A B C D E
Transcription
A B C D E
EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ VAN EJ EJ EJ EJ VAN 301 TARROW STREET, 7th FLOOR COLLEGE STATION, TX 77840 (979) 458-7000 http://www.tamus.edu/business/facilities-planningconstruction/ EJ EJ EJ H.C. H.C. TEXAS A&M UNIVERSITY SYSTEM OFFICE OF FACILITIES, PLANNING, AND CONSTRUCTION EJ EJ EJ EJ H.C. EJ EJ EJ EJ EJ EJ EJ EJ EJ KSQ ARCHITECTS, PC STUDY COLLABORATE DESIGN COLORADO OKLAHOMA NEW YORK NORTH CAROLINA TEXAS EJ 1452 HUGHES RD., SUITE 150 GRAPEVINE, TX 76051 (972) 259-8500 http://www.ksqarchitects.com CONSULTANTS EJ CIVIL JQ ENGINEERING 2105 COMMERCE STREET DALLAS, TX 75201 (214) 752-9098 http://www.jqeng.com EJ LANDSCAPE ARCHITECT COLEMAN AND ASSOCIATES 9890 SILVER MOUNTAIN DRIVE AUSTIN, TX 78739 (512) 476-2090 http://www.colemanandassoc.com STRUCTURAL ENGINEER JQ ENGINEERING 1301 WEST 7TH STREET, SUITE 141 FT. WORTH, TX 76102 (817) 546-7200 http://www.jqeng.com EJ MEP ENGINEER PURDY-MCGUIRE 17300 DALLAS PARKWAY, SUITE 3000 DALLAS, TX 75248 (972) 239-5357 http://www.purdy-mcguire.com EJ IT/AV 4b TECHNOLOGY 12600 NORTHBOROUGH DRIVE, SUITE 290 HOUSTON, TX 77067 (832) 249-9379 http://4btechnology.com/ EJ EJ EJ EJ EJ FOODSERVICE DESIGN EJ EJ EJ EJ BAKERGROUP 2220 EAST PARIS AVENUE SE. GRAND RAPIDS, MI 49546 (800) 968-4011 http://bakergroup.com EJ EJ EJ EJ EJ TEXAS A&M UNIVERSITY WEST CAMPUS SUPPORT BUILDING #02-3177 COLLEGE STATION, TEXAS 77843 KEY PLAN D A C B E REVISIONS ISSUE: ISSUE FOR BID ISSUE DATE: JULY 21, 2016 SHEET NAME: HARDSCAPE MATERIALS PLAN BASE BID SHEET NUMBER: L1.01 COPYRIGHT © 2015 KSQ ARCHITECTS, PC EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ VAN EJ EJ EJ EJ EJ EJ VAN 301 TARROW STREET, 7th FLOOR COLLEGE STATION, TX 77840 (979) 458-7000 http://www.tamus.edu/business/facilities-planningconstruction/ EJ EJ EJ EJ H.C. TEXAS A&M UNIVERSITY SYSTEM OFFICE OF FACILITIES, PLANNING, AND CONSTRUCTION EJ EJ EJ EJ EJ H.C. EJ EJ EJ EJ EJ EJ EJ EJ EJ KSQ ARCHITECTS, PC STUDY COLLABORATE DESIGN COLORADO OKLAHOMA NEW YORK NORTH CAROLINA TEXAS EJ 1452 HUGHES RD., SUITE 150 GRAPEVINE, TX 76051 (972) 259-8500 http://www.ksqarchitects.com CONSULTANTS EJ CIVIL JQ ENGINEERING 2105 COMMERCE STREET DALLAS, TX 75201 (214) 752-9098 http://www.jqeng.com EJ LANDSCAPE ARCHITECT COLEMAN AND ASSOCIATES 9890 SILVER MOUNTAIN DRIVE AUSTIN, TX 78739 (512) 476-2090 http://www.colemanandassoc.com STRUCTURAL ENGINEER JQ ENGINEERING 1301 WEST 7TH STREET, SUITE 141 FT. WORTH, TX 76102 (817) 546-7200 http://www.jqeng.com EJ MEP ENGINEER PURDY-MCGUIRE 17300 DALLAS PARKWAY, SUITE 3000 DALLAS, TX 75248 (972) 239-5357 http://www.purdy-mcguire.com EJ IT/AV 4b TECHNOLOGY 12600 NORTHBOROUGH DRIVE, SUITE 290 HOUSTON, TX 77067 (832) 249-9379 http://4btechnology.com/ EJ EJ EJ EJ FOODSERVICE DESIGN EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ BAKERGROUP 2220 EAST PARIS AVENUE SE. GRAND RAPIDS, MI 49546 (800) 968-4011 http://bakergroup.com EJ EJ EJ EJ EJ EJ EJ EJ TEXAS A&M UNIVERSITY WEST CAMPUS SUPPORT BUILDING #02-3177 COLLEGE STATION, TEXAS 77843 KEY PLAN EJ EJ EJ EJ D EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ A C B E REVISIONS ISSUE: ISSUE FOR BID ISSUE DATE: JULY 21, 2016 SHEET NAME: HARDSCAPE MATERIALS PLAN ALTERNATE BID SHEET NUMBER: L1.01A COPYRIGHT © 2015 KSQ ARCHITECTS, PC EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ 301 TARROW STREET, 7th FLOOR COLLEGE STATION, TX 77840 (979) 458-7000 http://www.tamus.edu/business/facilities-planningconstruction/ EJ EJ EJ EJ EJ EJ TEXAS A&M UNIVERSITY SYSTEM OFFICE OF FACILITIES, PLANNING, AND CONSTRUCTION EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ KSQ ARCHITECTS, PC STUDY COLLABORATE DESIGN COLORADO OKLAHOMA NEW YORK NORTH CAROLINA TEXAS EJ EJ EJ EJ EJ 1452 HUGHES RD., SUITE 150 GRAPEVINE, TX 76051 (972) 259-8500 http://www.ksqarchitects.com EJ CONSULTANTS EJ EJ EJ CIVIL JQ ENGINEERING 2105 COMMERCE STREET DALLAS, TX 75201 (214) 752-9098 http://www.jqeng.com LANDSCAPE ARCHITECT COLEMAN AND ASSOCIATES 9890 SILVER MOUNTAIN DRIVE AUSTIN, TX 78739 (512) 476-2090 http://www.colemanandassoc.com STRUCTURAL ENGINEER JQ ENGINEERING 1301 WEST 7TH STREET, SUITE 141 FT. WORTH, TX 76102 (817) 546-7200 http://www.jqeng.com EJ MEP ENGINEER PURDY-MCGUIRE 17300 DALLAS PARKWAY, SUITE 3000 DALLAS, TX 75248 (972) 239-5357 http://www.purdy-mcguire.com IT/AV 4b TECHNOLOGY 12600 NORTHBOROUGH DRIVE, SUITE 290 HOUSTON, TX 77067 (832) 249-9379 http://4btechnology.com/ EJ FOODSERVICE DESIGN BAKERGROUP 2220 EAST PARIS AVENUE SE. GRAND RAPIDS, MI 49546 (800) 968-4011 http://bakergroup.com EJ EJ EJ EJ EJ EJ EJ EJ TEXAS A&M UNIVERSITY WEST CAMPUS SUPPORT BUILDING #02-3177 EJ EJ EJ COLLEGE STATION, TEXAS 77843 KEY PLAN EJ D A EJ C B E REVISIONS EJ EJ ISSUE: EJ ISSUE FOR BID ISSUE DATE: JULY 21, 2016 SHEET NAME: HARDSCAPE LAYOUT AND GRADING PLAN BASE BID SHEET NUMBER: L1.02 COPYRIGHT © 2015 KSQ ARCHITECTS, PC EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ 301 TARROW STREET, 7th FLOOR COLLEGE STATION, TX 77840 (979) 458-7000 http://www.tamus.edu/business/facilities-planningconstruction/ EJ EJ EJ EJ EJ EJ EJ EJ EJ TEXAS A&M UNIVERSITY SYSTEM OFFICE OF FACILITIES, PLANNING, AND CONSTRUCTION EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ KSQ ARCHITECTS, PC STUDY COLLABORATE DESIGN COLORADO OKLAHOMA NEW YORK NORTH CAROLINA TEXAS EJ EJ EJ EJ EJ 1452 HUGHES RD., SUITE 150 GRAPEVINE, TX 76051 (972) 259-8500 http://www.ksqarchitects.com EJ CONSULTANTS EJ EJ EJ CIVIL JQ ENGINEERING 2105 COMMERCE STREET DALLAS, TX 75201 (214) 752-9098 http://www.jqeng.com LANDSCAPE ARCHITECT COLEMAN AND ASSOCIATES 9890 SILVER MOUNTAIN DRIVE AUSTIN, TX 78739 (512) 476-2090 http://www.colemanandassoc.com STRUCTURAL ENGINEER JQ ENGINEERING 1301 WEST 7TH STREET, SUITE 141 FT. WORTH, TX 76102 (817) 546-7200 http://www.jqeng.com EJ MEP ENGINEER PURDY-MCGUIRE 17300 DALLAS PARKWAY, SUITE 3000 DALLAS, TX 75248 (972) 239-5357 http://www.purdy-mcguire.com IT/AV 4b TECHNOLOGY 12600 NORTHBOROUGH DRIVE, SUITE 290 HOUSTON, TX 77067 (832) 249-9379 http://4btechnology.com/ EJ FOODSERVICE DESIGN BAKERGROUP 2220 EAST PARIS AVENUE SE. GRAND RAPIDS, MI 49546 (800) 968-4011 http://bakergroup.com EJ EJ EJ EJ EJ EJ EJ TEXAS A&M UNIVERSITY WEST CAMPUS SUPPORT BUILDING #02-3177 EJ EJ COLLEGE STATION, TEXAS 77843 KEY PLAN EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ D A EJ EJ EJ EJ C B E REVISIONS EJ ISSUE: ISSUE FOR BID ISSUE DATE: JULY 21, 2016 SHEET NAME: HARDSCAPE LAYOUT AND GRADING PLAN ALTERNATE BID SHEET NUMBER: L1.02A COPYRIGHT © 2015 KSQ ARCHITECTS, PC TEXAS A&M UNIVERSITY SYSTEM OFFICE OF FACILITIES, PLANNING, AND CONSTRUCTION 301 TARROW STREET, 7th FLOOR COLLEGE STATION, TX 77840 (979) 458-7000 