Development and Investigations of Novel Sample Preparation Techniques
Transcription
Development and Investigations of Novel Sample Preparation Techniques
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology 54 Development and Investigations of Novel Sample Preparation Techniques Electrochemical Extraction and Evaluation of Miniaturized Analytical Devices Coupled to Mass Spectrometry GUSTAV LILJEGREN ACTA UNIVERSITATIS UPSALIENSIS UPPSALA 2005 ISSN 1651-6214 ISBN 91-554-6256-1 urn:nbn:se:uu:diva-5807 ! " "##$ %&$ ' ( ' ' ) * + ,( * -.( /* "##$* 0( ' 1 2 ) 3* , , , ' 4 5 2* 5 * $* $ * * ISBN 67$$78"$87* '' ' * 0 7 7 + '' 3* 5 ' '( 4 ' 9 : 9)2: * ) + ' 7 92),: 7 92),:* ' ' ' ( ' 4( 47' 9);,: 3* + );, 4 ' ' '* 5 ( 7 + 9,: 2), + * < ( + ' '* ) ' + 4 '+ * '' + ( + ' + * 7 ( ' , + +=( '' 92: 3 * + ,72), ( * 0 7 ( ' 3 )2 + ( ( 4 9,20: 2* ' , '' ' %#> '+ ' #*$ ?-@* 7 ,@,2072 + (' ' ( + 7+ , * , 27 27 ) )47' ) , 4 !"# # $% &''# # ()*&+,# A / -.( "##$ 0221 8$78" 021 67$$78"$87 &&&& 7$B#C 9 &@@*=*@DE&&&& 7$B#C: List of Papers This thesis is based on the following papers, which are referred to in the text by their Roman numerals: I Marie-Louise Nilsson, Monica Waldebäck, Gustav Liljegren, Henrik Kylin and Karin E. Markides; Pressurized-fluid extraction (PFE) of chlorinated paraffins from the biodegradable fraction of source-separated household waste. Fresenius Journal of Analytical Chemistry, 2001, 370 (7), 913-918. II Gustav Liljegren, Jean Pettersson, Karin E. Markides and Leif Nyholm; Electrochemical Solid-Phase Microextraction of Anions and Cations using Polypyrrole Coatings and an Integrated ThreeElectrode Device. The Analyst, 2002, 127 (5), 591-597. III Gustav Liljegren and Leif Nyholm; Electrochemically Controlled Solid-Phase Extraction and Preconcentration using Polypyrrole Coated Microarray Electrodes in a Flow System. The Analyst, 2003, 128 (3), 232-236. IV Andreas Pettersson Dahlin, Magnus Wetterhall, Gustav Liljegren, Sara K. Bergström, Per Andrén, Leif Nyholm, Karin E. Markides and Jonas Bergquist; Capillary electrophoresis coupled to mass spectrometry from a polymer modified poly(dimethylsiloxane) microchip with an integrated graphite electrospray tip. The Analyst, 2005, 130 (2), 193 - 199. V Gustav Liljegren, Niklas Forsgard, Camilla Zettersten, Jean Pettersson, Malin Svedberg, Merja Herranen and Leif Nyholm; OnLine Electrochemically Controlled Solid-Phase Extraction Coupled to Electrospray and Inductively Coupled Plasma Mass Spectrometry. Manuscript. VI Gustav Liljegren, Andreas Dahlin, Camilla Zettersten, Jonas Bergquist and Leif Nyholm; On-line Coupling of a Microelectrode Array equipped Poly(dimethylsiloxane) Microchip with an Integrated Graphite Electrospray Emitter to Electrospray Ionisation Mass Spectrometry. Manuscript. Reprints were made with kind permission from the publishers. Author contribution Paper I: Wrote the first draft, performed all experiments, except the Soxtec extractions. Paper II: Wrote the paper, performed all experiments. Jean Pettersson took part in the ICP-MS measurements. Paper III: Wrote the paper, performed all experiments. Paper IV: Wrote part of the paper, performed all electrochemical experiments. Paper V: Wrote the paper, performed almost all experiments. Niklas Forsgard took part in the initial ICP-MS measurements and Camilla Zetterberg took part in the ESI-MS measurements. I took part in the SEM measurements, which was headed by Malin Svedberg, and the AFM measurements, which was headed by Merja Herranen. Paper VI: Wrote the major part of the paper, performed all experiments. Andreas Dahlin constructed the PDMS chip and Camilla Zettersten took part in the ESI-MS measurements. Contents 1. Introduction.................................................................................................7 2. Sample preparation techniques ...................................................................9 2.1 Pressurized-fluid extraction..................................................................9 2.2 Solid-phase microextraction...............................................................11 2.2.1 Electrochemically controlled solid-phase microextraction.........14 2.3 Solid-phase extraction in microflow systems.....................................15 2.3.1 Electrochemically controlled solid-phase extraction in microflow systems ...............................................................................16 3. Polypyrrole................................................................................................18 3.1 Polymerization and properties of polypyrrole....................................18 3.2 The role of polypyrrole in analytical chemistry .................................21 4. Miniaturization..........................................................................................23 4.1 Miniaturizing analytical devices ........................................................23 4.2 Use of electrodes in microflow channels............................................24 4.3 Microfabrication.................................................................................25 5. On-line coupling of electrochemical systems to mass spectrometry ........29 5.1 Electrospray ionization.......................................................................29 5.2 Sheathless electrospray ......................................................................30 5.3 On-line coupling of electrochemistry and electrospray mass spectrometry .............................................................................................32 5.4 Inductively coupled plasma mass spectrometry .................................34 5.5 