Zemax How to Include Detector Resolution in MTF Calculations WHITE PAPER
Transcription
Zemax How to Include Detector Resolution in MTF Calculations WHITE PAPER
WHITE PAPER How to Include Detector Resolution in MTF Calculations Zemax A Radiant Zemax Company WHITE PAPER How to Include Detector Resolution in MTF Calculations Introduction Modulation Transfer Function (MTF) is an important method of describing the performance of an optical system. A consequence of applying Fourier theory to image forming optical MTF is commonly used to describe the systems, MTF describes the contrast in the image of a spatial frequency presented in the performance of an imaging system, but scene being viewed. See this article for more information on what MTF is. the finite resolution of the detection system is often ignored. This white MTF describes the imaging of the system, but an important system parameter is usually paper describes how to account for neglected: the resolution of the detector. If the detector’s pixels are significantly bigger detector pixel sizes and position shifts than the resolvable spot size, the optical system is said to be detector limited, and the to give a full-system MTF measurement. overall system MTF is reduced compared to the MTF the optical system itself is capable of achieving. Experimentally, MTF can be measured by imaging a small bar (or single-frequency sine) chart through the lens and onto the detector. The bar chart must be small because the optical transfer function of the lens should not vary significantly over the target pattern. Within Zemax we can use the same method: the partially coherent image analysis feature is used to image a small bar chart through the system onto a pixellated detector, and the MTF is computed directly from this. An Example The example file used here can be downloaded via this link. It is a derivative of the Cooke triplet sample file: 2 I Zemax, LLC Zemax A Radiant Zemax Company WHITE PAPER We image a bar chart through the system: The full width of the image is 0.5 mm, and the optical performance of the lens does not vary significantly over this field of view: 3 I Zemax, LLC Zemax A Radiant Zemax Company WHITE PAPER We will now look at the cross-section of the Partially Coherent Image Analysis, configured like so: so we use 500 1µ-wide pixels to view our image. The resulting image is like so: 4 I Zemax, LLC Zemax A Radiant Zemax Company WHITE PAPER The cross section of the false color map is shown above. Note we have ten cycles of the bar pattern over about a 200µ region: this corresponds to 50 cycles/mm. The MTF can then be estimated by determining the maximum and minimum relative intensity across the cross section. To reduce the effects of edges, the analysis parameters should be set to provide at least 5 well defined peaks across the cross section. The MTF is computed by looking for the minimum and maximum intensity at all points between the second and second-to-last local peaks in the intensity data. By considering only data within these two peaks, the effects of the edges is somewhat reduced. The estimated MTF is then given by the usual computation of (Imax-Imin)/(Imax+Imin). Finally, note that if a bar target is used, the resulting MTF is the square-wave, not sinewave modulation: Note there is excellent agreement between the two analysis features, with an estimated MTF of 0.68 from both the Partially Coherent Image Analysis and the FFT MTF plot at 50 cycles/mm (note that we are only approximately at 50 cycles/mm in the Partially Coherent Image Analysis). This is to be expected, as the 1µ detector pixel size is smaller than the 5µ RMS spot size and 3.5µ Airy disk radius. This combination of optical system and detector is optics limited, not detector limited. 5 I Zemax, LLC Zemax A Radiant Zemax Company WHITE PAPER Instead, repeat the Partially Coherent Image Analysis, but use an array of 100 x 100 pixels each of 5µ width. Now the MTF is 0.43: The MTF is clearly degraded by the coarser detector resolution. Equally important, consider what happens if the detector is shifted in the image plane. Because the pixel size is close to the resolution limit, the measured MTF will be sensitive to shifts of the detector array on the order of one pixel. If we decenter the detector by a half-pixel in x... 6 I Zemax, LLC Zemax A Radiant Zemax Company WHITE PAPER ...the MTF improves to 0.59 because there is less cross-talk between light and dark regions of the image as they are integrated by the detector array: Summary If an optical system’s minimum resolvable spot is comparable to or less than the detector size, it is important to consider the effects of integrating the spatial signal on the detector array when computing MTF. The Partially Coherent Image Analysis feature provides this capability. 7 I Zemax, LLC Zemax A Radiant Zemax Company MTF is commonly used to describe the performance of an imaging system, but the finite resolution of the detection system is often ignored. This white paper describes how to account for detector pixel sizes and position shifts to give a full-system MTF measurement. Contact Us Today Americas and Worldwide Zemax, LLC 22908 NE Alder Crest Drive, Suite 100 Redmond, WA 98053 T. +1 425 298-2145 Europe Zemax Europe, Ltd. 8 Riverside Business Park, Stoney Common Road Stansted, CM24 8PL, UK T. +44 1279 810911 Greater China Zemax China, Ltd. B301 SOHO ZhongShan Plaza No.1065 West ZhongShan Road ChangNing District Shanghai 200051 T. +86 21 5242-2288 Zemax.com Zemax A Radiant Zemax Company sales@zemax.com © 2013 Radiant Zemax LLC. Radiant Zemax, ProMetric, TrueTest and Zemax are trademarks of Radiant Zemax LLC. All other marks are the property of their respective owners. 770-9004-01 1/13