http://www.tamus.edu/business/facilities-planningconstruction/ KSQ ARCHITECTS, PC STUDY COLLABORATE DESIGN COLORADO OKLAHOMA NEW YORK NORTH CAROLINA TEXAS 1452 HUGHES RD., SUITE 150 GRAPEVINE, TX 76051 (972) 259-8500 http://www.ksqarchitects.com CONSULTANTS CIVIL JQ ENGINEERING 2105 COMMERCE STREET DALLAS, TX 75201 (214) 752-9098 http://www.jqeng.com LANDSCAPE ARCHITECT COLEMAN AND ASSOCIATES 9890 SILVER MOUNTAIN DRIVE AUSTIN, TX 78739 (512) 476-2090 http://www.colemanandassoc.com STRUCTURAL ENGINEER JQ ENGINEERING 1301 WEST 7TH STREET, SUITE 141 FT. WORTH, TX 76102 (817) 546-7200 http://www.jqeng.com MEP ENGINEER PURDY-MCGUIRE 17300 DALLAS PARKWAY, SUITE 3000 DALLAS, TX 75248 (972) 239-5357 http://www.purdy-mcguire.com IT/AV 4b TECHNOLOGY 12600 NORTHBOROUGH DRIVE, SUITE 290 HOUSTON, TX 77067 (832) 249-9379 http://4btechnology.com/ FOODSERVICE DESIGN BAKERGROUP 2220 EAST PARIS AVENUE SE. GRAND RAPIDS, MI 49546 (800) 968-4011 http://bakergroup.com TEXAS A&M UNIVERSITY WEST CAMPUS SUPPORT BUILDING #02-3177 COLLEGE STATION, TEXAS 77843 KEY PLAN D A C B E REVISIONS ISSUE: ISSUE FOR BID ISSUE DATE: JULY 21, 2016 SHEET NAME: HARDSCAPE DETAILS SHEET NUMBER: L1.10 COPYRIGHT © 2015 KSQ ARCHITECTS, PC TEXAS A&M UNIVERSITY SYSTEM OFFICE OF FACILITIES, PLANNING, AND CONSTRUCTION 301 TARROW STREET, 7th FLOOR COLLEGE STATION, TX 77840 (979) 458-7000 http://www.tamus.edu/business/facilities-planningconstruction/ KSQ ARCHITECTS, PC STUDY COLLABORATE DESIGN COLORADO OKLAHOMA NEW YORK NORTH CAROLINA TEXAS 1452 HUGHES RD., SUITE 150 GRAPEVINE, TX 76051 (972) 259-8500 http://www.ksqarchitects.com CONSULTANTS CIVIL JQ ENGINEERING 2105 COMMERCE STREET DALLAS, TX 75201 (214) 752-9098 http://www.jqeng.com LANDSCAPE ARCHITECT COLEMAN AND ASSOCIATES 9890 SILVER MOUNTAIN DRIVE AUSTIN, TX 78739 (512) 476-2090 http://www.colemanandassoc.com STRUCTURAL ENGINEER JQ ENGINEERING 1301 WEST 7TH STREET, SUITE 141 FT. WORTH, TX 76102 (817) 546-7200 http://www.jqeng.com MEP ENGINEER PURDY-MCGUIRE 17300 DALLAS PARKWAY, SUITE 3000 DALLAS, TX 75248 (972) 239-5357 http://www.purdy-mcguire.com IT/AV 4b TECHNOLOGY 12600 NORTHBOROUGH DRIVE, SUITE 290 HOUSTON, TX 77067 (832) 249-9379 http://4btechnology.com/ FOODSERVICE DESIGN BAKERGROUP 2220 EAST PARIS AVENUE SE. GRAND RAPIDS, MI 49546 (800) 968-4011 http://bakergroup.com TEXAS A&M UNIVERSITY WEST CAMPUS SUPPORT BUILDING #02-3177 COLLEGE STATION, TEXAS 77843 KEY PLAN D A C B E REVISIONS ISSUE: ISSUE FOR BID ISSUE DATE: JULY 21, 2016 SHEET NAME: HARDSCAPE DETAILS SHEET NUMBER: L1.11 COPYRIGHT © 2015 KSQ ARCHITECTS, PC TEXAS A&M UNIVERSITY SYSTEM OFFICE OF FACILITIES, PLANNING, AND CONSTRUCTION 301 TARROW STREET, 7th FLOOR COLLEGE STATION, TX 77840 (979) 458-7000 http://www.tamus.edu/business/facilities-planningconstruction/ KSQ ARCHITECTS, PC STUDY COLLABORATE DESIGN COLORADO OKLAHOMA NEW YORK NORTH CAROLINA TEXAS 1452 HUGHES RD., SUITE 150 GRAPEVINE, TX 76051 (972) 259-8500 http://www.ksqarchitects.com CONSULTANTS CIVIL JQ ENGINEERING 2105 COMMERCE STREET DALLAS, TX 75201 (214) 752-9098 http://www.jqeng.com LANDSCAPE ARCHITECT COLEMAN AND ASSOCIATES 9890 SILVER MOUNTAIN DRIVE AUSTIN, TX 78739 (512) 476-2090 http://www.colemanandassoc.com STRUCTURAL ENGINEER JQ ENGINEERING 1301 WEST 7TH STREET, SUITE 141 FT. WORTH, TX 76102 (817) 546-7200 http://www.jqeng.com MEP ENGINEER PURDY-MCGUIRE 17300 DALLAS PARKWAY, SUITE 3000 DALLAS, TX 75248 (972) 239-5357 http://www.purdy-mcguire.com IT/AV 4b TECHNOLOGY 12600 NORTHBOROUGH DRIVE, SUITE 290 HOUSTON, TX 77067 (832) 249-9379 http://4btechnology.com/ FOODSERVICE DESIGN BAKERGROUP 2220 EAST PARIS AVENUE SE. GRAND RAPIDS, MI 49546 (800) 968-4011 http://bakergroup.com TEXAS A&M UNIVERSITY WEST CAMPUS SUPPORT BUILDING #02-3177 COLLEGE STATION, TEXAS 77843 KEY PLAN D A C B E REVISIONS WHITE CREEK COMMUNITY CENTER ISSUE: ISSUE FOR BID ISSUE DATE: JULY 21, 2016 SHEET NAME: HARDSCAPE DETAILS SHEET NUMBER: L1.12 COPYRIGHT © 2015 KSQ ARCHITECTS, PC EJ EJ EJ EJ EJ EJ EJ EJ EJ TEXAS A&M UNIVERSITY SYSTEM OFFICE OF FACILITIES, PLANNING, AND CONSTRUCTION 301 TARROW STREET, 7th FLOOR COLLEGE STATION, TX 77840 (979) 458-7000 http://www.tamus.edu/business/facilities-planningconstruction/ KSQ ARCHITECTS, PC STUDY COLLABORATE DESIGN COLORADO OKLAHOMA NEW YORK NORTH CAROLINA TEXAS 1452 HUGHES RD., SUITE 150 GRAPEVINE, TX 76051 (972) 259-8500 http://www.ksqarchitects.com CONSULTANTS CIVIL JQ ENGINEERING 2105 COMMERCE STREET DALLAS, TX 75201 (214) 752-9098 http://www.jqeng.com LANDSCAPE ARCHITECT COLEMAN AND ASSOCIATES 9890 SILVER MOUNTAIN DRIVE AUSTIN, TX 78739 (512) 476-2090 http://www.colemanandassoc.com STRUCTURAL ENGINEER JQ ENGINEERING 1301 WEST 7TH STREET, SUITE 141 FT. WORTH, TX 76102 (817) 546-7200 http://www.jqeng.com MEP ENGINEER PURDY-MCGUIRE 17300 DALLAS PARKWAY, SUITE 3000 DALLAS, TX 75248 (972) 239-5357 http://www.purdy-mcguire.com IT/AV EJ 4b TECHNOLOGY 12600 NORTHBOROUGH DRIVE, SUITE 290 HOUSTON, TX 77067 (832) 249-9379 http://4btechnology.com/ FOODSERVICE DESIGN BAKERGROUP 2220 EAST PARIS AVENUE SE. GRAND RAPIDS, MI 49546 (800) 968-4011 http://bakergroup.com EJ TEXAS A&M UNIVERSITY WEST CAMPUS SUPPORT BUILDING #02-3177 COLLEGE STATION, TEXAS 77843 KEY PLAN D A C B E REVISIONS ISSUE: ISSUE FOR BID ISSUE DATE: JULY 21, 2016 SHEET NAME: LANDSCAPE PLAN BASE BID SHEET NUMBER: L2.01 COPYRIGHT © 2015 KSQ ARCHITECTS, PC TEXAS A&M UNIVERSITY SYSTEM OFFICE OF FACILITIES, PLANNING, AND CONSTRUCTION 301 TARROW STREET, 7th FLOOR COLLEGE STATION, TX 77840 (979) 458-7000 http://www.tamus.edu/business/facilities-planningconstruction/ KSQ ARCHITECTS, PC STUDY COLLABORATE DESIGN COLORADO OKLAHOMA NEW YORK NORTH CAROLINA TEXAS 1452 HUGHES RD., SUITE 150 GRAPEVINE, TX 76051 (972) 259-8500 http://www.ksqarchitects.com CONSULTANTS CIVIL JQ ENGINEERING 2105 COMMERCE STREET DALLAS, TX 75201 (214) 752-9098 http://www.jqeng.com LANDSCAPE ARCHITECT COLEMAN AND ASSOCIATES 9890 SILVER MOUNTAIN DRIVE AUSTIN, TX 78739 (512) 476-2090 http://www.colemanandassoc.com STRUCTURAL ENGINEER JQ ENGINEERING 1301 WEST 7TH STREET, SUITE 141 FT. WORTH, TX 76102 (817) 546-7200 http://www.jqeng.com MEP ENGINEER PURDY-MCGUIRE 17300 DALLAS PARKWAY, SUITE 3000 DALLAS, TX 75248 (972) 239-5357 http://www.purdy-mcguire.com IT/AV 4b TECHNOLOGY 12600 NORTHBOROUGH DRIVE, SUITE 290 HOUSTON, TX 77067 (832) 249-9379 http://4btechnology.com/ FOODSERVICE DESIGN BAKERGROUP 2220 EAST PARIS AVENUE SE. GRAND RAPIDS, MI 49546 (800) 968-4011 http://bakergroup.com TEXAS A&M UNIVERSITY WEST CAMPUS SUPPORT BUILDING #02-3177 COLLEGE STATION, TEXAS 77843 KEY PLAN D A C B E REVISIONS ISSUE: ISSUE FOR BID ISSUE DATE: JULY 21, 2016 SHEET NAME: LANDSCAPE PLAN ALTERNATE BID SHEET NUMBER: L2.01A COPYRIGHT © 2015 KSQ ARCHITECTS, PC