On-line coupling of electrochemistry and inductively coupled plasma mass spectrometry........................................................................35 6. Concluding remarks and future aspects ....................................................37 7. Acknowledgements...................................................................................39 8. Summary in Swedish ................................................................................41 9. References.................................................................................................45 Abbreviations AdSV ASE ASV CV EC EMLC ESI ICP MS PDMS PFE PMMA PPy PPy(Br) PPy(ClO4) SPE SPME P-TAS Adsorptive Stripping Voltammetry Accelerated Solvent Extraction Anodic Stripping Voltammetry Cyclic Voltammetry Electrochemical Electrochemically Modulated Liquid Chromatography Electrospray Ionization Inductively Coupled Plasma Mass Spectrometry poly(dimethylsiloxane) Pressurized-Fluid Extraction Polymethyl methacrylate Polypyrrole Polypyrrole doped with bromide Polypyrrole doped with perchlorate Solid-Phase Extraction Solid-Phase Microextraction Micro Total Analysis Systems 1. Introduction In this thesis, large scale to small scale extraction and sample preparation techniques have been evaluated and developed. The aim has been to study the advantages of miniaturization with the aim to develop a sample preparation technique compatible with chip-based electroanalytical analysis systems or similar devices coupled on-line to mass spectrometric (MS) detection. An important part of the project has been to utilize modified electrode surfaces to increase the extraction efficiency of charged species in both static- and microfluidic systems. Pressurized-fluid extraction (PFE), employing highdiffusion liquids, and the extraction and preconcentration of charged species using electrochemically (EC) controlled solid-phase microextraction (SPME) are discussed. Electrochemical sample manipulation and EC controlled solid-phase extraction (SPE), employing different polypyrrole coated macro and microarray electrodes, have been performed in flow systems coupled on-line to different MS techniques. In addition, a microelectrode array equipped poly(dimethylsiloxane) (PDMS) microchip with a durable integrated graphite electrospray tip has been developed and successfully coupled on-line to electrospray ionization MS (ESI-MS). PFE, also known as accelerated solvent extraction (ASE), is a relatively new automated liquid extraction technique where extractions are performed at high temperatures and pressures. The technique has been developed in an effort to reduce the large solvent consumption, and long extraction times, needed in traditional liquid extraction techniques. In paper I, PFE was used to optimize the extraction conditions for chlorinated paraffins (CP) from a very complex matrix. In paper II, III and V, the effects of miniaturization on the extraction efficiencies were studied employing and comparing EC-SPME (II) with on-line EC-SPE using EC detection (III) and MS detection (V). The electrochemically controlled extractions were performed using different polypyrrole coatings. Polypyrrole is a conducting polymer that is easily polymerized on conducting surfaces, and the application of an electric potential to the polymer can be used to change its chemical and/or physical properties. The polymerization is performed electrochemically by applying a positive potential to an electrode in a monomer solution, also containing an appropriate electrolyte. By changing the electrolyte, it is possible to change the properties of the polymer and thus create different conducting phases that can be used for different analytical purposes such as separation, preconcentration and sens7 ing, in many types of analytical devices containing electrodes. The electroactivity and reversible electrochemical properties of the polymer enable both electrochemically controlled extraction and desorption of charged species, by simply changing the applied potential. In paper II, polypyrrole was used as an extraction medium in SPME, employing a new compact all-in-one electrode device. Another area of interest where sample preconcentration is often required in order to overcome detection limit problems, or to eliminate interferences, is in micro total analysis systems (P-TAS). Due to the flow channel designs of these microchip devices, on-chip SPE can be difficult to accomplish and such sample preparation steps are therefore often performed off chip. A solution to this problem is given in paper III, where polypyrrole coated microarray electrodes was used to perform preconcentrations in a miniaturized flow system. The efficiency and usefulness of polypyrrole as an extraction medium in on-line flow systems were also further evaluated in paper V using a thin-layer cell coupled on-line to different mass spectrometric detection techniques. In paper IV and VI, a PDMS microchip was developed and evaluated. An on-line coupling to ESI-MS was made possible using a durable integrated graphite electrospray tip with good electrochemical stability, as shown in paper IV. In addition, a novel fabrication method, described in paper VI, enabled the introduction of microelectrode arrays into the flow channel. These electrodes, which were shaped as coils covering the walls of the cylindrical channels, enabled electrochemical sample modifications prior to detection. Furthermore, the coupling of the EC controlled system to the ESIMS was simplified and improved using a wireless battery driven potentiostat. 