Kalibratieservice Kern DAkkS (Deutscher Kalibrierdienst).

Transcription

Kalibratieservice Kern DAkkS (Deutscher Kalibrierdienst).
Kalibratieservice
The Deutsche Akkreditierungsstelle GmbH (DAkkS)
(German accreditation body)
The Deutsche Akkreditierungsstelle GmbH (DAkkS),
successor of the German Calibration Service (DKD), is
responsible for measuring “correctly” in accordance with
legally binding international standards. It is part of
DAkkS = Deutsche Akkreditierungstelle (German accreditation
authority) which was founded in Germany. The basis is
the European range of standards DIN EN ISO/IEC 17000
for conformity assessment, in particular the accreditation
standard 17025, which governs the organisation of a
calibration laboratory, as well as basic metrological technical
requirements.
• In combination with periodic recalibration we can offer you a
wide range of further services:
- Reconditioning of weights, e.g. cast weights
(sand blasting, painting, adjustment etc.)
- Collection service with special transport packaging,
even for heavy weights
- Volume determination for weights of accuracy class E1
- Measuring of sensitivity (magnetic characteristics)
• Calibration of force-measuring devices
• DAkkS calibration certificates in the following languages
DE, GB, FR, IT, ES, NL
DAkkS calibration (DKD)
Only an accredited calibration laboratory can issue a DAkkS
calibration (DKD) certificate. This defines not only the
measuring method as well as the measuring result, but also
gives information on tracing the test medium to national
standards and the relevant uncertainty of measurement.
Why?
DAkkS calibration (DKD) is always necessary when
checking equipment (balance or test weight) is to
be used in a QM process (e.g. to ISO 9000ff, GS
9000, TS 16949, VDA 6.1, FDA, GLP, GMP, GMP etc.)
You are certified to ...
ISO 9001, QS 9000, GLP, GMP, TS16949
What?
Any checking equipment in proper condition can be
DAkkS calibrated (DKD)
You need …
to control your measuring equipment
How?
Determination of accuracy throughout the world
by a laboratory which is accredited to DIN EN ISO
17025. Traceability to internationally recognised
standards. The DAkkS calibration (DKD) certificate
confirms both the measurement characteristics
of the checking equipment and the general
requirements for the control of checking equipment.
Our solution ...
DAkkS calibration certificate (DKD); (traceability,
measuring uncertainty, internationally
recognised)
KERN – Precision is our business
The KERN calibration laboratory for electronic balances
and weights has been DKD accredited since 1994 and
today it is one of the most modern and best-equipped
DAkkS calibration laboratories for balances, test weights
and force measurement in Europe.
Where? Internationally recognised – this is monitored by
ILAC (International Laboratory Accreditation
Cooperation) and e.g. DAkkS (German calibration
service) in Germany
When?
Operator control the use of checking equipment and
periodic recalibration time intervals themselves
Thanks to the high level of automation, we can carry out
DAkkS calibration (DKD) of balances, test weights and
force-measuring devices 24 hours a day, 7 days a week.
Do you have any further requests or questions on this
matter? We would be pleased to help you or visit us on
the web at www.kern-lab.com
Range of services:
• DAkkS calibration (DKD) of balances with a maximum
load of up to 50.000 kg
• DAkkS calibration (DKD) of weights in the range of
1 mg – 2.500 kg. Calibrations can be carried out in the
following classes: E1, E2, F1, F2, M1, M2, M3
• Database supported management of checking equipment
and reminding service
Imlab
Oude Vijvers 1
3370 Boutersem
Tel.: +32(0)16 73 55 72
Fax: +32(0)16 73 55 87
info@imlab.be
www.imlab.be
Calibration service for balances (DAkkS calibration)
The advantages of using the KERN in-house calibration
KERN & Sohn GmbH
Älteste europäische Feinwaagen und Gewichtefabrik seit 1844
Oldest European Manufacturer of Precision Balances since 1844
akkreditiert durch die / accredited by the
Deutsche Akkreditierungsstelle GmbH
als Kalibrierlaboratorium im / as calibration laboratory in
Deutschen Kalibrierdienst
Sample
D-K19408-01-00
Kalibrierschein
Kalibrierzeichen
Calibration Certificate
Calibration mark
Gegenstand
Präzisionswaage
Object
KERN & Sohn GmbH
Ziegelei 1
72336 Balingen
GERMANY
Manufacturer
PLJ 600-3CM
Typ
Type
123456789
Deutschland
Fabrikate/Serien-Nr.