TEXAS A&M UNIVERSITY SYSTEM OFFICE OF FACILITIES, PLANNING, AND CONSTRUCTION 301 TARROW STREET, 7th FLOOR COLLEGE STATION, TX 77840 (979) 458-7000 http://www.tamus.edu/business/facilities-planningconstruction/ KSQ ARCHITECTS, PC STUDY COLLABORATE DESIGN COLORADO OKLAHOMA NEW YORK NORTH CAROLINA TEXAS 1452 HUGHES RD., SUITE 150 GRAPEVINE, TX 76051 (972) 259-8500 http://www.ksqarchitects.com CONSULTANTS CIVIL JQ ENGINEERING 2105 COMMERCE STREET DALLAS, TX 75201 (214) 752-9098 http://www.jqeng.com LANDSCAPE ARCHITECT COLEMAN AND ASSOCIATES 9890 SILVER MOUNTAIN DRIVE AUSTIN, TX 78739 (512) 476-2090 http://www.colemanandassoc.com STRUCTURAL ENGINEER JQ ENGINEERING 1301 WEST 7TH STREET, SUITE 141 FT. WORTH, TX 76102 (817) 546-7200 http://www.jqeng.com MEP ENGINEER PURDY-MCGUIRE 17300 DALLAS PARKWAY, SUITE 3000 DALLAS, TX 75248 (972) 239-5357 http://www.purdy-mcguire.com IT/AV 4b TECHNOLOGY 12600 NORTHBOROUGH DRIVE, SUITE 290 HOUSTON, TX 77067 (832) 249-9379 http://4btechnology.com/ FOODSERVICE DESIGN BAKERGROUP 2220 EAST PARIS AVENUE SE. GRAND RAPIDS, MI 49546 (800) 968-4011 http://bakergroup.com TEXAS A&M UNIVERSITY WEST CAMPUS SUPPORT BUILDING #02-3177 COLLEGE STATION, TEXAS 77843 KEY PLAN D A C B E REVISIONS ISSUE: ISSUE FOR BID ISSUE DATE: JULY 21, 2016 SHEET NAME: LANDSCAPE DETAILS SHEET NUMBER: L2.10 COPYRIGHT © 2015 KSQ ARCHITECTS, PC NOTE A: POINT OF CONNECTION (POC) #1 SHALL BE DOWNSTREAM OF A 2" DOMESTIC WATER METER AND 2" BACKFLOW PROVIDED BY OTHERS. BACKFLOW AND METER TO BE LOCATED IN MECHANICAL ROOM AND A 2-1/2" IRRIGATION WATER LINE WILL BE CARRIED OUT TO THE INDICATED LOCATION OM THE PLAN. SEE SHEET MEP 1.01, MEP SITE PLAN, FOR CONNECTION LOCATION AND DETAILS. THE CONTRACTOR SHALL VERIFY THE ACTUAL LOCATION, WATER TYPE, METER SIZE AND WATER PRESSURE IN THE FIELD PRIOR TO STARTING WORK. MEASUREMENT OF THE STATIC (NO WATER MOVING) WATER PRESSURE IS ACCEPTABLE FOR POTABLE WATER SYSTEMS WHERE NO PUMP HAS BEEN INDICATED ON THESE PLANS. WHEN USING RECYCLED WATER, OR ON POTABLE WATER SYSTEMS REQUIRING A PUMP, ONLY THE MEASUREMENT OF DYNAMIC (WATER MOVING THROUGH THE METER) WATER PRESSURE, SHALL BE ACCEPTABLE. THE DYNAMIC WATER PRESSURE SHALL BE MEASURED AT THE MAXIMUM SYSTEM DEMAND AS INDICATED BELOW. IF ANY OF THE POC INFORMATION SHOWN ON THESE DRAWING IS FOUND TO BE DIFFERENT THAN THE ACTUAL POC INFORMATION GATHERED IN THE FIELD, IMMEDIATELY NOTIFY THE LANDSCAPE ARCHITECT AND IRRIGATION CONSULTANT. SHOULD THE CONTRACTOR FAIL TO VERIFY THE POC INFORMATION AS SHOWN HEREIN, ANY CHANGES REQUIRED BY LOW PRESSURE OR VOLUME SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. WATER PRESSURE AT POC: DESIGN WATER PRESSURE: MAXIMUM SYSTEM DEMAND: RESIDUAL WATER PRESSURE: 65 61 45 4 PSI (STATIC / DYNAMIC) PSI GPM PSI NOTE B: CONTROLLER "A" SHALL BE OF THE BRAND, MODEL AND STATION SIZE AS INDICATED ON THE IRRIGATION MATERIALS LEGEND. THE CONTROLLER SHALL BE INSTALLED IN THE APPROXIMATE LOCATION SHOWN. THE CONTRACTOR SHALL COORDINATE THE REQUIRED ELECTRICAL POWER SUPPLY AT THIS LOCATION WITH THE OWNER'S AUTHORIZED REPRESENTATIVE. FINAL LOCATION OF CONTROLLER AND ELECTRICAL POINT OF CONNECTION SHALL BE CONFIRMED WITH OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO STARTING WORK. NOTE C: THESE PLANS ARE DIAGRAMMATIC, THE MAINLINE AND RELATED IRRIGATION EQUIPMENT IS SHOWN WITHIN THE PAVING FOR CLARITY ONLY. THE ACTUAL LOCATION OF MAINLINE AND RELATED IRRIGATION EQUIPMENT SHALL BE WITHIN PLANTER AND A MINIMUM OF 18" OFF ADJACENT HARDSCAPE AND OTHER OBSTACLES, TYPICAL. NOTE D: CONTRACTOR SHALL ADJUST ALL HEADS AS REQUIRED TO ACCOMMODATE ANY VERTICAL OBSTRUCTIONS THAT MAY OCCUR IN THE LANDSCAPE, INCLUDING BUT NOT LIMITED TO LIGHT POLES, FIRE HYDRANTS, TREES, ETC. WHEN A SLIGHT RELOCATION OF THE HEAD IS NOT SUFFICIENT TO CLEAR THE OBSTACLE, OR IF IT NEGATIVELY AFFECTS THE COVERAGE, AN ADDITIONAL HEAD SHALL BE INSTALLED TO PLACE ONE HEAD ON EITHER SIDE OF THE OBSTACLE. THE NOZZLES OF THESE TWO HEADS SHALL HAVE ARC PATTERNS THAT ADD UP TO THE ORIGINAL ARC PATTERN OF THE HEAD INDICATED ON THE PLANS. THE CONTRACTOR SHALL VERIFY ALL HEAD LAYOUT WITH OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO STARTING WORK. IRRIGATION CONTROLLER "A"; REFER TO NOTE "B" NOTE E: THESE PLANS ARE DIAGRAMMATIC, TREE BUBBLERS AND LATERAL LINES ARE SHOWN WITHIN THE PAVING FOR CLARITY ONLY, THE ACTUAL LOCATIONS SHALL BE WITHIN THE PLANTER. THE TREE BUBBLERS SHALL BE ALIGNED WITH TREES AS SHOWN ON THE PLANTING PLANS, AND AS DIRECTED BY OWNER'S AUTHORIZED REPRESENTATIVE. THE CONTRACTOR SHALL CONFIRM ALL LAYOUT IN FIELD WITH OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO STARTING WORK. TEXAS A&M UNIVERSITY SYSTEM OFFICE OF FACILITIES, PLANNING, AND CONSTRUCTION 301 TARROW STREET, 7th FLOOR COLLEGE STATION, TX 77840 (979) 458-7000 http://www.tamus.edu/business/facilities-planningconstruction/ KSQ ARCHITECTS, PC STUDY COLLABORATE DESIGN COLORADO OKLAHOMA NEW YORK NORTH CAROLINA TEXAS 1452 HUGHES RD., SUITE 150 GRAPEVINE, TX 76051 (972) 259-8500 http://www.ksqarchitects.com CONSULTANTS CIVIL JQ ENGINEERING 2105 COMMERCE STREET DALLAS, TX 75201 (214) 752-9098 http://www.jqeng.com LANDSCAPE ARCHITECT COLEMAN AND ASSOCIATES 9890 SILVER MOUNTAIN DRIVE AUSTIN, TX 78739 (512) 476-2090 http://www.colemanandassoc.com STRUCTURAL ENGINEER JQ ENGINEERING 1301 WEST 7TH STREET, SUITE 141 FT. WORTH, TX 76102 (817) 546-7200 http://www.jqeng.com MEP ENGINEER PURDY-MCGUIRE 17300 DALLAS PARKWAY, SUITE 3000 DALLAS, TX 75248 (972) 239-5357 http://www.purdy-mcguire.com IRRIGATION POINT OF CONNECTION #1; REFER TO NOTE "A" IT/AV 4b TECHNOLOGY 12600 NORTHBOROUGH DRIVE, SUITE 290 HOUSTON, TX 77067 (832) 249-9379 http://4btechnology.com/ FOODSERVICE DESIGN OF TE XA TE TA S S BAKERGROUP 2220 EAST PARIS AVENUE SE. GRAND RAPIDS, MI 49546 (800) 968-4011 http://bakergroup.com LI C E N TO R EDWARD J. KOCHANEK SE D I RR IG A 21 JULY 2016 TEXAS A&M UNIVERSITY WEST CAMPUS SUPPORT BUILDING #02-3177 COLLEGE STATION, TEXAS 77843 KEY PLAN REVISIONS BASE BID: TEMPORARY IRRIGATION IN THIS AREA. BID ALTERNATE # 4 IS PERMANENT IRRIGATION IN THIS AREA. ISSUE: ISSUE FOR BID ISSUE DATE: JULY 21, 2016 SHEET NAME: BASE BID: TEMPORARY IRRIGATION IN THIS AREA. BID ALTERNATE # 4 IS PERMANENT IRRIGATION IN THIS AREA. IRRIGATION PLAN BASE BID SHEET NUMBER: L3.01 NOTE A: BID ALTERNATE #7 ALTERNATE POINT OF CONNECTION (POC) SHALL BE A RAIN-WATER AND CONDENSATE REUSE TANK (20,000 GALLON). THE CONTRACTOR SHALL VERIFY THE ACTUAL LOCATION, SIZE AND WATER PRESSURE IN THE FIELD PRIOR TO STARTING WORK. MEASUREMENT OF THE STATIC (NO WATER MOVING) WATER PRESSURE IS ACCEPTABLE FOR POTABLE WATER SYSTEMS WHERE NO PUMP HAS BEEN INDICATED ON THESE PLANS. WHEN USING