pixis: 100 - Princeton Instruments
Transcription
pixis: 100 - Princeton Instruments
SPECTROSCOPY GROUP Now Powered by LightField™ PIXIS: 100 1340 x 100 The PIXIS series from Princeton Instruments (PI) are fully integrated, low noise cameras with a 1340 pixel format designed for quantitative scientific optical spectroscopy applications. Based on PI’s exclusive XP cooling technology, PIXIS cameras offer thermoelectric cooling down to -80°C, with an all-metal, hermetically sealed design and the industry’s only lifetime vacuum guarantee. High QE and ultra low-noise electronics make the PIXIS series of cameras ideal for demanding, low light applications such as Raman spectroscopy, photo- and electroluminescence, fluorescence and reflectance spectroscopy. Princeton Instruments’ exclusive eXcelon® technology delivers the highest sensitivity available from the deep UV to the NIR, while suppressing the etaloning that occurs in conventional back-thinned devices. Dual speed operation at 100 kHz or 2 MHz enables these cameras to be used for either long acquisitions or fast kinetic studies. FEATURE BENEFITS eXcelon™ technology Increases detector sensitivity while suppressing etalon interference fringes observed in the NIR with conventional back-illuminated devices. Permanent vacuum Our all-metal brazed seals eliminate the outgassing that occurs with epoxy seals and allows us to offer the industry’s only lifetime vacuum guarantee. Low temperature operation minimizes dark current without the need for liquid nitrogen. Deep thermoelectric cooling Single fused silica vacuum window Minimizes reflection losses from the UV to the IR; Optional AR coating and wedge windows are available. 1340 x100 imaging array, 20 mm x 20 mm pixels Proprietary format with 2 mm height for rapid spectral acquisition; 20 mm pixel size offers the optimal combination of high resolution with dynamic range. Optional UV phosphor coatings TTL input and output and shutter control 100 kHz and 2 MHz digitization rates Enhances sensitivity throughout the UV to below 200 nm. External control and triggering. Choose low speed digitization for low noise or high speed for fast spectral acquisition. Dual amplifiers with software-selectable system gains High sensitivity amplifier reduces read noise floor for weak signals while a high capacity amplifier increases dynamic range. USB2.0 data interface Plug-and-play operation with desktops or laptops; Optional fiber optic interface for remote operation. Optional: LightField® (for Windows 8/7, 64-bit) Or WinView/Spec (for Windows 8/7/XP, 32-bit) Flexible software packages for data acquisition, display and analysis; LightField offers intuitive, cutting edge user interface, IntelliCal® and more. PICAM (64-bit) / PVCAM (32-bit) software development kits (SDKs) Compatible with Windows 8/7/XP, and Linux; Universal programming interfaces for easy custom programming. Applications: Raman Spectroscopy, Absorbance, Emission, Fluorescence and Reflectance Spectroscopy Page 1 of 6 PIXIS: 100 eXcelon Rev. N5.1 SPECTROSCOPY GROUP SPECIFICATIONS Features Dark current @ -80°C (e-/p/sec) PIXIS: 100BR_eXcelon PIXIS: 100BR PIXIS: 100F Back-illuminated, deep depletion CCD. High QE in the NIR with minimal etaloning. PIXIS: 100B_eXcelon Back-illuminated CCD with eXcelon technology. Enhanced sensitivity in the UV and the NIR with low etaloning. PIXIS: 100B Back-illuminated, deep depletion CCD with eXcelon technology. Highest average QE from the UV to the NIR with negligible etaloning. Back-illuminated CCD. Highest QE in the visible with low dark current. Subject to etaloning in the NIR. Front-illuminated CCD. Affordable technology for moderate light level applications. No etaloning. 