Kalibratieservice Kern DAkkS (Deutscher Kalibrierdienst).
Transcription
Kalibratieservice Kern DAkkS (Deutscher Kalibrierdienst).
Kalibratieservice The Deutsche Akkreditierungsstelle GmbH (DAkkS) (German accreditation body) The Deutsche Akkreditierungsstelle GmbH (DAkkS), successor of the German Calibration Service (DKD), is responsible for measuring “correctly” in accordance with legally binding international standards. It is part of DAkkS = Deutsche Akkreditierungstelle (German accreditation authority) which was founded in Germany. The basis is the European range of standards DIN EN ISO/IEC 17000 for conformity assessment, in particular the accreditation standard 17025, which governs the organisation of a calibration laboratory, as well as basic metrological technical requirements. • In combination with periodic recalibration we can offer you a wide range of further services: - Reconditioning of weights, e.g. cast weights (sand blasting, painting, adjustment etc.) - Collection service with special transport packaging, even for heavy weights - Volume determination for weights of accuracy class E1 - Measuring of sensitivity (magnetic characteristics) • Calibration of force-measuring devices • DAkkS calibration certificates in the following languages DE, GB, FR, IT, ES, NL DAkkS calibration (DKD) Only an accredited calibration laboratory can issue a DAkkS calibration (DKD) certificate. This defines not only the measuring method as well as the measuring result, but also gives information on tracing the test medium to national standards and the relevant uncertainty of measurement. Why? DAkkS calibration (DKD) is always necessary when checking equipment (balance or test weight) is to be used in a QM process (e.g. to ISO 9000ff, GS 9000, TS 16949, VDA 6.1, FDA, GLP, GMP, GMP etc.) You are certified to ... ISO 9001, QS 9000, GLP, GMP, TS16949 What? Any checking equipment in proper condition can be DAkkS calibrated (DKD) You need … to control your measuring equipment How? Determination of accuracy throughout the world by a laboratory which is accredited to DIN EN ISO 17025. Traceability to internationally recognised standards. The DAkkS calibration (DKD) certificate confirms both the measurement characteristics of the checking equipment and the general requirements for the control of checking equipment. Our solution ... DAkkS calibration certificate (DKD); (traceability, measuring uncertainty, internationally recognised) KERN – Precision is our business The KERN calibration laboratory for electronic balances and weights has been DKD accredited since 1994 and today it is one of the most modern and best-equipped DAkkS calibration laboratories for balances, test weights and force measurement in Europe. Where? Internationally recognised – this is monitored by ILAC (International Laboratory Accreditation Cooperation) and e.g. DAkkS (German calibration service) in Germany When? Operator control the use of checking equipment and periodic recalibration time intervals themselves Thanks to the high level of automation, we can carry out DAkkS calibration (DKD) of balances, test weights and force-measuring devices 24 hours a day, 7 days a week. Do you have any further requests or questions on this matter? We would be pleased to help you or visit us on the web at www.kern-lab.com Range of services: • DAkkS calibration (DKD) of balances with a maximum load of up to 50.000 kg • DAkkS calibration (DKD) of weights in the range of 1 mg – 2.500 kg. Calibrations can be carried out in the following classes: E1, E2, F1, F2, M1, M2, M3 • Database supported management of checking equipment and reminding service Imlab Oude Vijvers 1 3370 Boutersem Tel.: +32(0)16 73 55 72 Fax: +32(0)16 73 55 87 info@imlab.be www.imlab.be Calibration service for balances (DAkkS calibration) The advantages of using the KERN in-house calibration KERN & Sohn GmbH Älteste europäische Feinwaagen und Gewichtefabrik seit 1844 Oldest European Manufacturer of Precision Balances since 1844 akkreditiert durch die / accredited by the Deutsche Akkreditierungsstelle GmbH als Kalibrierlaboratorium im / as calibration laboratory in Deutschen Kalibrierdienst Sample D-K19408-01-00 Kalibrierschein Kalibrierzeichen Calibration Certificate Calibration mark Gegenstand Präzisionswaage Object KERN & Sohn GmbH Ziegelei 1 72336 Balingen GERMANY Manufacturer PLJ 600-3CM Typ Type 123456789 Deutschland Fabrikate/Serien-Nr. Serial number Auftraggeber This calibration certificate documents the traceability to national standards, which realize the units of measurement according to the International System of Units (SI). The DAkk is signator to the m ltilateral agreements o Mustermann GmbH Musterstraße 1 12345 Musterort Deutschland / Measurement results Customer 2014-05 Dieser Kalibrierschein dokumentiert die Rückführung auf nationale Normale zur Darstellung der Einheiten in Übereinstimmung mit dem Internationalen Einheitensystem (SI). Die DAkkS ist Unterzeichner der multilateralen Übereinkommen der European co-operation for Accreditation (EA) und der International Laboratory Accreditation Cooperation (ILAC) zur gegenseitigen Anerkennung der Kalibrierscheine. Für die Einhaltung einer angemessenen Frist zur Wiederholung der Kalibrierung ist der Benutzer verantwortlich. Precision Balance Hersteller Messergebnisse 1. Wiederholbarkeit / Repeatability Messung Prüflast Measuring Load 499,999 g 499,999 g 500,000 g 500,000 g 500,000 g tThe recalibration schedule depends on the frequency of use, the conditions of use and the safety requirements. tWe would recommend that you recalibrate your balances every 6 months if they are used intensively, and every 12 months with normal use. s = 0,0006 g Standard deviation: 3. Außermittige Belastung / Eccentricity 2. Richtigkeit / Linearity Prüflast Waagenanzeige Position Prüflast Waagenanzeige Load Indication Position Load Indication 100,000 g 200,000 g 300,001 g 500,000 g 600,001 g No. 1 No. 2 No. 3 No. 4 500 g 500 g 500 g 500 g 500,000 g 499,999 g 500,001 g 500,001 g Initial calibration and recalibration of balance at the KERN factory Messunsicherheit U / Measuring uncertainty U Messunsicherheit U Last Abweichung Erweiterungsfaktor k Unsicherheit relative Unsicherheit Load Error Coverage factor Uncertainty Rel. uncertainty 100 g 200 g 300 g 500 g 600 g 0,000 g 0,000 g 0,001 g 0,000 g 0,001 g 2,38 2,32 2,24 2,12 2,08 0,0016 g 0,0016 g 0,0017 g 0,0018 g 0,0020 g 0,00154 % 0,00078 % 0,00053 % 0,00036 % 0,00032 % Abweichung / Error in g Darstellung im Diagramm / Representation as chart: 0,0040 0,0030 0,0020 0,0010 0,0000 -0,0010 -0,0020 -0,0030 0 100 200 300 400 500 600 700 g g Nettobelastung / Net-Load in g Verwendungsgenauigkeit G / Usage accuracy G Diagramm der Verwendungsgenauigkeit / Graph of usage accuracy: Verwendungsg. / Usage accuracy in g G = 0,0013 g + 8,72·10-6 · mw 0,0080 mw = Nettoanzeige bei zunehmender Belastung 0,0060 net display with increasing load 0,0040 0,0020 0,0000 0 155 310 465 Last / Load in g Last / Load in g 620 Prozessgenauigkeit / Process accuracy Prozessgenauigkeit / Process accuracy Messunsicherheit / Uncertainty Messunsicherheit / Uncertainty % 100 % 100 rel. Meßunsicherheit 10 Weighing range Analytical balances [Max] ≤ 5 kg [Max] > 5 kg Precision balances/Industrial scales [Max] ≤ 5 kg [Max] > 5 kg – 50 kg [Max] > 50 kg – 350 kg [Max] > 350 kg – 1500 kg [Max] > 1500 