RECYCLED WATER, OR ON POTABLE WATER SYSTEMS REQUIRING A PUMP, ONLY THE MEASUREMENT OF DYNAMIC (WATER MOVING THROUGH THE METER) WATER PRESSURE, SHALL BE ACCEPTABLE. THE DYNAMIC WATER PRESSURE SHALL BE MEASURED AT THE MAXIMUM SYSTEM DEMAND AS INDICATED BELOW. IF ANY OF THE POC INFORMATION SHOWN ON THESE DRAWING IS FOUND TO BE DIFFERENT THAN THE ACTUAL POC INFORMATION GATHERED IN THE FIELD, IMMEDIATELY NOTIFY THE LANDSCAPE ARCHITECT AND IRRIGATION CONSULTANT. SHOULD THE CONTRACTOR FAIL TO VERIFY THE POC INFORMATION AS SHOWN HEREIN, ANY CHANGES REQUIRED BY LOW PRESSURE OR VOLUME SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. BID ALTERNATE #7 SHALL INCLUDE THE 2-1/2" MAKE-UP WATER LINE BETWEEN THE BACKFLOW PREVENTER AND THE WATER TANK. IF BID ALTERNATE #7 IS NOT ACCEPTED, IRRIGATION POINT OF CONNECTION SHALL BE INSTALLED PER BASE BID PLANS. DESIGN WATER PRESSURE: MAXIMUM SYSTEM DEMAND: PRESSURE BOOST REQUIRED: 60 45 65 PSI GPM PSI NOTE B: CONTROLLER "A" SHALL BE OF THE BRAND, MODEL AND STATION SIZE AS INDICATED ON THE IRRIGATION MATERIALS LEGEND. THE CONTROLLER SHALL BE INSTALLED IN THE APPROXIMATE LOCATION SHOWN. THE CONTRACTOR SHALL COORDINATE THE REQUIRED ELECTRICAL POWER SUPPLY AT THIS LOCATION WITH THE OWNER'S AUTHORIZED REPRESENTATIVE. FINAL LOCATION OF CONTROLLER AND ELECTRICAL POINT OF CONNECTION SHALL BE CONFIRMED WITH OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO STARTING WORK. NOTE C: THESE PLANS ARE DIAGRAMMATIC, THE MAINLINE AND RELATED IRRIGATION EQUIPMENT IS SHOWN WITHIN THE PAVING FOR CLARITY ONLY. THE ACTUAL LOCATION OF MAINLINE AND RELATED IRRIGATION EQUIPMENT SHALL BE WITHIN PLANTER AND A MINIMUM OF 18" OFF ADJACENT HARDSCAPE AND OTHER OBSTACLES, TYPICAL. NOTE D: CONTRACTOR SHALL ADJUST ALL HEADS AS REQUIRED TO ACCOMMODATE ANY VERTICAL OBSTRUCTIONS THAT MAY OCCUR IN THE LANDSCAPE, INCLUDING BUT NOT LIMITED TO LIGHT POLES, FIRE HYDRANTS, TREES, ETC. WHEN A SLIGHT RELOCATION OF THE HEAD IS NOT SUFFICIENT TO CLEAR THE OBSTACLE, OR IF IT NEGATIVELY AFFECTS THE COVERAGE, AN ADDITIONAL HEAD SHALL BE INSTALLED TO PLACE ONE HEAD ON EITHER SIDE OF THE OBSTACLE. THE NOZZLES OF THESE TWO HEADS SHALL HAVE ARC PATTERNS THAT ADD UP TO THE ORIGINAL ARC PATTERN OF THE HEAD INDICATED ON THE PLANS. THE CONTRACTOR SHALL VERIFY ALL HEAD LAYOUT WITH OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO STARTING WORK. IRRIGATION CONTROLLER "A"; REFER TO NOTE "B" NOTE E: THESE PLANS ARE DIAGRAMMATIC, TREE BUBBLERS AND LATERAL LINES ARE SHOWN WITHIN THE PAVING FOR CLARITY ONLY, THE ACTUAL LOCATIONS SHALL BE WITHIN THE PLANTER. THE TREE BUBBLERS SHALL BE ALIGNED WITH TREES AS SHOWN ON THE PLANTING PLANS, AND AS DIRECTED BY OWNER'S AUTHORIZED REPRESENTATIVE. THE CONTRACTOR SHALL CONFIRM ALL LAYOUT IN FIELD WITH OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO STARTING WORK. WATER COLLECTION SYSTEM (BID ALTERNATE #7) DESCRIPTION OF OPERATION: VENT AND MANWAY COVER, SEE DETAILING AT RIGHT. (BID ALTERNATE #7) CONNECT TO 2-1/2" IRRIGATION WATER LINE FOR RAIN WATER TANK DOMESTIC FILL LINE. (BID ALTERNATE #7) PUMP WILL START VIA PRESSURE DROP SENSED IN WATER MAINLINE AND REGULATE A CONSTANT PRESSURE AT VARIABLE FLOW RATE. PUMP WILL RETIRE BASED UPON AN ADJUSTABLE MINIMUM WATER DEMAND (FLOW) AND SUSTAINED REGULATE PRESSURE. WATER WILL BE DRAWN OUT OF TANK. ONCE USER ADJUSTABLE LEVEL SET POINT IS SATISFIED THE AUTOMATIC VALVE WILL SWITCH TO CITY WATER AND THE PUMP WILL SHUT DOWN. VALVE WILL ALSO BE ENGAGED WHENEVER PUMP IS DISABLED VIA ALARM OR IN THE OFF POSITION. A MANUAL OVER RIDE BUTTON WILL ALSO BE LOCATED ON THE OPERATOR INTERFACE. VALVE WILL SWITCH BACK TO TANK WATER WHEN LEVEL RISES ABOVE USER ADJUSTABLE SET POINT. AUTOMATIC SWITCH TO CITY WATER UPON A POWER FAILURE IS AN AVAILABLE OPTION, SEE QUOTE FOR INCLUSION. WIRE SCHDULE: LEVEL SENSOR: 18 AWG (2) COND. SHIELDED 500FT MAX LEVEL FLOAT: 14 AWG (2) COND. FLOW SENSOR: 18 AWG (2) COND. SHIELDED 500FT MAX SOLENOID VALVE: 14 AWG (2) COND. MOTOR: 10 AWG (3) COND. W/ GROUND WATERTRONICS RECOMMENDS THAT MAKEUP WATER BE GREATER THAN OR EQUAL TO THE MAXIMUM DEMAND OF THE PUMP STATION T CLEAN WATER INLET OWNER RESPONSIBLE FOR CITY WATER METER, BACK FLOW PREVENTER AND ANY OTHER REGULATING DEVICES THAT MAY BE REQUIRED. OWNER RESPONSIBLE FOR VERIFYING CITY WATER CAPACITY MUST SUPPLY A MIN 45 GPM TO TANK. 46" 321" 2 SLAB 2" MPT ANCHOR POINT SEE DETAIL 1 482" BASE & SLAB DETAIL FLOW 36" DETAIL B: POTABLE TANK FILL SPOOL INSTALL IN MECHANICAL ROOM OR WATERPROOF VALVE BOX HIGH VOLTAGE POWER CONDUIT 42" MIN. SEE LOCAL NEC CODE 50" BASE 1" BLOW OUT PORT w/ PLUG E OUTER DISCONNECT VFD 34" BASE D R COLEMAN AND ASSOCIATES 9890 SILVER MOUNTAIN DRIVE AUSTIN, TX 78739 (512) 476-2090 http://www.colemanandassoc.com JQ ENGINEERING 1301 WEST 7TH STREET, SUITE 141 FT. WORTH, TX 76102 (817) 546-7200 http://www.jqeng.com MEP ENGINEER PURDY-MCGUIRE 17300 DALLAS PARKWAY, SUITE 3000 DALLAS, TX 75248 (972) 239-5357 http://www.purdy-mcguire.com IT/AV 46" SLAB 3/4" MPT PRV DISCHARGE TO OPEN DRAIN DETAIL "A" CONCRETE ANCHOR TYPICAL (4) LOCATIONS J-BOX FOR REMOTE WIRING FROM TANK DUST COVER S H MANWAY COVER BY INSTALLATION CONTRACTOR LOW VOLTAGE WIRE AND CONDUIT TO CONTROL PANEL BY INSTALLATION CONRACTOR DO NOT RUN HIGH & LOW VOLTAGE IN THE SAME CONDUIT D CONTROL BOX E F 385 8" VFD N 24" BURY 24" BURY 203 4" BURY P W M X INNER CONTROL BOX EDWARD J. KOCHANEK J 2" PRESSURE RATED PIPING BY INSTALLATION CONTRACTOR THRUST BLOCK 2" MPT DISCHARGE CONNECTION L ENCLOSURE ISOMETRIC VIEW LI 10'-0" 15" LOW LEVEL ALARM PUMP OFF / 3-WAY VALVE OPEN RE-SET @ + 2" C U ZIP TIE MOTOR LEADS TO DISCHARGE HOSE Q B 37'-8 3/4" SCALE: NONE DESCRIPTION SE D I RR IG A TEXAS A&M UNIVERSITY WEST CAMPUS SUPPORT BUILDING #02-3177 K GRAVEL BACK FILL AROUND TANK TO SUB GRADE, SEE INSTALLATION INSTRUCTIONS FOR PROPER INSTALLATION & WARRANTY BY N 21 JULY 2016 13" LOW LOW LEVEL HARD SHUT DOWN A E C DISTANCE BETWEEN CONTROL PANEL & MOTOR IN TANK NOT TO EXCEED 100 FEET V OF TE XA TE TA S CONTROL PANEL TO INCLUDE: -COLOR TOUCHSCREEN OPERATOR INTERFACE 4" PVC CONNECTION FOR TANK VENT, VENT PIPE w/ RODENT SCREEN -FILTER CONTROLS AND DISPLAY BY INSTALLATION CONTRACTOR -FLOW SENSOR DISPLAY AND TOTALIZERS -PSI DISPLAY AND SET POINTS -AUTO RE-ENABLING OF PUMP BASED UPON WATER AVAILABILITY FINISHED GRADE ??? ELEV. (LANDSCAPE OR PAVING?) -PUMP RUNNING STATUS & RUN-TIME HRS 12" -LEVEL CONTROLS AND DISPLAY IN "INCHES" & "GALLONS" -USER ABILITY TO ADJUST ALL SYSTEM PARAMETERS FILL VALVE & FLOW SENSOR ??? BURY DEPTH SEE DETAIL "B" LIFTING LUGS -VFD PRESSURE REGULATION FOR ENERGY EFFICIENCY SUPPLY INLET PIPE ELEVATION TO -BRANCH CIRCUIT PROTECTION WATERTRONICS TO DETERMINE BURY DEPTH WM RPZ DETAIL B