Serial number
Auftraggeber
This calibration certificate documents the
traceability to national standards, which realize
the units of measurement according to the
International System of Units (SI). The DAkk
is signator to the m ltilateral agreements o
Mustermann GmbH
Musterstraße 1
12345 Musterort
Deutschland
/ Measurement results
Customer
2014-05
Dieser Kalibrierschein dokumentiert die
Rückführung auf nationale Normale zur
Darstellung der Einheiten in Übereinstimmung mit dem Internationalen
Einheitensystem (SI).
Die DAkkS ist Unterzeichner der multilateralen Übereinkommen der European
co-operation for Accreditation (EA) und
der International Laboratory Accreditation
Cooperation (ILAC) zur gegenseitigen
Anerkennung der Kalibrierscheine.
Für die Einhaltung einer angemessenen
Frist zur Wiederholung der Kalibrierung ist
der Benutzer verantwortlich.
Precision Balance
Hersteller
Messergebnisse
1. Wiederholbarkeit / Repeatability
Messung
Prüflast
Measuring
Load
499,999 g
499,999 g
500,000 g
500,000 g
500,000 g
tThe recalibration schedule depends on the frequency of use, the conditions
of use and the safety requirements.
tWe would recommend that you recalibrate your balances every 6 months
if they are used intensively, and every 12 months with normal use.
s = 0,0006 g
Standard deviation:
3. Außermittige Belastung / Eccentricity
2. Richtigkeit / Linearity
Prüflast
Waagenanzeige
Position
Prüflast
Waagenanzeige
Load
Indication
Position
Load
Indication
100,000 g
200,000 g
300,001 g
500,000 g
600,001 g
No. 1
No. 2
No. 3
No. 4
500 g
500 g
500 g
500 g
500,000 g
499,999 g
500,001 g
500,001 g
Initial calibration and recalibration of balance
at the KERN factory
Messunsicherheit U / Measuring uncertainty U
Messunsicherheit U
Last
Abweichung
Erweiterungsfaktor k
Unsicherheit
relative
Unsicherheit
Load
Error
Coverage factor
Uncertainty
Rel. uncertainty
100 g
200 g
300 g
500 g
600 g
0,000 g
0,000 g
0,001 g
0,000 g
0,001 g
2,38
2,32
2,24
2,12
2,08
0,0016 g
0,0016 g
0,0017 g
0,0018 g
0,0020 g
0,00154 %
0,00078 %
0,00053 %
0,00036 %
0,00032 %
Abweichung /
Error in g
Darstellung im Diagramm / Representation as chart:
0,0040
0,0030
0,0020
0,0010
0,0000
-0,0010
-0,0020
-0,0030
0
100
200
300
400
500
600
700
g
g
Nettobelastung / Net-Load in g
Verwendungsgenauigkeit G
/ Usage accuracy G
Diagramm der Verwendungsgenauigkeit / Graph of usage accuracy:
Verwendungsg. / Usage
accuracy in g
G = 0,0013 g + 8,72·10-6 · mw
0,0080
mw = Nettoanzeige bei
zunehmender Belastung
0,0060
net display with increasing load
0,0040
0,0020
0,0000
0
155
310
465
Last / Load in g
Last / Load in g
620
Prozessgenauigkeit / Process accuracy
Prozessgenauigkeit
/ Process accuracy
Messunsicherheit / Uncertainty
Messunsicherheit / Uncertainty
% 100
% 100
rel. Meßunsicherheit
10
Weighing range
Analytical balances
[Max] ≤ 5 kg
[Max] > 5 kg
Precision balances/Industrial scales
[Max] ≤ 5 kg
[Max] > 5 kg – 50 kg
[Max] > 50 kg – 350 kg
[Max] > 350 kg – 1500 kg
[Max] > 1500 kg – 2900 kg1)
[Max] > 2900 kg – 6000 kg1)
[Max] > 6000 kg – 12000 kg1)
Hanging scales/Crane scales
[Max] ≤ 5 kg
[Max] > 5 kg – 50 kg
[Max] > 50 kg – 350 kg
[Max] > 350 kg – 1500 kg
[Max] > 1500 kg – 2900 kg
[Max] > 2900 kg – 6000 kg
[Max] > 6000 kg – 12000 kg 3)
[Max] > 12000 kg – 31000 kg 4) (recalibration only)
[Max] > 31000 kg – 50000 kg 4) (recalibration only)
Preparation for recalibration
(cleaning, adjustment, function test)
Additional services
Minimum weight of sample (for details see internet)
1
0,1
0,01
Mindesteinwaage / Minimum weight of sample
0,001
0,01
We visit you.