8 2. Sample preparation techniques 2.1 Pressurized-fluid extraction In the last few years, new solvent extraction techniques have been developed in order to reduce the volume of solvents required for the extraction, improve the precision with respect to analyte recoveries, and to reduce extraction times and sample preparation costs. One of these techniques is pressurized-fluid extraction (PFE), also known as accelerated solvent extraction (ASE¥, Dionex). This technique enables rapid static extractions of solid samples using less solvents than conventional Soxhlet, Soxtec or liquidliquid extraction techniques, based on the use of elevated temperatures (40200qC) and pressures (100-140 atm) to maintain the solvent in the liquid state.1, 2 Today, the PFE technique have been used to successfully extract a large variety of different compounds from various solid and semisolid samples.1, 3-5 The performance of PFE mainly depends on the disruption of surface equilibria, and solubility and mass transfer effects, caused by the elevated temperatures and pressures.1 There are however also other advantages and parameters to consider. With the easily automated PFE instrumentation, it is possible to perform 24 sequential extractions with different solvents or solvent mixtures, as well as gradients, employing different extraction times. More selective extractions can also be achieved by adding various adsorbents, filters or gels to the sample cells.6 In addition, compared to other available conventional extraction techniques, PFE enables extractions in a controlled atmosphere, which for example could be used to prevent oxidization of certain analytes. The dissolution rate, and the capacity of solvents to dissolve analytes, generally increases when the temperature is increased. Furthermore, the viscosity and the surface tension of solvents and the matrix decrease at higher temperatures. This allows better penetration of the matrix particles and facilitates the contact between the analytes and the solvent, which enhances the extraction process, as described by Richter and co-workers.1 Thermal energy also decrease the energy required for desorption processes by disrupting hydrogen bonding, dipole attractions, and cohesive (solute-solute) and adhesive (solute-matrix) interactions.1 Another advantage is that the solubility of water in organic solvents generally increases with increasing tempera- 9 ture. This makes it possible for organic non-polar solvents to penetrate otherwise water-sealed pores containing analytes.1 Due to the possibility of using higher extraction temperatures and pressures, the range of solvents applicable in PFE is much wider than in for example Soxhlet extractions. During the extraction, the pressure has to be high enough to keep the solvent in the liquid state at temperatures above the boiling point. It is, however, not clear whether a change in the pressure has any significant effect on the recoveries, in contrast to the pronounced effect of altering the temperature.1, 6, 7 A schematic description of a PFE instrument is showed in Figure 1. Extraction cells of different volumes are available, and they usually contain stainless steel frits and a cellulose filter, placed at the bottom of the cell. The sample is enclosed in the extraction cell, which is automatically filled with an extraction solvent by opening a pump valve, and pressurized by the pump. The cell is then heated with electronically controlled heaters and statically extracted during a selected time. To maintain the desired pressure during the heating step, a static valve opens periodically. After the extraction, compressed gas is used to purge the sample extract from the cell into a collection vial. It is possible to perform one or several flushes with a selected volume of solvent after the first extraction. In this way, a sample can be extracted a number of times with fresh solvent. Extraction cell Purge valve Pressure relief valve Oven Pump Static valve Solvent Nitrogen Vent Waste vial Collection vial Figure 1. A schematic illustration of a PFE system. The disadvantages with PFE instruments are the initial cost of the instrument, and the fact that the extracts often need additional sample pretreatment prior to analysis. However, the reduced solvent consumption and faster extraction times reduce the costs in the long run, and as shown in paper I, PFE 10 requires less sample clean-up than the Soxtec technique. Another disadvantage is the efficient extraction itself, as some solvents can cause partial solubilization of certain matrixes at high temperatures and pressures. These substances can then plug the system upon exiting from the extraction cell, a phenomenon experienced at our department with plastic matrixes. 2.2 Solid-phase microextraction Solid-phase microextraction (SPME) is a solvent free alternative sample preparation step used to isolate, purify and concentrate analytes from a sample matrix in one single step. The method, which was developed by Pawliszyn and co-workers8 in the late 1980-ties, is a rapid, inexpensive, and easily automated technique mainly used for the extraction of organic compounds from gaseous and liquid samples. It involves an extraction and desorption of specific analytes directly from aqueous samples, or from the headspace of such samples in closed vials, utilizing a small segment of fused silica fiber. The fiber is coated with an appropriate material, mounted on a syringe-like device as shown in Figure 2. Figure 2. A schematic description of a SPME device. 