CONSULT FACTORY IF OVER 7 FT -U.L. 508 LISTED CONTROL PANEL ASSEMBLY -PROGRAMABLE PLC "programable logic controller" -NON-FUSABLE MAIN DISCONNECT -HOA (hand, off, auto) SWITCH FOR PUMP -SERIAL MODBUS PLC CAPABILITY DATE LANDSCAPE ARCHITECT CONTROL BOX HIGH VOLTAGE WIRE AND CONDUIT TO CONTROL PANEL BY INSTALLATION CONTRACTOR 7 6 5 4 3 2 1 NO. JQ ENGINEERING 2105 COMMERCE STREET DALLAS, TX 75201 (214) 752-9098 http://www.jqeng.com BAKERGROUP 2220 EAST PARIS AVENUE SE. GRAND RAPIDS, MI 49546 (800) 968-4011 http://bakergroup.com F I&O SYSTEM SHALL HAVE THE FOLLOWING ALARMS AT MINIMUM -HIGH DISCHARGE PRESSURE -LOW DISCHARGE PRESSURE -VFD FAULT -LOW LOW LEVEL SHUT DOWN (HARD FAULT) -LOW LEVEL ALARM (SOFT FAULT) FLAPPER STYLE CHECK VALVE BY INSTALLATION CONTRACTOR -FILTER ALARM -PIPE FILL ALARM (SYSTEM CAN NOT PRESSURIZE) -LOSS OF PHASE OR PHASE REVERSAL -HIGH VOLTAGE -LOW VOLTAGE -CONTROL POWER ALARM CIVIL FOODSERVICE DESIGN 62" SLAB V CONSULTANTS 4b TECHNOLOGY 12600 NORTHBOROUGH DRIVE, SUITE 290 HOUSTON, TX 77067 (832) 249-9379 http://4btechnology.com/ BACK OF ENCLOSURE CLEAN WATER FROM FILTER OVERFLOW ALTERNATE IRRIGATION POINT OF CONNECTION; REFER TO NOTE "A" (BID ALTERNATE #7) 4" POWER PENETRATION APPROXIMATE TANK WEIGHT (DRY) = 5700 LBS. PUMP SYSTEM WILL TOTALIZE ALL WATER PUMPED AND ALL CITY MAKE UP WATER USED. PUMP CONTROL PAD AND ENCLOSOURE, SEE DETAILING AT RIGHT (BID ALTERNATE #7) OUTER DISCONNECT G 2" MPT 1452 HUGHES RD., SUITE 150 GRAPEVINE, TX 76051 (972) 259-8500 http://www.ksqarchitects.com STRUCTURAL ENGINEER 62" SLAB 10" CONTROL WIRES AND CONDUITS TO CONTROL PANEL BY INSTALLATION CONTRACTOR SENSOR: 18 AWG (2) CONN. SHEILDED VALVE: 14 AWG (2) CONN. KSQ ARCHITECTS, PC STUDY COLLABORATE DESIGN COLORADO OKLAHOMA NEW YORK NORTH CAROLINA TEXAS TO R RECOMMENDED DISCONNECT: 30 AMP POWER REQUIREMENTS: 460 V, 60 HZ, 3 PH, 15 FLA EXHAUST FAN REQUIREMENTS: 240CFM STATION COMPONENTS: A 5 HP PUMP AND MOTOR B LOW LEVEL FLOAT C PUMP DISCHARGE PIPE D PRESSURE TRANSDUCER w/ GAUGE E PUMP FLOW SENSOR F DISCHARGE ISOLATION VALVE G BACK UP WATER FLOW SENSOR H PAINTED STEEL ENCLOSURE (SANDSTONE) I DEAD FRONT HIGH VOLTAGE DISCONNECT J CHECK VALVE K LEVEL TRANSDUCER L QUICK DISCONNECT M NEMA 4X REMOTE DISCONNECT N NEMA 4X LOW VOLTAGE ELECTRICAL J-BOX O DISCONNECT SWITCH P PAINTED STEEL BASE (SANDSTONE) Q HDPE SLED & FLOW INDUCER SLEEVE FOR MOTOR COOLING R PRESSURE RELIEF VALVE S 240CFM FAN, HOOD MOUNTED T TANK FILL SOLENOID VALVE U PUMP INTAKE SCREEN V 20,000 GAL SKY HARVESTER STORAGE TANK W 2" MPT INTAKE DROP PIPE X 2" MPT DISCHARGE DROP PIPE 301 TARROW STREET, 7th FLOOR COLLEGE STATION, TX 77840 (979) 458-7000 http://www.tamus.edu/business/facilities-planningconstruction/ S PUMP STATION SPECIFICATIONS: NAME: TAMU WATER RE-USE SYSTEM STATION MODEL: SHSTV-1-20K-5-460-3-45-65 STATION TOTAL PERFORMANCE: 45 GPM @ 65 PSI PUMP HORSEPOWER: PUMP NO.1: 5 HP (3600 RPM) TEXAS A&M UNIVERSITY SYSTEM OFFICE OF FACILITIES, PLANNING, AND CONSTRUCTION DRWN BY: THIS DRAWING AND DESIGN, IS THE PROPERTY OF WATERTRONICS AND IS NOT TO BE REPRODUCED IN WHOLE OR PART, NOR EMPLOYED FOR ANY PURPOSE OTHER THAN SPECIFICALLY PERMITTED IN WRITING BY WATERTRONICS. THIS DRAWING LOANED AND SUBJECT TO RETURN ON DEMAND CHK. BY: ___ DATE: __/__/__ --- TITLE: TAMU WATER RE-USE SYSTEM ,TEXAS COLLEGE STATION, TEXAS 77843 KEY PLAN DATE: 03/02/16 DRAWING NO. DRAW-NO: REVISIONS ISSUE: ISSUE FOR BID ISSUE DATE: JULY 21, 2016 SHEET NAME: IRRIGATION PLAN ALTERNATE BID SHEET NUMBER: L3.01A IRRIGATION MATERIAL LEGEND 1. CONTRACTOR SHALL MAINTAIN EXISTING MAINLINES IN WORKING ORDER. COORDINATE ALL INTERRUPTIONS OF OPERATION OF THE EXISTING IRRIGATION TO A MINIMUM. COORDINATE ALL INTERRUPTIONS WITH THE OWNER'S REPRESENTATIVE. B. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL EXISTING IRRIGATION EQUIPMENT DAMAGED DURING CONSTRUCTION AND IF DAMAGED, SHALL REPLACE WITH SAME MANUFACTURER AND MODEL. C. ANY EXISTING IRRIGATION CONTROL VALVES CONNECTED TO EXISTING CONTROLLER SHALL BE RECONNECTED TO EXISTING CONTROLLER. CONFIRM PROPER CONTROLLER OPERATION AND INSTALLATION WITH OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO COMMENCING WORK AND UPON COMPLETION OF WORK. D. E. F. CONTRACTOR SHALL CONFIRM THE EXISTING CONTROLLER MAKE AND MODEL AND SHALL CONFIRM THAT SAID CONTROLLER HAS ADEQUATE OPEN STATIONS TO OPERATE ANY ADJUSTED AND ALL PROPOSED IRRIGATION SYSTEM MODIFICATIONS. NOTIFY OWNER'S AUTHORIZED REPRESENTATIVE SHOULD ANY DISCREPANCIES BE NOTED. CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIR/MODIFICATION/REROUTING OF ALL ADJACENT IRRIGATION SYSTEM EQUIPMENT THAT IS AFFECTED BY NEW CONSTRUCTION IMPROVEMENTS. CONTRACTOR SHALL REPAIR SAID SYSTEMS TO A LIKE NEW MANNER, PROVIDING NO LESS THAN 100% OF HEAD RADIUS COVERAGE IN ALL AREAS WITH SYSTEM LAYOUT AS APPROVED BY OWNER'S AUTHORIZED REPRESENTATIVE. CONTRACTOR SHALL CONFIRM ALL AREAS REQUIRING MODIFICATION WITH OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO BIDDING WORK AND PRIOR TO COMMENCING WORK. CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE REMOVAL AND DISPOSAL OF ALL EXISTING IRRIGATION EQUIPMENT AFFECTED BY THE NEW CONSTRUCTION IMPROVEMENTS, IF NECESSARY. CONTRACTOR SHALL VERIFY ALL EQUIPMENT TO BE REMOVED AND DISPOSED OF IN FIELD PRIOR TO BIDDING WORK AND PRIOR TO COMMENCING WORK. 3. 30 5 FT 1.00 IN./HR. A 570Z-6P-PRX-COM 6" POP-UP TURF HEAD WITH 8Q/8T/8H/8F "O" NOZZLES .17, .22, .33, .66 30 8 FT 1.00 IN./HR. A TORO 570Z-6P-PRX-COM 6" POP-UP TURF HEAD WITH 10Q/10T/10H/10F "O" NOZZLES .23, .34, .51, 1.03 30 10 FT 1.00 IN./HR. A THE CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL EXISTING UTILITIES, STRUCTURES AND SERVICES BEFORE COMMENCING WORK. THE LOCATIONS OF UTILITIES, STRUCTURES AND SERVICES SHOWN IN THESE PLANS ARE APPROXIMATE ONLY. ANY DISCREPANCIES BETWEEN THESE PLANS AND ACTUAL FIELD CONDITIONS SHALL BE REPORTED TO THE OWNER'S REPRESENTATIVE. TORO 570Z-6P-PRX-COM 6" POP-UP TURF HEAD WITH 12Q/12T/12H/12F "O" NOZZLES .37, .49, .74, 1.48 30 12 FT 1.00 IN./HR. A TORO 570Z-6P-PRX-COM 6" POP-UP TURF HEAD WITH 15Q/15T/15H/15F "O" NOZZLES .58, .77, 1.16, 2.31 30 15 FT 1.00 IN./HR. A TORO 570Z-6P-PRX-COM 6" POP-UP TURF HEAD WITH LCS/RCS/4X30SST NOZZLES .33, .66 30 1.00 IN./HR. THE CONTRACTOR SHALL OBTAIN THE PERTINENT ENGINEERING OR ARCHITECTURAL PLANS BEFORE BEGINNING WORK. HUNTER PGP-04-CV 4" POP-UP TURF ROTOR WITH MPR-25 NOZZLES (RED) 1.00, 1.38, 1.98, 3.82 45 4X15 FT 4X30 FT 25 FT 0.70 IN./HR. A HUNTER PGP-04-CV 4" POP-UP TURF ROTOR WITH MPR-30 NOZZLES (GREEN 1.40, 1.85, 2.96, 5.78 45 30 FT 0.70 IN./HR. A HUNTER PGP-04-CV 4" POP-UP TURF ROTOR WITH MPR-35 NOZZLES (BEIGE) 1.92, 2.46, 3.81, 7.58 45 35 FT 0.70 IN./HR. A TORO 570Z-6P-PRX-COM 6" POP-UP BUBBLER HEAD WITH A 2B-90-PC2 STREAM BUBBLER NOZZLE, EACH SYMBOL REPRESENTS TWO (2) BUBBLERS PER TREE, PLACE BUBBLERS AT EDGE OF ROOT BALL ON OPPOSITE SIDES OF TREE, TYPICAL. ADJUST BUBBLER STREAMS TO WET THE ROOT BALL AND AMENDED SOIL WITHOUT HITTING THE TRUNK OF THE TREE. 30 1.5 FT N/A A A 4. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS REQUIRED TO PERFORM THE WORK INDICATED HEREIN BEFORE BEGINNING WORK. 5. THIS DESIGN IS DIAGRAMMATIC. ALL EQUIPMENT SHOWN IN PAVED AREAS IS FOR DESIGN CLARITY ONLY AND IS TO BE INSTALLED WITHIN PLANTING AREAS. 6. THE CONTRACTOR SHALL NOT WILLFULLY INSTALL ANY EQUIPMENT AS SHOWN ON THE PLANS WHEN IT IS OBVIOUS IN THE FIELD THAT UNKNOWN CONDITIONS EXIST THAT WERE NOT EVIDENT AT THE TIME THESE PLANS WERE PREPARED. ANY SUCH CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE PRIOR TO ANY WORK OR THE IRRIGATION CONTRACTOR SHALL ASSUME ALL RESPONSIBILITY FOR ANY FIELD CHANGES DEEMED NECESSARY BY THE OWNER. 7. INSTALL ALL EQUIPMENT AS SHOWN IN THE DETAILS AND SPECIFICATIONS. CONTRACTOR SHALL BE RESPONSIBLE TO COMPLY WITH LOCAL CITY, COUNTY AND STATE REQUIREMENTS FOR BOTH EQUIPMENT AND INSTALLATION. 8. ACTUAL LOCATION FOR THE INSTALLATION OF THE BACKFLOW PREVENTER AND THE AUTOMATIC CONTROLLER IS TO BE DETERMINED IN THE FIELD BY THE OWNER'S AUTHORIZED REPRESENTATIVE. H. CONTRACTOR SHALL BE RESPONSIBLE FOR THE PLACEMENT OF ALL SCH. 40 PVC SLEEVING UNDER PAVING, WALLS AND CURBS AT NO LESS THAN 24" BELOW GRADE AND NO LESS THAN 2X DIAMETER OF IRRIGATION PIPE IN AREAS WHERE PIPE CROSSING WILL OCCUR. WHEN PIPE SIZE IS NOT AVAILABLE USE 6" SLEEVING MATERIAL. CONFIRM CROSSINGS WITH OWNER'S REPRESENTATIVE PRIOR TO PAVING AND HARDSCAPE CONSTRUCTION. 10. ALL PIPE UNDER PAVED AREAS TO BE INSTALLED IN SLEEVING TWICE THE DIAMETER OF THE PIPE CARRIED. SEE LEGEND FOR TYPE. ALL WIRE UNDER PAVED AREAS TO BE INSTALLED IN A SCH. 40 SLEEVE THE SIZE REQUIRED TO EASILY PULL WIRE THROUGH. ALL SLEEVES TO BE INSTALLED WITH A MINIMUM DEPTH AS SHOWN ON THE SLEEVING DETAILS. SLEEVES TO EXTEND AT LEAST 12" PAST THE EDGE OF THE PAVING. EXISTING IRRIGATION IN THIS AREA SHALL BE PROTECTED IN PLACE FOR CONTINUED USE. CONTRACTOR SHALL VERIFY THE EXTENT OF THE EXISTING SYSTEM AND MAKE ADJUSTMENTS TO CAP OFF OR MODIFY THE EXITING SYSTEM TO MEET THE NEW LANDSCAPE CONDITION IF NECESSARY. 11. ALL QUICK COUPLER AND REMOTE CONTROL VALVES TO BE INSTALLED IN SHRUB OR GROUND COVER AREAS WHERE POSSIBLE. ALL QUICK COUPLER AND REMOTE CONTROL VALVES TO BE INSTALLED AS SHOWN ON THE INSTALLATION DETAILS. INSTALL ALL QUICK COUPLER AND REMOTE CONTROL VALVES WITHIN 18" OF HARDSCAPE. CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING EXISTING BACKFLOW DEVICE AND TESTING FOR PROPER OPERATION. SHOULD BACKFLOW DEVICE BE INOPERABLE OR NOT IN PLACE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIR OR REPLACEMENT OF SAID BACKFLOW DEVICE. CONFIRM ANY DISCREPANCIES WITH OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO BIDDING WORK AND PRIOR TO COMMENCING WORK. NO SYMBOL F RAIN BIRD RAIN BIRD CONNECTION BETWEEN XFS DRIP TUBING AND PVC SUPPLY AND DISCHARGE HEADERS SHALL BE MADE USING XF DRIP LINE BARBED FITTINGS, SCH. 40 PVC THREADED FITTINGS, SCH. 80 NIPPLES AND FLEXIBLE NIPPLES. WHEN THE CONNECTION IS AT THE END RUN OF THE TUBING USE A 1/2" SCH. 40 PVC 301 TARROW STREET, 7th FLOOR COLLEGE STATION, TX 77840 (979) 458-7000 http://www.tamus.edu/business/facilities-planningconstruction/ B XFS-06-12 SUBSURFACE DRIP TUBING (COPPER EXTERIOR COLOR) WITH 0.60 GPH, PRESSURE COMPENSATING EMITTERS INTERNALLY INSTALLED IN THE DRIP TUBING AT 12" O.C. SPACING. DRIP TUBING SHALL BE EQUIPPED WITH COPPER CHIP TECHNOLOGY TO PREVENT ROOT INTRUSION INTO THE DRIP EMITTER. DRIP TUBING SHALL BE INSTALLED 2" BELOW FINISHED SOIL GRADE (NOT COUNTING MULCH) AND IN PARALLEL ROWS A MAXIMUM OF 16" ON CENTER. THE PERIMETER ROW OF DRIP TUBING SHALL BE INSTALLED A MAXIMUM OF 4" FROM THE EDGE OF ANY HARDSCAPE OR TURF EDGE. ALL SUBSEQUENT INTERIOR ROWS SHALL BE ADJUSTED TO PROVIDE AN EVEN SPACING ACROSS THE PLANTER WITHOUT EXCEEDING 16" MAXIMUM SPACING. INSTALL 9" PVC COATED GALVANIZED TUBING STAKES A MAXIMUM OF FIVE (5) FEET ON CENTER ALONG THE LENGTH OF THE TUBING. TUBING STAKES SHALL BE MODEL #GDTS140900 AS MANUFACTURED BY GPH IRRIGATION PRODUCTS (866) 582-9684. THE HATCH PATTERN SYMBOLS ON THE PLANS REPRESENT THE APPROXIMATE DIRECTION AND SPACING OF THE DRIP TUBING ROWS, SEE ACTUAL SPACING REQUIREMENTS ABOVE AND IN DETAILS. C XF SERIES 17mm BARBED FITTINGS FOR ALL CONNECTIONS BETWEEN DRIP TUBING (TUBING-TO-TUBING ONLY). ALL BARBED DRIP TUBING FITTINGS SHALL BE INSTALLED USING A FITINS-TOOL FOR PROPER INSERTION OF THE FITTING INTO THE TUBING. NO HEATING OF TUBING SHALL BE ALLOWED. N/A AS APPROVED PVC SUPPLY AND DISCHARGE HEADERS SHALL BE PVC LATERAL LINE PIPE (AS SHOWN BELOW), 1 1/4" MINIMUM SIZE WITH SCH. 40 PVC FITTINGS. B,C,J NO SYMBOL LASCO 1/2" SCH. 40 PVC BALL VALVE WITH THREADED ENDS AND A LASCO MHT-102 3/4" MHT X 1/2" FIPT ADAPTER WITH A LASCO FHT-301 HOSE THREAD CAP FOR USE AS A DRIP TUBING FLUSH VALVE. SEE PLANS FOR LOCATIONS. INSTALL INSIDE A 10" ROUND VALVE BOX C,E NO SYMBOL RAIN BIRD ARV050 AIR/VACUUM RELIEF VALVE INSTALLED WITH A XFD-TFA-075 BARB X 3/4" FIPT TEE FITTING AND A 3/4" X 1/2" PVC REDUCER BUSHING, INSTALL AIR RELIEF ASSEMBLY AT THE HIGH POINT OF EACH PLANTER. INSTALL A MINIMUM OF ONE (1) ARV FOR EVERY 500 FEET OF DRIP TUBING IN ANY GIVEN DRIP ZONE. USING AN AIR RELIEF LATERAL, CONNECT AIR RELIEF VALVE TO ALL DRIPLINE LATERALS WITHIN THE ELEVATED AREA. MULTIPLE ARV'S SHALL BE REQUIRED PER RCV WITHIN UNDULATING AREAS, VERIFY QUANTITY PRIOR TO STARTING WORK. INSTALL INSIDE A 6" ROUND VALVE BOX C,F SUPERIOR 3300 SERIES 1-1/2" NORMALLY OPEN MASTER CONTROL VALVE P WEATHERMATIC SLFSI-T15 SERIES TEE TYPE FLOW SENSOR IN A 1-1/2" SCH. 40 TEE, WIRE TO SMARTLINK AIRCARD USING PE-39 COMMUNICATIONS CABLE PER MANUFACTURER'S RECOMMENDATIONS Q NO SYMBOL 13. CONTRACTOR SHALL INSTALL ADDITIONAL CHECK VALVES TO HEADS AND LATERALS AS REQUIRED TO PREVENT LOW HEAD DRAINAGE. RAIN BIRD KSQ ARCHITECTS, PC STUDY COLLABORATE DESIGN COLORADO OKLAHOMA NEW YORK NORTH CAROLINA TEXAS 1452 HUGHES RD., SUITE 150 GRAPEVINE, TX 76051 (972) 259-8500 http://www.ksqarchitects.com CONSULTANTS CIVIL JQ ENGINEERING 2105 COMMERCE STREET DALLAS, TX 75201 (214) 752-9098 http://www.jqeng.com LANDSCAPE ARCHITECT COLEMAN AND ASSOCIATES 9890 SILVER MOUNTAIN DRIVE AUSTIN, TX 78739 (512) 476-2090 http://www.colemanandassoc.com STRUCTURAL ENGINEER JQ ENGINEERING 1301 WEST 7TH STREET, SUITE 141 FT. WORTH, TX 76102 (817) 546-7200 http://www.jqeng.com JOHN DEERE/ *SINGLE SOURCE RAIN-WATER AND CONDENSATE REUSE SYSTEM, COMPLETE WITH 20,000 