mahnrub ar-esab y
IN S TAL L AT ION MAN U AL F OR BU R N H A M BA S E -R A Y ® TABLE OF CONTENTS PAGE 2 I=B=R RATINGS 8 INSTALLATION DETAILS 9 INSTALLATION INSTRUCTIONS 4 ASSEMBLY CHART 5 SYSTEM TYPES 10 ASSEMBLY INSTRUCTIONS 6 SERIES LOOP SYSTEMS 14 SPECIAL APPLICATIONS 7 SERIES LOOP DESIGN 16 WARRANTY H e a t i ng C o nt r a c t o r Ins t a lla t i o n D a t e A d d re s s P ho ne N um b e r 81441001R8-3/06 Price - $2.00 For Ratings at the following temperatures, multiply the 150° rating by the multiplier of the desired temperature. Temperature – Multiplier 130° - .68 120° - .54 150° - 1.0 110° - .42 100° - .32 140° - .82 No. 9A Base-Ray® I=B=R Ratings – Steam and Hot Water (500 LBS/HR Flow Rate **) L e ng th i n L i ne a l F e e t* S te a m Ra ti ng S q ua re F e e t P e r L i n. F t. 1 .5 2 .0 2 .5 3 .0 3 .5 4 .0 4 .5 5 .0 5 .5 6 .0 6 .5 7 .0 7 .5 8 .0 8 .5 9 .0 9 .5 1 0 .0 1 0 .5 11 .0 11 .5 1 2 .0 1 2 .5 1 3 .0 1 3 .5 1 4 .0 1 4 .5 1 5 .0 1 5 .5 1 6 .0 1 6 .5 1 7 .0 1 7 .5 1 8 .0 1 8 .5 1 9 .0 1 9 .5 2 0 .0 2 0 .5 2 1 .0 2 1 .5 2 2 .0 3 .4 0 5 .1 6 .8 8 .5 1 0 .2 11 .9 1 3 .6 1 5 .3 1 7 .0 1 8 .7 2 0 .4 2 2 .1 2 3 .8 2 5 .5 2 7 .2 2 8 .9 3 0 .6 3 2 .3 3 4 .0 3 5 .7 3 7 .4 3 9 .1 4 0 .8 4 2 .5 4 4 .2 4 5 .9 4 7 .6 4 9 .3 5 1 .0 5 2 .7 5 4 .4 5 6 .1 5 7 .8 5 9 .5 6 1 .2 6 2 .9 6 4 .6 6 6 .3 6 8 .0 6 9 .7 7 1 .4 7 3 .1 7 4 .8 S te a m Ra ti ng B .T.U. P e r Hr. A t 2 1 5 °F 820 1230 1640 2050 2460 2870 3280 3690 4100 4510 4920 5330 5740 6150 6560 6970 7380 7790 8200 8610 9020 9430 9840 10250 10660 11 0 7 0 11 4 8 0 11 8 9 0 12300 12710 13120 13530 13940 14350 14760 15170 15580 15990 16400 16810 17220 17630 18040 I=B=R Ratings are determined from tests made in accordance with the I=B=R Testing and Rating Code for Baseboard Type of Radiation, including an allowance of 15% for heating effect permitted by the Code. Ratings based on active length. Active length same as total length. 2 2 3 0 °F 890 1340 1780 2230 2670 3120 3560 4010 4450 4900 5340 5790 6230 6680 7120 7570 8010 8460 8900 9350 9790 10240 10680 111 3 0 11 5 7 0 12020 12460 12910 13350 13800 14240 14690 15130 15580 16020 16470 16910 17360 17800 18250 18690 19140 19580 HOT WATE R RATINGS IN B TU P E R HOUR AT 5 0 0 L B S ./HR. (ONE G.P.M.) F L OW RATE ** AT AV E RA GE WA E R TE MP E RATURE OF 1 8 0 °F 1 7 0 °F 2 2 0 °F 2 1 0 °F 2 0 0 °F 1 9 0 °F 830 770 710 650 590 520 1250 11 6 0 1070 980 890 780 1300 11 8 0 1040 1660 1540 1420 2080 1930 1780 1630 1480 1300 2490 2310 2130 1950 1770 1560 2280 2070 1820 2910 2700 2490 3320 3080 2840 2600 2360 2080 3740 3470 3200 2930 2660 2340 4150 3850 3550 3250 2950 2600 4570 4240 3910 3580 3250 2860 4980 4620 4260 3900 3540 3120 5400 5010 4620 4230 3840 3380 5810 5390 4970 4550 4130 3640 6230 5780 5330 4880 4430 3900 6640 6160 5680 5200 4720 4160 7060 6550 6040 5530 5020 4420 7470 6930 6390 5850 5310 4680 7890 7320 6750 6180 5610 4940 8300 7700 7100 6500 5900 5200 8715 8090 7460 6830 6200 5460 9130 8470 7810 7150 6490 5720 9550 8860 8170 7480 6790 5980 7080 6240 9960 9240 8520 7800 10380 9630 8880 8130 7380 6500 10790 10010 9230 8450 7670 6760 11 2 1 0 1 0 4 0 0 9590 8780 7970 7020 11 6 2 0 1 0 7 8 0 9940 9100 8260 7280 1 2 0 4 0 111 7 0 1 0 3 0 0 9 4 3 0 8550 7540 1 2 4 5 0 11 5 5 0 1 0 6 5 0 9 7 5 0 8850 7800 1 2 8 7 0 11 9 4 0 11 0 1 0 1 0 0 8 0 9150 8060 1 3 2 8 0 1 2 3 2 0 11 3 6 0 1 0 4 0 0 9440 8320 1 3 7 0 0 1 2 7 1 0 11 7 2 0 1 0 7 3 0 9470 8580 10030 8840 1 4 11 0 1 3 0 9 0 1 2 0 7 0 11 0 5 0 1 4 5 3 0 1 3 4 8 0 1 2 4 3 0 11 3 8 0 10330 9100 1 4 9 4 0 1 3 8 6 0 1 2 7 8 0 11 7 0 0 10620 9360 15360 14250 13140 12030 10920 9620 15770 14630 13490 12350 11 2 1 0 9880 16190 15020 13850 12680 11 5 1 0 1 0 1 4 0 16600 15400 14200 13000 11 8 0 0 1 0 4 0 0 17020 15790 14560 13330 12100 10660 17430 16170 14910 13650 12390 10920 1 7 8 5 0 1 6 5 6 0 1 5 2 7 0 1 3 9 8 0 1 2 6 9 0 111 8 0 1 8 2 6 0 1 6 9 4 0 1 5 6 2 0 1 4 3 0 0 1 2 9 8 0 11 4 4 0 1 5 0 °F 390 585 780 975 11 7 0 1365 1560 1755 1950 2145 2340 2535 2730 2925 3120 3315 3510 3705 3900 4095 4290 4485 4680 4785 5070 5265 5460 5655 5850 6045 6240 6435 6630 6825 7020 7215 7410 7605 7800 7995 8190 8385 8580 P re s s ure D ro p i n Inc he s o f Wa te r*** .1 0 .1 0 .11 .1 2 .1 3 .1 4 .1 4 .1 5 .1 6 .1 7 .1 8 .1 8 .1 9 .2 0 .2 1 .2 2 .2 2 .2 3 .2 4 .2 5 .2 6 .2 6 .2 7 .2 8 .2 9 .3 0 .3 0 .3 1 .3 2 .3 3 .3 4 .3 4 .3 5 .3 6 .3 7 .3 8 .3 8 .3 9 .4 0 .4 1 .4 2 .4 2 **The Hot Water Ratings at 500 lb. Flow Rate are based on a standard water Àow rate of 500 lbs. per hour (one gallon per minute) through the Base-Ray. These ratings should be used for all installations except as noted under 2000 Lb. Flow Rate. *Add ½" to length for each bushing. Add 5" to length for each valve enclosure. ***Based on ¾" pipe connections. For Ratings at the following temperatures, multiply the 150° rating by the multiplier of the desired temperature. Temperature – Multiplier 150° - 1.0 130° - .68 140° - .82 120° - .54 110° - .42 No. 9A Base-Ray® I=B=R Ratings – Steam and Hot Water (2000 LBS/HR Flow Rate **) L e ng th i n L i ne a l F e e t* S te a m Ra ti ng S q ua re F e e t P e r L i n. F t. 1 .5 2 .0 2 .5 3 .0 3 .5 4 .0 4 .5 5 .0 5 .5 6 .0 6 .5 7 .0 7 .5 8 .0 8 .5 9 .0 9 .5 1 0 .0 1 0 .5 11 .0 11 .5 1 2 .0 1 2 .5 1 3 .0 1 3 .5 1 4 .0 1 4 .5 1 5 .0 1 5 .5 1 6 .0 1 6 .5 1 7 .0 1 7 .5 1 8 .0 1 8 .5 1 9 .0 1 9 .5 2 0 .0 2 0 .5 2 1 .0 2 1 .5 2 2 .0 3 .4 0 5 .1 6 .8 8 .5 1 0 .2 11 .9 1 3 .6 1 5 .3 1 7 .0 1 8 .7 2 0 .4 2 2 .1 2 3 .8 2 5 .5 2 7 .2 2 8 .9 3 0 .6 3 2 .3 3 4 .0 3 5 .7 3 7 .4 3 9 .1 4 0 .8 4 2 .5 4 4 .2 4 5 .9 4 7 .6 4 9 .3 5 1 .0 5 2 .7 5 4 .4 5 6 .1 5 7 .8 5 9 .5 6 1 .2 6 2 .9 6 4 .6 6 6 .3 6 8 .0 6 9 .7 7 1 .4 7 3 .1 7 4 .8 S te a m Ra ti ng B .T.U. P e r Hr. A t 2 1 5 °F 820 1230 1640 2050 2460 2870 3280 3690 4100 4510 4920 5330 5740 6150 6560 6970 7380 7790 8200 8610 9020 9430 9840 10250 10660 11 0 7 0 11 4 8 0 11 8 9 0 12300 12710 13120 13530 13940 14350 14760 15170 15580 15990 16400 16810 17220 17630 18040 2 3 0 °F 940 1410 1880 2350 2820 3290 3760 4230 4700 5170 5640 6 11 0 6580 7050 7520 7990 8460 8930 9400 9870 10340 10810 11 2 8 0 11 7 5 0 12220 12690 13160 13630 14100 14570 15040 15510 15980 16450 16920 17390 17860 18330 18800 19270 19740 20210 20680 I=B=R Ratings are determined from tests made in accordance with the I=B=R Testing and Rating Code for Baseboard Type of Radiation, including an allowance of 15% for heating effect permitted by the Code. Ratings based on active length. Active length same as total length. HOT WATE R RATINGS IN B TU P E R HOUR AT 2 0 0 0 L B S ./HR. (F OUR G.P.M.) F L OW RATE ** AT AV E RA GE WA E R TE MP E RATURE OF 1 8 0 °F 1 7 0 °F 2 2 0 °F 2 1 0 °F 2 0 0 °F 1 9 0 °F 880 810 750 690 620 550 1320 1220 11 3 0 1040 930 830 1500 1380 1240 11 0 0 1760 1620 2200 2030 1880 1730 1550 1380 2640 2430 2250 2070 1860 1650 3080 2840 2630 2420 2170 1930 3520 3240 3000 2760 2480 2200 3960 3650 3380 3 11 0 2790 2480 4400 4050 3750 3450 3100 2750 4840 4460 4130 3800 3410 3030 5280 4860 4500 4140 3720 3300 5720 5270 4880 4490 4030 3580 6160 5670 5250 4830 4340 3850 4130 6600 6080 5630 5180 4650 7040 6480 6000 5520 4960 4400 7480 6890 6380 5870 5270 4680 7920 7290 6750 6210 5580 4950 8360 7700 7130 6560 5890 5230 8800 8100 7500 6900 6200 5500 9240 8510 7880 7250 6510 5780 9680 8910 8250 7590 6820 6050 10120 9320 8630 7940 7130 6330 10560 9720 9000 8280 7440 6600 11 0 0 0 1 0 1 3 0 9380 8630 7750 6880 11 4 4 0 1 5 0 3 0 9750 8970 8060 7150 11 8 8 0 1 0 9 4 0 1 0 1 3 0 9 3 2 0 8370 7430 1 2 3 2 0 11 3 4 0 1 0 5 0 0 9 6 6 0 8680 7700 1 2 7 6 0 11 7 5 0 1 0 8 8 0 1 0 0 1 0 8990 7960 1 3 2 0 0 1 2 1 5 0 11 2 5 0 1 0 3 5 0 9300 8250 1 3 6 4 0 1 2 5 6 0 11 6 3 0 1 0 7 0 0 9610 8530 1 4 0 8 0 1 2 9 6 0 1 2 0 0 0 11 0 4 0 9920 8800 1 4 5 2 0 1 3 3 7 0 1 2 3 8 0 11 3 9 0 10230 9080 1 4 9 6 0 1 3 7 7 0 1 2 7 5 0 11 7 3 0 10540 9350 15400 14180 13130 12080 10850 9630 15840 14580 13500 12420 111 6 0 9900 16280 14990 13880 12770 11 4 7 0 1 0 1 8 0 1 6 7 2 0 1 5 3 9 0 1 4 2 5 0 1 3 11 0 11 7 8 0 1 0 4 5 0 17160 15800 14630 13460 12090 10730 1 7 6 0 0 1 6 2 0 0 1 5 0 0 0 1 3 8 0 0 1 2 4 0 0 11 0 0 0 1 8 0 4 0 1 6 6 1 0 1 5 3 8 0 1 4 1 5 0 1 2 7 1 0 11 2 8 0 1 8 4 8 0 1 7 0 1 0 1 5 7 5 0 1 4 4 9 0 1 3 0 2 0 11 5 5 0 1 8 9 2 0 1 7 4 2 0 1 6 1 3 0 1 4 8 4 0 1 3 3 3 0 11 8 3 0 19360 17820 16500 15180 13640 12100 1 5 0 °F 410 615 820 1025 1230 1435 1640 1845 2050 2255 2460 2665 2870 3075 3280 3485 3690 3895 4100 4305 4510 4715 4920 5125 5330 5535 5740 5945 6150 6355 6560 6765 6970 7175 7380 7585 7790 7995 8200 8405 8610 8815 9020 P re s s ure D ro p i n Inc he s o f Wa te r*** 1 .2 9 1 .3 9 1 .5 0 1 .6 1 1 .7 1 1 .8 2 1 .9 3 2 .0 3 2 .1 4 2 .2 5 2 .3 5 2 .4 6 2 .5 7 2 .6 8 2 .7 8 2 .8 9 3 .0 0 3 .1 0 3 .2 1 3 .3 2 3 .4 2 3 .5 3 3 .6 4 3 .7 4 3 .8 5 3 .9 6 4 .0 6 4 .1 7 4 .2 8 4 .3 8 4 .4 9 4 .6 0 4 .7 0 4 .8 1 4 .9 2 5 .0 3 5 .1 3 5 .2 4 5 .3 5 5 .4 5 5 .5 6 5 .6 7 **The Hot Water Ratings at 2000 lb. Flow Rate are limited to installations where the water Àow rate through the Base-Ray is greater than 2000 lbs. per hour (four gallons per minute). Where the water Àow rate through the Base-Ray is not known, the rating at the standard Àow rate of 500 lbs. per hour must be used. *Add ½" to length for each bushing. Add 5" to length for each valve enclosure. ***Based on ¾" pipe connections. 9A Base-Ray Water Content - 2.5 lbs. or .3 gal. per linear ft. 3 Dimensions and Speci¿cations Use of PTFE (TeÀon®) tape or paste containing PTFE is not recommended as overtightening is possible, causing cracking of the Base Ray tappings. BASE-RAY TAPPINGS- Tapped 3/4" top and bottom of end sections. A 3/4" x 1/8" vent bushing is furnished with each Base-Ray Assembly. Only one air vent location need be used. Sub-Assembly Chart Copper tubing is not recommended for steam applications due to high heat loss through the tubing and thermal expansion noise. Maximum recommended length for steam applications is 10 lineal feet. Base-Ray® Assembly Chart BASE-RAY Assemblies up to and including 6 lineal ft. are shipped in one piece. Longer Assemblies are shipped in two or more pieces or subassemblies, none of which exceeds 6 lineal ft. A S S E MB L IE S A ND S UB -A S S E MB L IE S A RE MA D E UP OF F OL L OWING S E C TIONS A S S E MB L IE S 18" L e ft E nd 24" L e ft E nd 1 ½ F t. A s s e mb ly --- --- 24" 12" 18" 24" 2 4 " Int. Ri g ht Ri g ht P a ne l P a ne l E nd E nd --- --- --- 1 --- AS S E MB LY L E N GT H L .H . C EN TER R .H . 