11 The mass transport of the analytes from the sample to the coating is the rate-determining step in the extraction, and in aqueous samples agitation methods such as sonication or magnetic stirring are commonly used to shorten the extraction times.9 Using the headspace approach can substantially reduce the extraction time since the diffusion of analytes is many times faster in the vapor phase than in the aqueous phase.10 Another advantage with the headspace technique is that samples with virtually any matrix, such as soils, can be analyzed since the fiber is not in direct contact with the sample.10 After equilibration, or a well-defined adsorption time, the fiber containing the absorbed, or adsorbed analytes, is removed and usually thermally desorbed in the hot injector of a gas chromatographic system.9 Thus far, the technique has enabled the extraction of a vide variety of various organic species from different sample matrixes.11-17 Although the coatings used in SPME have high affinities for organic compounds, enabling preconcentration and good sensitivities, the analyte partition coefficients between the coating and the sample matrix are generally not large enough to completely extract all available analytes.9 This problem is overcome by calibration, since it is an equilibrium sampling method that can be described by the Langmuir adsorption isotherm.18 The simplest isotherm is based on three assumptions: (1) only a monolayer of adsorbate can be formed at the surface; (2) all sites are equivalent and the surface is uniform; (3) there are no interactions between adsorbed molecules at neighboring sites.19 The dynamic equilibrium between a molecule (M), an empty site (S), and the adsorbed complex (MS) is M S MS (1) with rate constants ka for adsorption and kd for desorption.18 At equilibrium the net rate of adsorption is zero, and thus the rate of change of surface coverage due to adsorption and desorption are equal and can be described by the following simplified equation: k a >M @N (1 T ) k d NT ( 2) where N is the total number of sites i.e. the maximum surface concentration of the analyte, T is the extent of surface coverage, and [M] is the concentration of M in the sample at the fiber surface.19 Solving T ([MS]/N) yields the dependence of the amount of analyte adsorbed by the fiber coating on the analyte concentration in the sample: 12 >MS @ NK A >M @ 1 K A >M @ (3) where KA is the adsorption equilibrium constant and [MS] denotes the surface concentration of the adsorbed complex.18 Although it is difficult to apply equation (3) in practice, it can be further developed to give the relationship between the initial analyte concentration in the sample and the extracted amount, as described by Górecki et al.18 If an absorbing coating is used, the amount of analyte absorbed by the fiber coating at equilibrium is related to the analyte concentration in the sample according to equation (4) m KC0MVf Vs KVf Vs ( 4) where m is the mass of analyte absorbed by the coating, K is the partition coefficient of the analyte between the coating and the sample solution, Vf and Vs are the coating and sample volumes respectively, and C0M is the initial analyte concentration.9 When extractions are performed in large sample volumes (Vs >> KVf), the extracted amount does not depend on the sample volume:9 m KC 0MVf (5) Since SPME mainly is an equilibrium extraction technique, depending on the partition coefficients, the sensitivity is determined by several different factors affected by both the coating and the sample matrix.20 By changing the coating material, increasing the volume of the coating, or manipulating the matrix, the extraction efficiencies can be increased.18 It is however difficult to extract polar and charged compounds from aqueous samples using the uncharged conventional coatings that are commercially available, as these coatings have to have a stronger affinity for the analytes than water. This problem is usually solved through derivatisation of either the target analytes, to increase their volatility, or of the coating, or by the addition of complexing agents.21-23 Although derivatisation can improve the sensitivity, it is not a process without drawbacks. It is a time consuming step that sometimes involves toxic reagents and solvents, and it is not uncommon that the derivatisation reagent reacts with matrix components to produce unstable products. These side reactions complicate the extraction process, and can also effect the sensitivity.22, 23 13 2.2.1 Electrochemically controlled solid-phase microextraction In paper II, a novel approach of performing SPME under electrochemical control is presented. In this study, polypyrrole was used as a conductive coating and instead of using a normal SPME device as described in Figure 2, a compact three-electrode device, shown in Figure 3, was employed. This set-up has several advantages compared to the more traditional electrode setups employed in other recent studies in which electrochemically modified electrodes were used to perform SPME.22, 24 First of all, the electrode device is compact which enables electrochemically controlled extractions and desorptions in small sample volumes. In previous studies, employing traditional three-electrode set-ups and electrochemically modified metal fibers as working electrodes, successful desorptions have not been performed in small (PL) volumes.22, 25, 26 This is a major drawback since the desorption volume affects the sensitivity. However, in a recent study Tamer et al.27 performed electrochemically aided SPME of neutral analytes using conducting polymer coated platinum wires. The latter authors performed the desorptions in a 250 Pl three-electrode cell. Figure 3. Cross-sectional representation of the manufactured SPME electrode device in the (a) extraction and (b) transfer mode. 1, stainless steel counter electrode; 2, polyethylene insulation; 3, silver quasi reference electrode; 4, PTFE insulation; and 5, glassy carbon working electrode. Another advantage with the compact three-electrode device is that the individual parts of the electrode device can be moved relative to each other. 