Data sheet Central domestic ventilation unit with heat recovery: ZL 400
Transcription
Data sheet Central domestic ventilation unit with heat recovery: ZL 400
Data sheet ZL 400 Central domestic ventilation unit with heat recovery Domestic ventilation unit with heat recovery and bypass for controlled ventilation and de-aeration of apartments and residential buildings with a central air distribution system. Efficient constant volume flow regulated EC fans with three fan levels, individually programmable air volumes for each level.Heat recovery from the exhaust air via cross-counterflow heat exchanger. Ice protection with automatic defrosting.Automatic summer bypass with adjustable switching temperature for using cool night air in the summer by interrupting heat recovery.Integrated self-diagnosis system with safety switch-off of the ventilation unit to prevent the creation of vacuums in the building, to protect unheated living quarters from overcooling, optionally via external smoke alarm.Illuminated LCD operator panel with multilingual clear text menu navigation on the device. Integrated real-time clock and weekly timer with up to 9 switching programs per day (individual) for 7 weekdays, for timed control of fan levels and automatic operation.The device can optionally be controlled via a wired remote control, a wireless remote control or according to need via automatic air volume regulation by using a CO2 and/or humidity sensor to determine the exhaust air quality. Digital and analogue inputs and outputs are integrated to enable external control.Filters for supply air, exhaust air and bypass, filter class G4. Filter change indicator on the ventilation unit display (can be set between 2 and 6 months). Filters can be changed without the use of tools.The inner lining of the unit is made of EPP and complies with fire protection class B2. Outer casing made of powder-coated sheet steel, white (RAL 9010), inspection doors made of plastic, light grey.Air duct connections on the top of the device, wall mounting possible using the wall bracket supplied. The condensate connection is located on the bottom of the ventilation unit. The ventilation unit is fully functional without any additional accessories. Technical data Dimplex Central domestic ventilation unit with heat recovery Typ ZL 400 Einsatzbereich Luftvolumenstrom bei 120 Pa stat. Druckdiff. max. Ventilatorstufen Luftvolumenstrom (programmierbar) Schalldruckpegel in 1 m Entfernung Wirkungsgrad Wärmerückgewinnung max. Bypass Bypass switching temperature Filterklasse Zuluft / Abluft Spannungsversorgung Max. power consumption Leistungsaufnahme Schutzart nach VDE Anschluss Lüftungsleitungen Condensate pipe connection Dimensions (W x D x H) Gewicht ohne Verpackung m³/h Stk m³/h dB (A) % A W mm mm kg Living quarters approx. 120-300 m² 380 3 130 / 240 / 350 35 / 48 / 60 87 Yes 18-26 (Standard: 24) G4 / G4 1/N/PE ~230 V, 50 Hz 2,60 200 IP 20 4x DN 160 Ø 20 750 x 469 x 725 35 *Air volume flow at a pressure loss within the pipe system of 120 Pa. **Please note that additional space is required for pipe connections, operation and maintenance. Glen Dimplex Deutschland GmbH Dimplex Division Am Goldenen Feld 18 95326 Kulmbach Page 1/1 Subject to change and errors! E-mail: dimplex@dimplex.de Internet: www.dimplex.de Internet: 21.05.2011 Phone: +49 (0)9221 709-201 Fax: +49 (0)9221 709-339