In Germany, KERN has access to a comprehensive network of employees at
the KERN DAkkS calibration laboratory, who can carry out on-site calibration
of scales up to 50 t.
The calibration service is independent of the brand.
Preliminary maintenance work by agreement.
Prices for on-site calibration on request.
Recalibration
Waagenanzeige
500 g
500 g
500 g
500 g
500 g
100 g
200 g
300 g
500 g
600 g
The advantages of using the KERN on-site calibration
Indication
No. 1
No. 2
No. 3
No. 4
No. 5
Standardabweichung:
You send your balance to us.
Recommendable with new equipment and for balances which can be transported
economically, as the travel costs for on-site calibration are then not applied.
On request, we can also provide a pick-up and collection service with our parcel
service.
0,1
1
10
100
Nettobelastung
Imlab
Oude Vijvers 1
3370 Boutersem
KERN
963-101
963-102
138,176,-
963-127
963-128
963-129
963-130
963-131
963-132
963-133
72,88,105,165,220,440,500,-
963-127H
963-128H
963-129H
963-130H
963-131H
963-132H
963-133H
963-134HR
963-135HR
72,88,105,165,250,500,700,830,830,-
969-003R
20,-
969-103
10,-
DAkkS Express service with delivery time 48 hours
(only on initial purchase, details see p. 188)
962-116
50,- /
scale
Express shipping: Express supplement for guaranteed delivery on
the next working day (if ready for shipment before 12:00 noon)
in GER only
40,- /
parcel
1)
Floor scales & axle load scales only (Price per weighing panel). Please ask for further details.
On request
3)
Processing time 4 working days
4)
Processing time 15 working days
2)
DAkkS calibration certificate for balances (extract)
Official document
Item to be calibrated
Traceability, see page 216
Identification/Applicant
Metrological component
g
1000
Price
excl. of VAT
ex works
€
Measuring uncertainty,
see page 215
Usage accuracy, see page 216
Minimum weight of sample
(additional price)
Tel.: +32(0)16 73 55 72
Fax: +32(0)16 73 55 87
18
info@imlab.be
www.imlab.be
Calibration service for test weights (DAkkS calibration)
Calibration of test weights
KERN & Sohn GmbH
Calibrated measuring equipment requires calibrated checking equipment. For
balances, these are calibrated test weights, also called “standard weights”.
Älteste europäische Feinwaagen und Gewichtefabrik seit 1844
Oldest European Manufacturer of Precision Balances since 1844
akkreditiert durch die / accredited by the
Deutsche Akkreditierungsstelle GmbH
We calibrate test weights
als Kalibrierlaboratorium im / as calibration laboratory in the
Deutschen Kalibrierdienst
G1-123
D-K19408-01-00
Kalibrierschein
Kalibrierzeichen
Calibration certificate
Calibration mark
Gegenstand
Gewichtssatz, 1 mg - 1 kg
Klasse E2
Object
Set of weights, 1 mg - 1 kg
Class E2
Hersteller
KERN & Sohn GmbH
Ziegelei 1
D-72336 Balingen
Germany
Manufacturer
313-052
Typ
Type
G123456789
Fabrikate/Serien-Nr.
Serial number
Auftraggeber
Mustermann GmbH
Customer
Teststr.1
42446 Musterstadt
Deutschland
Auftragsnummer
2014-123456789
2014-05
Dieser Kalibrierschein dokumentiert die
Rückführung auf nationale Normale zur
Darstellung der Einheiten in Übereinstimmung mit dem Internationalen
Einheitensystem (SI).
Die DAkkS ist Unterzeichner der multilateralen Übereinkommen der European
co-operation for Accreditation (EA) und
der International Laboratory Accreditation
Cooperation (ILAC) zur gegenseitigen
Anerkennung der Kalibrierscheine.
Für die Einhaltung einer angemessenen
Frist zur Wiederholung der Kalibrierung ist
der Benutzer verantwortlich.
This calibration certificate documents the
traceability to national standards, which realize
the units of measurement according to the
International System of Units (SI).
The DAkkS is signatory to the multilateral
agreements of the European co-operation for
Accreditation (EA) and of the International
Laboratory Accreditation Cooperation (ILAC) for
the mutual recognition of calibration certificates.
The user is obliged to have the objec
recalibrated at appropriate intervals.
Order No.
3
Anzahl der Seiten des Kalibrierscheines
Number of pages of the certificate
Kalibrierverfahren:
Die Kalibrierung erfolgte durch Vergleich mit den Bezugsnormalen
des Kalibrierlaboratoriums nach der Substitutionsmethode mit Auftriebskorrektur.