kg – 2900 kg1) [Max] > 2900 kg – 6000 kg1) [Max] > 6000 kg – 12000 kg1) Hanging scales/Crane scales [Max] ≤ 5 kg [Max] > 5 kg – 50 kg [Max] > 50 kg – 350 kg [Max] > 350 kg – 1500 kg [Max] > 1500 kg – 2900 kg [Max] > 2900 kg – 6000 kg [Max] > 6000 kg – 12000 kg 3) [Max] > 12000 kg – 31000 kg 4) (recalibration only) [Max] > 31000 kg – 50000 kg 4) (recalibration only) Preparation for recalibration (cleaning, adjustment, function test) Additional services Minimum weight of sample (for details see internet) 1 0,1 0,01 Mindesteinwaage / Minimum weight of sample 0,001 0,01 We visit you. In Germany, KERN has access to a comprehensive network of employees at the KERN DAkkS calibration laboratory, who can carry out on-site calibration of scales up to 50 t. The calibration service is independent of the brand. Preliminary maintenance work by agreement. Prices for on-site calibration on request. Recalibration Waagenanzeige 500 g 500 g 500 g 500 g 500 g 100 g 200 g 300 g 500 g 600 g The advantages of using the KERN on-site calibration Indication No. 1 No. 2 No. 3 No. 4 No. 5 Standardabweichung: You send your balance to us. Recommendable with new equipment and for balances which can be transported economically, as the travel costs for on-site calibration are then not applied. On request, we can also provide a pick-up and collection service with our parcel service. 0,1 1 10 100 Nettobelastung Imlab Oude Vijvers 1 3370 Boutersem KERN 963-101 963-102 138,176,- 963-127 963-128 963-129 963-130 963-131 963-132 963-133 72,88,105,165,220,440,500,- 963-127H 963-128H 963-129H 963-130H 963-131H 963-132H 963-133H 963-134HR 963-135HR 72,88,105,165,250,500,700,830,830,- 969-003R 20,- 969-103 10,- DAkkS Express service with delivery time 48 hours (only on initial purchase, details see p. 188) 962-116 50,- / scale Express shipping: Express supplement for guaranteed delivery on the next working day (if ready for shipment before 12:00 noon) in GER only 40,- / parcel 1) Floor scales & axle load scales only (Price per weighing panel). Please ask for further details. On request 3) Processing time 4 working days 4) Processing time 15 working days 2) DAkkS calibration certificate for balances (extract) Official document Item to be calibrated Traceability, see page 216 Identification/Applicant Metrological component g 1000 Price excl. of VAT ex works € Measuring uncertainty, see page 215 Usage accuracy, see page 216 Minimum weight of sample (additional price) Tel.: +32(0)16 73 55 72 Fax: +32(0)16 73 55 87 18 info@imlab.be www.imlab.be Calibration service for test weights (DAkkS calibration) Calibration of test weights KERN & Sohn GmbH Calibrated measuring equipment requires calibrated checking equipment. For balances, these are calibrated test weights, also called “standard weights”. Älteste europäische Feinwaagen und Gewichtefabrik seit 1844 Oldest European Manufacturer of Precision Balances since 1844 akkreditiert durch die / accredited by the Deutsche Akkreditierungsstelle GmbH We calibrate test weights als Kalibrierlaboratorium im / as calibration laboratory in the Deutschen Kalibrierdienst G1-123 D-K19408-01-00 Kalibrierschein Kalibrierzeichen Calibration certificate Calibration mark Gegenstand Gewichtssatz, 1 mg - 1 kg Klasse E2 Object Set of weights, 1 mg - 1 kg Class E2 Hersteller KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen Germany Manufacturer 313-052 Typ Type G123456789 Fabrikate/Serien-Nr. Serial number Auftraggeber Mustermann GmbH Customer Teststr.1 42446 Musterstadt Deutschland Auftragsnummer 2014-123456789 2014-05 Dieser Kalibrierschein dokumentiert die Rückführung auf nationale Normale zur Darstellung der Einheiten in Übereinstimmung mit