PLC application models and Process simulators
Transcription
PLC application models and Process simulators
Table of Contents Table of Contents Automation Technology Automation technology Automation technology with Siemens PLC PLC application models and Process simulators CLC 34 PLC universal application simulator CLC 35 Process simulation PRO/TRAIN for Windows CLC 36 Closed-loop liquid level control/ flow-rate control CLC 37 PLC Touch Panel Models CLC 40.2 Elevator (lift) model Lucas Nülle GmbH Page 1/35 1 2 2 3 3 4 9 18 25 31 www.lucas-nuelle.com Automation Technology Acquire practical and project-oriented laboratory skills and expertise: Automation trainers, mechatronics trainers, PLC trainers Automation technology Automation technology Due to the growing importance of process automation the area of automation technology is taking on an ever greater role in industrial operations. This applies both for standard operations in production as well as for vocational training. Today automation technology almost always involves drive technology, closed-loop control and computer engineering. Due to the rapid developments in microcontroller and computer technology, automation has become one of the most innovative and breathtaking of all the areas of electrical engineering and electronics. Add to that the fact that novel industrial solutions like decentralisation and visualisation require new vocational training systems. Furthermore, the hitherto sheer multitude of manufacturer-dependent software products has been replaced by the international standard IEC1131-3. Contemporary programmable logic controls will now be programmed in accordance with standardised rules. All of these demands mean that there is a need to have the automation technician of today trained on practice-oriented training systems which convey to the student both the latest technology but also endow him or her with the required skills and competency. Lucas Nülle GmbH Page 2/35 www.lucas-nuelle.com Automation technology with Siemens PLC Automation technology with Siemens PLC PLC application models and Process simulators PLC application models and Process simulators The objective of PLC training is for the student to acquire practical hands-on skills. The prerequisite for this is systematic-didactic instruction in both form and content. This allows the necessary knowledge and skills to be conveyed in a practical, fast, effective and cost-efficient manner. The hands-on oriented experimentation and training using the process simulators and the process simulations are designed to meet these requirements. As such these training systems constitute the foundation for teaching not only the fundamentals but also advanced PLC programming. Lucas Nülle GmbH Page 3/35 www.lucas-nuelle.com CLC 34 PLC universal application simulator CLC 34 PLC universal application simulator The PLC universal system simulator was designed especially for PLC basic training. It is compact and constructed according to the motto "set up, switch on and train". It is exceptionally well-suited to graphically demonstrate open-loop and closed-loop industrial applications. By using the masks up to 24 different technical processes and models can be simulated. Lucas Nülle GmbH Page 4/35 www.lucas-nuelle.com Supplementary equipment set to the basic equipment set CLC 15/30: Supplementary equipment set to the basic equipment set CLC 15/30: Pos. Product name Bestell-Nr. 1 PLC universal application simulator Anz. CO3715-1A 1 Simply combine the universal PLC application simulator with any of the various PLC applications and circuits (analog and digital) to implement practical exercises with very little installation. The experiments are based on a standard syllabus. The application simulator is equipped with switches and pushbuttons as sensors as well as LEDs and an electronic circuit to simulate actuators. Process feedback signals (e.g. feedback signals from the contactors) are generated automatically. To simulate movements, levels and positions there are 3 running lights integrated into the device. The individual experiments are ready to perform after the overlay masks are fitted. 8 digital inputs (actuators) 20 digital outputs (sensors) 2 analog inputs (actuators) 2 analog outputs (sensors) 3 running lights Connections realised on 4mm safety sockets 1 37-pin sub-D male connector (input signals) for the connection to PLC via system connector 1 37-pin sub-D socket (output signals) for connection to the PLC via the system connector Operating voltage: DC 24V/0.3A Size: 456 x 297 x 125mm (WxHxD) Weight: 1 kg Lucas Nülle GmbH Page 5/35 www.lucas-nuelle.com 2 Set of 12 overlay masks for PLC universal application simulator I CO3715-1B 1 CO3715-1C 1 Basic set of overlay masks for the PLC Universal Application Simulator. The basic set consists of 12 different overlay masks with process and application models. Construction caution light Star-delta starting Dahlander circuit Starter control Monitoring device Reservoir - filling system Gate control of a lock Re-rooting platform Buffer storage Filling level controlled system Mixer system Compressed air network 3 Set of 12 overlay masks for PLC universal application simulator II The supplementary set of overlay masks for the PLC universal application simulator. The supplementary set comprises 12 different overlay masks with process and application models. Cleaning bath Oven door control Bending tool Stamping machine / automatic Drilling mechanism Selective distributor Tube bending plant Gate control Pump control 1 Pump control 2 Reaction chamber Automatic tablet packer Lucas Nülle GmbH Page 6/35 www.lucas-nuelle.com Media: Pos. Product name 4 Interactive Lab Assistant: CLC 34 Universal application simulator Bestell-Nr. Anz. SO2800-4J 1 The experiment instructions take the form of an Interactive Lab Assistant course. This multimedia course guides students step by step through the topic of PLC programming. 