 www.headsetsysteme.de CS 70 RoHS X2 RJ 10 logic control headset service ON/OFF NF (Tonsignale) CS 351/361 Savi Office Business Plus Version CT130-DHSG Siemens USB-Adapter CT130 CT130 PC USB CT130-DHSG compatible headsets CT130 - DHSG Adapter Protocol converter, Siemens CT130 at DHSG headset interface - bidirectional X3 PC RJ 45 USB X2 Made in Germany Fon: +49 (0) 341 8684230 www.headsetsysteme.de RJ 10 logic control ext. Button service- und dienstleistungszentrum GmbH leipzig für kommunikationssysteme CT130-EHS | CT130-DHSG | CT130-CALOG Wireless headset systems on Siemens LF-workstation switch USB-Adapter CT130 Page 12 of 12 Wiring diagramm Control center version CT130-CALOG Plantronics NT12V 230V/AC Siemens CT130 PC X3 8 RJ 45 1 input/output logic control 1 LF-Working station switch Siemens CT130 at Plantronics CA12CD 8 6 Article description: CT130-CALOG USB 4 6 Manufacture: SDZ-GmbH Made in Germany Fon: +49 (0) 341 8684230 www.headsetsysteme.de RoHS X2 CALOG (CA12CD modified) RJ 10 Push-to-Talk-Button LF + logic control logic control headset service ON/OFF Splitter Active Call special functions e.g.: door lock Functions û call answer û call termination û door lock function during call with keystroke optional ext. pedal button CT130-EHS Adapter Item-no.: 14011001 Dimensions (HxWxD in mm): Ports: Power supply: CT130-CALOG Adapter Item-no.: 14011002 40x70x20 RJ 45 - CT130-X3 3,5 mm phone jack at PSB PSB headset station Dimensions (HxWxD in mm): Ports: Power supply: 115x65x26 RJ 45 - CT130 - X3 RJ 10 - LF-CT130 - X2 3,5 mm phone jack for ext. button RJ 12 - CALOG over CA12CD CT130-DHSG Adapter Item-no.: 01031001 | 01031002 Dimensions (HxWxD in mm): Ports: 46x81x18,5 RJ 45 - CT130-X3 SDZ-CT130-eng-6.2010-01 Techn. parameters Item-no.: 01031002 incl. DHSG-Adapter Plantronics 1 DHSG - Drahtlose Hör- und Sprechgarnitur service- und dienstleistungszentrum GmbH leipzig Schönbachstraße 65a 04299 Leipzig für kommunikationssysteme http://www.headsetsysteme.de E-Mail: info@modicom.de Fon: Fax: +49 (0)341 86 84 2-30 +49 (0)341 86 84 2-33