FLAMEBLOCKER NKOXSekw 0,6/1kV - TELE

Transcription

FLAMEBLOCKER NKOXSekw 0,6/1kV - TELE
FLAMEBLOCKER
NKOXSekw 0,6/1kV
IEC 60092-353
Halogen-free shipboard power cables
with cross-linked polyethylene insulation
and halogen-free sheath, with screen
CONSTRUCTION
Conductors:
Insulation:
Inner covering:
Screen (armour):
Sheath:
Colour of sheath:
Core identification:
1-core:
2-core:
3-core:
4-core:
5 and more:
-circular stranded bare or tinned copper class 2 1 to 6mm2
- circular compacted stranded bare or tinned copper class 2 10 to 300 mm2
- circular stranded bare or tinned copper class 5
- sector shaped 35 to 300 mm2
acc. to IEC 60228
cross-linked polyethylene HF XLPE 90oC, > 35 mm2 cross-linked polyolefin
compound HF 90 acc. to IEC 60092-351
- special flame-retardant, halogen-free compound for cables up to 16 mm2,
- tape bedding and special flame-retardant, halogen-free compound
for cables 25 mm2 and above - circular compacted stranded conductor,
- tape bedding for cables 35mm2 and above - sector shaped conductor
copper wire braiding
thermoplastic halogen- free polyolefin compound type SHF1 acc. to IEC 60092-359
black or grey
NKOXSekw
not specified
black, blue
black, blue, brown
blue, brown, black, grey
white with black numbering
NKOXSekw żo
green-yellow
green-yellow, black, blue
green-yellow, black, blue, brown
green-yellow, others cores white with black numbering
or acc. to HD 308 S2:
2-core:
blue, brown
3-core:
brown, black, grey
4-core:
blue, brown, black, grey
5-core:
blue, brown, black, grey, black
green-yellow, blue, brown
green-yellow, brown, black, grey
green-yellow, blue, brown, black, grey
Other suitable colour codes may be used
Other suitable colour codes may be used
TELE-FONIKA Kable Sp. z o.o. S.K.A.
www.tfkable.com
FLAMEBLOCKER
NKOXSekw 0,6/1kV
IEC 60092-353
CHARACTERISTIC
Maximum conductor operating temperature:
Lowest ambient temperature for fixed installation:
Lowest installation temperature:
Maximum short-circuit conductor temperature:
Minimum bending radius:
+90oC
-40oC
-15oC
+250oC
6 x D (D is the overall diameter of the cable)
FIRE PERFORMANCE



Flame retardant:
Smoke emission:
Gases evolved during combustion:
IEC 60332-3-22 Category A
IEC 61034-2
IEC 60754-1: < 0,5% acid gas
IEC 60754-2: pH  4,3; conductivity  10 Smm-1
APPLICATIONS
for fixed installations in all areas and open deck in ships.
Cables with class 5 conductors are produced on request.
Standard length cable packing
1000m on drums. Other forms of packing and delivery are available on request
APPROVALS
PRS, GL, DNV, LR, ABS, RINA, CLASSNK, BV
Number and cross-sectional area of
conductor
n x mm
1x1
1x1,5
1x2,5
1x4
1x6
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
2
Cables with conductor class 2
Cables with conductor class 5
Overall diameter
Net weight of cables
Overall diameter
Net weight of cables
mm
kg/km
mm
kg/km
6,3
6,6
7,0
7,7
8,3
9,0
10,2
11,9
13,6
15,3
17,0
19,2
20,8
23,0
25,1
28,0
30,2
64
76
88
115
137
183
254
364
503
664
880
1165
1425
1740
2146
2705
3330
6,2
6,5
7,0
7,7
8,2
9,2
10,5
12,1
13,4
15,8
18,0
20,3
21,6
24,0
26,9
28,8
32,8
63
74
87
111
132
181
250
351
484
671
900
1143
1384
1704
2069
2621
3236
TELE-FONIKA Kable Sp. z o.o. S.K.A.