dem Internationalen Einheitensystem (SI). Die DAkkS ist Unterzeichner der multilateralen Übereinkommen der European co-operation for Accreditation (EA) und der International Laboratory Accreditation Cooperation (ILAC) zur gegenseitigen Anerkennung der Kalibrierscheine. Für die Einhaltung einer angemessenen Frist zur Wiederholung der Kalibrierung ist der Benutzer verantwortlich. This calibration certificate documents the traceability to national standards, which realize the units of measurement according to the International System of Units (SI). The DAkkS is signatory to the multilateral agreements of the European co-operation for Accreditation (EA) and of the International Laboratory Accreditation Cooperation (ILAC) for the mutual recognition of calibration certificates. The user is obliged to have the objec recalibrated at appropriate intervals. Order No. 3 Anzahl der Seiten des Kalibrierscheines Number of pages of the certificate Kalibrierverfahren: Die Kalibrierung erfolgte durch Vergleich mit den Bezugsnormalen des Kalibrierlaboratoriums nach der Substitutionsmethode mit Auftriebskorrektur. Calibration method The calibration ensued through comparison with the reference standards of the calibration laboratory using the substitution method with air buoyancy correction. Umgebungsbedingungen: Die Kalibrierung wurde bei folgenden Umgebungsbedingungen ausgeführt: Ambient conditions The calibration was carried out under the following ambient conditions: von Temperatur (°C) temperature rel. Luftfeuchte (%) relative humidity Luftdruck (hPa) air pressure Referenzgewichte: bis Unsicherheit from to uncertainty 22,9 24,1 0,1 48,5 53,4 2,0 942,5 948,5 0,3 tIn all classes with permissible error limits E1 – M3 according to OIML R111-2004 (for tolerance tables, see page 190), in sizes 1 mg to 2500 kg. tWith free nominal value tNewton (N) tIndependent of design (special designs) The advantages of using the KERN in-house calibration You send your test weights to us. tE xcellent price performance ratio tThe quickest processing time - DAkkS standard service: 4 working days - DAkkS express service: 48 hrs (new weights) tThe most modern calibration methods with robot controlled comparators allow the most accurate calibration results and fastest throughput time tKERN DAkkS calibration certificates are internationally recognised tA calibration service which is independent of the brand tKERN also reconditions existing customer weights (e.g. cleaning or readjustment) tOn request, we can also provide a pick-up and collection service with our parcel service G1-123-D-K-19408-01-00-2014-05 Standard weights The advantages of using the KERN on-site calibration Material / angenommene Dichte: Material / assumed density Nennwert Dichte Unsicherheit Material Form nominal value density uncertainty material shape 1 mg - 500 mg 7950 kg/m³ 140 kg/m³ 1 g - 1 kg 8000 kg/m³ 100 kg/m³ Edelstahl Draht Stainless steel Wire Edelstahl Knopf Stainless steel Cylindrical form We visit you. We would be pleased to visit you within Germany and carry out the calibration of your reference standards to OIML classes M1 – M3, 10 kg, 20 kg, 25 kg, 40 kg, 50 kg with permissible error limits, using our mobile MACOS system. Minimized downtime of your checking equipment and direct contact with our expert are the major benefits of this service. Price on request. Messergebnisse: Measurement results: Nennwert Kennzeichnung konventioneller Wägewert Unsicherheit k=2 Fehlergrenze nominal value marking conventional mass uncertainty max. perm. error 1 2 2 5 10 20 20 50 100 200 200 500 1 2 2 5 10 20 20 50 100 200 200 500 1 mg mg mg mg mg mg mg mg mg mg mg mg g g g g g g g g g g g g kg * * * * * * 