24 Projects are included: Construction site traffic lights Star-delta starter Dahlander circuit Starter control Monitoring facility Container filling plant Control of a lock gate Transfer platform Buffer memory Filling level control loop Mixing plant Compressed air network Cleaning tank Kiln door control Bending tool Embossing machine Drill Selective belt turnout Tube bending plant Gate control Pump control 1 Pump control 2 Reaction vessel Tablet bottling machine Features: Interactive experiment set-up Questions with feedback and evaluation logic for progress monitoring Printable document for simple printing out of instructions and solutions CD-ROM with Labsoft browser, course software and TIA Portal project Mininimum requirements: SIMATIC Manager version 5.5 or TIA Portal version 13 SP1 For Allen Bradley programming: RSLogix 5000 Lucas Nülle GmbH Page 7/35 www.lucas-nuelle.com Accessories: Pos. Product name Bestell-Nr. 5 Set of connection cables for PLC system connector Anz. SO5145-5B 1 SO5126-8A 1 CO3713-7G 1 For the connection of PLC process models or simulations to the PLC system connector, consisting of: 2 x connection cable Sub-D 37 pole 2 x safety protected connection plug, red 1 x safety protected connection plug, blue 6 Safety measurement cable (4mm), 25cm/10", red Safety measurement lead with stackable, contact-proof 4mm plugs colour: red length: 25 cm cable cross-section 2,5 mm2 ratings deliver: 600V CAT II, 32A 7 System connector module for PLC System connector module to extend the basic unit for SIMATIC S7300 controls for the simple connection of process models without having to carry out extensive wiring of the individual lines. 1 37-pin sub-D male connector (input signals) 1 37 pin sub-D socket (output signals) Dimensions: 125 x 65 x 25mm (HxWxD) Lucas Nülle GmbH Page 8/35 www.lucas-nuelle.com CLC 35 Process simulation PRO/TRAIN for Windows CLC 35 Process simulation PRO/TRAIN for Windows Effecient and didactically sensible training on the highly complex production systems found in industry is only feasible to some extent in automation technology. Thus training systems must be used which graphically demonstrate system interdependencies and that can be explored by the student without directly affecting the production process. PRO/TRAIN for Windows is a training system which allows various automated processes to be depicted and simulated at a work station for practical hands-on experimentation. The training system consists of software, hardware and teachware. The software simulates and graphically depicts typical, technological processes, machines and drives on a PC. The software models are graphically detailed and realistically depicted both in terms of design as well as operating response. For each model there is the possibility of performing process analysis in demonstration mode. Malfunctions are realistically simulated in the process simulations for practical experience and can be initiated randomly or simulated by the user using the keyboard. Control errors are identified and logged by the software. The switches and pushbuttons needed to operate the models are already integrated into the respective simulations. The use of real hardware for operation and monitoring, e.g. an Operator Panel, is easily integratable. The I/O interface connects the PC via the serial interface using the signal inputs and outputs of a PLC control unit. As such process models with digital actuators and sensors as well as analog final control elements and signal generators can be connected and controlled. The actuators incorporated in the model can be controlled directly by the PLC and the switching states of the signal generators are transmitted to the PLC. The signal level for connection to the PLC has been selected so that any given industrial-type PLC can be connected to the interface. The input and output signals of the process are accessible on the interface and can be checked by means of electronic measurement. Each model package has an in-depth, state-of-the-art online help using browser technology. These contain general descriptions of the simulation models, control exercises as well as sample PLC programs. The control programs are generally applicable system function charts documented in accordance with the IEC-1131 standard. The input and output signals are outlined in the statement lists and IQF reference lists. This guarantees simple translation into the respective programming language. Lucas Nülle GmbH Page 9/35 www.lucas-nuelle.com Supplementary equipment set to the basic equipment set CLC 15/30: Supplementary equipment set to the basic equipment set CLC 15/30: Pos. Product name Bestell-Nr. 8 I/O-Interface for PRO/TRAIN for Windows Anz. CO3715-1H 1 PC interface to couple process simulation software and any given type of PLC with industrial-type signal levels. All inputs and outputs are arranged on 4mm safety sockets and are parallel to two 37-pin system connectors. The status of the digital inputs and outputs is indicated via LEDs. Connected to PC via the serial interface. 