Data sheet

Transcription

Data sheet
dataholz.com
Designation: awmxsom01
Version:
13.05.2008
Source:
TU-Graz/Labor für Bauphysik
Institut für Hoch- und Industriebau
Preparation: TUG, HE
External wall - Wall base connection with wood cladding
Fastening of the façade in
accordance with structural
design requirements
Vertical section
Joint sealed with suitable adhesive
tape
to prevent
convection
Stoßfugen
mit geeignetem
Fassadenbefestigung
lt. Statik
130
50 20 50
75
200
30-50
Bird
screen
Vogelschutzgitter
>300
10
Klebeband konvektionsdicht verkleben
1010 FloorBodenbelag
covering (parquet)
Parkett
5050 Cementitious
floor screed
Zementestrich
Separation
layer
Trennlage lt. ÖN B 2232
2020 Impact
sound absorbing subflooring
(sā€™<30MN/m)
Trittschalldämmung
MW-T (s'< MW-T
30 MN/m³)
5050 Acoustic
loose fill
layer
Schüttung
gebunden
Dampproofing
Feuchtigkeitsabdichtung
200
concrete ceiling
200 Reinforced
Stahlbetondecke
7575 Thermal
insulation (R>2,1
mK/W)
Wärmedämmung
(R>2,1
m²K/W)
20
10
>20
10
50
20
50
220
30
220
30
Cladding
Fassadenplatte
Battens
80/20
Fassadenplatte
Perimeter
insulation including drainage
Lattung
Dampproofing
Perimeterdämmung mit Drainage
Reinforced concrete
Feuchtigkeitsabdichtung
Insulation
Stahlbeton
Halsdämmung (h~500)
Building component used
awmohi 01a,
Floor above basement in accordance with figure,
Basement wall in accordance with figure
Additional building materials
Adhesive tape,
Bird screen
Wartungs-/Austauschintervall interval for the wall
Maintenance/replacement
für die
Sockelverkleidung
base
lining
5 - 10 years
5 - 10 Jahre
dataholz.com ā€“ Catalogue of timber building materials, components and component connections reviewed to consider
thermal, acoustic, fire performance requirements and ecological drivers for timber construction released by accredited testing
institutes.
These datasheets will generally be accepted as proofs of compliance by building authorities in Austria.
1/3
dataholz.com
Designation: awmxsom01
Version:
13.05.2008
Source:
TU-Graz/Labor für Bauphysik
Institut für Hoch- und Industriebau
Preparation: TUG, HE
External wall - Wall base connection with wood cladding
Joining technique, erection sequence (1 ... n)
2
5
6
4
3
1
dataholz.com ā€“ Catalogue of timber building materials, components and component connections reviewed to consider
thermal, acoustic, fire performance requirements and ecological drivers for timber construction released by accredited testing
institutes.
These datasheets will generally be accepted as proofs of compliance by building authorities in Austria.
2/3
dataholz.com
Designation: attachment wall base parapet connection
Version:
13.05.2008
Source:
TU-Graz/Labor für Bauphysik
Institut für Hoch- und Industriebau
Preparation: TUG, HE
Attachment wall base connection solid walls
Vertical section
Horizontal section
WICHTIG:
Fastening of the façade in
accordance with structural
design requirements
Important!
VERANKERUNGEN NACH DEM
Anchoring
has
to be put
in place after
VERKLEBEN DER
STOSSFUGEN
SETZEN!!!!
bonding of the joint!
nach statischen Erfordernissen
JointStoßfugen
sealed with
suitable adhesive tape to
mit geeignetem
Klebeband
konvektionsdicht verkleben
prevent
convection
75
200
Bird
screen
Vogelschutzgitter
>300
Fassadenbefestigung
lt. Statik
Number and size of anchors in accordance
Größestructural
und Anzahldesign
der Verankerungen
with
requirements
50
50
Precast concrete component
Perimeter insulation including drainage
Dampproofing
220 Reinforced concrete
30 Insulation
Building component used
awmoho 01a
Axiometric view
Additional building materials
Adhesive tape
dataholz.com ā€“ Catalogue of timber building materials, components and component connections reviewed to consider
thermal, acoustic, fire performance requirements and ecological drivers for timber construction released by accredited testing
institutes.
These datasheets will generally be accepted as proofs of compliance by building authorities in Austria.
3/3