0.03 (typical) 0.03 (typical) 0.001 (typical) 0.001 (typical) 0.0008 (typical) CCD format Imaging area Optical mount Deepest cooling temperature Thermostating precision Cooling method Spectrometric Well Capacity: High Sensitivity High Capacity ADC speed/bits System read noise @100 kHz @2 MHz Vertical shift speed Non-linearity Software selectable gains Operating systems supported Data interface I/O signals Operating environment Certification Dimensions / Weight 1340 x 100, 20 x 20 mm pixels with 100% fill factor 26.8 x 2.0 mm (optically centered) Princeton Instruments’ Acton spectrometer adapter with optional shutter -80°C guaranteed ±0.05°C Thermoelectric air or liquid cooling; CoolCUBE II, a compact room temperature coolant circulator, is available for vibration sensitive environments 300 ke- (typical), 250 ke- (min) 1 Me- (typical), 750 ke- (min) 100 kHz/16-bit and 2 MHz/16-bit Front-illuminated 2.5 e- rms (typical), 4 e- rms (max) 10 e- rms (typical), 15 e- rms (max) Back-illuminated 3 e- rms (typical), 5 e- rms (max) 11 e- rms (typical), 16 e- rms (max) < 15 msec/row (programmable) < 1% @ 100 kHz 1, 2, 4 e- (high sensitivity); 4, 8, 16 e- (high capacity); available at all speeds Windows 8/7/XP (32-bit), Windows 8/7 (64-bit) and Linux USB2.0 Two MCX to BNC connectors for programmable frame readout, shutter, trigger in +5 to +30°C, non-condensing atmosphere CE 16.3 cm (6.43") x 11.8 cm (4.65") x 11.4 cm (4.48") (L x W x H) / 2.27 kg (5 lbs) All specifications are subject to change. SPECTRAL RATE @ 100 kHz Full Vertical Binning (FVB) @ 2 MHz @ 2 MHz Full Vertical Binning (FVB) (0.2 mm high) 70 fps 750 fps 1300 fps Page 2 of 6 PIXIS: 100 eXcelon Rev. N5.1 SPECTROSCOPY GROUP QE DATA 100% 90% 80% Quantum Efficiency (%) 70% 60% 50% 40% 30% 20% 10% 0% 250 300 BR_eXcelon 350 400 450 500 550 B_eXcelon 600 650 700 BR 750 B 800 850 900 950 1000 1050 With optional UV coating F Wavelength (nm) NOTE: Graph shows typical Quantum Efficiency (QE) data measured at + 25°C. QE decreases at normal operating temperatures. For the best results for your application, please discuss the specific parameters of your experiment with your sales representative. VACUUM WINDOW AR COATINGS 100 95 NOTES: Standard anti-reflection (AR) coating options shown on graph Designed by Acton Optics, our BBAR coating offers unmatched performance for 400 nm - 1100 nm Custom wedge window options and other AR coatings are also available Contact your local sales representative for more information Transmission (%) 90 85 80 NIR -AR 75 NO -AR 70 MgF2 65 BBAR (400 -1100nm) 60 55 50 200 300 400 500 600 700 800 900 1000 Wavelength (nm) Page 3 of 6 PIXIS: 100 eXcelon Rev. N5.1 eXcelon Performance SPECTROSCOPY GROUP Back-illuminated Data taken with white light source through a monochromator, comparing etaloning performance of eXcelon vs. back-illuminated CCDs. Back-illuminated_eXcelon Etalon Oscillations (B_eXcelon vs. B) QE Improvement (B_eXcelon vs. B) 14 0.15 QE Data measured at +25˚C 12 0.10 QE Improvement (B_eXcelon -B) 10 Relative Amplitude 8 6 4 0.05 0 -0.05 2 -0.10 0 B_eXcelon -2 B -0.15 600 650 700 750 800 -4 350 450 550 650 750 850 950 850 900 950 1000 1050 1100 Wavelength (nm) 1050 Wavelength (nm) B_eXcelon provides superior QE over the standard back illuminated (“B”) version in the UV-NIR range. B_eXcelon provides significantly lower etaloning (unwanted fringes) compared to standard back illuminated (“B”) version. QE Improvement (BR_eXcelon vs. BR) Etalon Oscillations (BR_eXcelon vs. BR) 50 0.15 QE Data measured at +25˚C 45 40 30 0.05 Relative Amplitude QE Improvement (BR_eXcelon - BR) 0.10 35 25 20 15 0 -0.05 10 BR_eXcelon BR 5 -0.10 0 -5 350 450 550 650 750 850 950 1050 Wavelength (nm) BR_eXcelon provides superior QE over standard back illuminated deep depletion (“BR”) version over the entire UV-NIR range. -0.15 600 650 700 750 800 850 900 950 1000 1050 Wavelength (nm) BR_eXcelon eliminates much of the residual etaloning observed in the standard back-illuminated deep depletion (“BR”) version. Page 4 of 6 PIXIS: 100 eXcelon Rev. N5.1 SPECTROSCOPY GROUP PIXIS DRAWINGS (AIR COOLED) PIXIS with Spectroscopy Mount / 2.27 KG PIXIS with Spectroscopy Mount; with Shutter / 2.27 KG Page 5 of 6 PIXIS: 100 eXcelon Rev. N5.1 SPECTROSCOPY GROUP PIXIS DRAWINGS (LIQUID COOLED) www.princetoninstruments.com info@princetoninstruments.com TOLL-FREE +1.877.474.2286 | PHONE +1 609.587.9797 Visit the Princeton Instruments website to find a representative in your area. Page 6 of 6 PIXIS: 100 eXcelon Rev. N5.1
Similar documents
pixis: 2k - Princeton Instruments
27.6 x 6.9 mm (optically centered) Princeton Instruments Acton spectrometer adapter with optional shutter -75°C guaranteed ±0.05°C Thermoelectric air or liquid cooling (CoolCUBE II required)
More information