1 2 2 5 10 20 20 50 100 200 200 500 1 2 2 5 10 20 20 50 100 200 200 500 1 mg mg mg mg mg mg mg mg mg mg mg mg g g g g g g g g g g g g kg + 0,0010 + 0,0005 + 0,0016 + 0,0010 + 0,0009 - 0,001 + 0,001 + 0,001 + 0,001 + 0,002 + 0,003 + 0,005 + 0,002 + 0,002 + 0,002 + 0,010 - 0,007 + 0,005 + 0,015 + 0,02 + 0,01 + 0,05 - 0,00 + 0,10 + 0,1 mg mg mg mg mg mg mg mg mg mg mg mg mg mg mg mg mg mg mg mg mg mg mg mg mg 0,0020 mg 0,0020 mg 0,0020 mg 0,0020 mg 0,0020 mg 0,003 mg 0,003 mg 0,004 mg 0,005 mg 0,006 mg 0,006 mg 0,008 mg 0,010 mg 0,013 mg 0,013 mg 0,016 mg 0,020 mg 0,026 mg 0,026 mg 0,03 mg 0,05 mg 0,10 mg 0,10 mg 0,26 mg 0,5 mg ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± 0,0060 mg 0,0060 mg 0,0060 mg 0,0060 mg 0,0080 mg 0,010 mg 0,010 mg 0,012 mg 0,016 mg 0,020 mg 0,020 mg 0,025 mg 0,030 mg 0,040 mg 0,040 mg 0,050 mg 0,060 mg 0,080 mg 0,080 mg 0,10 mg 0,16 mg 0,30 mg 0,30 mg 0,80 mg 1,6 mg Klasse* class* E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 E2 DAkkS calibration certificate for test weights (extract) For more details on our calibration service and other useful information, please see the internet on www.kern-lab.com 18 Recalibration tThe recalibration schedule depends on the frequency of use, the conditions of use and the safety requirements. tIn terms of standardisation, no particular recalibration interval is specified. tWe would recommend that you recalibrate your test weights every 6 months if they are used intensively, and every 12 months with normal use. tWe would be pleased to monitor your recalibration schedule. Official document Item to be calibrated Traceability, see page 216 Identification/Applicant Environmental conditions Metrological component Conventional mass Measuring uncertainty, see page 215 Note: For more information on this subject, please see our KERN DAkkS calibration service brochure – just request your free copy. Imlab Oude Vijvers 1 3370 Boutersem Tel.: +32(0)16 73 55 72 Fax: +32(0)16 73 55 87 info@imlab.be www.imlab.be Recalibration price of test weights (DAkkS calibration) Class acc. OIML R111-2004 E1 with volume determination Nominal value KERN 1 mg 2 mg 5 mg 10 mg 20 mg 50 mg 100 mg 200 mg 500 mg 1g 2g 5g 10 g 20 g 50 g 100 g 200 g 500 g 1 kg 2 kg 5 kg 10 kg 20 kg 50 kg 100 kg 200 kg 500 kg 1000 kg 2000 kg 1 mg – 500 mg 1 mg – 50 g 1 mg – 100 g 1 mg – 200 g 1 mg – 500 g 1 mg – 1 kg 1 mg – 2 kg 1 mg – 5 kg 1 mg – 10 kg 1 g – 50 g 1 g – 100 g 1 g – 200 g 1 g – 500 g 1 g – 1 kg 1 g – 2 kg 1 g – 5 kg 1 g – 10 kg – – – – – – – – – 963-231 963-232 963-233 963-234 963-235 963-236 963-237 963-238 963-239 963-241 963-242 963-243 963-244 963-245 963-246 – – – – – – 963-201 963-202 963-203 963-204 963-205 963-206 963-207 963-208 963-215 963-216 963-217 963-218 963-219 963-220 963-221 963-222 Price € excl. of VAT ex works – – – – – – – – – 193,193,193,193,193,193,193,193,193,193,465,465,465,1160,1360,– – – – – – 1070,1170,1350,1440,1530,2000,2450,2900,770,860,1040,1130,1230,1780,2230,2690,- KERN 962-251R 962-252R 962-253R 962-254R 962-255R 962-256R 962-257R 962-258R 962-259R 962-231R 962-232R 962-233R 962-234R 962-235R 962-236R 962-237R 962-238R 962-239R 962-241R 962-242R 962-243R 962-244R 962-245R 962-246R – – – – – 962-250R 962-201R 962-202R 962-203R 962-204R 962-205R 962-206R 962-207R 962-208R 962-215R 962-216R 962-217R 962-218R 962-219R 962-220R 962-221R 962-222R Price € excl. of VAT ex works 52,52,52,52,52,52,52,52,52,52,52,52,52,52,52,52,52,52,52,64,64,64,590,660,– – – – – 350,560,580,630,660,700,750,770,800,245,270,320,350,375,425,450,485,- Additional costs for preparation, overhaul and adjustment before the calibration Preparation of weights (e.g. cleaning, etc.) Single