Calibration method
The calibration ensued through comparison with the reference standards of the
calibration laboratory using the substitution method with air buoyancy correction.
Umgebungsbedingungen:
Die Kalibrierung wurde bei folgenden Umgebungsbedingungen ausgeführt:
Ambient conditions
The calibration was carried out under the following ambient conditions:
von
Temperatur (°C)
temperature
rel. Luftfeuchte (%)
relative humidity
Luftdruck (hPa)
air pressure
Referenzgewichte:
bis
Unsicherheit
from
to
uncertainty
22,9
24,1
0,1
48,5
53,4
2,0
942,5
948,5
0,3
tIn all classes with permissible error limits E1 – M3 according to OIML R111-2004
(for tolerance tables, see page 190), in sizes 1 mg to 2500 kg.
tWith free nominal value
tNewton (N)
tIndependent of design (special designs)
The advantages of using the KERN in-house calibration
You send your test weights to us.
tE xcellent price performance ratio
tThe quickest processing time
- DAkkS standard service: 4 working days
- DAkkS express service: 48 hrs (new weights)
tThe most modern calibration methods with robot controlled comparators
allow the most accurate calibration results and fastest throughput time
tKERN DAkkS calibration certificates are internationally recognised
tA calibration service which is independent of the brand
tKERN also reconditions existing customer weights (e.g. cleaning or readjustment)
tOn request, we can also provide a pick-up and collection service with our
parcel service
G1-123-D-K-19408-01-00-2014-05
Standard weights
The advantages of using the KERN on-site calibration
Material / angenommene Dichte:
Material / assumed density
Nennwert
Dichte
Unsicherheit
Material
Form
nominal value
density
uncertainty
material
shape
1 mg - 500 mg
7950 kg/m³
140 kg/m³
1 g - 1 kg
8000 kg/m³
100 kg/m³
Edelstahl
Draht
Stainless steel
Wire
Edelstahl
Knopf
Stainless steel
Cylindrical form
We visit you.
We would be pleased to visit you within Germany and carry out the calibration of
your reference standards to OIML classes M1 – M3, 10 kg, 20 kg, 25 kg, 40 kg,
50 kg with permissible error limits, using our mobile MACOS system. Minimized
downtime of your checking equipment and direct contact with our expert are the
major benefits of this service. Price on request.
Messergebnisse:
Measurement results:
Nennwert
Kennzeichnung
konventioneller
Wägewert
Unsicherheit
k=2
Fehlergrenze
nominal value
marking
conventional mass
uncertainty
max. perm. error
1
2
2
5
10
20
20
50
100
200
200
500
1
2
2
5
10
20
20
50
100
200
200
500
1
mg
mg
mg
mg
mg
mg
mg
mg
mg
mg
mg
mg
g
g
g
g
g
g
g
g
g
g
g
g
kg
*
*
*
*
*
*
1
2
2
5
10
20
20
50
100
200
200
500
1
2
2
5
10
20
20
50
100
200
200
500
1
mg
mg
mg
mg
mg
mg
mg
mg
mg
mg
mg
mg
g
g
g
g
g
g
g
g
g
g
g
g
kg
+ 0,0010
+ 0,0005
+ 0,0016
+ 0,0010
+ 0,0009
- 0,001
+ 0,001
+ 0,001
+ 0,001
+ 0,002
+ 0,003
+ 0,005
+ 0,002
+ 0,002
+ 0,002
+ 0,010
- 0,007
+ 0,005
+ 0,015
+ 0,02
+ 0,01
+ 0,05
- 0,00
+ 0,10
+ 0,1
mg
mg
mg
mg
mg
mg
mg
mg
mg
mg
mg
mg
mg
mg
mg
mg
mg
mg
mg
mg
mg
mg
mg
mg
mg
0,0020 mg
0,0020 mg
0,0020 mg
0,0020 mg
0,0020 mg
0,003 mg
0,003 mg
0,004 mg
0,005 mg
0,006 mg
0,006 mg
0,008 mg
0,010 mg
0,013 mg
0,013 mg
0,016 mg
0,020 mg
0,026 mg
0,026 mg
0,03 mg
0,05 mg
0,10 mg
0,10 mg
0,26 mg
0,5
mg
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
0,0060 mg
0,0060 mg
0,0060 mg
0,0060 mg
0,0080 mg
0,010 mg
0,010 mg
0,012 mg
0,016 mg
0,020 mg
0,020 mg
0,025 mg
0,030 mg
0,040 mg
0,040 mg
0,050 mg
0,060 mg
0,080 mg
0,080 mg
0,10 mg
0,16 mg
0,30 mg
0,30 mg
0,80 mg
1,6
mg
Klasse*
class*
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
DAkkS calibration certificate for test weights (extract)
For more details on our calibration service and other useful
information, please see the internet on www.kern-lab.com
18
Recalibration
tThe recalibration schedule depends on the frequency of use, the conditions of
use and the safety requirements.