www.tfkable.com
FLAMEBLOCKER
NKOXSekw 0,6/1kV
IEC 60092-353
Number and cross-sectional
area of conductor
Cables with conductor class 2
Cables with sector shaped
Cables with conductor class 5
Overall
diameter
mm
Net weight
of cables
kg/km
Overall
diameter
mm
Net weight
of cables
kg/km
Overall
diameter
mm
Net weight
of cables
kg/km
2x1
2x1,5
2x2,5
2x4
2x6
2x10
2x16
2x25
2x35
2x50
9,1
9,7
10,8
11,8
13,5
15,0
17,2
20,9
23,2
26,6
131
154
191
241
345
462
638
844
1085
1447
-
-
9,0
9,6
10,8
11,7
13,5
15,3
17,8
21,2
22,9
27,7
127
145
187
233
335
461
640
821
1045
1477
3x1
3x1,5
3x2,5
3x4
3x6
3x10
3x16
3x25
3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
9,6
10,4
11,3
12,4
14,2
16,0
18,2
22,3
24,8
28,4
32,3
37,1
41,1
45,9
50,4
56,6
144
176
222
287
402
560
778
1105
1442
1933
2655
3580
4441
5447
6716
8553
21,0
23,7
27,6
30,7
34,5
38,4
42,6
47,5
1264
1708
2382
3175
4056
4977
6165
7926
9,4
10,2
11,3
12,3
14,1
16,3
18,8
22,7
24,5
29,6
34,5
39,6
42,9
48,2
54,2
58,2
139
170
216
276
387
553
772
1069
1360
1965
2684
3534
4386
5419
6566
8265
4x1
4x1,5
4x2,5
4x4
4x6
4x10
4x16
4x25
4x35
4x50
4x70
4x95
4x120
10,4
11,1
12,2
14,0
15,4
17,3
20,0
24,6
27,3
31,3
36,1
41,2
45,5
171
204
261
377
488
683
966
1399
1816
2452
3474
4635
5746
23,8
27,0
31,3
35,5
39,5
1641
2238
3115
4270
5312
10,3
11
12,2
13,9
15,3
17,7
20,7
25,0
26,9
32,7
38,5
44,0
47,5
166
197
253
362
468
673
956
1358
1740
2514
3553
4558
5649
n x mm
2
TELE-FONIKA Kable Sp. z o.o. S.K.A.
www.tfkable.com
FLAMEBLOCKER
NKOXSekw 0,6/1kV
IEC 60092-353
Number and cross-sectional
area of conductor
Cables with conductor class 2
Cables with sector shaped
Cables with conductor class 5
Overall
diameter
mm
Net weight
of cables
kg/km
Overall
diameter
mm
Net weight
of cables
kg/km
Overall
diameter
mm
Net weight
of cables
kg/km
4x150
4x185
4x240
50,9
55,9
62,8
7054
8691
11110
43,8
48,4
54,1
6529
8084
10383
53,4
60,1
64,6
6961
8487
10721
5x1
5x1,5
5x2,5
5x4
5x6
5x10
5x16
5x25
5x35
5x50
5x70
11,2
12,0
13,8
15,2
16,9
19,0
21,9
26,8
30,1
34,7
39,7
200
240
346
454
580
818
1167
1690
2237
3042
4288
29,1
34,0
2749
3916
11,0
11,8
13,7
15,0
16,8
19,4
22,8
27,3
29,7
36,2
42,4
192
225
336
436
555
806
1172
1628
2146
3115
4379
6x1,5
6x2,5
13,5
14,8
314
407
-
-
13,3
14,7
303
395
7x1
7x1,5
7x2,5
12,0
13,5
14,8
233
322
421
-
-
11,8
13,3
14,7
220
310
407
8x1,5
14,2
346
-
-
14,0
333
9x1,5
15,3
407
-
-
15,1
391
10x1
10x1,5
10x2,5
15,3
16,6
18,6
364
437
582
-
-
15,0
16,4
18,5
351
420
563
12x1
12x1,5
12x2,5
14x1,5
15,9
17,1
19,1
17,9
398
491
638
534
-
-
15,6
16,8
19,0
17,6
384
454
615
511
16x1
16x1,5
16x2,5
17,3
18,9
20,9
484
592
789
-
-
17,0
18,6
20,9
449
565
760
19x1
19x1,5
19x2,5
18,2
19,8
22,2
527
667
904
-
-
17,8
19,5
22,1
506
620
868
20x1
20x1,5
19,2
20,7
562
701
-
-
18,7
20,4
539
669
n x mm
2
TELE-FONIKA Kable Sp. z o.o. S.K.A.
www.tfkable.com
FLAMEBLOCKER
NKOXSekw 0,6/1kV
IEC 60092-353
Number and cross-sectional
area of conductor
Cables with conductor class 2
Cables with sector shaped
Cables with conductor class 5
Overall
diameter
mm
Net weight
of cables
kg/km
Overall
diameter
mm
Net weight
of cables
kg/km
Overall
diameter
mm
Net weight
of cables
kg/km
20x2,5
23,2
951
-
-
23,1
913
24x1
24x1,5
24x2,5
21,0
23,0
25,7
651
824
1127
-
-
20,5
22,6
25,7
624
786
1082
27x1
27x1,5
27x2,5
21,6
23,4
26,3
702
880
1212
-
-
21,1
23,0
26,2
672
837
1162
30x1
30x1,5
30x2,5
22,3
24,4
27,3
765
954
1316
-
-
21,8
24,0
27,3
716
907
1261
37x1
37x1,5
37x2,5
23,9
26,1
29,3
873
1125
1558
-
-
23,3
25,7
29,3
833
1068
1490
n x mm
2
TELE-FONIKA Kable Sp. z o.o. S.K.A.