6 ½ F t. 5 ½ F t. --- 1 F t. 7 F t. 6 F t. --- 1 F t. 7 ½ F t. 5 ½ F t. --- 2 F t. 8 F t. 6 F t. --- 2 F t. 8 ½ F t. 5 ½ F t. --- 3 F t. 9 F t. 6 F t. --- 3 F t. 9 ½ F t. 5 ½ F t. --- 4 F t. 1 0 F t. 6 F t. --- 4 F t. 1 0 ½ F t. 5 ½ F t. --- 5 F t. 11 F t. 6 F t. --- 5 F t. 11 ½ F t. 5 ½ F t. --- 6 F t. 1 2 F t. 6 F t. --- 6 F t. 1 2 ½ F t. 5 ½ F t. 6 F t. 1 F t. 1 3 F t. 6 F t. 6 F t. 1 F t. 1 3 ½ F t. 5 ½ F t. 6 F t. 2 F t. 1 4 F t. 6 F t. 6 F t. 2 F t. 1 4 ½ F t. 5 ½ F t. 6 F t. 3 F t. 1 5 F t. 6 F t. 6 F t. 3 F t. 1 5 ½ F t. 5 ½ F t. 6 F t. 4 F t. 6 F t. 6 F t. 4 F t. 2 F t. A s s e mb ly --- --- --- --- --- --- 1 1 6 F t. 2 ½ F t. A s s e mb ly 1 --- --- --- 1 --- --- 1 6 ½ F t. 5 ½ F t. 6 F t. 5 F t. --- 1 7 F t. 6 F t. 6 F t. 5 F t. 3 F t. A s s e mb ly --- 1 --- --- 1 --- 3 ½ F t. A s s e mb ly 1 --- --- 1 --- --- --- 1 7 ½ F t. 5 ½ F t. 6 F t. 6 F t. 4 F t. A s s e mb ly --- 1 --- 1 --- --- --- 1 8 F t. 6 F t. 6 F t. 6 F t. 4 ½ F t. A s s e mb ly 1 --- 1 --- 1 --- --- 1 8 ½ F t. 5 ½ F t. 2 - 6 F t. 1 F t. 5 F t. A s s e mb ly --- 1 1 --- 1 --- --- 1 9 F t. 6 F t. 2 - 6 F t. 1 F t. 5 ½ F t. A s s e mb ly 1 --- 1 1 --- --- --- 1 9 ½ F t. 5 ½ F t. 2 - 6 F t. 2 F t. 6 F t. A s s e mb ly --- 1 1 1 --- --- --- 2 0 F t. 6 F t. 2 - 6 F t. 2 F t. 2 0 ½ F t. 5 ½ F t. 2 - 6 F t. 3 F t. 2 1 F t. 6 F t. 2 - 6 F t. 3 F t. 2 1 ½ F t. 5 ½ F t. 2 - 6 F t. 4 F t. S UB -A S S E MB L IE S 5 ½ F t. L .H. S ub -A s s y. 6 F t. L .H. S ub -A s s y. 4 1 --- --1 2 2 6 F t. C e nte r S ub -A s s y. --- --- 3 A ll R.H. S ub -A s s y. --- --- Re q ui re d Numb e r ------- ------- 1 or 1 ----- ----- --- --- --- --- 2 2 F t. 6 F t. 2 - 6 F t. 4 F t. 2 2 ½ F t. 5 ½ F t. 2 - 6 F t. 5 F t. 2 3 F t. 6 F t. 2 - 6 F t. 5 F t. 2 3 ½ F t. 5 ½ F t. 2 - 6 F t. 6 F t. 2 4 F t. 6 F t. 2 - 6 F t. 6 F t. BASE-RAY® HYDRONICS Types of Systems Hydronic Heating Systems are classi¿ed according to the piping arrangement and heating medium employed. BASE-RAY is very versatile in that it may be used in almost all types of systems as noted below: 1. Series Loop Forced Circulation Hot Water 2. One-Pipe Forced Circulation Hot Water 3. Two-Pipe Reverse Return Gravity or Forced Circulation Hot Water 4. Two-Pipe Steam or Vapor. It is not recommended that BASE-RAY be used in a One-Pipe Steam System. System Description 1. Series Loop is a forced circulation hot water heating system with the BASE-RAY Assemblies connected so that all the water Àowing through a circuit passes through each seriesconnected Assembly in the circuit. Thus, the Assemblies serve as portions of the main. 2. One-Pipe is a forced circulation hot water heating system utilizing one continuous main from boiler supply to boiler return. BASE-RAY Assemblies are connected to this pipe or main by two smaller pipes known as branches. When connecting these branches to the main, one of the standard tees is replaced by a special tee frequently called a one-pipe ¿tting. These one-pipe ¿ttings cause a portion of the water Àowing through the main to pass through the BASE-RAY Assemblies and back to the main again. 3. Two-Pipe Reverse Return is a gravity or forced circulation hot water heating system utilizing one main to carry heated water from the boiler to the BASE-RAY Assemblies and a second main to carry the cooled water from the Assemblies back to the boiler. The Assemblies are connected to the return main in the reverse order from that in which they are connected to the supply main. Very few designers use this type of system for residential applications, since there is no difference between the heating qualities of this system and the other two hot water systems. 4. Two-Pipe Steam or Vapor Systems are steam systems in which each BASE-RAY Assembly is provided with two piping connections, and where steam and condensate Àow in separate mains and branches. The Vapor system differs from the low pressure system only in the type of air valve used. 5 SERIES LOOP SYSTEMS Installation Data This type of installation, in which the BASE-RAY® Assemblies serve as part of the main, is the most economical way BASE-RAY can be installed. Substantial savings in labor and material are realized in that one-pipe ¿ttings, shut-off valves, balancing cocks and additional piping are eliminated. Quality is not sacri¿ced as tests have proven the ability of a Series Loop System to produce comfort conditions equal to those produced by other hydronic heating systems. Series Loop Systems are ideal for homes without basements, especially those built on concrete slabs, as it eliminates