tIn terms of standardisation, no particular recalibration interval is specified.
tWe would recommend that you recalibrate your test weights every 6 months
if they are used intensively, and every 12 months with normal use.
tWe would be pleased to monitor your recalibration schedule.
Official document
Item to be calibrated
Traceability, see page 216
Identification/Applicant
Environmental conditions
Metrological component
Conventional mass
Measuring uncertainty, see page 215
Note:
For more information on this
subject, please see our KERN
DAkkS calibration service brochure –
just request your free copy.
Imlab
Oude Vijvers 1
3370 Boutersem
Tel.: +32(0)16 73 55 72
Fax: +32(0)16 73 55 87
info@imlab.be
www.imlab.be
Recalibration price of test weights (DAkkS calibration)
Class acc.
OIML R111-2004
E1
with volume determination
Nominal value
KERN
1 mg
2 mg
5 mg
10 mg
20 mg
50 mg
100 mg
200 mg
500 mg
1g
2g
5g
10 g
20 g
50 g
100 g
200 g
500 g
1 kg
2 kg
5 kg
10 kg
20 kg
50 kg
100 kg
200 kg
500 kg
1000 kg
2000 kg
1 mg – 500 mg
1 mg – 50 g
1 mg – 100 g
1 mg – 200 g
1 mg – 500 g
1 mg – 1 kg
1 mg – 2 kg
1 mg – 5 kg
1 mg – 10 kg
1 g – 50 g
1 g – 100 g
1 g – 200 g
1 g – 500 g
1 g – 1 kg
1 g – 2 kg
1 g – 5 kg
1 g – 10 kg
–
–
–
–
–
–
–
–
–
963-231
963-232
963-233
963-234
963-235
963-236
963-237
963-238
963-239
963-241
963-242
963-243
963-244
963-245
963-246
–
–
–
–
–
–
963-201
963-202
963-203
963-204
963-205
963-206
963-207
963-208
963-215
963-216
963-217
963-218
963-219
963-220
963-221
963-222
Price €
excl. of VAT
ex works
–
–
–
–
–
–
–
–
–
193,193,193,193,193,193,193,193,193,193,465,465,465,1160,1360,–
–
–
–
–
–
1070,1170,1350,1440,1530,2000,2450,2900,770,860,1040,1130,1230,1780,2230,2690,-
KERN
962-251R
962-252R
962-253R
962-254R
962-255R
962-256R
962-257R
962-258R
962-259R
962-231R
962-232R
962-233R
962-234R
962-235R
962-236R
962-237R
962-238R
962-239R
962-241R
962-242R
962-243R
962-244R
962-245R
962-246R
–
–
–
–
–
962-250R
962-201R
962-202R
962-203R
962-204R
962-205R
962-206R
962-207R
962-208R
962-215R
962-216R
962-217R
962-218R
962-219R
962-220R
962-221R
962-222R
Price €
excl. of VAT
ex works
52,52,52,52,52,52,52,52,52,52,52,52,52,52,52,52,52,52,52,64,64,64,590,660,–
–
–
–
–
350,560,580,630,660,700,750,770,800,245,270,320,350,375,425,450,485,-
Additional costs
for preparation, overhaul and adjustment before the calibration
Preparation of weights (e.g. cleaning, etc.)
Single weight
Weight set
Subsequent services are carried out aer confirmation
Continued overhaul of weights
(e.g. wet-cleaning, markings, repair, special packaging, adjustment E1
(DAkkS only), E2 ...)