16 digital inputs, 24V DC 16 digital outputs, 24V DC 2 analog inputs, 0-10V resolution 11Bit 4 analog outputs, 0-10V resolution 11Bit Voltage supply: 24V, 1A Dimensions: 297 x 227 x 60mm (HxWxD) Weight: 1kg Lucas Nülle GmbH Page 10/35 www.lucas-nuelle.com Software: Software for creating your own process models: Pos. Product name Bestell-Nr. 9 Software PRO/TRAIN für Windows Pneumatik (D) Anz. SO6001-6C 1 In diesem Trainingspaket werden technologische Prozesse aus dem Bereich der Elektropneumatik modelliert. Mit den Modellen können steuerungstechnische Aufgabenstellungen zur Steuerung von pneumatischen Anlagen und Antrieben, zur Störungsüberwachung und -meldung realisiert werden. Alle Sensoren und Aktoren, die zur Steuerung des Prozesses benötigt werden, sind im Prozessmodell integriert. In den Modellen werden in den unterschiedlichen Bewegungssituationen die jeweiligen Druckverhältnisse sichtbar gemacht. Das Paket umfasst zwei Prozessmodelle: Grundschaltungen: Das Prozessmodell umfasst alle notwendigen Elemente einer Pneumatikanlage von der Druckerzeugerstation bis zu den verschiedenen Pneumatikzylindern. Die Steuerung der verschiedenen pneumatischen Antriebe erfolgt über elektromagnetische Wegeventile. Zum Betrieb werden folgende Signale auf der SPS benötigt: 15 digitale Eingänge 11 digitale Ausgänge Bohrvorrichtung: Mit der Bohrvorrichtung sollen Werkstücke automatisch gebohrt werden. Dazu werden die Werkstücke aus einem Magazin vereinzelt und auf einen Bohrtisch transportiert, automatisch gebohrt und wieder ausgeworfen. Die Steuerung der elektropneumatischen Antriebe erfolgt in diesem Prozessmodell über elektromagnetische Wegeventile. Zum Betrieb werden folgende Signale auf der SPS benötigt: 13 digitale Eingänge 10 digitale Ausgänge In den beiden Prozessmodellen ist jeweils ein Bedienpanel mit allen zur Bedienung der Anlage erforderlichen Taster, Schalter und Meldeleuchten integriert. Zur Fehlersuche können verschiedene Störungen wie defekte Sensoren und blockierte Zylinder simuliert werden. Zu jedem Modell wird eine Auflagemaske zum I/O-Interface mit Kennzeichnung der Ein- und Ausgangssignale mitgeliefert. Lucas Nülle GmbH Page 11/35 www.lucas-nuelle.com 10 Software PRO/TRAIN für Windows Hydraulik (D) SO6001-6E 1 In diesem Trainingspaket werden technologische Prozesse aus dem Bereich der Elektrohydraulik modelliert. Mit diesen Modellen können steuerungstechnische Aufgabenstellungen zur Steuerung von hydraulischen Antrieben, zur Störungsüberwachung und meldung realisiert werden. Alle Sensoren und Aktoren, die zur Steuerung des Prozesses benötigt werden, sind im Prozessmodell integriert. Das Paket umfasst zwei Prozessmodelle: Hydraulikantriebe: Das Prozessmodell umfasst verschiedene Hydraulikantriebe, die über elektromagnetische Wegeventile gesteuert werden. Zum Betrieb werden folgende Signale auf der SPS folgende benötigt: 13 digitale Eingänge 9 digitale Ausgänge Stellantrieb: Das Prozessmodell umfasst alle notwendigen Elemente einer Hydraulikanlage zur Realisierung eines hydraulischen Stellantriebes. Die Steuerung des Antriebes erfolgt über ein elektromagnetisches Wegeventil. Zum Betrieb werden folgende Signale auf der SPS folgende benötigt: 10 digitale Eingänge 8 digitale Ausgänge In den beiden Prozessmodellen ist jeweils ein Bedienpanel mit allen zur Bedienung der Anlage erforderlichen Taster, Schalter und Meldeleuchten integriert. Zur Fehlersuche können verschiedene Störungen wie zum Beispiel defekte Sensoren, blockierte Zylinder sowie das Auslösen des Temperaturkontaktes simuliert werden. Zu jedem Modell wird eine Auflagemaske zum I/O-Interface mit Kennzeichnung der Ein- und Ausgangssignale mitgeliefert. Lucas Nülle GmbH Page 12/35 www.lucas-nuelle.com 11 Software PRO/TRAIN für Windows Elektrische Maschinen (D) SO6001-6G 1 In diesem Trainingspaket werden technologische Prozesse aus dem Bereich der Elektrischen Maschinen modelliert. Mit diesen Modellen können steuerungstechnische Aufgabenstellungen zum Schalten, Schützen und Überwachen der Antriebe realisiert werden. Alle Sensoren und Aktoren, die zur Steuerung des Prozesses benötigt werden, sind im Prozessmodell integriert. . Die Schaltgeräte sind mit Hilfskontakten ausgestattet, über die der SPS, die aktuelle Schaltstellung mitgeteilt wird. Zur Anzeige der aktuellen Drehzahl der Maschine ist eine Digitalanzeige vorhanden. Das Paket umfasst drei Prozessmodelle: Wendeschützschaltung: Das Prozessmodell umfasst die Elektroanlage zum Schalten einer Drehstrom-Asynchronmaschine mit zwei Drehrichtungen. Zum Betrieb werden folgende Signale auf der SPS benötigt: 6 digitale Eingänge 5 digitale Ausgänge Stern-Dreieck Anlasserschaltung: Das Prozessmodell umfasst die Elektroanlage zum Schalten einer Drehstrom-Asynchronmaschine mit Stern-Dreieck Anlasserschaltung für eine Drehrichtung. Zum Betrieb werden folgende Signale auf der SPS benötigt: 6 digitale Eingänge 5 digitale Ausgänge Frequenzumrichter: Das Prozessmodell umfasst die Elektroanlage zum Betrieb einer Drehstrom-Asynchronmaschine an einem Frequenzumrichter. Der Frequenzumrichter verfügt dazu über industrietypische Steuereinund –ausgänge. Zum Betrieb werden folgende Signale auf der SPS benötigt: 7 digitale Eingänge 7 digitale Ausgänge 2 analoge Eingänge 0 - 10V 1 analoger Ausgang 0 - 10V In allen drei Prozessmodellen ist jeweils ein Bedienpanel mit allen zur Bedienung der Anlage erforderlichen Taster, Schalter und