GALLON TANK, FLOATS, SUBMERSIBLE PUMP (45 GPM WATERTRONICS/ FLOW AT 65 PSI PRESSURE), DISCHARGE FILTER, ALARMS AND PUMP CONTROLS. PUMP START SHALL BE CONNECTED TO IRRIGATION CONTROLLER. OR AS APPROVED N/A YARDNEY SB-2, 2" FLANGED STEEL BASKET STRAINER WITH 80 MESH STAINLESS STEEL FILTER ELEMENT. INSTALL ON DOWNSTREAM SIDE OF RECYCLED WATER POINT OF CONNECTION. INSTALL INSIDE A JUMBO RECTANGULAR VALVE BOX. O LASCO SLO-CLOSE SCH. 80 PVC TRUE-UNION BALL VALVE WITH SOLVENT WELD CONNECTIONS, LINE SIZE R,X RAIN BIRD 3RC QUICK COUPLER VALVE WITH BRASS BALL VALVE INSTALLED UPSTREAM OF QUICK COUPLER WITHIN SAME VALVE BOX G,X RAIN BIRD PEB-PRS-D (1", 1-1/2", 2") SERIES PRESSURE REGULATED, PLASTIC REMOTE CONTROL VALVE, SIZE AS SHOWN H,X RAIN BIRD XCZ-100-PRB-COM (1") DRIP REMOTE CONTROL VALVE KIT, FOR DEMANDS LESS THAN 18 GPM XCZ-150-PRB-COM (1.5") DRIP REMOTE CONTROL VALVE KIT, FOR DEMANDS GREATER THAN 18 GPM SIZE DRIP CONTROL VALVE BOX TO ACCOMMODATE ALL DRIP VALVE EQUIPMENT AND ISOLATION VALVE I,X WEATHERMATIC SMARTLINE SERIES IRRIGATION CONTROLLER, MODEL # SL1600 WITH SLM16DM 16-ZONE DECODER MODULE FOR 2-WIRE CONVERSION. INSTALL WITHIN SLPED-ENC STAINLESS STEEL PEDESTAL ENCLOSURE. PROVIDE SLAIR-GSM/FLOW TO CONNECT CONTROLLER TO SITE SMARTLINK NETWORK S NO SYMBOL PAIGE ELECTRIC THE CONTROLLER SHALL BE GROUNDED USING A #182000 5/8" X 8 FOOT COPPER CLAD GROUND ROD, A #182005 CAST BRONZE ROD CLAMP AND THE REQUIRED LENGTH OF #6AWG BARE, SINGLE STRAND COPPER GROUND WIRE. INSTALL INSIDE A 10" ROUND VALVE BOX. T NO SYMBOL WEATHERMATIC EACH MASTER VALVE, REMOTE CONTROL VALVE AND DRIP REMOTE CONTROL VALVE INSTALLED AS PART OF PROPOSED CONTROLLER "A" SHALL BE INSTALLED WITH A SLDEC1 SINGLE STATION 2-WIRE DECODER. MULTIPLE STATION DECODERS MAY BE USED ON GROUPS OF REMOTE AND DRIP REMOTE CONTROL VALVE AT THE DISCRETION OF THE CONTRACTOR. VALVES SHARING MULTIPLE STATION DECODERS SHALL NOT BE MORE THAN 25 FEET APART. SLGDT LINE SURGE PROTECTION DEVICES SHALL BE INSTALLED ALONG THE 2-WIRE PATH AT AN ON CENTER SPACING NOT TO EXCEED 500 FEET. INSTALL THE SLGDT DEVICE AND GROUND ROD IN A STANDARD RECTANGULAR VALVE BOX. INSTALL ONE SLGDT DEVICE WITHIN 10 FEET OF THE IRRIGATION CONTROLLER ASSEMBLY. T,U,V,W WEATHERMATIC SLW5 WEATHER STATION, WEATHER STATION SHALL BE INSTALLED A MINIMUM OF 10' ABOVE GRADE IN AN UNOBSTRUCTED LOCATION WITHIN 1000 FOOT LINE OF SIGHT OF CONTROLLER, WIRE TO CONTROLLER PER MANUFACTURER'S RECOMMENDATION N/A N/A 120 VOLT ELECTRICAL POWER, PROVIDED BY ELECTRICIAN, VERIFY ACTUAL LOCATION IN FIELD N/A AS APPROVED PVC PIPE 3/4" - 2" CL. 200 SOLVENT WELD WITH BELL ENDS AS LATERAL LINES 18" BELOW GRADE J EDWARD J. KOCHANEK AS APPROVED PVC PIPE 2-1/2 SCH. 40 SOLVENT WELD WITH BELL ENDS AS MAINLINES 24" BELOW GRADE J,K LI 14. THE CONTRACTOR SHALL USE PROPER GROUNDING TECHNIQUES FOR GROUNDING THE CONTROLLER AND RELATED EQUIPMENT PER MANUFACTURERS SPECIFICATIONS. SWEENEY AND ASSOCIATES RECOMMENDS MEASURING FOR PROPER GROUND AT LEAST ONCE ANNUALLY, AND NECESSARY ADJUSTMENTS MADE TO COMPLY WITH MANUFACTURER SPECIFICATIONS. .21 (.42 TOTAL) TEXAS A&M UNIVERSITY SYSTEM OFFICE OF FACILITIES, PLANNING, AND CONSTRUCTION BARB X 1/2" MIPT ADAPTER FITTING. WHEN THE CONNECTION IS IN THE MIDDLE OF THE TUBING RUN USE A 1/2" SCH. 40 PVC THREADED TEE FITTING, A 1/2" X LENGTH AS REQUIRED SCH. 80 PVC THREADED NIPPLE, A 1/2" X 6" MIPT X FIPT FLEXIBLE NIPPLE, AND TWO (2) XFF-MA-050 17mm BARB X 1/2" MIPT ADAPTERS. ALL END RUNS OF TUBING SHALL BE CONNECTED WITH A PVC DISCHARGE HEADER. FLEXIBLE NIPPLES SHALL BE MODEL #GFN050600 AS MANUFACTURED BY GPH IRRIGATION PRODUCTS (866) 582-9684. CONTRACTOR IS TO PROVIDE AN ADDITIONAL PILOT WIRE FROM CONTROLLER ALONG ENTIRETY OF MAIN LINE TO THE LAST RCV ON EACH AND EVERY LEG OF MAIN LINE. LABEL SPARE WIRES AT BOTH ENDS. 12. ALL HEADS ARE TO BE INSTALLED WITH THE NOZZLE, SCREEN AND ARCS SHOWN ON THE PLANS. ALL HEADS ARE TO BE ADJUSTED TO PREVENT OVERSPRAY ONTO BUILDINGS, WALLS, FENCES AND HARDSCAPE. THIS INCLUDES, BUT NOT LIMITED TO, ADJUSTMENT OF DIFFUSER PIN OR ADJUSTMENT SCREW, REPLACEMENT OF PRESSURE COMPENSATING SCREENS, REPLACEMENT OF NOZZLES WITH MORE APPROPRIATE RADIUS UNITS AND THE REPLACEMENT OF NOZZLES WITH ADJUSTABLE ARC UNITS. GPM WATER MEP ENGINEER PURDY-MCGUIRE 17300 DALLAS PARKWAY, SUITE 3000 DALLAS, TX 75248 (972) 239-5357 http://www.purdy-mcguire.com IT/AV 4b TECHNOLOGY 12600 NORTHBOROUGH DRIVE, SUITE 290 HOUSTON, TX 77067 (832) 249-9379 http://4btechnology.com/ FOODSERVICE DESIGN BAKERGROUP 2220 EAST PARIS AVENUE SE. GRAND RAPIDS, MI 49546 (800) 968-4011 http://bakergroup.com LASCO ALL FITTINGS USED WITH SOLVENT WELD LATERAL LINE AND MAINLINE PIPE SHALL BE SCH. 80 PVC, WHITE IN COLOR, AND SIZED TO MATCH THE LATERAL LINE OR MAINLINE PIPE PIPE. ALL THREADED PVC NIPPLES SHALL BE SCH. 40 PVC PIPE WITH MOLDED THREADS. NO SYMBOL CHRISTY'S ALL SOLVENT WELD CONNECTIONS FOR BOTH MAINLINE AND LATERAL LINE SHALL BE MADE USING THE TWO-STEP PROCESS OF PRIMER AND SOLVENT CEMENT. PRIMER SHALL BE LOW VOC "PURPLE PRIMER". MAINLINE SOLVENT CEMENT SHALL BE LOW VOC, "GRAY-HEAVY BODY" CEMENT. LATERAL LINE SOLVENT CEMENT SHALL BE LOW VOC, "RED HOT BLUE GLUE" CEMENT. USE DAUBERS SIZED AT LEAST ONE HALF THE SIZE OF THE LARGEST SIZE PIPE BEING JOINED. N/A PVC PIPE AS SLEEVING, SIZES AS SHOWN ON SLEEVING PLAN (MINIMUM SIZE IS 4"). PLACE BELOW ALL PAVING, HARDSCAPE ETC., AND AS DIRECTED BY OWNER'S AUTHORIZED REPRESENTATIVE. SLEEVES SHALL EXTEND 24" BEYOND EDGE OF PAVED SURFACE. CONTRACTOR SHALL MARK SLEEVE LOCATION WITH 3/8" x 3" BRASS OR STAINLESS STEEL STOVE BOLT PER TAMU FACILITY DESIGN GUIDELINES. SLEEVING BENEATH PEDESTRIAN PAVEMENT SHALL BE CL. 200 PVC SOLVENT WELD SLEEVING BENEATH DRIVES AND STREETS SHALL BE SCH. 40 PVC SOLVENT WELD J,L,M AS APPROVED SECTION VIEW - N.T.S. V MULTIPLE STATION DECODER PLAN VIEW - N.T.S. W STATION DECODER AND GROUNDING G.P.M. APPROXIMATE AREA SERVED BY DRIP TUBING (IN DRIP ZONES ONLY) VALVE SIZE N SE D I RR IG A 21 JULY 2016 TEXAS A&M UNIVERSITY WEST CAMPUS SUPPORT BUILDING #02-3177 COLLEGE STATION, TEXAS 77843 NO SYMBOL WEATHERMATIC SLWIRE (2 - #14 CONDUCTORS) TWO-WIRE PATH TO BE INSTALLED BETWEEN THE CONTROLLER AND THE MASTER VALVE AND REMOTE CONTROL VALVES. TWO-WIRE PATH SHALL FOLLOW THE MAINLINE AND BE IN A 1 1/4" CONDUIT. J,L,N NO SYMBOL 3M DBR/Y-6 DIRECT BURIAL WATER-PROOF WIRE CONNECTORS FOR USE ON ALL WIRE CONNECTIONS (U.L. APPROVED) N NO SYMBOL K.B.I. KSC-XXX-S SWING CHECK VALVE, LINE SIZE, 1 DOWNSTREAM OF EACH RCV WHEN RCV IS LOWER THAN THE SPRINKLERS INSTALL WITHIN SPRINKER/DRIP ZONES AS REQUIRED TO PREVENT LOW HEAD/EMITTER DRAINAGE. N/A NO SYMBOL K.B.I. KC-XXX-S SPRING CHECK VALVE, LINE SIZE, 1 DOWNSTREAM OF EACH RCV IMMEDIATELY ABOVE FIRST