Adjustment, per weight
only available for weights with adjustment chamber (F1 – M3)
Second calibration aer adjustment or substitution, per weight
Class E1
Class E1 incl. volume determination
Class E2
Class F1/F2
Class M1 – M3
Testing of magnetic properties according to OIML R111-2004,
per weight
Calibration of NON-OIML test weights, additional price per weight
Imlab
Oude Vijvers 1
3370 Boutersem
E2
E1 without volume
determination
F1/F2
* F2 only
KERN
962-351R
962-352R
962-353R
962-354R
962-355R
962-356R
962-357R
962-358R
962-359R
962-331R
962-332R
962-333R
962-334R
962-335R
962-336R
962-337R
962-338R
962-339R
962-341R
962-342R
962-343R
962-344R
962-345R
962-346R
–
–
–
–
–
962-350R
962-301R
962-302R
962-303R
962-304R
962-305R
962-306R
962-307R
962-308R
962-315R
962-316R
962-317R
962-318R
962-319R
962-320R
962-321R
962-322R
KERN
Price €
excl. of VAT
ex works
26,26,26,26,26,26,26,26,26,26,26,26,26,26,26,33,33,33,33,41,41,41,52,64,–
–
–
–
–
190,315,340,385,410,435,495,530,560,127,150,196,220,245,305,340,370,-
Price €
excl. of VAT
ex works
969-001R
969-002R
3,16,-
969-005R
T&M
basis
969-010R
12,-
969-210R
969-211R
969-310R
969-410R
969-610R
40,80,14,14,14,-
972-000
12,-
–
8,-
Tel.: +32(0)16 73 55 72
Fax: +32(0)16 73 55 87
Price €
excl. of VAT
ex works
962-451R
18,962-452R
18,962-453R
18,962-454R
18,962-455R
18,962-456R
18,962-457R
18,962-458R
18,962-459R
18,962-431R
18,962-432R
18,962-433R
18,962-434R
18,962-435R
18,962-436R
18,962-437R
20,962-438R
20,962-439R
20,962-441R
20,962-442R
25,962-443R
25,962-444R
25,962-445R
28,962-446R
39, 962-591R*
116,962-592R*
116,962-593R*
116,–
–
–
–
962-450R
100,962-401R
167,962-402R
178,962-403R
199,962-404R
210,962-405R
220,962-406R
250,962-407R
265,962-408R
285,962-415R
67,962-416R
77,962-417R
98,962-418R
109,962-419R
119,962-420R
151,962-421R
166,962-422R
182,-
KERN
M1/M2/M3
Price €
excl. of VAT
ex works
KERN
962-651R
962-652R
962-653R
962-654R
962-655R
962-656R
962-657R
962-658R
962-659R
962-631R
962-632R
962-633R
962-634R
962-635R
962-636R
962-637R
962-638R
962-639R
962-641R
962-642R
962-643R
962-644R
962-645R
962-646R
962-691R
962-692R
962-693R
962-694R
962-695R
962-650R
962-601R
962-602R
962-603R
962-604R
962-605R
962-606R
962-607R
962-608R
962-615R
962-616R
962-617R
962-618R
962-619R
962-620R
962-621R
962-622R
15,15,15,15,15,15,15,15,15,15,15,15,15,15,15,16,16,16,16,17,17,17,22,24,63,63,63,136,250,63,106,112,125,131,137,152,160,167,42,49,61,68,74,89,96,104,-
KERN DAkkS Express Service
4 working days
DAkkS standard service Class E2 – M3
DAkkS standard service Class E1,
1 mg – 500 mg, and recalibration
1 g –10 kg with a known volume
Class E1, 1 g – 2 kg,
incl. volume determination (new weights)
10 working days
15 working days
Class E1, ≥ 2 kg,
incl. volume determination (new weights)
15 working days
DAkkS Express service in 48 hours
except for class E1
tUrgent order is received at KERN by 12:00 noon at the latest
tReady for shipping at KERN within two working days,
at 12:00 noon
tReturn by standard parcel service or express shipping
(Costs and processing time on request)
tAdditional cost for DAkkS Express Service, for each
KERN test weight KERN KERN 962-115 € 20,–
tFor Express shipping, see page 209
info@imlab.be
www.imlab.be
18
Verification prices for test weights
Class acc.
