Data sheet
Transcription
Data sheet
dataholz.com Designation: awmxsom01 Version: 13.05.2008 Source: TU-Graz/Labor für Bauphysik Institut für Hoch- und Industriebau Preparation: TUG, HE External wall - Wall base connection with wood cladding Fastening of the façade in accordance with structural design requirements Vertical section Joint sealed with suitable adhesive tape to prevent convection Stoßfugen mit geeignetem Fassadenbefestigung lt. Statik 130 50 20 50 75 200 30-50 Bird screen Vogelschutzgitter >300 10 Klebeband konvektionsdicht verkleben 1010 FloorBodenbelag covering (parquet) Parkett 5050 Cementitious floor screed Zementestrich Separation layer Trennlage lt. ÖN B 2232 2020 Impact sound absorbing subflooring (sā<30MN/m) Trittschalldämmung MW-T (s'< MW-T 30 MN/m³) 5050 Acoustic loose fill layer Schüttung gebunden Dampproofing Feuchtigkeitsabdichtung 200 concrete ceiling 200 Reinforced Stahlbetondecke 7575 Thermal insulation (R>2,1 mK/W) Wärmedämmung (R>2,1 m²K/W) 20 10 >20 10 50 20 50 220 30 220 30 Cladding Fassadenplatte Battens 80/20 Fassadenplatte Perimeter insulation including drainage Lattung Dampproofing Perimeterdämmung mit Drainage Reinforced concrete Feuchtigkeitsabdichtung Insulation Stahlbeton Halsdämmung (h~500) Building component used awmohi 01a, Floor above basement in accordance with figure, Basement wall in accordance with figure Additional building materials Adhesive tape, Bird screen Wartungs-/Austauschintervall interval for the wall Maintenance/replacement für die Sockelverkleidung base lining 5 - 10 years 5 - 10 Jahre dataholz.com ā Catalogue of timber building materials, components and component connections reviewed to consider thermal, acoustic, fire performance requirements and ecological drivers for timber construction released by accredited testing institutes. These datasheets will generally be accepted as proofs of compliance by building authorities in Austria. 1/3 dataholz.com Designation: awmxsom01 Version: 13.05.2008 Source: TU-Graz/Labor für Bauphysik Institut für Hoch- und Industriebau Preparation: TUG, HE External wall - Wall base connection with wood cladding Joining technique, erection sequence (1 ... n) 2 5 6 4 3 1 dataholz.com ā Catalogue of timber building materials, components and component connections reviewed to consider thermal, acoustic, fire performance requirements and ecological drivers for timber construction released by accredited testing institutes. These datasheets will generally be accepted as proofs of compliance by building authorities in Austria. 2/3 dataholz.com Designation: attachment wall base parapet connection Version: 13.05.2008 Source: TU-Graz/Labor für Bauphysik Institut für Hoch- und Industriebau Preparation: TUG, HE Attachment wall base connection solid walls Vertical section Horizontal section WICHTIG: Fastening of the façade in accordance with structural design requirements Important! VERANKERUNGEN NACH DEM Anchoring has to be put in place after VERKLEBEN DER STOSSFUGEN SETZEN!!!! bonding of the joint! nach statischen Erfordernissen JointStoßfugen sealed with suitable adhesive tape to mit geeignetem Klebeband konvektionsdicht verkleben prevent convection 75 200 Bird screen Vogelschutzgitter >300 Fassadenbefestigung lt. Statik Number and size of anchors in accordance Größestructural und Anzahldesign der Verankerungen with requirements 50 50 Precast concrete component Perimeter insulation including drainage Dampproofing 220 Reinforced concrete 30 Insulation Building component used awmoho 01a Axiometric view Additional building materials Adhesive tape dataholz.com ā Catalogue of timber building materials, components and component connections reviewed to consider thermal, acoustic, fire performance requirements and ecological drivers for timber construction released by accredited testing institutes. These datasheets will generally be accepted as proofs of compliance by building authorities in Austria. 3/3