Windows - CAN-BEST
Transcription
Windows - CAN-BEST
Performance Evaluation of Windows By: Elie Alkhoury, M.Eng. (Building Science), P.Eng. November 2005 © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory This Presentation We will discuss: • Window Standards • Laboratory Testing • Field Testing © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory This Presentation • Window Standards • Laboratory Testing • Field Testing © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory CSA A440 Family of Standards • A440-00 “Windows” – A440.1 “Users Guide • A440.2 “Window Thermal Performance” – A440.3 “Users Guide • A440.4 “Window Installation” © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory CSA A440-00 Main Sections are: • Material Specifications • Preservatives & Coatings • Component Specifications • Design Specifications © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory CSA A440-00 (Cont’d.) • • • • Glazing Methods Performance Requirements Test Methods Test Specimens © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory Performance Requirements • • • • • • • Ease of Operation Air Tightness Water Tightness Wind Load Resistance Forced Entry Resistance Condensation Resistance Mechanical Tests © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory Ease of Operation Measure of forces required to operate window sash or locks: • Initiate motion • Maintain motion © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory Air Tightness Rate of air infiltration and exfiltration in m3/hr.m at 75 Pa, ASTM E283 • A1: 2.79 • A2: 1.65 • A3: 0.55 • Fixed: 0.25 © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory Copyright, 2003 © CAN-BEST © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory Copyright, 2003 © CAN-BEST © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory Water Tightness Visual inspection for leakage under cyclic pressure application, ASTM E547 • Four cycles of 5 min ON, 1 min OFF • B1 to B7 (150 to 700 Pa) © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory Copyright, 2003 © CAN-BEST © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory Copyright, 2003 © CAN-BEST © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory Wind Load Resistance (Deflection) Uniformly distributed load, ASTM E330 • Sash L/125, Mullion L/175 • C1 to C5 (±500 to 2000 Pa) © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory Wind Load Resistance (Blow Out) Uniformly distributed load, ASTM E330 • No permanent damage • C1 to C5 (±1500 to 5000 Pa) © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory Forced Entry Resistance Levels F10 & F20 Grade 10 & 20 ASTM F548 • Dismantling from exterior • Hand and tool manipulation • Hardware load tests • Repeat hand and tool manipulation © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory Copyright, 2003 © CAN-BEST © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory Condensation Resistance Temperature Index (I), the lower of: • Coldest frame surface temperature • Coldest average of three glass temperatures @ 50 mm from sightline • 90 - Temperature Index @ -30/+20 °C • 98 - Temperature Factor @ -18/+21 °C • 00 - Temperature Index @ -30/+20 °C © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory Copyright, 2003 © CAN-BEST © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory Weather Side Room Side Copyright, 2003 © CAN-BEST Test Wall © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory Copyright, 2003 © CAN-BEST © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory Mechanical Tests • Screen Strength – Standard Duty,60 N (13.5 lb) – Heavy Duty, 330 N (75 lb) • Blocked Operation (Sliding) • Sash Strength (Projecting) • Sash Pull Off (PVC, FRP) © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory Copyright, 2003 © CAN-BEST © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory This Presentation • Window Standards • Laboratory Testing • Field Testing © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory Common Field Tests: • Air Tightness • Water Tightness • Wind Load Resistance © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory Copyright, 2003 © CAN-BEST © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory Copyright, 2003 © CAN-BEST © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory Copyright, 2003 © CAN-BEST © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory Copyright, 2003 © CAN-BEST © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory Copyright, 2003 © CAN-BEST © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory Copyright, 2003 © CAN-BEST © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory Copyright, 2003 © CAN-BEST © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory Why Windows Continue to Leak? • Standards are for Standard Products • Specifications need to be Job-Specific • Inspectors need guidelines © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory More Info © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory Regular Contributing Writer to the Industry © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory Thank You © CAN-BEST 2005 Canadian Building Envelope Science and Technology SCC & AAMA Accredited Laboratory