14 By pulling the working electrode inside the counter electrode, the extracted species can be transferred between solutions under controlled potential conditions, due to a small amount of capillary held solvent remaining between the electrodes. This eliminates open circuit problems such as oxidation, and spontaneous charging and discharging processes of the polymer, and makes it possible to fully control the entire extraction and desorption process. The most promising application of combining electrochemistry with SPME is perhaps the fact that both the extraction and desorption can be performed by simply changing the applied potential. This totally eliminates the use of different desorption solvents and the commonly used thermally desorption techniques. Combining the use of electrodes with a conducting polymer coating such as polypyrrole further increases the possibilities and enables the extraction of charged species. In paper II, two types of polypyrrole coatings were used in order to extract both anions and cations according to the principle described in section 3.1. The results demonstrate the capability and potential of this new SPME approach, but also points out some of the difficulties associated with preconcentrations using this extraction and desorption technique. The simplest way to increase the sensitivity is to reduce the desorption volume and to perform the entire sample preparation step online in a miniaturized flow system, as described in paper III. 2.3 Solid-phase extraction in microflow systems Solid-phase extraction is traditionally a time consuming off-line procedure that may require large volumes of samples and solvent.28 Integrating this sample preparation step within a miniaturized flow system, enabling extraction, desorption and detection, can eliminate sampling handling losses, contamination problems and greatly simplify the overall procedure. During recent years, on-chip SPE has received increased attention since it is often required to improve the selectivity, sensitivity and for the removal of interferences in association with very small sample volumes.29 There are, however, several problems associated with the use of SPE in miniaturized systems, mainly due to the small dimensions of the microfabricated channels used in these devices. Today new techniques to perform SPE in miniaturized systems have been developed. A common technique to perform an increase in concentration, or to purify an analyte on-chip, is by use of sample stacking by zone electrophoresis or iso-electric focusing.30, 31 The drawback of these procedures is that they require the presence of an electrodriven system such as a capillary electrophoresis microchip. Another approach is to extract and preconcentrate the sample on a microfabricated material with a high affinity for the analyte. Yu and co-workers32 successfully performed SPE using monolithic porous polymers prepared by photoinitiated polymerization inside microchip chan15 nels, and Kutter and co-workers33 used C-18 as a stationary phase to modify microchip channels. The preparation of these phases is more tedious compared to for example electropolymerization, and in order to achieve desorption and release the extracted species, the solvent has to be replaced by a stronger eluent. Different types of coated microspheres have also been used as on-chip SPE materials.34 Oleschuk et al.34 presented an exchangeable microchip cavity structure in which octadecylsilane coated silica beads were trapped and used for preconcentration. 2.3.1 Electrochemically controlled solid-phase extraction in microflow systems As described in paper II, III and V, polypyrrole coated electrodes can be used to extract and desorb a range of analytes. By performing these extractions in miniaturized flow systems, preconcentrations are possible since the desorption step automatically occurs within a very small volume. This approach was investigated in paper III employing an array of microelectrodes for both the extraction/desorption and the detection of a model analyte in a miniaturized flow system. The principle of this type of preconcentration is the same as for regular stripping analysis in a flow system. First analytes are accumulated on the polymer during a certain period of time, and by then changing the applied potential the analytes are desorbed. There is however an important difference between SPE employing a conducting polymer and related stripping analysis techniques; the active conducting surface of the polymer coated electrode is significantly larger. When regular electrodes are used for preconcentrations of for example organic substances, using adsorptive stripping voltammetry (AdSV), the dynamic range is usually limited as only the bare electrode surface is available for adsorption.35 One way of overcoming this problem is to coat the electrode surface with a conducting polymer such as polypyrrole. This increases the number of charged sites available for extraction and thus the dynamic range. The SPE technique described in paper III has several advantages. Electrodes are today readily incorporated and used in conjunction with micro analytical devices,36 as described in paper VI, and their performance is also enhanced upon miniaturization.37, 38 Another advantage is that a conducting