Meldeleuchten integriert. Zur Fehlersuche können verschiedene Störungen wie zum Beispiel: Auslösen des Leitungsschutzschalters, Kontakte eines Schützes sind festgeklebt, Leistungsschütz zieht nicht mehr an, Störung Frequenzumrichter sowie Auslösen eines Motorschutzschalters simuliert werden. Zu jedem Modell wird eine Auflagemaske zum I/O-Interface mit Kennzeichnung der Ein- und Ausgangssignale mitgeliefert. Lucas Nülle GmbH Page 13/35 www.lucas-nuelle.com 12 Software PRO/TRAIN für Windows Fertigungstechnik (D) SO6001-6J 1 In diesem Trainingspaket werden technologische Prozesse aus dem Bereich der Fertigungstechnik modelliert. Mit diesen Modellen können steuerungstechnische Aufgabenstellungen für Ablauf- und Folgesteuerungen, zur Störungsüberwachung und -meldung realisiert werden. Das Paket umfaßt zwei Prozeßmodelle: Abfüllanlage: In dieser Abfüllanlage soll eine einstellbare Anzahl von Produkten in die auf dem Laufband ankommenden Behälter abgefüllt werden. Mit Hilfe von Sensoren werden die leeren Behälter auf Beschädigung überprüft und gegebenenfalls entfernt. Die unbeschädigten Behälter laufen weiter zur Abfüllanlage und werden dort mit einer vorgegeben Anzahl von Produkten befüllt und danach mit einem Deckel verschlossen. Alle Sensoren und Aktoren, die zur Steuerung des Prozesses benötigt werden, sind im Prozessmodell integriert. Dazu werden auf der SPS folgende Signale benötigt: 16 digitale Eingänge 9 digitale Ausgänge Sortieranlage: Mit der Sortieranlage sollen ankommende Pakete mit Hilfe von Sensoren ihrer Größe entsprechend auf drei Laufbänder verteilt werden. Alle Sensoren und Aktoren, die zur Steuerung des Prozesses benötigt werden, sind im Prozessmodell integriert. Dazu werden auf der SPS folgende Signale benötigt: 14 digitale Eingänge 16 digitale Ausgänge In den beiden Prozessmodellen ist jeweils ein Bedienpanel mit allen zur Bedienung der Anlage erforderlichen Taster, Schalter und Meldeleuchten integriert. Zur Fehlersuche können verschiedene Störungen wie zum Beispiel defekte Sensoren sowie das Auslösen von Motorschutzschaltern simuliert werden. Zu jedem Modell wird eine Auflagemaske zum I/O-Interface mit Kennzeichnung der Einund Ausgangssignale mitgeliefert. Lucas Nülle GmbH Page 14/35 www.lucas-nuelle.com 13 Software PRO/TRAIN für Windows Verfahrenstechnik (D) SO6001-6L 1 SO6001-6S 1 In diesem Trainingspaket werden technologische Prozesse aus dem Bereich der Verfahrenstechnik modelliert. Mit diesen Modellen können steuerungstechnische Aufgabenstellungen für Ablaufsteuerungen und Folgesteuerungen, zur Störungsüberwachung und -meldung realisiert werden. Alle Sensoren und Aktoren, die zur Steuerung des Prozesses benötigt werden, sind im Prozessmodell integriert. Das Paket umfaßt zwei Prozeßmodelle: Pumpenanlage: Ein Wasserbehälter wird als Speicherbecken für Schmutzwasser mit diskontinuierlichem Zulauf genutzt. Mittels zweier Pumpen wird das Schmutzwasser aus dem Speicherbecken abgepumpt. Die Steuerungsaufgabe liegt darin, das Flüssigkeitsniveau im Speicherbecken in gewissen Grenzen zu halten. Dazu werden auf der SPS folgende Signale benötigt: 14 digitale Eingänge 7 digitale Ausgänge Mischanlage: In einer Mischanlage sollen zwei verschiedene Flüssigkeiten nach einem einstellbaren Mischungsverhältnis in einem Tankbehälter gemischt werden. Zur besseren Reaktion der beiden Stoffe wird das Flüssigkeitsgemisch mit einem Rührer vermischt und über eine Heizung auf eine bestimmte Temperatur aufgeheizt. Dazu werden auf der SPS folgende Signale benötigt: 16 digitale Eingänge 13 digitale Ausgänge 3 analoge Eingänge 0 - 10V 2 analoge Ausgänge 0 - 10V In den beiden Prozessmodellen ist jeweils ein Bedienpanel mit allen zur Bedienung der Anlage erforderlichen Taster, Schalter und Meldeleuchten integriert. Zur Fehlersuche können verschiedene Störungen wie zum Beispiel defekte Sensoren und Antriebe sowie das Ansprechen der Motorschutzschalter simuliert werden. 14 Software PRO/TRAIN für Windows Entwicklungssoftware (D) Entwicklungssoftware zur Erstellung eigener Prozesssimulationen zum Ausbildungssystem PRO/TRAIN für Windows. Die Entwicklungssoftware erlaubt die komfortable Erstellung einfacher bis komplexer Prozessvisualisierungen, Animationen ohne jegliche Programmierung. Einfach zu handhabende, grafische WINDOWSBenutzeroberfläche Umfangreiche Bibliothek von Systemblöcken aus den Bereichen Signalgeneratoren, lineare und nichtlineare Übertragunsglieder, zeitdiskrete Systeme, Statistik, Digitaltechnik, virtuelle Instrumente Lucas Nülle GmbH Page 15/35 www.lucas-nuelle.com Zusammenfassen von Teilsystemen zu wiederverwendbaren Modulen Systemblöcke zur Anbindung des I/O-Interface Folgende Elemente stehen zur Visualisierung und Animation zur Verfügung: Linien und Polylinien Kreise, Ellipsen, Rechtecke, Dreiecke und Parallelogramme y-t- und x-y-Grafiken Mehrspaltige Tabellen Bitmaps und Windows-Metafiles Bitmap-Statusanzeigen und Bitmap-Sequenzen (animierte Bitmaps) Video für Windows-Dateien (AVI-Dateien) Sound-Unterstützung (WAV-Dateien) Statische Texte und Textmeldungen Zeit- und Datumsfelder Numerische Ausgabefelder Horizontale und vertikale Balkenanzeigen, Ablaufanzeigen, Thermometer LED-Anzeigen und LCD-Panels Analoginstrumente (skalierbar) Schalter und Taster sowie Bitmap-Schaltflächen und Schaltergruppen Schaltflächen mit Sonderfunktionen (z. B. zur Simulationssteuerung) Editierfelder Schaltfelder (Checkboxen) Horizontale und vertikale Schieberegler Horizontale und vertikale Leitungen (animiert) Tanksysteme (animiert) Ventile, Hydraulikzylinder, Pumpen und Motoren (animiert) Betriebssystem: PRO/TRAIN ist unter allen Windowsversionen lauffähig Lucas Nülle GmbH Page 16/35 www.lucas-nuelle.com Accessories: Pos. Product name Bestell-Nr. 15 Serial interface cable 9/9 pole Anz. LM9040 1 SO5145-5B 1 CO3713-7G 1 9-pin SUB-D cable Length: 2m Connector: 9-pin plug/9-pin socket Pin assignment: 1:1 16 Set of connection cables for PLC system connector For the connection of PLC process models or simulations to the PLC system connector, consisting of: 2 x connection cable Sub-D 37 pole 2 x safety protected connection plug, red 1 x safety protected connection plug, blue 17 System connector module for PLC System connector module to extend the basic unit for SIMATIC S7300 controls for the simple connection of process models without having to carry out extensive wiring of the individual lines. 1 37-pin sub-D male connector (input signals) 1 37 pin sub-D socket (output signals) Dimensions: 125 x 65 x 25mm (HxWxD) Lucas Nülle GmbH Page 17/35 www.lucas-nuelle.com Additionally recommended Pos. Product name Bestell-Nr. 18 USB-RS232 interface adapter with 9-pin SUB-D plug Anz. LM9062 1 USB-RS232 interfaceadapter with 9-pin SUB-D plug CLC 36 Closed-loop liquid level control/ flow-rate control Lucas Nülle GmbH Page 18/35 www.lucas-nuelle.com CLC 36 Closed-loop liquid level control/ flow-rate control "Closed-loop liquid level control" is a practice-oriented experiment set in applied control technology designed especially for didactic purposes. Due to immediate, visible nature of the controlled variable, i.e. "the level of the liquid", liquid level control is an extremely graphic experiment and is thus particularly well suited for an introduction into automatic control technology. The controlled system or liquid level basin is characterised by the fact that it has a medium response time. Thus experiments can be performed rapidly and the student can simultaneously monitor how the experiment is proceeding. The experiments focus on determining the most important parameters of controlled systems with compensation and the set-up and optimisation of control loops with continuous and discontinuous controllers. The liquid level basin has a plain form on which the foils can be attached to facilitate the marking of the liquid level as a function of time. The character of the controlled system can be modified by using various sliding partitions (delays of the 1st and 2nd order). 4 different outlet drains can be set on the filling basin and the inlet can be set as desired either using an ascending pipe or versus the filling pressure. Because of its modular design, the training system can, with the corresponding supplements, also be used for automatic flow-rate control and to explore measuring techniques. Automatic liquid-level control Set-up, putting into operation and optimising an automatic liquid-level control with variable controlled system characteristics Two-position controller in an integral-action controlled system of a higher order Two-position controller with delayed feedback in a closed-loop liquid level control system Two-position controller with float switch PI and PID controller in a closed-loop control system of the first and higher orders Automatic liquid level control with disturbance variable forward feed and precontrol Automatic flow-rate control Set-up, putting into operation and optimising an automatic flow-rate control with variable controlled system characteristics Operating principle, response and application of flow-rate measurement Investigating automatic flow-rate control with PI or PID controller and system response to disturbance and reference variable step changes Operating principle and use of step controllers and closed-loop flow-rate control with step controllers Lucas Nülle GmbH Page 19/35 www.lucas-nuelle.com Supplementary equipment set to the basic equipment set CLC 15/30: Supplementary equipment set to the basic equipment set CLC 15/30: Pos. Product name Bestell-Nr. Anz. 19 Compact level control kit including vessel, tank, pump and sensors CO3620-1H 1 The filling level measurement training system is for experiments in automatic control technology that are both educational and based on practice. Liquid level and flow can both be measured with one instrument. Since the controlled variable, the height of liquid in the vessel is clearly visible, it makes the experiment easy to observe and makes for a good introduction to automatic control technology. The compact educational apparatus includes the vessel to be filled, a pressure transducer to determine the current filling height and a separate reservoir and pump. So that the pump achieves constant pumping power, a secondary control loop with a flow rate meter which can shut off the system as necessary is integrated into the set-up. Disturbance variables can be simulated by means of adjustable throttle valves that alter the flow rate to and from the vessel. Quick-release plugs are available for connecting an optional second vessel in order to create a second order controlled system. Secondary flow-rate control loop Integrated power amplifier Transparent vessel for observing the height of liquid A second vessel can be connected via quick-release plugs to make a second order control system. Disturbance variables can be simulated by means of adjustable throttle valves Measurement site for pressure sensor in the vessel Pressure sensor