weight Weight set Subsequent services are carried out aer confirmation Continued overhaul of weights (e.g. wet-cleaning, markings, repair, special packaging, adjustment E1 (DAkkS only), E2 ...) Adjustment, per weight only available for weights with adjustment chamber (F1 – M3) Second calibration aer adjustment or substitution, per weight Class E1 Class E1 incl. volume determination Class E2 Class F1/F2 Class M1 – M3 Testing of magnetic properties according to OIML R111-2004, per weight Calibration of NON-OIML test weights, additional price per weight Imlab Oude Vijvers 1 3370 Boutersem E2 E1 without volume determination F1/F2 * F2 only KERN 962-351R 962-352R 962-353R 962-354R 962-355R 962-356R 962-357R 962-358R 962-359R 962-331R 962-332R 962-333R 962-334R 962-335R 962-336R 962-337R 962-338R 962-339R 962-341R 962-342R 962-343R 962-344R 962-345R 962-346R – – – – – 962-350R 962-301R 962-302R 962-303R 962-304R 962-305R 962-306R 962-307R 962-308R 962-315R 962-316R 962-317R 962-318R 962-319R 962-320R 962-321R 962-322R KERN Price € excl. of VAT ex works 26,26,26,26,26,26,26,26,26,26,26,26,26,26,26,33,33,33,33,41,41,41,52,64,– – – – – 190,315,340,385,410,435,495,530,560,127,150,196,220,245,305,340,370,- Price € excl. of VAT ex works 969-001R 969-002R 3,16,- 969-005R T&M basis 969-010R 12,- 969-210R 969-211R 969-310R 969-410R 969-610R 40,80,14,14,14,- 972-000 12,- – 8,- Tel.: +32(0)16 73 55 72 Fax: +32(0)16 73 55 87 Price € excl. of VAT ex works 962-451R 18,962-452R 18,962-453R 18,962-454R 18,962-455R 18,962-456R 18,962-457R 18,962-458R 18,962-459R 18,962-431R 18,962-432R 18,962-433R 18,962-434R 18,962-435R 18,962-436R 18,962-437R 20,962-438R 20,962-439R 20,962-441R 20,962-442R 25,962-443R 25,962-444R 25,962-445R 28,962-446R 39, 962-591R* 116,962-592R* 116,962-593R* 116,– – – – 962-450R 100,962-401R 167,962-402R 178,962-403R 199,962-404R 210,962-405R 220,962-406R 250,962-407R 265,962-408R 285,962-415R 67,962-416R 77,962-417R 98,962-418R 109,962-419R 119,962-420R 151,962-421R 166,962-422R 182,- KERN M1/M2/M3 Price € excl. of VAT ex works KERN 962-651R 962-652R 962-653R 962-654R 962-655R 962-656R 962-657R 962-658R 962-659R 962-631R 962-632R 962-633R 962-634R 962-635R 962-636R 962-637R 962-638R 962-639R 962-641R 962-642R 962-643R 962-644R 962-645R 962-646R 962-691R 962-692R 962-693R 962-694R 962-695R 962-650R 962-601R 962-602R 962-603R 962-604R 962-605R 962-606R 962-607R 962-608R 962-615R 962-616R 962-617R 962-618R 962-619R 962-620R 962-621R 962-622R 15,15,15,15,15,15,15,15,15,15,15,15,15,15,15,16,16,16,16,17,17,17,22,24,63,63,63,136,250,63,106,112,125,131,137,152,160,167,42,49,61,68,74,89,96,104,- KERN DAkkS Express Service 4 working days DAkkS standard service Class E2 – M3 DAkkS standard service Class E1, 1 mg – 500 mg, and recalibration 1 g –10 kg with a known volume Class E1, 1 g – 2 kg, incl. volume determination (new weights) 10 working days 15 working days Class E1, ≥ 2 kg, incl. volume determination (new weights) 15 working days DAkkS Express service in 48 hours except for class E1 tUrgent order is received at KERN by 12:00 noon at the latest tReady for shipping at KERN within two working days, at 12:00 noon tReturn by standard parcel service or express shipping (Costs and processing time on request) tAdditional cost for DAkkS Express Service, for each KERN test weight KERN KERN 962-115 € 20,– tFor Express shipping, see page 209 info@imlab.be www.imlab.be 18 Verification prices for test weights Class acc. OIML R111-2004 E2 with verification certificate Nominal value KERN 1 mg 2 mg 5 mg 10 mg 20 mg 50 mg 100 mg 200 mg 500 mg 1g 2g 5g 10 g 20 g 50 g 100 g 200 g 500 g 1 kg 2 kg 5 kg 10 kg 20 kg 50 kg 1 mg – 500 mg 1 mg – 50 g 1 mg – 