polymer such as polypyrrole can be easily electropolymerized in small systems containing electrodes, from a monomer solution. Finally, using a conducting polymer should make it possible to prepare fine structures inside small channels depending on the thickness of the polymer and its morphology. The surface structure of the polymer depends on the electropolymerization process, as is described in section 3.1. The results presented in paper III show that EC controlled SPE can be used as an effective preconcentration step in miniaturized analytical flow 16 systems. Significant preconcentration was possible using extraction times of only a few minutes and a good linearity between the extraction time and the detection response was present both for mM and PM sample concentrations. The preconcentration factor could be increased by a factor of 210, compared to the results presented in paper II, due to the use of a miniaturized flow system. In paper III, the detection was performed using one of the individually addressable microelectrodes available on the microarray electrode. Although EC detection is very suitable for microanalytical devices, as further described in section 4.2, the detection is generally limited to electroactive species. The on-line coupling of EC controlled SPE, employing conducting polymers as extraction phases, to mass spectrometric detection is therefore of great interest. The latter combination was studied in paper V using a thinlayer cell, in which the working electrode was coated with a polypyrrole film. Although the on-line EC/SPE-MS combination significantly increases the analytical possibilities, there are difficulties associated with the combination of the two techniques. In section 5, the on-line coupling of EC/SPE with both electrospray ionization and inductively coupled plasma MS detection is described and evaluated. 17 3. Polypyrrole 3.1 Polymerization and properties of polypyrrole Polypyrrole and its derivatives are today, mainly due to their high electrical conductivity, facile synthesis, and relatively good stability of the oxidized state of the polymer, one of the most studied groups of conducting polymers. The polymer is easily prepared by either an oxidative chemical polymerization, or using electrochemical oxidation in aqueous or organic solutions by applying a positive potential to a monomer solution containing an appropriate supporting electrolyte.39 The electrochemical oxidation of pyrrole, which involves the formation of radical cations and subsequent polymerization, is illustrated in Figure 4.40 A + . + Oxidation (-e) n N H A - A - Polymerization H H N N N N N H H H n + A - n Figure 4. Suggested polymerization reaction of pyrrole to yield polypyrrole. In its oxidized state, it has been found that polypyrrole contains one positive charge per three or four pyrrole rings, while the polymer is neutral in its reduced state.41 During the polymerization, anions in the electrolyte solution are incorporated in the polymer film to maintain the charge balance. The presence of these so called dopants greatly effect the properties of the polymer, and by using different counter ions during the polymerization it is possible to create polymers for many different applications.42-59 If a small anion with a high mobility inside the polymer film is used as a counter ion during the polymerization, it will be expelled when the polymer is reduced, and thus the film becomes an anion exchanger. By incorporating a large immobile anion, the film can be used as a cation exchanger in its reduced state, since cations will be incorporated in the film to maintain electroneutrality, as shown in Figure 5. A polypyrrole (PPy) film doped with the anion (A) is often denoted PPy(A). 18 + +A N ox. n H A N red. n H + AA C + N ox. n H AA + C + N red. n H Figure 5. Ion exchange properties of polypyrrole films doped with a small mobile anion (A-) and a large immobile anion (AA-), respectively. The doping and undoping process of polypyrrole is presently not completely understood, and reports indicate that both anions and cations, and accompanying water, can enter the polymer upon the oxidation and reduction.60-63 A simple way of studying the redox properties of many conducting polymers involves the use of cyclic voltammetry (CV), as described in paper V. When using this reversal technique, the applied potential is varied linearly with time, while the current is recorded as a function of the potential. An example of how CV can be employed to study the doping and undoping of a polypyrrole film in two different pH 4 solutions is given in Figure 6. 1,2 i/mA 0,8 (b) 0,4 0 (a) -0,4 -0,8 -1 -0,5 0 0,5 E/V Figure 6. Cyclic voltammograms of polypyrrole in two different pH 4 ~50 mM buffer solutions containing; (a) potassium phthalate/biphthalate and (b) sodium acetic/acetic acid, in addition to 0.5 M NaNO3, scan rate 100 mV/s (n = 3). The difference between the (a) and (b) voltammograms can be ascribed to the different buffer solutions (~50 mM), despite the fact that both voltammograms were recorded in the presence of 0.5 M NaNO3. In (a) the buffer solution contained potassium phthalate/biphthalate, which was found to significantly suppress the doping-dedoping of nitrate, probably due to an ad19 sorption of the large organic phthalate ion to the polymer surface. On the other hand, the use of a sodium acetic/acetic acid buffer (b) resulted in a rather typical polypyrrole voltammogram, with broad oxidation and reduction peaks due to the incorporation and expulsion of the nitrate anion. The use of different counter ions during polymerization also significantly alters the conductivity, flexibility, elasticity, permeability, morphology and other physical and mechanical properties of the film.39, 58, 64-67 This in combination with the natural ability of the polymers to interact with many different compounds, make it possible to introduce a certain degree of selectivity with respect to various types of analytes in the film.68-70 An example of the effect of dopants on the polypyrrole morphology is shown in Figure 7, in which scanning electron micrographs of polypyrrole films doped with perchlorate and bromide ions are compared at different degrees of magnification. (a) (b) 2k 34k 148k Figure 7. Scanning electron micrographs of (a) PPy(ClO4) and (b) PPy(Br) coatings at three different degrees of magnification. 