the necessity for running the mains in the attic or in the concrete slab. With proper design, the Series Loop System can be used to advantage in apartment construction. As indicated in the adjacent piping diagrams, the supply runs from the boiler to the ¿rst BASE-RAY Assembly in the circuit and then from Assembly to Assembly, dropping below the Àoor only when necessary to avoid obstructions such as doors, ¿replaces, etc. BASE-RAY Baseboard Extensions are used to conceal the piping run above the Àoor. It is sound practice to run a loop around an ordinary 5 or 6 room house. In the case of very small two-story homes, the loop may take in both ¿rst Àoor and second Àoor rooms. Larger ranch style, two-story and split level homes may use two separate loops running from the same supply line and coming back into the common return line. An example of this is shown (lower right) where the rooms on each Àoor are on a separate loop. In some two-story homes it might be desirable to put part of each Àoor on one loop and the other portions of each Àoor on a second loop. Do not include three stories on one loop. In multiple loop systems, a valve should be placed at the return end of each loop for balancing. EXPANSION – BASE-RAY Assemblies and connecting piping will vary in length with water temperature changes in the system. To prevent distortion or noise as this expansion takes place, adequate measures must be provided in the system design and by the installer. Proper location of breaks in a run when the piping must drop through the Àoor to clear obstructions such as doors and ¿replaces, expansion ¿ttings, use of Àexible tubing at the end of a run, offsetting the vertical risers in adequate size holes (1¼” holes for ¾” copper tubing, 1¼” x 1½” elongated holes for ¾” steel pipe) – all provide for expansion and make for a quality installation. In systems where high boiler water temperature must be maintained for domestic hot water, length of BASE-RAY Assemblies between two inside adjacent corners (when BASE-RAY is on three walls) should not exceed 25-feet, unless there is an expansion break between or swing joint provided at end. See SPECIAL APPLICATIONS, page 14. It is also desirable on these types of systems to provide a by-pass and mixing valve between boiler supply and return so that in mild weather, temperature changes in the system will be gradual instead of rapid. BALANCING SYSTEM – System should be balanced on days when average winter temperatures prevail outdoors. 6 To Design Series-Loop Base-Ray® Installation – 1. Calculate the Heat Loss of each room using the procedure outlined in the I=B=R Heat Loss Calculation Guide No. H-21 or the ASHRAE Guide. 2. Using 210°F as design water temperature and 500 lbs/hr. as Àow rate, select length of BASE-RAY Assembly for each room to produce desired output. (Design water temperature other than 210°F may be used but should not exceed 230°F.) If system designed on 20°F drop, this 210°F average water temperature means roughly, that under maximum load conditions, the water leaves the boiler at 220°F and returns at 200°F and returns at 200°F. Since maximum load conditions occur only at rare intervals, the system usually operates at considerably lower water temperatures. If, for a given output, the total length of the loop exceeds the values shown in Table A, the loop may be split into two circuits – see Illustration. Check load-length of each circuit. Determine from Table B if 1” trunk is adequate. 3. Locate BASE-RAY Assemblies on Floor Plan drawn to scale. 4. Layout Piping on Floor Plan as illustrated. Since the temperature of the water decreases progressively from the ¿rst Heating Unit to the Last Heating Unit on a circuit, the system should be laid out, if possible, so that the Heating Units with the hotter water are in areas such as the living room, bath and dining room. Heating Units in bedrooms, kitchen and similar areas should be located on the end of the loop. 5. Measure length of Circuit (horizontal and vertical) from boiler supply to boiler return (include BASE-RAY lengths). In Series Loop Systems, on rare instances a BASE-RAY Assembly, Radiant Radiator or Slenderized Radiator is connected to the main with branches. Since a one-pipe ¿tting is used, add 12 additional feet to the measured length to obtain total length of Circuit. 6. Knowing the load-length of the loop from Steps 2 and 5 above, Table A will indicate whether or not a standard ¾” or 1” circulator is adequate. TABLE A TABLE B B tu/Hr. Outp ut o f B A S E -RAY A s s e mb li e s E a c h Loop To ta l L e ng th o f L o o p F t. B tu/Hr. Outp ut o f B A S E -RAY A s s e mb li e s A ll Loops L e ng th o f L o ng e s t L o o p - F t. 40,000 100 50,000 240 35,000 135 55,000 210 30,000 175 60,000 165 25,000 260 65,000 140 70,000 120 NOTE : Ta b le b a s e d o n 2 0 °F D ro p thro ug h C i rc ui t - ¾" p i p i ng NOTE : Ta b le b a s e d o n he a d d e ve lo p e d b y Sta nd a rd ¾" o r 1 " c i rc ula to r - 2 0 °F D ro p thro ug h s ys te m. For Piping Arrangements and Design conditions other than those given above, follow procedure outlined in I=B=R Installation Guide No. 200. 