SUBMITTAL COVER SHEET UNIT SUMMARY PROJECT NAME LOCATION
Transcription
SUBMITTAL COVER SHEET UNIT SUMMARY PROJECT NAME LOCATION
SUBMITTAL COVER SHEET PROJECT NAME LOCATION ARCHITECT ENGINEER CONTRACTOR SUBMITTED BY DATE UNIT SUMMARY Quantity Unit Designation Model No. Total Cooling Sensible Cooling Air Ent. Evaporator Air Lvg. Evaporator Heating Input Heating Output CFM/ESP EER/SEER Electrical Minimum Ampacity Min.-Max. Breaker Net Unit Weight Accessory Catalog Form Number ACCESSORIES: NOTES: PRINTED IN U.S.A 01/12 QG FORM NO. M11-1640 FORM NO. X33-1406 (-)ANL- SERIES – AIR CONDITIONERS EFFICIENCIES UP TO 14.5 SEER/12.5 EER NOMINAL SIZES 1.5-5 TONS [5.27-17.58 kW] JOB NAME UNIT MODEL NO. CONTRACTOR COIL MODEL NO. ENGINEER AIR HANDLER MODEL NO. SUBMITTED FOR APPROVAL RECORD DATE LOCATION ORDER NO. UNIT DATA FEATURES FOR (-)ANL- SERIES COOLING PERFORMANCE • This unit contains a special scroll compressor that is designed specifically to operate with R-410A refrigerants and polyolester (POE) oils. The compressor is hermetically sealed and incorporates internal high temperature motor overload protection and durable insulation on the motor windings. It is externally mounted on rubber grommets to reduce vibration and noise. • Compressors have an internal pressure relief assembly to protect against excessive pressure differential. • All refrigerant connections are on the exterior of the unit, located close to the ground for neat appearing installations. • Cabinet is constructed of powder painted galvanized steel. The full wraparound louvered grille protects the coil from damage. • Copper tube—aluminum fin coils are used on all models. • The control box is located in the top corner of the cabinet providing for easy access through a service panel. • Service valves are standard on all models. • Power and control wiring are kept separate. • Every unit is factory charged and tested. • Separate compressor compartment for easy service access. • Drawn, painted base pan for extra corrosion resistance and sound reduction. • Automatic reset high and low pressure controls are standard on all models. • A liquid line filter drier is standard on all models (shipped – not installed). Conditional Parts ............................................................................Ten (10) Years Compressor ....................................................................................Ten (10) Years EFFICIENCY .................................. _______ SEER TOTAL CAPACITY .................... _______ MBH [kW] SENSIBLE CAPACITY .............. _______ MBH [kW] OUTDOOR DESIGN TEMP. ........ _______ °F [°C] DB TEMP. OF AIR ENTERING EVAPORATOR COIL .............. _______ °F [°C] DB _______ °F [°C] WB SUPPLY AIR BLOWER PERFORMANCE TOTAL AIR SUPPLY .................. _______ CFM [L/s] TOTAL RESISTANCE EXTERNAL TO UNIT........................................ _______ IWC MOTOR RATING .......................... _______ HP [W] ELECTRICAL DATA POWER SUPPLY .......................... ___________ Hz MINIMUM WIRE SIZE ...................... _______ AWG FIELD INSTALLED ACCESSORIES MAXIMUM OVERCURRENT DEVICE FUSES/HACR BREAKER ............ _______ AMPS Low Ambient Control ........................................................................................ Compressor Time Delay Control ...................................................................... Hard Start Components .................................................................................... Compressor Crankcase Heater (CCH) .............................................................. CLEARANCES ACCESS SIDE 24" [609.6 mm] AIR INLETS 6" ABOVE UNIT 60" [1524 mm] [152 mm] 16.0 “Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your Contractor for details or visit www.energystar.gov.” DIMENSIONS Model Number (-)ANL018 024/031 037/043 Height “H” (Inches) [mm] 19 [483] 19 [483] 23 [584] Length “L” (Inches) [mm] 351/2 [902] 401/2 [1029] 443/8 [1127] Width “W” (Inches) [mm] 233/4 [603] 275/8 [702] 311/2 [800] 049 060 29 [737] 33 [838] 443/8 [1127] 443/8 [1127] 311/2 [800] 311/2 [800] [ ] Designates Metric Conversions AIR DISCHARGE ALLOW 60⬙ [1524 mm] CLEARANCE W L ACCESS PANEL H AIR INLETS (LOUVERS) ALLOW 6⬙ [152 mm] MIN. CLEARANCE 3 SIDES A-0 0001 ALLOW 24⬙ [610 mm] ACCESS CLEARANCE SPECIAL NOTES ON EQUIPMENT: Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices. RHEEM MANUFACTURING COMPANY 5600 Old Greenwood Road, Fort Smith, Arkansas 72908 “In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.” PRINTED IN U.S.A. 10-12 QG FORM NO. X33-1406 Supersedes Form No. X33-1220 Rev. 2