20 3.2 The role of polypyrrole in analytical chemistry Since polypyrrole is electrically conducting, the redox switching of the polymer can be electrochemically controlled or obtained employing reducing and oxidizing solutions. This makes it highly interesting for the development of controlled release devices and separation processes in novel analytical systems. In electrochemically modulated liquid chromatography, polypyrrole coated stationary phases under potentiostatic control have been used to perform separations of different types of analytes.71 These polypyrrole columns have the ability to alter their retention properties and thus their molecular interaction capabilities during operation by merely changing the oxidationstate of the polymer. This can be performed using either direct electrochemical control or a concentration gradient of a redox reagent.72 Porter and coworkers71 have successfully constructed electrochemically modulated liquid chromatography (EMLC) columns in which polypyrrole coated graphitic particles have been used as conductive supports i.e. the working electrode/stationary phase. Polypyrrole has also been shown to be an excellent coating for in-tube SPME, an on-line extraction technique in which analytes are extracted and concentrated on an extraction phase coated on the inner surface of an open tubular capillary positioned between a sample loop and an injection device.26, 70 Pawliszyn and co-workers70 have shown that polypyrrole coated capillaries show higher extraction efficiency for polar and aromatic compounds compared with the commercial extraction phases currently used for in-tube SPME. More recently, electrodes coated with polypyrrole have been used in SPME; a technique that traditionally utilizes thin film coated fused silica fibers as extraction phases.25, 54 The main advantage of using a conducting polymer when performing these extractions is that charged species can be extracted without having to perform derivatisations or employing complexing agents. In addition, desorption can be achieved by simply changing the applied potential as described in paper II. Polypyrrole and related polymers can also be used as freestanding functional membranes or as coatings on porous supports.65, 73 The different applications and functions of these membranes, which can be used for both liquid and gas separations, have been reviewed by Lewis56 and Wang et al.39 In principle, the transport of charged species as well as the transport rate and the selectivity of these membranes can be controlled by applying different potentials, and by using different dopants during the polymerization. As described above, the properties of a polypyrrole film depends on the mobility of the incorporated dopants. Ehrenbeck and Jütter74 utilized this possibility and prepared a polypyrrole membrane by copolymerization of modified pyrrole monomers of n-sulfopropyl-pyrrole, containing both mobile and immobile anions. This resulted in a membrane that could be electrochemically redox switched between both anion and cation selectivity. 21 By monitoring the current accompanying the incorporation and expulsion of electroinactive species in a polypyrrole film, it is also possible to perform amperometric detection using the polymer as the sensor.52, 75 In the simplest case, the polymer is doped with a mobile anion and functions as an ion exchange sensor. Since the doping, undoping and redoping process of the polymer is only to a certain degree selective with respect to the size of the incorporated anion used during the polymerization, the polymer films are usually used as a sensor subsequent to a separation in flow systems.50, 52 There are however many different parameters that have to be considered if these sensors are to function properly, since small changes in the current are being monitored. Variations in the conductivity, e.g. due to an eluent, can for example result in a change of the effective applied potential and thus the electrochemical switching potential affecting the doping level of the polymer.51 It is also possible to incorporate different biochemical recognition species such as enzymes76, 77, antibodies78, 79 or metal complexing groups45 capable of extremely specific molecular and ionic recognition. Another advantage of using a conducting polymer such as polypyrrole as an electrochemically modified electrode is that it is easily electrodeposited on electrodes in micro fluidic channels from a monomer solution. This, and the wide range of applications, makes polypyrrole an interesting tool for micro total analysis systems (P-TAS).80 22 4. Miniaturization 4.1 Miniaturizing analytical devices The interest in miniaturized analytical techniques is growing rapidly and such systems have in recent years become very attractive because of the number of advantages they posses over traditional analytical techniques. Some advantages such