7 Installation Details A BASE-RAY® heating system is extremely easy to install – no other heating system requires less labor. The same installation practices that are used in an ordinary radiator system are followed. Use conventional methods in selecting boiler and pipe sizes, including mains, risers and branches. Supply and return connections to BASE-RAY are made in the same way as with conventional radiators. I=B=R Installation Guide No. 200 for Hydronic Heating Systems shows installation details for both the conventional piping system and the Series Loop System. LOCATION OF BASE-RAY BASE-RAY should be placed along exposed walls in place of the regular wood baseboard. If the outside walls do not provide suf¿cient space, place additional assemblies on inside wall. RECESSED BASE-RAY may be recessed the depth of the lath and plaster, and will extend into the room approximately one and a quarter inches. EXPANSION BASE-RAY will expand about 1/8” in 10 lineal feet with a temperature rise of 180°F. To provide for this, holes cut through the Àoors should be larger than the pipe, and swing connections should be located in branches between the Main and Risers. VENTING When two or more BASE-RAY assemblies are connected in series on a hot water job it is necessary to vent each assembly, unless the assemblies are connected at the top tapping. When connected in series on a two-pipe steam job, the assemblies should be connected at the bottom, and only one steam air vent need be used. MAXIMUM DIMENSIONS OF FITTINGS Inasmuch as the BASEBOARD EXTENSION PANELS and PROJECTING CORNER PLATES are installed Àush with the face of BASE-RAY, there are a few types of ¿ttings that cannot be used in back of these parts because of the space limitations. As shown in the adjacent diagram, the diameter of the ¿ttings cannot exceed 1½” – radiator union elbows and regular pipe unions usually measure more, ¾” copper sweat or screw ¿ttings usually measure less. When iron pipe and ¿ttings are used, straight connections may be made with ¾” right and left coupling and corner connections with ¾” street elbow. Because of these space limitations, Burnham has available a No. 90-S Compression Connector for use with the Projecting Corner Plate (see illustration). Because of the radius on the face of INVERTED CORNER PLATE, ¿ttings having a diameter greater than 1½” may be used (see illustration). For easy and quick connections at inside corners, however, we recommend the Burnham No. 90-S Compression Connector for use with the 4-5/8” Inverted Corner Plate. Both are illustrated. VALVE ENCLOSURES have been designed to accommodate almost all makes of shut-off valves and steam traps. See Illustration for Enclosure dimensions. 8 INSTALLATION INSTRUCTIONS 1. Wall Preparation: To prevent excessive heat loss through the walls in back of BASE-RAY®, it is recommended that the stud space behind the Assemblies be insulated to a height of at least 12” above the Àoor with 4” mineral wool batts (blanket or loose insulation may also be used) or other approved insulating materials. This is particularly essential if the BASE-RAY is recessed. Mark Stud locations. 2. Allowance for Finished Flooring to Wall-to-Wall Carpeting: If BASE-RAY is to be installed prior to the ¿nished Àoor, a wooden strip 2½” in width and equal in height to the ¿nished Àoor should be installed along the base of all walls where baseboard assemblies and trim are to be placed. If allowance is not made for wall-to-wall carpeting, or for carpeting that is to be laid with edges Àush to the room side surface of BASE-RAY, the air inlet of the BASERAY will be restricted, resulting in a reduction in output. To compensate for the wall-to-wall carpeting, baseboard assemblies and trim should be raised by laying under them a strip of wood 2½” wide and the same thickness as the carpet and pad. 3. 4. Locate Holes for Piping (see Illustrations): Recessing of BASE-RAY Assemblies and Trim. (If BASE-RAY to be installed free-standing, proceed to Step 4.) BASE-RAY and Trim may be partially recessed or installed free standing against the ¿nished wall surface. Although procedure for preparing recess may vary slightly with type of ¿nished wall, in general, steps outlined below for lath and plaster construction may be followed: a. Nail ½” plaster ground to studs with the bottom of the plaster ground located 10” above ¿nished Àoor. * Additional height must be allowed if recess prepared before ¿nished Àoor is laid or if wall-towall carpeting is to be installed – see Step 2 of Installation Instructions. b. Line back of recess with paper-backed aluminum foil. This can be accomplished quickly and neatly by stapling foil to studs with staple gun. Foil surface should be on room side. 9 5. Assembling BASE-RAY® Press down on both cam handles simultaneously