to measure height of liquid complete with immersible tube Output voltage: 0 - 10V Calibration of zero point and gain Additional emergency overflow outlet Reservoir for liquid Operating voltage: +/-15VDC Nominal current: 1.2A Dimensions: 297 x 456 x 160mm (HxWxD) Weight: 3.0kg Lucas Nülle GmbH Page 20/35 www.lucas-nuelle.com Media: Pos. Product name Bestell-Nr. 20 Manual IAC 10/11, Level and flow control kit with digital controller SH5003-6A Anz. 1 High-quality, bound, colour teachers’ manual with rigid spine, including solutions. CD-ROM with additional students’ manual, including exercises and worksheets. Details: Theoretical background Colour CAD drawings for experiment set-ups and circuits Exercises and worksheets Printed on high-quality 100-g/m² colour copy paper, book cover on 210-g/m² glossy paper Training contents: Automatic liquid-level control Set-up, operation and optimisation of an automatic liquidlevel control with variable controlled system characteristics PI and PID controller in a closed-loop control system of the first and higher orders Automatic flow-rate control Set-up, operation and optimisation of an automatic flow-rate control with variable controlled system characteristics Operating principle, response and application of flow-rate measurement Investigating automatic flow-rate control with PI or PID controller and system response to disturbance and reference variable step changes Lucas Nülle GmbH Page 21/35 www.lucas-nuelle.com Power supply: Pos. Product name Bestell-Nr. 21 DC Power supply, ±15V/6A Anz. CO3538-8A 1 Stabilized power supply Output: +/-15V/6A, electrically isolated from the mains, continuously protected against short-circuit Dimensions: 297 x 114 x 145mm (HxWxD) Lucas Nülle GmbH Page 22/35 www.lucas-nuelle.com Measuring instruments: Pos. Product name Bestell-Nr. 22 Multi13S digital multimeter Anz. LM2330 1 Universal precision lab multimeter and temperature meter with IR interface for high-quality, universal measurement and testing in educational settings, power plants, process control installations etc. 3¾-digit multimeter; resolution: ±3,100 digits Measurement classification CATII-1000V Can be connected to UniTrain system via IR interface Voltage and current measuring ranges: 30mV-1000V DC, 3V-1000V AC; 3mA-16A DC; 30mA-10A AC Resistance ranges: 30ohm-30Mohm Special functions: for temperature measurements using PT100/1000 thermocouple (optional accessory) Continuity and diode testing Automatic range selection and battery shut-off, min./max. and data hold function Safety fuse for current measurement range up to 300mA Protection against high currents in the mA range for nominal voltage of 1000V Display with bar chart and backlighting Includes protective sleeve, measuring leads, 1 x spare fuse, 9V battery, calibration certificate Accessories: Pos. Product name Bestell-Nr. 23 Safety connecting plug 4mm with tap (2x), red, 1000V/32A CAT II Anz. SO5126-3U 1 Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour red Lucas Nülle GmbH Page 23/35 www.lucas-nuelle.com 24 Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II SO5126-3V 2 SO5126-3R 3 SO5148-2A 1 Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour blue 25 Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour black 26 Set of safety measurement cables 4mm (30pcs) This set consists of: 10 safety connection leads, 4mm, 25cm, black 10 safety connection leads, 4mm, 50cm, black 2 safety connection leads, 4mm, 100cm, red 6 safety connection leads, 4mm, 100cm, black 2 safety connection leads, 4mm, 100cm, blue Lucas Nülle GmbH Page 24/35 www.lucas-nuelle.com CLC 37 PLC Touch Panel Models CLC 37 PLC Touch Panel Models The touch panel models provide a system with which students can swiftly master an introduction to TIA (Totally Integrated Automation) portals. The models are designed to cover all the basic functionality of PLC programming. All the topics are included, from programming of data blocks, state machine and sequential programming, right up to the design of controllers. The animated illustration of the models simplifies understanding of how the models respond to programming. What was previously indicated by means of flashing LEDs or by additional software can now be replaced by a compact system. By activating the PLC system’s digital outputs, the models can be manually controlled without difficulty, so that students can investigate precisely how they function. Lucas Nülle GmbH Page 25/35 www.lucas-nuelle.com Equipment set comprising the following: Pos. Product name Bestell-Nr. 27 Interactive Lab Assistant: CLC 37 PLC Touch Panel Models Anz. SO2800-4M 1 Instructions are provided in the form of an Interactive Lab Assistant course. This multimedia course goes step-by-step through the topic of PLC programming. Students are introduced in steps to PLC programming, from the simple operation of a conveyor belt on to complex sequence control systems. The projects are made simple to understand thanks to graphic illustrations and animations. The models are shown in animated form on a touch panel and are controlled via the digital I/O of the PLC system to which they are connected. As for genuine models, it is possible to receive the signals from sensors which can then be used for processing in a step sequence. The models are already full programmed as supplied. Projects included: Transport crane (step sequence programming for advanced students) Road works traffics lights (animated vehicles respond