100 g 1 mg – 200 g 1 mg – 500 g 1 mg – 1 kg 1 mg – 2 kg 1 mg – 5 kg 1 mg – 10 kg 1 g – 50 g 1 g – 100 g 1 g – 200 g 1 g – 500 g 1 g – 1 kg 1 g – 2 kg 1 g – 5 kg 1 g – 10 kg Price excl. of VAT ex works € 40,40,40,40,40,40,40,40,40,40,40,40,40,40,40,45,45,45,45,51,51,51,59,67,200,330,360,405,430,455,520,560,590,133,157,205,235,255,320,355,390,- 952-351 952-352 952-353 952-354 952-355 952-356 952-357 952-358 952-359 952-331 952-332 952-333 952-334 952-335 952-336 952-337 952-338 952-339 952-341 952-342 952-343 952-344 952-345 952-346 952-350 952-301 952-302 952-303 952-304 952-305 952-306 952-307 952-308 952-315 952-316 952-317 952-318 952-319 952-320 952-321 952-322 F1/F2 with verification certificate KERN 952-451 952-452 952-453 952-454 952-455 952-456 952-457 952-458 952-459 952-431 952-432 952-433 952-434 952-435 952-436 952-437 952-438 952-439 952-441 952-442 952-443 952-444 952-445 952-446 952-450 952-401 952-402 952-403 952-404 952-405 952-406 952-407 952-408 952-415 952-416 952-417 952-418 952-419 952-420 952-421 952-422 Price excl. of VAT ex works € 35,35,35,35,35,35,35,35,35,35,35,35,35,35,35,35,36,36,36,40,40,40,42,50,105,175,187,210,220,230,260,280,300,76,81,103,114,125,158,174,191,- M1 with verification certificate KERN 952-651 952-652 952-653 952-654 952-655 952-656 952-657 952-658 952-659 952-631 952-632 952-633 952-634 952-635 952-636 952-637 952-638 952-639 952-641 952-642 952-643 952-644 952-645 952-646 952-650 952-601 952-602 952-603 952-604 952-605 952-606 952-607 952-608 952-615 952-616 952-617 952-618 952-619 952-620 952-621 952-622 Price excl. of VAT ex works € 24,24,24,24,24,24,24,24,24,24,24,24,24,24,24,24,24,24,24,25,25,32,36,37,66,111,117,131,137,144,159,168,175,50,54,64,71,78,93,101,109,- KERN verification delivery time Standard verification service Class E2 – M1 Additional costs for preparation, overhaul and adjustment before the verification 6 working days Price excl. of VAT ex works € KERN Preparation of weights (e.g. cleaning, etc.) Single weight 969-008R 3,- Weight set 969-009R 16,- Subsequent services are carried out aer confirmation Continued overhaul of weights (e.g. wet-cleaning, markings, 969-005R repair, special packaging, adjustment E2 ...) Adjustment, per weight only available for weights with adjustment chamber (F1/F2 – M1) 969-010R T&M basis 12,- Verification aer adjustment or substitution, per weight Class E2 969-310R 14,- Class F1/F2 969-410R 14,- Class M1/M3 969-610R 14,- Verification prices for electronic balances (electronic crane scales, see page 213) Initial verification Checking equipment KERN 965-201 965-202 965-216 965-217 965-218 965-227 965-228 965-229 965-230 965-231 965-232 Electronic balances, class I, [Max] ≤ 5 kg 1) Electronic balances, class I, [Max] > 5 kg 1) Electronic balances, class II, [Max] ≤ 5 kg 1) Electronic balances, class II, [Max] > 5 kg – 50 kg 1) Electronic balances, class II, [Max] > 50 kg – 350 kg 1) Electronic balances, class III–IV, [Max] ≤ 5 kg 1) Electronic balances, class III–IV, [Max] > 5 kg – 50 kg 1) Electronic balances, class III–IV, [Max] > 50 kg – 350 kg 1) Electronic balances, class III–IV, [Max] > 350 kg – 1500 kg 1) Electronic balances, class III–IV, [Max] > 1500 kg – 2900 kg 1) Electronic balances, class III–IV, [Max] > 2900 kg – 6000 kg 1) 1) processing time 4 working days, 2) Price excl. of VAT ex works € 110,110,66,77,110,55,55,93,132,220,320,- Subsequent verification KERN 950-101R 950-102R 950-116R 950-117R 950-118R 950-127R 950-128R 950-129R 950-130R 950-131R 950-132R Price excl. of VAT ex works € 180,230,90,110,170,86,86,138,200,280,430,- processing time 15 working days 18 Imlab Oude Vijvers 1 3370 Boutersem Tel.: +32(0)16 73 55 72 