User Manual-英文-2

Transcription

User Manual-英文-2
User Manual
REEKBOX.com
Thank you for choosing Shenzhen Sundeu Technology
Please read the user manual carefully before using the product for any purpose
Product introduction
The REEBOX V1.2 is a electronic intelligent control main board designed for E-cigarette.
Compared with other products in market, REEBOX V1.20 has features including protection
of reverse battery connection, AC Auto-balance temperature control mode, Micro-USB connection for system upgrade, OLED screen and its the unique design, the burning-resistant
protection as well as other numerous functions with advance technology. REEBOX V1.2 is a
product that is leading today’s market of E-cigarette electronic intelligent control main board.
Characteristic
•AC Auto-balance temperature control mode
•Burning-resistant protection
•Reverse battery connection protection
•Micro-USB connection for system upgrade on desktop
Size
Length: 72.7mm±0.15
Height: 11.1mm±0.1
Width: 18.1mm±0.15
Thickness: 1.6mm±0.1
Function
Normal Voltage
3.7V Li-battery, Max voltage 9.5V, Min voltage 0.3V, display in 5-80W,
reverse connected battery protection and reverse connected power charging protection
Resistance Loading
1
1. BYPASS mode: 0.2-3Ω
2. Power mode: 0.09-3Ω
3. Temperature control mode: 0.03-1Ω
Standard Resistance Setting in TC mode
Tank Ohm real time checking should be under the power mode, this function does not work
under temperature control mode. Please press “+” and “-” button at same time for 1S to
check the resistance of the atomizer Aromatically. So when press power button at 0Ω, LED
will show“NO.T.BASE”and remind user to reset basic ohm.
Power Setting
Power setting mode works under 5-80W, output voltage value should be calculated based on
loading resistance via controller. The controller will stay output 9.5V accordingly if output is
over 9.5V, but the real output power will be less than setting power under this circumstance.
Setting Temperature
Temperature setting is adjustable with setting temperature between 200-600℉(100-315℃).
Auto-Power Reduction
If battery voltage is lowers than 3.3V under smoking mode, output voltage will reduce to 5W
as minimum automatically.
Operation and Display
The original setting is standby status. It enters into standby status when LOGO appears on
the screen for 3 seconds.
2
Power on
Press the power button 5 times, LOGO appears in 3 seconds and then enter to user interface,
and sleep mode will activate without any operation for 30 seconds, it has memory after switch
it on again. Smoke mode will be activated after pressing power button to smoke under standby
or sleep mode.
Display
1.Adjustable POWER mode: display with battery capacity, resistance, output voltage and
output power
2.BYPASS mode: display with battery capacity, resistance, output voltage and BYPASS LOGO
3.Temerature control mode: display with battery capacity, resistance, coil material,
temperature and AC/NC
Function Option
Press power button 5 times to enter MODE SELECTION interface and will display 5 modes,
which are power mode, Celsius temperature control mode, F temperature control mode,
BYPASS Mode, and power off, press +/- button to switch, Long press power button to
confirm.
1. Power mode: press “-” button to decrease and “+” to increase, decrease and increase
slightly with 0.1W by pressing “+/-”, and 1W by long press the button. The setting data will be
unchangeable at its max or min value with setting range of 5-80W.
2. Celsius temperature control mode: tank coil is made of NI/TI/316 3 materials and is
available with AC/NC modes for options. Press power button to confirm AC Auto-balance
temperature control mode, warming up from 0℃, adjust and balance for atomization automatically in accordance with the coil material, and the liquid features. Under NC normal
temperature control mode press”-” to decrease, and press“+”to increase, 1℃ up or down by
pressing the button, and 10℃ up or down by long pressing the button. The setting data will
be unchangeable at its max or min value, Fahrenheit temperature setting in 200-600℉.
3
3. Fahrenheit temperature control mode: tank coil is made of NI/TI/316 3 materials and is
available with AC/NC modes for options. Press power button to confirm AC Auto-balance
temperature control mode, warming up from 0℃, adjust and balance for atomization automatically in accordance with the tank material, and the liquid features.