automatically to the state of the traffic lights) Container filling plant (process automation of a system with three tanks) Conveyor belt (introduction to step sequence programming with plenty of exercises) Three-storey lift (state machine and step sequence programming) Star-delta starting circuit (timer programming) Dual 7-segment display (programming of data blocks) Automatic room temperature control (use of a closed-loop control module) Special features: Questions with feedback and evaluation software for assessment of knowledge Printable document so that the experiment instructions and solutions can be printed out easily 4 MB memory card for programming the PLC system CD-ROM with Labsoft browser, course software and TIA portal project Benefits to you: Compact system (PLC, touch panel and models, all in a single piece of equipment) Programming via TIA (Totally Integrated Automation) portal Programming and observation on one screen. Alternative software solutions require a separate screen Introduction to programming via TIA portal with the help of animated models Minimum requirements: TIA-Portal V13 SP1 Lucas Nülle GmbH Page 26/35 www.lucas-nuelle.com 28 SIMATIC S7-1200 14 DI, 10 DO, 2 AI, 1 AO, 24V / 5 A power supply CO3713-8Q 1 Modular training system for PLC devices in the SIMATIC S7-1200 range. Profile rails are fully accessible and can accommodate a PROFIBUS or an AS-i master module. KTP700 touch panel includes an Ethernet port for communication and programming. S7-1200 PLC: SIMATIC S7-1200 with 1214C DC/DC/DC CPU Tough console housing with non-slip feet Integrated power supply: 24 V/5 A DC Sockets for emergency shut-down loop (to cut off voltage to output terminals) Working memory: 50 kilobytes Upload memory: 2-Mbyte Programming language: STEP 7 as of version 10.5 Processing times: 0.1 μs for bit operations, 12 μs for word operations, 18 μs for floating point arithmetic Total remanent data memory (including timers, counters and flags): 2048 bytes 1 Ethernet/ProfiNet port Integrated inputs and outputs 14 Digital inputs, 24 V DC, via 4-mm safety sockets 14 Latching push buttons for simulating digital inputs 2 Analog inputs, 0…10 V, via 4-mm safety sockets 1 Potentiometer for simulating analog input 10 Digital outputs, 24 V DC, via 4-mm safety sockets 1 Analog output, 0..10V, via 4-mm safety sockets 1 x 9-pin Sub-D socket for connection to mechatronics systems 1 x 9-pin Sub-D socket for connection to mechatronics systems Real-time clock KTP700 touch panel: Fully graphical colour display (65536 colours) MTBF backlighting 7" touch screen Resolution: 800 x 480 W x H Port: PROFINET Operating voltage: 100-240V AC, 50-60Hz Dimensions (HxWxD): 297 x 456 x 125 mm Weight: 7 kg Ethernet switch: All equipment can be easily combined in a network via the integrated four-way Ethernet switch. Important note: Items may only be ordered upon proof of a supplementary licensing agreement for schools and training centres (including Lucas Nülle GmbH Page 27/35 www.lucas-nuelle.com commercial training facilities). Software: Pos. Product name Bestell-Nr. 29 Software for training systems 1x STEP 7, S7-Graph, S7-SCL, PLCSim(D,GB,F,E,I) Anz. SO6002-1Q 1 The software consists of the following program elements: 1 x STEP 7 Professional V14 (TIA-Portal) 1 x STEP 7 Professional 2010 v5.5 For designing projects with SIMATIC S7-1500/1200/300/400/WINAC and SIMATIC Basic panels. 1 x S7-SCL (Structured Control Language); pascal-type high-level language, optimised for the programming of programmable logic controls 1 x S7-GRAPH; efficient tool for the description of sequential processes (process chains) including a methodical procedure and display offering a clear overview. 1 x S7-PLCSIM; simulation software for testing user programs created on a PC, independent of the availability of targeted hardware. 1 x S7 Distributed Safety v5.4 Warning: Suitable for schools and commercial training centres. System prerequisites: Personal computer with Windows Server 2003/Windows 7 operating system (32 Bit Ultimate, Professional and Enterprise) CD-ROM disk drive for software installation USB port for programmer interface Minimum 650 MB free hard disk memory Minimum 1GB RAM main memory Processor with min. 600 MHz for Windows XP, 2.4 GHz for Windows Server 2003 and 1 GHz for Windows 7 Lucas Nülle GmbH Page 28/35 www.lucas-nuelle.com Media: Pos. Product name 30 QuickChart Siemens SPS S7-1200 Board (D) Bestell-Nr. Anz. SO6200-5J 1 Bestell-Nr. Anz. ST7200-3A 1 Short documentation covering the putting into operation of complex equipment and experiment set-ups. Terminal assignment, safety instructions, help Circuit and assembly diagrams Color print in DIN A3 format Laminated: 2 x 250 µm Accessories: Pos. Product name 31 Mobile aluminium experiment stand, 3 levels, power strip with 6 sockets, 1250x700x1995mm High-quality, mobile experiments stand from the SybaPro range for demonstrations and experiments. Features aluminium profile legs compatible with all add-ons and extensions for the SybaPro system. The mobile experiment stand is supplied in kit form and needs to be assembled by customers themselves. Table top: 30-mm table top made of highly compressed, multi-layer fine chipboard conforming to DIN EN 438-1 Colour grey, RAL 7035, with 0.8-mm slightly textured laminate coating (Resopal) on both sides, conforming to DIN 16926 Resistant to many chemicals and reagents including dilute acids and alkalis Resistant to heat, e.g. molten solder