OIML R111-2004
E2 with verification
certificate
Nominal value
KERN
1 mg
2 mg
5 mg
10 mg
20 mg
50 mg
100 mg
200 mg
500 mg
1g
2g
5g
10 g
20 g
50 g
100 g
200 g
500 g
1 kg
2 kg
5 kg
10 kg
20 kg
50 kg
1 mg – 500 mg
1 mg – 50 g
1 mg – 100 g
1 mg – 200 g
1 mg – 500 g
1 mg – 1 kg
1 mg – 2 kg
1 mg – 5 kg
1 mg – 10 kg
1 g – 50 g
1 g – 100 g
1 g – 200 g
1 g – 500 g
1 g – 1 kg
1 g – 2 kg
1 g – 5 kg
1 g – 10 kg
Price
excl. of VAT
ex works
€
40,40,40,40,40,40,40,40,40,40,40,40,40,40,40,45,45,45,45,51,51,51,59,67,200,330,360,405,430,455,520,560,590,133,157,205,235,255,320,355,390,-
952-351
952-352
952-353
952-354
952-355
952-356
952-357
952-358
952-359
952-331
952-332
952-333
952-334
952-335
952-336
952-337
952-338
952-339
952-341
952-342
952-343
952-344
952-345
952-346
952-350
952-301
952-302
952-303
952-304
952-305
952-306
952-307
952-308
952-315
952-316
952-317
952-318
952-319
952-320
952-321
952-322
F1/F2 with verification
certificate
KERN
952-451
952-452
952-453
952-454
952-455
952-456
952-457
952-458
952-459
952-431
952-432
952-433
952-434
952-435
952-436
952-437
952-438
952-439
952-441
952-442
952-443
952-444
952-445
952-446
952-450
952-401
952-402
952-403
952-404
952-405
952-406
952-407
952-408
952-415
952-416
952-417
952-418
952-419
952-420
952-421
952-422
Price
excl. of VAT
ex works
€
35,35,35,35,35,35,35,35,35,35,35,35,35,35,35,35,36,36,36,40,40,40,42,50,105,175,187,210,220,230,260,280,300,76,81,103,114,125,158,174,191,-
M1 with verification
certificate
KERN
952-651
952-652
952-653
952-654
952-655
952-656
952-657
952-658
952-659
952-631
952-632
952-633
952-634
952-635
952-636
952-637
952-638
952-639
952-641
952-642
952-643
952-644
952-645
952-646
952-650
952-601
952-602
952-603
952-604
952-605
952-606
952-607
952-608
952-615
952-616
952-617
952-618
952-619
952-620
952-621
952-622
Price
excl. of VAT
ex works
€
24,24,24,24,24,24,24,24,24,24,24,24,24,24,24,24,24,24,24,25,25,32,36,37,66,111,117,131,137,144,159,168,175,50,54,64,71,78,93,101,109,-
KERN verification delivery time
Standard verification service
Class E2 – M1
Additional costs
for preparation, overhaul
and adjustment before the
verification
6 working days
Price
excl. of VAT
ex works
€
KERN
Preparation of weights (e.g. cleaning, etc.)
Single weight
969-008R
3,-
Weight set
969-009R
16,-
Subsequent services are carried out aer
confirmation
Continued overhaul
of weights
(e.g. wet-cleaning, markings, 969-005R
repair, special packaging,
adjustment E2 ...)
Adjustment, per weight
only available for weights
with adjustment chamber
(F1/F2 – M1)
969-010R
T&M
basis
12,-
Verification aer adjustment or substitution,
per weight
Class E2
969-310R
14,-
Class F1/F2
969-410R
14,-
Class M1/M3
969-610R
14,-
Verification prices for electronic balances (electronic crane scales, see page 213)
Initial
verification
Checking equipment
KERN
965-201
965-202
965-216
965-217
965-218
965-227
965-228
965-229
965-230
965-231
965-232
Electronic balances, class I, [Max] ≤ 5 kg 1)
Electronic balances, class I, [Max] > 5 kg 1)
Electronic balances, class II, [Max] ≤ 5 kg 1)
Electronic balances, class II, [Max] > 5 kg – 50 kg 1)
Electronic balances, class II, [Max] > 50 kg – 350 kg 1)
Electronic balances, class III–IV, [Max] ≤ 5 kg 1)
Electronic balances, class III–IV, [Max] > 5 kg – 50 kg 1)
Electronic balances, class III–IV, [Max] > 50 kg – 350 kg 1)
Electronic balances, class III–IV, [Max] > 350 kg – 1500 kg 1)
Electronic balances, class III–IV, [Max] > 1500 kg – 2900 kg 1)
Electronic balances, class III–IV, [Max] > 2900 kg – 6000 kg 1)
1)
processing time 4 working days,
2)
Price
excl. of VAT
ex works
€
110,110,66,77,110,55,55,93,132,220,320,-
Subsequent
verification
KERN
950-101R
950-102R
950-116R
950-117R
950-118R
950-127R
950-128R
950-129R
950-130R
950-131R
950-132R
Price
excl. of VAT
ex works
€
180,230,90,110,170,86,86,138,200,280,430,-