until castings are drawn together. Be sure clamp is not tilted, since this may break casting. If nipples do not draw up evenly during ¿nal tightening, strike end of assembly with wood block and hammer or mallet to bring the sections back in line. Do not strike BASE-RAY sections with metal hammer. BASE-RAY is shipped assembled in lengths up to six (6) lineal feet – longer assemblies are shipped in two or more sub-assemblies for assembly on the job (see BASE-RAY Assembly chart, page 4). One man can join tow subassemblies together in a matter of minutes providing he has a BASE-RAYAssembly Clamp (available at a nominal charge) and follows the recommended procedure. Remove the clamp, place the tie bolts in the bolt slots and tighten securely. In assembling BASE-RAY sub-assemblies on the job, the sections should be lined up, face down, on the Àoor or other Àat surface near the wall on which they are to be installed. Ends of section, nipple ports and nipples should be thoroughly cleaned with kerosene or gasoline and wiped dry with a clean cloth. Place a thin coating of nipple lubricant on nipples and insert into the nipple ports of one assembly without cocking. Engage nipples in nipple ports of second assembly and push sections together by hand as far as possible keeping ends of sections parallel. In order to secure necessary leverage with BASE-RAY Clamp, cut two pieces of 1¼” steel pipe 15” long and place them on the two cam handles. Insert BASE-RAY Clamp nose in the recesses in the BASE-RAY castings, being certain that the nose of the clamp is resting on the bottom of the recess – THIS IS IMPORTANT. If the clamp nose will not reach the bottom of the recess, exert light pressure downward on the cam handles until the two castings are PARTIALLY drawn together. Release the pressure on the handles and the clamp nose will then drop to the bottom of the recess. 10 6. Installation of BASE-RAY® Assemblies Install all ¿ttings in end of sections and all necessary vents while assemblies are still laying Àat on Àoor. Install bottom center supports prior to raising assemblies to upright position. Refer to table for number of supports required. They should be spaced evenly. L e ng th A s s e mb ly Numb e r o f To p a nd B o tto m C e nte r S up p o rts Re q ui re d 1 ½ to 1 4 ½ L i ne a l F e e t 1 1 5 to 2 1 ½ L i ne a l F e e t 2 2 2 to 2 8 ½ L i ne a l F e e t 3 Install the spring clip Bottom Center support by pushing it all the way up against the bottom of two ¿ns and next to the waterway of the section as illustrated below. Run the ¼” cap screw into the clip until head is not more than ¾” from the clip. Stand Assemblies upright, place in position and fasten to the walls with Top Center Supports using the number shown in the table above. Insert Top Center Supports in Air Outlet opening of Sections opposite studs (stud locations determined in step 1). Use wood screw furnished with Top Center Support and screw into stud until tight, the longer dimension of the top center support is in a vertical position when installed. Back off fraction of a turn to permit movement caused by expansion and contractions of sections. Adjust Bottom Center Supports by turning Cap Screws down until they begin to contact Àoor. Do not extend the Cap Screws any further. Connect assemblies to piping. Complete remainder of piping to boiler, ¿ll system with water and check for leaks. 7. Installation of Valve enclosures (furnished in right-hand and left-hand patterns). Remove knockout in end of Valve Enclosure if piping to run through Valve Enclosure. Bend tab on Valve Enclosure so that hole is on inside of Valve Enclosure facing wall. Place Valve Enclosure next to BASE-RAY® and fasten to BASE-RAY with ¼” thumb screw furnished. Insert screw furnished through tab on Valve Enclosure and fasten to wall. Set Valve Enclosure Cover in place. CARE MUST BE EXERCISED TO SEE THAT 30 PSI GAUGE PRESSURE IS NOT EXCEEDED. DO NOT PRESSURE TEST WITH AIR. 11 8. Installation of Corner Plates INVERTED CORNER PLATES – for inside corners – furnished in two types, 4-5/8” standard plate is used when Assemblies on adjoining walls extend to within 4-3/8” of the corner. If this distance is greater than 4-3/8” but less than 10-3/8”, the 10-5/8” plate is used. Extended Plate may be cut to desired length with hacksaw. Set Inverted Corner Plate in place overlapping the end of the adjoining BASE-RAY® Assemblies. Secure to Àoor with wood screws furnished. If installation is on tile with wood sub-Àooring, drill 1/2” holes in tile in line with holes in Corner Plate. Holes should not penetrate sub-Àooring. Substitute screws of same size as furnished but longer and secure Corner Plate to sub-Àooring. If installation is on masonry Àoor, drill 1/2” holes approximately 1” deep in Àoor in line with holes in Corner Plate. Drive slightly oversized wood plugs into holes and secure Corner Plate to plugs with wood screws furnished. 