Fax: +32(0)16 73 55 87 info@imlab.be www.imlab.be Verification prices for electronic crane scales Initial verification Checking equipment KERN 950-129H 950-130H 950-131H 950-132H 950-133H – – Electronic crane scales, class III–IV, [Max] > 50 kg – 350 kg 1) Electronic crane scales, class III–IV, [Max] > 350 kg – 1500 kg 1) Electronic crane scales, class III–IV, [Max] > 1500 kg – 2900 kg 1) Electronic crane scales, class III–IV, [Max] > 2900 kg – 6000 kg 1) Electronic crane scales, class III–IV, [Max] > 6000 kg – 12000 kg 1) Electronic crane scales, class III–IV, [Max] > 12000 kg – 31000 kg 2) Electronic crane scales, class III–IV, [Max] > 31000 kg – 50000 kg 2) 1) processing time 4 working days, 2) Price excl. of VAT ex works € 105,200,270,500,700,– – Subsequent verification KERN 950-129HR 950-130HR 950-131HR 950-132HR 950-133HR 950-134HR 950-135HR Price excl. of VAT ex works € 150,250,360,550,870,1060,1060,- processing time 15 working days Factory calibration certificates (ISO calibration) Mechanical hanging scales, prices for initial calibration and recalibration Checking equipment Initial calibration Recalibration KERN 961-100 961-101 961-102 961-103 961-104 961-105 961-106 KERN 961-100R 961-101R 961-102R 961-103R 961-104R 961-105R 961-106R Initial calibration Recalibration Tensile force Tensile force Mechanical hanging scales (spring scales) [Max] ≤ 5 kg Mechanical hanging scales [Max] > 5 kg – 50 kg Mechanical hanging scales [Max] > 50 kg – 350 kg Mechanical hanging scales [Max] > 350 kg – 1500 kg Mechanical hanging scales [Max] > 1500 kg – 3000 kg Mechanical hanging scales [Max] > 3000 kg – 6000 kg Mechanical hanging scales [Max] > 6000 kg – 12000 kg Price excl. of VAT ex works € 72,88,105,165,220,440,500,- Force gauges, tensile force, prices for initial calibration and recalibration Checking equipment Force gauges [Max] 300 N, 400 N, 500 N (DAkkS Calibration) Force gauges [Max] ≤ 500 N Force gauges [Max] > 500 N – 2 kN Force gauges [Max] > 2 kN – 10 kN Force gauges [Max] > 10 kN – 20 kN Force gauges [Max] > 20 kN – 50 kN Force gauges [Max] > 50 kN – 120 kN KERN KERN 963-161 961-161 961-162 961-163 961-164 961-165 961-166 963-161R 961-161R 961-162R 961-163R 961-164R 961-165R 961-166R Price excl. of VAT ex works € 250,135,165,225,350,520,940,- Force gauges, compression force, prices for initial calibration and recalibration Checking equipment Initial calibration Recalibration Compression force Compression force KERN 961-261 961-262 961-263 KERN 961-261R 961-262R 961-263R Price excl. of VAT ex works € 135,165,225,- Initial calibration Tensile force/ Compression force KERN 961-361 961-362 961-363 Recalibration Tensile force/ Compression force KERN 961-361R 961-362R 961-363R Price excl. of VAT ex works € 245,300,405,- Initial calibration Recalibration KERN 961-131 961-110 961-112 961-113 KERN 961-131R 961-110R 961-112R 961-113R Price excl. of VAT ex works € 120,120,170,120,- Force gauges [Max] > 50 N – 500 N Force gauges [Max] > 500 N – 2 kN Force gauges [Max] > 2 kN – 5 kN Force gauges, tensile and compression force, prices for initial calibration and recalibration Checking equipment Force gauges [Max] > 50 N – 500 N Force gauges [Max] > 500 N – 2 kN Force gauges [Max] > 2 kN – 5 kN Measuring instruments, prices for initial calibration and recalibration Checking equipment Hardness testing devices in accordance with Leeb tests (Type D) Coating thickness gauges 0 μm – 2000 μm (Ferro or NonFerro) Coating thickness gauges 0 μm – 2000 μm (Ferro and NonFerro) Ultrasonic material thickness testing devices 25 mm – 300 mm Imlab Oude Vijvers 1 3370 Boutersem Tel.: +32(0)16 73 55 72 Fax: +32(0)16 73 55 87 info@imlab.be www.imlab.be 18