processing time 15 working days
18
Imlab
Oude Vijvers 1
3370 Boutersem
Tel.: +32(0)16 73 55 72
Fax: +32(0)16 73 55 87
info@imlab.be
www.imlab.be
Verification prices for electronic crane scales
Initial
verification
Checking equipment
KERN
950-129H
950-130H
950-131H
950-132H
950-133H
–
–
Electronic crane scales, class III–IV, [Max] > 50 kg – 350 kg 1)
Electronic crane scales, class III–IV, [Max] > 350 kg – 1500 kg 1)
Electronic crane scales, class III–IV, [Max] > 1500 kg – 2900 kg 1)
Electronic crane scales, class III–IV, [Max] > 2900 kg – 6000 kg 1)
Electronic crane scales, class III–IV, [Max] > 6000 kg – 12000 kg 1)
Electronic crane scales, class III–IV, [Max] > 12000 kg – 31000 kg 2)
Electronic crane scales, class III–IV, [Max] > 31000 kg – 50000 kg 2)
1)
processing time 4 working days,
2)
Price
excl. of VAT
ex works
€
105,200,270,500,700,–
–
Subsequent
verification
KERN
950-129HR
950-130HR
950-131HR
950-132HR
950-133HR
950-134HR
950-135HR
Price
excl. of VAT
ex works
€
150,250,360,550,870,1060,1060,-
processing time 15 working days
Factory calibration certificates (ISO calibration)
Mechanical hanging scales, prices for initial calibration and recalibration
Checking equipment
Initial calibration
Recalibration
KERN
961-100
961-101
961-102
961-103
961-104
961-105
961-106
KERN
961-100R
961-101R
961-102R
961-103R
961-104R
961-105R
961-106R
Initial calibration
Recalibration
Tensile force
Tensile force
Mechanical hanging scales (spring scales) [Max] ≤ 5 kg
Mechanical hanging scales [Max] > 5 kg – 50 kg
Mechanical hanging scales [Max] > 50 kg – 350 kg
Mechanical hanging scales [Max] > 350 kg – 1500 kg
Mechanical hanging scales [Max] > 1500 kg – 3000 kg
Mechanical hanging scales [Max] > 3000 kg – 6000 kg
Mechanical hanging scales [Max] > 6000 kg – 12000 kg
Price
excl. of VAT
ex works
€
72,88,105,165,220,440,500,-
Force gauges, tensile force, prices for initial calibration and recalibration
Checking equipment
Force gauges [Max] 300 N, 400 N, 500 N (DAkkS Calibration)
Force gauges [Max] ≤ 500 N
Force gauges [Max] > 500 N – 2 kN
Force gauges [Max] > 2 kN – 10 kN
Force gauges [Max] > 10 kN – 20 kN
Force gauges [Max] > 20 kN – 50 kN
Force gauges [Max] > 50 kN – 120 kN
KERN
KERN
963-161
961-161
961-162
961-163
961-164
961-165
961-166
963-161R
961-161R
961-162R
961-163R
961-164R
961-165R
961-166R
Price
excl. of VAT
ex works
€
250,135,165,225,350,520,940,-
Force gauges, compression force, prices for initial calibration and recalibration
Checking equipment
Initial calibration
Recalibration
Compression force
Compression force
KERN
961-261
961-262
961-263
KERN
961-261R
961-262R
961-263R
Price
excl. of VAT
ex works
€
135,165,225,-
Initial calibration
Tensile force/
Compression force
KERN
961-361
961-362
961-363
Recalibration
Tensile force/
Compression force
KERN
961-361R
961-362R
961-363R
Price
excl. of VAT
ex works
€
245,300,405,-
Initial calibration
Recalibration
KERN
961-131
961-110
961-112
961-113
KERN
961-131R
961-110R
961-112R
961-113R
Price
excl. of VAT
ex works
€
120,120,170,120,-
Force gauges [Max] > 50 N – 500 N
Force gauges [Max] > 500 N – 2 kN
Force gauges [Max] > 2 kN – 5 kN
Force gauges, tensile and compression force, prices for initial calibration and recalibration
Checking equipment
Force gauges [Max] > 50 N – 500 N
Force gauges [Max] > 500 N – 2 kN
Force gauges [Max] > 2 kN – 5 kN
Measuring instruments, prices for initial calibration and recalibration
Checking equipment
Hardness testing devices in accordance with Leeb tests (Type D)
Coating thickness gauges 0 μm – 2000 μm (Ferro or NonFerro)
Coating thickness gauges 0 μm – 2000 μm (Ferro and NonFerro)
Ultrasonic material thickness testing devices 25 mm – 300 mm
Imlab
Oude Vijvers 1
3370 Boutersem
Tel.: +32(0)16 73 55 72
Fax: +32(0)16 73 55 87
info@imlab.be
www.imlab.be
18

Similar documents