9. Installation of Baseboard Extension, Splice Plates, End Caps and Filler Pieces. BASEBOARD EXTENSION – Extension panels are furnished in six foot lengths but may be cut to desired lengths with hacksaw. Extensions are supported by hangers which are attached to studs (stud locations determined in Step 1) with two No. 10 x 1-1/2” wood screws. Screw hangers to studs so that there is a hanger located at the extreme ends of the Baseboard Extension and at two foot intervals along its length. If construction members are not suitably located, use Moly Screw anchors to secure Hangers to wall. Bottom of Hangers should rest on ¿nished Àoor unless BASE-RAY has been raised for wall-to-wall carpeting (see page 9). If such is the case, Hangers must be raised an equal amount. Install END CAPS on Extension (see succeeding paragraph), insert lip on top rear of Extension into slot at top of Hangers and snap channel on bottom of Extension under spacer arm on lower part of Hanger. SPLICE PLATES – used to make neat covering for joint where two Extension Panels butt together or where Extension Panel terminates at BASE-RAY. Plate hooks on bottom of Splice Plate over lip on bottom of Extension Panel and push top of Splice Plate toward wall until hooks on top of the Splice Plate snap into position behind the Extension or the BASE-RAY. When the Splice Plate is used to join an Extension Panel to BASERAY, bottom hook which overlaps BASE-RAY must be cut off. PROJECTING CORNER PLATE – for concealing pipe and ¿ttings at outside corners. See section on MAXIMUM DIMENSION OF FITTINGS, page 8. Assemblies on adjoining walls must extend to within 3” of corner. Set Projecting Corner Plate in place overlapping the ends of the adjoining BASE-RAY Assemblies. Secure with moulding (not furnished) at top and bottom. 12 END CAPS – available in both left-hand and right-hand patterns for ¿nishing off ends of Baseboard Extensions that terminate at doorways or at Valve Enclosures. They can be used where Extensions butt against BASE-RAY in preference to Splice Plate. Remove Knockout in end of End Cap if piping is to run in this direction. Slide over end of Extension Panel. ADJUSTABLE END CAPS & FILLER PIECES – Adjustable End Caps are available in both left-hand and right-hand patterns and are used in the same locations as the standard end caps except the 9” length of the adjustable end caps makes it possible to ¿ll in spaces of up to 7-1/2”. A knockout is also available in the ends for piping. Filler pieces are used where a 9” space or less exists between two sections of baseboard or between a section of baseboard and baseboard extension. To install adjustable end cap or ¿ller piece accessory, insert bolt thru hole in accessory and engage toggle as shown below. Place accessory against BASE-RAY® at same time pushing toggle thru air outlet of BASE-RAY. With accessory in ¿nal location, tighten bolt until accessory is secure. Use ¿nger to keep toggle in vertical position, as shown below. 10. Completing Installation – Important AIR-SEAL – It is necessary to prevent leakage of air between the walls and BASE-RAY®, since this will cause dirt streaks on the wall above the heating unit. This can be avoided by installing an “Air-Seal”. We recommended using 1” wide tape for this purpose, preferably with a thermal setting adhesive, available from Burnham at nominal charge. With the adhesive side down, press one-half of tape against the top of BASE-RAY and the other half against the wall as illustrated on page 9. WOOD MOULDING – For ¿nished installation, 3/4” quarter round or other wood moulding should be nailed to wall on top of BASE-RAY (over “Air-Seal”) and Trim and down side of Valve Enclosures. When Projecting Corner Plates are used, install wood moulding at base of Corner Plate to hold in place. An illustration showing the application of the moulding can be found on page 9. PAINTING – BASE-RAY and Trim are primed with a latex (water based) paint and must be top coated with a high grade oil or solvent based enamel to prevent rusting of the metals immediately after installation. Primer coated products should not be allowed to sweat as a result of high room humidity or cold water in system. The use of Àat wall paint is not recommended since it may chip or crack when applied to surfaces that are heated. Consult reputable paint dealer. PROPER LOCATION OF TOGGLE WHEN SECURING ACCESSORY TO BASE-RAY INSTALLATION OF BASE-RAY ADJUSTABLE END CAP & FILLER PIECE 13 SPECIAL APPLICATIONS BASE-RAY® INSTALLED ON THREE WALLS OF ROOM – When BASE-RAY is installed on three walls, expansion noises are sometimes created by the middle assembly when rigid piping is used to connect all three assemblies together. Flexibility can be gained by connecting two of the adjoining assemblies with a Àexible connector or swing joint such as illustrated. INSTALLATION WITH BURNHAM RADIANT OR SLENDERIZED RADIATORS – Since a BASE-RAY installation is made in much the same manner as any other radiator system, BURNHAM RADIANT OR SLENDERIZED RADIATORS may