LATERAL LINE TEE WHEN RCV IS HIGHER THAN THE SPRINKLERS, INSTALL WITHIN SPRINKER/DRIP ZONES AS REQUIRED TO PREVENT LOW HEAD/EMITTER DRAINAGE. N/A NO SYMBOL CARSON VALVE BOXES, SIZE PER EQUIPMENT LEGEND, WITH T-COVER LIDS AND CAPTIVE BOLT AND LOC-KIT. FOR ROUND FLUSH VALES AND AIR RELIEF VALVES USE MODEL 708, 10" ROUND SHALL BE MODEL 910, 12" STANDARD RECTANGULAR. SHALL BE MODEL 1419, 12" JUMBO RECT. SHALL BE MODEL 1220, SUPER JUMBO SHALL BE MODEL 1324, AND SUPER JUMBO XL SHALL BE MODEL 1730. VALVE BOXES SHALL HAVE GREEN HDPE BODY AND GREEN LIDS IN TURF, GREEN LIDS IN SHRUB BEDS, AND TAN LIDS IN ROCK MULCH. FOR USE IN NON-VEHICULAR TRAFFIC SITUATIONS ONLY. DO NOT INSTALL IN CONCRETE OR ASPHALT. N/A VALVE NUMBER C NO SYMBOL N/A E OF TE XA TE TA S S K. TORO .07, .13 9. CONTRACTOR SHALL EXERCISE EXTREME CAUTION WHEN WORKING WITHIN THE DRIPLINE OF EXISTING TREES. NO MECHANICAL TRENCHING WITHIN THE DRIPLINE OF THE EXISTING TREE WILL BE ALLOWED. CONTRACTOR SHALL REFER TO ARBORIST REPORT FOR ADDITIONAL PRECAUTIONS REQUIRED FOR THE EXISTING TREES. VERIFY ALL LAYOUT IN FIELD WITH OWNER'S AUTHORIZED REPRESENTATIVE. 570Z-6P-PRX-COM 6" POP-UP TURF HEAD WITH 5Q/FH "O" NOZZLES DETAIL CONTRACTOR SHALL FIELD VERIFY DEPTH AND LOCATION OF ALL EXISTING UTILITIES PRIOR TO BIDDING WORK AND AGAIN PRIOR TO COMMENCING WORK. VERIFICATION SHALL BE DOCUMENTED AND DELIVERED TO OWNER'S REPRESENTATIVE. J. TORO PREC. RATE G. I. MODEL NO. / DESCRIPTION RADIUS H ALL LOCAL MUNICIPAL AND STATE LAWS, RULES AND REGULATIONS GOVERNING OR RELATING TO ANY PORTION OF THIS WORK ARE HEREBY INCORPORATED INTO AND MADE A PART OF THESE SPECIFICATIONS AND THEIR PROVISIONS SHALL BE CARRIED OUT BY THE CONTRACTOR. 2. MANUFACT. PSI Q TO R EXISTING IRRIGATION NOTES A. SYMBOL IRRIGATION NOTES KEY PLAN REVISIONS ISSUE: ISSUE FOR BID ISSUE DATE: JULY 21, 2016 SHEET NAME: PLAN VIEW - N.T.S. X VALVE BOX PLACEMENT IRRIGATION LEGEND AND NOTES SHEET NUMBER: L3.10 FINISHED GRADE IN TURF AREAS TEXAS A&M UNIVERSITY SYSTEM OFFICE OF FACILITIES, PLANNING, AND CONSTRUCTION 301 TARROW STREET, 7th FLOOR COLLEGE STATION, TX 77840 (979) 458-7000 http://www.tamus.edu/business/facilities-planningconstruction/ KSQ ARCHITECTS, PC STUDY COLLABORATE DESIGN COLORADO OKLAHOMA NEW YORK NORTH CAROLINA TEXAS 1452 HUGHES RD., SUITE 150 GRAPEVINE, TX 76051 (972) 259-8500 http://www.ksqarchitects.com CONSULTANTS CIVIL SECTION VIEW - N.T.S. A POP-UP SPRINKLER JQ ENGINEERING 2105 COMMERCE STREET DALLAS, TX 75201 (214) 752-9098 http://www.jqeng.com SECTION VIEW - N.T.S. B DRIPLINE CONNECTION TO PVC LATERAL C DRIPLINE LAYOUT LANDSCAPE ARCHITECT COLEMAN AND ASSOCIATES 9890 SILVER MOUNTAIN DRIVE AUSTIN, TX 78739 (512) 476-2090 http://www.colemanandassoc.com STRUCTURAL ENGINEER JQ ENGINEERING 1301 WEST 7TH STREET, SUITE 141 FT. WORTH, TX 76102 (817) 546-7200 http://www.jqeng.com MEP ENGINEER PURDY-MCGUIRE 17300 DALLAS PARKWAY, SUITE 3000 DALLAS, TX 75248 (972) 239-5357 http://www.purdy-mcguire.com IT/AV 4b TECHNOLOGY 12600 NORTHBOROUGH DRIVE, SUITE 290 HOUSTON, TX 77067 (832) 249-9379 http://4btechnology.com/ 1" 2" MIN. FOODSERVICE DESIGN OF TE XA TE TA S S BAKERGROUP 2220 EAST PARIS AVENUE SE. GRAND RAPIDS, MI 49546 (800) 968-4011 http://bakergroup.com LI C E N TO R EDWARD J. KOCHANEK SE D I RR IG A 21 JULY 2016 SECTION VIEW - N.T.S. D DRIPLINE LAYOUT SECTION VIEW - N.T.S. E DRIP FLUSH VALVE SECTION VIEW - N.T.S. F DRIP AIR RELIEF VALVE SECTION VIEW - N.T.S. G QUICK COUPLER VALVE TEXAS A&M UNIVERSITY WEST CAMPUS SUPPORT BUILDING #02-3177 COLLEGE STATION, TEXAS 77843 KEY PLAN A REVISIONS FLOW C FLOW C C C C ISSUE: ISSUE FOR BID ISSUE DATE: JULY 21, 2016 SHEET NAME: IRRIGATION DETAILS SECTION VIEW - N.T.S. SECTION VIEW - N.T.S. SECTION VIEW - N.T.S. SHEET NUMBER: H REMOTE CONTROL VALVE I DRIP RCV ASSEMBLY J PIPE UNDER SOFTSCAPE L3.11 LOW VOLTAGE WIRES, 3 MAXIMUM WIRES PASS THROUGH GROOVES IN TUBE LID TO ALLOW LID TO CLOSE CLOSE TUBE LID AFTER WIRE IS INSERTED INTO TUBE NOTE: SLEEVES TO EXTEND AT LEAST 24" PAST THE EDGE OF THE PAVING. POLY TUBE PRE-FILLED WITH WATERPROOF GEL C LOCK TABS PREVENT WIRE REMOVAL ONCE CONNECTOR IS INSERTED B A D DIMENSION 1/2" TO 6" IN SIZE D SCOTCHLOK ELECTRICAL SPRING CONNECTOR. WIRES SHALL BE PRE-STRIPPED OF 1/2" OF THE INSULATION PRIOR TO INSERTION INTO THE CONNECTIOR. TWIST CONNECTOR ONTO WIRES TO SEAT FIRMLY. D TEXAS A&M UNIVERSITY SYSTEM OFFICE OF FACILITIES, PLANNING, AND CONSTRUCTION 301 TARROW STREET, 7th FLOOR COLLEGE STATION, TX 77840 (979) 458-7000 http://www.tamus.edu/business/facilities-planningconstruction/ SCOTCHLOK CONNECTOR AND WIRES INSERTED INTO TUBE UNTIL THE CONNECTOR PASSES LOCK TABS D A B C D NOTE: WIRE CONNECTOR SHALL BE A 3M DBR/Y-6 DIRECT BURY SPLICE KIT (U.L. APPROVED). 36" 24" 24" 4" KIT SHALL INCLUDE A SCOTCHLOK Y SPRING CONNECTOR, A POLYPROPYLENE TUBE AND A WATERPROOF SEALING GEL. TUBE SHALL BE SUPPLIED PREFILLED WITH GEL. DIRECT BURY SPLICE KIT SHALL BE USED TO ELECTRICALLY CONNECT 2 - 3 #14 OR 2 #12 PRE-STRIPPED COPPER WIRES. LARGER WIRES OR GREATER QUANTITIES OF WIRES SHALL REQUIRE A LARGER APPROVED WIRE CONNECTION. KSQ ARCHITECTS, PC STUDY COLLABORATE DESIGN COLORADO OKLAHOMA NEW YORK NORTH CAROLINA TEXAS 1452 HUGHES RD., SUITE 150 GRAPEVINE, TX 76051 (972) 259-8500 http://www.ksqarchitects.com CONSULTANTS CIVIL PLAN VIEW - N.T.S. K MAINLINE THRUST BLOCKS SECTION VIEW - N.T.S. L PIPE UNDER HARDSCAPE SECTION VIEW - N.T.S. M SLEEVE IDENTIFIER N WIRE CONNECTORS JQ ENGINEERING 2105 COMMERCE STREET DALLAS, TX 75201 (214) 752-9098 http://www.jqeng.com LANDSCAPE ARCHITECT COLEMAN AND ASSOCIATES 9890 SILVER MOUNTAIN DRIVE AUSTIN, TX 78739 (512) 476-2090 http://www.colemanandassoc.com STRUCTURAL ENGINEER JQ ENGINEERING 1301 WEST 7TH STREET, SUITE 141 FT. WORTH, TX 76102 (817) 546-7200 http://www.jqeng.com MEP ENGINEER PURDY-MCGUIRE 17300 DALLAS PARKWAY, SUITE 3000 DALLAS, TX 75248 (972) 239-5357 http://www.purdy-mcguire.com IT/AV 4b TECHNOLOGY 12600 NORTHBOROUGH DRIVE, SUITE 290 HOUSTON, TX 77067 (832) 249-9379 http://4btechnology.com/ FOODSERVICE DESIGN OF TE XA TE TA S S BAKERGROUP 2220 EAST PARIS AVENUE SE. GRAND RAPIDS, MI 49546 (800) 968-4011 http://bakergroup.com LI C E N TO R EDWARD J. KOCHANEK SE D I RR IG A 21 JULY 2016 SECTION VIEW - N.T.S. O BASKET STRAINER SECTION VIEW - N.T.S. P MASTER CONTROL VALVE SECTION VIEW - N.T.S. Q FLOW SENSOR SECTION VIEW - N.T.S. R BALL VALVE TEXAS A&M UNIVERSITY WEST CAMPUS SUPPORT BUILDING #02-3177 COLLEGE STATION, TEXAS 77843 KEY PLAN REVISIONS ISSUE: ISSUE FOR BID ISSUE DATE: JULY 21, 2016 SHEET NAME: IRRIGATION DETAILS SECTION VIEW - N.T.S. SECTION VIEW - N.T.S. SECTION VIEW - N.T.S. SHEET NUMBER: S CONTROLLER ASSEMBLY T GROUND ROD INSTALLATION U SINGLE STATION DECODER L3.12