www.tfkable.com
FLAMEBLOCKER
NKOXSekw 0,6/1kV
IEC 60092-353
Electrical data
Conductor class 2
Bare copper
Conductor class 5
Tinned copper
Maximum
resistance
at 90C
Maximum
resistance
at 20C
Maximum
resistance
at 90C
Bare copper
Maximum
resistance
at 20
Cross-section
of conductor
Maximum
resistance
at 20
R20
R90
R20
R90
R20
R90
R20
mm2
1
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
R90
Ω/km
18,1
12,1
7,41
4,61
3,08
1,83
1,15
0,727
0,524
0,387
0,268
0,193
0,153
0,124
0,0991
0,0754
0,0601
Ω/km
23,1
15,4
9,45
5,88
3,93
2,33
1,47
0,927
0,668
0,493
0,342
0,249
0,195
0,158
0,1264
0,0961
0,0766
Ω/km
18,2
12,2
7,56
4,70
3,11
1,84
1,16
0,734
0,529
0,391
0,270
0,195
0,154
0,126
0,100
0,0762
0,0607
Ω/km
23,2
15,6
9,64
5,99
3,97
2,35
1,48
0,936
0,675
0,499
0,344
0,249
0,196
0,161
0,128
0,0972
0,0774
Ω/km
19,5
13,3
7,98
4,95
3,30
1,91
1,21
0,78
0,554
0,386
0,272
0,206
0,161
0,129
0,106
0,0801
0,0641
Ω/km
24,9
17,0
10,2
6,3
4,2
2,4
1,5
0,995
0,706
0,492
0,347
0,263
0,205
0,164
0,135
0,1021
0,0817
Ω/km
20,0
13,7
8,21
5,09
3,39
1,95
1,24
0,795
0,565
0,393
0,277
0,210
0,164
0,132
0,108
0,0817
0,0654
Ω/km
25,5
17,5
10,47
6,49
4,32
2,49
1,58
1,014
0,720
0,501
0,353
0,268
0,209
0,168
0,138
0,1042
0,0834
TELE-FONIKA Kable Sp. z o.o. S.K.A.
www.tfkable.com
Maximum
resistance
at 90C
Tinned copper
Maximum
resistance
at 20
Maximum
resistance
at 90C
FLAMEBLOCKER
NKOXSekw 0,6/1kV
IEC 60092-353
Current ratings
Current ratings acc. to IEC 60092-352 based on ambient air temperature of 45ºC
Nominal crosssectional area
2
mm
1
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
Insulation class temperature 90C
1-core
2-cores
3-cores & 4-cores
A
18
23
40
51
52
72
96
127
157
196
242
293
339
389
444
522
601
A
15
20
26
34
44
61
82
108
133
167
206
249
288
331
377
444
511
A
13
16
21
28
36
50
67
89
110
137
169
205
237
272
311
365
421
Current ratings for more than 4-core cables:
Number of cores
Nominal cross-sectional area of
conductor
Current ratings
5
7
10
12
16
19
20
24
27
30
37
1mm2
1,5mm2
2,5mm2
A
10,5
9
8
8
7
7
7
6
6
6
5
A
12
10
9
9
8
7
7
6,5
6,5
6
6
A
16
15
13
12
11
10
10
9,5
9
9
8
TELE-FONIKA Kable Sp. z o.o. S.K.A.
www.tfkable.com
FLAMEBLOCKER
NKOXSekw 0,6/1kV
IEC 60092-353
Correction factors for different ambient air temperatures
The ambient temperature of 45ºC, on which the current ratings are based, is considered as a standard value for the
ambient air temperature, generally applicable for any kind of ship and for navigation in any climate.
Correction factors for various ambient air temperatures
Maximum conductor
temperature
Ambient temperature C
Correction factors
90C
35C
40C
45C
50C
55C
60C
65C
70C
75C
80C
1,10
1,05
1,00
0,94
0,88
0,82
0,74
0,67
0,58
0,47
Correction factors for cable grouping
Where more than six bunched cables on cable trays, in cable conduits, pipes or trunking are expected to operate
simultaneously full rated capacity, a correction factor of 0,85 should be applied.
All the information contained in this document - including tables and diagrams - is given in good faith and believed to be correct at
the time of publication. The information does not constitute a warranty nor representation for which TELE-FONIKA Kable assumes
legal responsibility. TELE-FONIKA Kable reserves rights to introduce changes to the document at any time.
TELE-FONIKA Kable Sp. z o.o. S.K.A.
www.tfkable.com