or heating at specific points such as by soldering tips or cigarette ends Table top with solid impact-resistant protective edging made of 3mm thick RAL 7047 coloured plastic Coating and adhesive are PVC free Lucas Nülle GmbH Page 29/35 www.lucas-nuelle.com Power strip with 6 outlet sockets mounted underneath the table top, lead and earthed plug Frame: 2 extruded aluminium profiles with multiple grooves 1800 x 120 x 40 mm (WxHxD) 8 equally sized grooves in extruded aluminium profiles (3 on each side and 1 each on the front and back) Grooves accommodate standard industrial mountings 4 H-shaped aluminium profiles, 1150 mm, for 3-layer organisation of DIN A4 panels Space for extension of power supply duct Base made of rectangular tubing with 4 swiveling double casters, 2 of which have brakes Table frame made of tough combination of rectangular tubing around the full perimeter Acid-resistant epoxy-resin coating, 80 µm thick (approx.), colour RAL 7047 Dimensions: Height of table top 760 mm 1250 x 1995 x 700 mm (WxHxD) 32 Protection cover for three-level experiment trolleys ST8010-9Y 1 Dust cover for three-level experiment trolleys For protecting equipment from dust and damp For keeping equipment out of sight (the cover must not be transparent, so is therefore opaque) Colour: matt dark grey with printed LN logo in orange) Material: nylon fabric with polyurethane coating High resistant to tearing, impregnated to be washable and waterproof Lucas Nülle GmbH Page 30/35 www.lucas-nuelle.com CLC 40.2 Elevator (lift) model CLC 40.2 Elevator (lift) model Lucas Nülle GmbH Page 31/35 www.lucas-nuelle.com Supplementary equipment set to the basic equipment set CLC 15/30: Supplementary equipment set to the basic equipment set CLC 15/30: Pos. Product name Bestell-Nr. 33 Lift model with three stories LM9545 Anz. 1 Real model of an elevator with cabin for 3 floors and integrated PROFIBUS DP slave. Each floor can be selected from an operating panel and from each floor. Thanks to the open design of this model, each movement sequence can be checked visually. The cabin and the doors on the individual floors are driven by electric motors. Each end position is detected by initiators. All inputs for driving the electric motors and LEDs and all outputs of the feedback signals are connected to the IMS-Connector. 14 digital inputs 11 digital outputs EMERGENCY OFF pushbutton Control elements for each floor 1 x Sub-D, 25-pole 1 x Sub-D, 9-pole Power supply: DC 24V/0.5A Dimensions: 726 x 340 x 125 mm (HxWxD) Depth base: 262 mm Weight: 4.2kg Integrated PROFIBUS DP slave: Address range:16 digital input/outputs PROFIBUS DP connector: 9-pin DSUB socket Rotary switch for setting address Transmission rates of up to 6 Mbit/s GSD file for use with control software (e.g.: STEP7) Lucas Nülle GmbH Page 32/35 www.lucas-nuelle.com Accessories: Pos. Product name Bestell-Nr. 34 IMS interface module for PLC Anz. CO3713-7F 1 LM9061 1 LM9040 1 IMS connector module for extending a SIMATIC S7-300 base system for easy connection of IMS stations and sub-systems avoiding complex wiring and individual cables. Sockets for emergency shutdown loop (Voltage isolation for output modules) 1 D-SUB 25-pin socket 1 D-SUB 9-pin socket Dimensions: 125 x 65 x 25mm (HxWxD) 35 25-pin serial interface cable, Sub-D plug/socket 25 pin Sub-D connection cable Length: 2m Connection: 25-pin plug / 25-pin socket Pin assignment: 1:1 36 Serial interface cable 9/9 pole 9-pin SUB-D cable Length: 2m Connector: 9-pin plug/9-pin socket Pin assignment: 1:1 Lucas Nülle GmbH Page 33/35 www.lucas-nuelle.com Media: Pos. Product name Bestell-Nr. 37 Manual CLC 40.2, Control techniques using authentic PLC process models Anz. SH5004-6D 1 High-quality, bound, colour teachers’ manual with rigid spine, including solutions. CD-ROM with additional students’ manual, including exercises and worksheets. Details: Theoretical background Colour CAD drawings for experiment set-ups and circuits Exercises and worksheets Printed on high-quality 100-g/m² colour copy paper, book cover on 210-g/m² glossy paper Training contents: General introduction Lift control via PLC Introduction System and performance specifications Layout and wiring plan Creating a project with the SIMATIC Manager Assignment list Exercise 1: Door control Exercise 2: Cab control Exercise 3: 2-floor elevator control Exercise 4: 3-floor elevator control Exercise 5: Sequence with door control Exercise 6: Lift control requirements Lucas Nülle GmbH Page 34/35 www.lucas-nuelle.com 38 QuickChart, Elevator model (GB) SO6200-5G 1 Short documentation covering the putting into operation of complex equipment and experiment set-ups. Terminal assignment, safety instructions, help Circuit and assembly diagrams Color print in DIN A3 format Laminated: 2 x 250 µm Optional accessories for conventional integration of PLC system models Pos. Product name Bestell-Nr. 39 IMS connector card 25-pin Anz. SO3713-7Y 1 SO3713-7Z 1 Universal adapter for connecting experiment stations with different connectors. With clamp for attaching to terminal rails and with the following connectors: 25-pin D-Sub connector 25-pin terminal strip 25 x 4mm experiment sockets 40 IMS connector card 9-pin Universal adapter for connecting experiment stations with different connectors. With clamp for attaching to terminal rails and with the following connectors: 9-pin D-Sub connector 9-pin terminal strip 9 x 4mm experiment sockets Lucas Nülle GmbH Page 35/35 www.lucas-nuelle.com