be used in a BASE-RAY Radiant Baseboard System. TWO-TIER INSTALLATION – Where wall space is limited, BASE-RAY may be installed in tiers. Both sections may be upright or lower section inverted as illustrated. Legs on end sections are cut off to enhance appearance. RATING CORRECTION FACTOR – If BASE-RAY is installed in tiers in accordance with the illustrations, each tier will have a rating of .91 times the rating shown in the Tables on pages 2 and 3. POSSIBLE PIPING ARRANGEMENTS TWO-TIER BASE-RAY FORCED CIRCULATION HOT WATER SYSTEMS 14 All Base-Ray® repair parts may be obtained through your local Burnham Wholesale Distributor. Should you require assistance in locating a Burnham Distributor in your area, or have questions regarding the availability of Burnham products or repair parts, please contact Burnham Customer Service at (717) 481-8400 or Fax (717) 481-8408. 15 Limited Warranty DUO-RAD®, DUO-RAD® II AND CAST IRON RADIATION Limited Warranty – Except as provided below with respect to products or parts not manufactured by U.S. Boiler Co., Inc. U.S. Boiler Co., Inc. warrants to the original owner at the original installation site that products manufactured by U.S. Boiler Co., Inc. comply, at the time of manufacture, with recognized Hydronics industry regulatory agency standards and requirements then in effect and will be free from defects in materials and workmanship for a period of one year after the date of installation. The remedy for breach of this warranty is expressly limited to the repair or replacement of any part found to be defective under conditions of normal use and does not extend to liability for incidental, special or consequential damages or losses such as loss of the use of the products, inconvenience, loss of time or labor expense involved in repairing or replacing alleged defective product. U.S. Boiler Co., Inc. shall have no responsibility for the performance of any product sold by it under conditions varying materially from those under which such product is usually tested under existing industry standards, nor for any damage to the product from abrasion, erosion, corrosion, deterioration or the like due to abnormal temperatures or the inÀuence of foreign matter or energy, nor for the design or operation of any system of which any such product may be made a part or for the suitability of any such product for any particular application. For products or parts not manufactured by U.S. Boiler Co., Inc., the warranty obligation of U.S. Boiler Co., Inc. shall, in all respects, conform and be limited to the warranty actually extended to U.S. Boiler Co., Inc. by its vendors. Warranty service can be obtained by contacting the original installer of the product and providing him with a detailed description of any apparent defect. If this procedure fails to result in satisfactory warranty service, the owner should notify U.S. Boiler Co., Inc., P.O. Box 3079, Lancaster, PA 17604. Transportation to a factory or other designated facility for repairs of any products or items alleged defective shall, in all events, be the responsibility and at the cost of the owner. Notwithstanding any of the above provision, (1) failures resulting from misuse, improper installation or lack of maintenance are not covered by this warranty, and (2) U.S. Boiler Co., Inc.’s liability under this warranty shall not exceed the selling price of the product found to be defective. Equipment furnished by the Buyer, either mounted or unmounted, and when contracted for by the Buyer to be installed or handled is not covered by this warranty. U.S. Boiler Co., Inc. does not assume any responsibility in connection with such equipment, operation, warranty, performance, or any other liability connected thereto. Then foregoing provisions of this WARRANTY shall be effective to the maximum extent permitted by applicable law, and, to the extent that any such provision would otherwise have an unconscionable result or would otherwise be inconsistent with applicable law, such provision shall be limited in effect to the minimum extent necessary to avoid such unconscionable result or inconsistency with applicable law. Any implied warranties, including implied warranties of merchantability and ¿tness for a particular purpose shall, to the extent permitted by applicable law, be limited in duration to a period of one year after the date of installation. To the extent permitted by applicable law, the remedies for breach of any such implied warranty shall be limited to the remedies set forth above with respect to a breach of the express limited warranty provided. With respect to the limitations on implied warranties set forth above, U.S. Boiler Co., Inc. hereby noti¿es each person to whom such warranty is made as follows: Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above limitations, or exclusions may not apply to you. This warranty gives you speci¿c legal rights, and you may also have other rights which vary from state to state. 03/03