Under NC normal temperature control press”-” to decrease, “+”to increase, 1℃ up or down
by pressing the button, and 10℃ up or down by long pressing the button. The setting data
will be unchangeable at its max or min value, temperature setting in 100-315℃.
4. BYPASS Mode: this mode supports 0.2Ωminimum and output with the max value of the
battery at maximum.
5. Power off: enter MODE SELECTION interface, choose “SYS OFF”, and hold POWER
BUTTON to confirm, LED displays “BYEBYE!” to enter power off; press power button 5 times
to switch on.
Output adjustment
Under power on mode press “-” to decrease, “+” to increase, increase or decrease with 0.1W
by pressing “+/-”, increase or decrease with 1W by long pressing “+/-”. The setting data will
be unchangeable at its max or min value. The setting range is 5-8W in power on mode.
Under NC temperature control mode, press the button to increase or decrease with 1℃/℉,
10℃/℉ by long pressing the buttons. Fahrenheit setting range is 200-600℉, and Celsius
setting range is 100-315℃. The setting data will be unchangeable at its max or min value.
4
Lock Mode
Press the power button 3 times in 1.5 seconds to enter screen lock, LED will show a graph
of LOCK. You can not press +/- or smoking under SCREEN LOCK. Repress power button 3
times again to unlock, and LED will show a graph of UNLOCK.
Protection
Low voltage protection
If battery voltage is less than 3.3V-0.1V and power decrease to 20W, battery display will
flash and press power button will show “LOW BATTERY” to remind user for recharging of the
battery.
Vaping Timeout
When the smoking lasts more than 12 seconds, it will stop output and tank will also stop
working. LED will show “OVER TIME 12S”, and release power button to reuse.
Overheat Protection
Overheat protection will stop output when the PCB board temperature reaching over 75
degree during smoking. LED will show “Too Hot”, and it will return to user interface until the
PCB board cooling down.
Short Circuit Protection
The output will be closed if the tank short-circuited during smoking. LED will show“Short
Circuit”, and release power button back to the user interface.
Low-Resistance Protection
If tank output exceeds over 40A during smoking, LED will show “LOW RES”, and release
power button back to the user interface. There will be no response when press power button
at that time until user interface back again. If tank Ohm is less than the required Ohm, LED
will show “LOW RES”. There will be no response when press power button at that time,
please release power button back to user interface.
5
Check Atomizer
The output will be closed if the tank is empty during the smoke. LED screen shows “Check
Atomizer”, then release power button back to user interface.
Anti-dry Burning Protection
The tank should keeping output without any liquid, and it will be closed when hits the max
designed temperature. LED will shows “Dry Coil No Liquid”, release the power button back to
the user interface.
Updating
System Updating
1. Install the driver on a PC for the first time upgrade
2. Open upgrade interface from PC
3. Plug the micro USB cable and connect to the PC, and LED will show“Charge”“Update”,
choose “Update”,press power button to confirm
4. Choose the file to upgrade, and press “UPDATE” to upgrade in full
5. Do not plug out USB cable during upgrading, and repeat step of 2-4 if any mistake
occurred during upgrade
Logo Updating
1. Install the driver on a PC for the first time upgrade
2. Open upgrade interface from PC
3. Plug USB cable to PC end, and LED will show“Charge”“Update”, choose “Update”,press
the key to confirm
4. Open up a PC upgrade interface“OPEN LOGO”, choose the file to upgrade, press
“UPDATE LOGO”to upgrade in full
5. Do not plug out USB cable during upgrading, and repeat step of 2-4 if any mistake
occurred during upgrade
6
Charge
Micro-USB port is used for “Charge” or ”Update”, choose “Charge” and press power button
to confirm or system will start after 10 seconds automatically in default setting. OLED will
show “charging” during power charging every 0.5 second and can be fully charged until voltage reaching 4.2V. Then battery will stop show charging and the screen will switch off.
Warning
1. Please make sure atomizer must be the in cooling conditions (room temperature) before
testing the benchmark of resistance wire each time under temperature control mode
(AC/NC).
2. Please do not disconnect the power during upgrade process. If the power outage
accidentally occurred, please do it again.