as reduced sample and reagent consumption, which often are of primary importance in environmental or biomedical sciences, and faster separations and reduced analysis times, are evident.81 There are however additional benefits with chip based devises such as reducing the cost per reaction and an improvement in the reaction kinetics on for example biological assays.82 An increased sample throughput is also possible as miniaturized systems facilitate parallel and automated operations. Disposable lab-on-a-chip devices should also significantly reduce cross contamination and carryover effects in analytical chemistry. Today, the miniaturization of electronic and optical devices, sensors and actuators for mechanical, chemical and biological applications, has led to the development of P-TAS, as described in a recent review by Manz and co-workers.83, 84 These systems, although generally expensive to produce initially, can be mass-produced at low cost for many different applications such as capillary electrophoresis separations,85 ion chromatography,86 enzymatic analysis,87 hydrodynamic chromatography,88 electrochromatography,89 liquid chromatography90 and capillary electrochromatography91. In P-TAS, different analytical standard operations such as sample preparation, injection, manipulation, separation and detection, as well as applications such as DNA separation,92 DNA sequencing93 and clinical diagnostics,94 can be performed using a single device.84 It is however worth mentioning that most analytical chip devices are produced for a specific application. Some of the steps mentioned above are more difficult to perform mainly due to the large surface-to-volume ratios originating from the open channel architecture employed in the microfluidic systems. Since conducting polymers have a high surface-to-volume ratio, are inexpensive and simple to produce, they are an interesting alternative for these micro devices. Conducting polymers can also be modified in a variety of ways, and are easily prepared and incorporated in microstructures.53 The small dimensions of the channel structures used in P-TAS devices, often varying between 50 nm and 100 Pm in depth and height, and the small 23 sample and reagent volumes, down to pL95, pose new challenges regarding both detection and sample preparation. There are several ways of performing detection on-chip, and some of the most common techniques are chemiluminescence,96 electrochemiluminiscence,97 electrochemical detection,98 fluorescence,99 and other optical measurements such as UV absorption100. Most of these methods are only suitable for a narrow range of analytes, or relatively high concentrations, and generally require complicated and expensive equipment. Another factor that limits the detection is the small amount of sample present due to the very small sample volumes. Electrochemical detection by the use of microelectrodes is, however, comparably simple and also exhibit improved performance upon miniaturization, but is generally limited to electroactive species. The combination of mass spectrometry with analytical chip devices is therefore of interest, as it may provide highthroughput sample identification, quantification and low detection limits.101 4.2 Use of electrodes in microflow channels Reducing the size of a working electrode from millimeter to micrometer dimensions has several important advantages that makes so-called microelectrodes very suitable for miniaturized analytical devices.37, 51 As the electrode area is decreased the measured current (i), typically pA-nA for microelectrodes, decreases. This reduces the ohmic potential drop (iR), where R denotes the cell resistance. The ohmic potential drop acts to weaken the working potential and can cause significant errors in amperometric detection if allowed to become too large.38 Due to the small currents associated with microelectrodes, it is also possible to use a combined reference and counter electrode in a two-electrode system.102 This further simplifies the experimental set-up in a miniaturized analytical system. An enhanced mass transport is likewise obtained since the spherical diffusion rapidly becomes dominant over planar diffusion when using for example disk microelectrodes.103 The faradic-to-charging current ratio and the response time of the working electrode are also improved, as the charging current and double layer capacitance decreases with decreasing electrode area.38 A consequence of this is the possibility to perform very rapid scanning of the applied potential. All these factors contribute to improve the quality of experimental data; steadystate signals are established rapidly and the signal-to-noise ratio can be improved.37 In addition, due to the advantages mentioned above, microelectrodes also enable measurements in low conductivity media, i.e. solutions with high resistances such as organic solvents. This makes microelectrodes versatile tools for amperometric detection in a wide range of sample matrixes. Microelectrodes are thus advantageous in many areas of electroanalytical chemistry and, due to their size, a perfect choice for miniature cell designs. 24 If an array of individually addressable electrodes is used for detection, both the sensitivity and the selectivity can be enhanced. The sensitivity is increased by employing every second band as a collector or generator electrode, respectively,104 as shown in Figure 8. Ox Red Ox Red Ox Red Ox Red Ox Figure 8. The principle of redox cycling using array electrodes in a flow system. The individual bands may also be used to detect different analytes by applying different potentials to different bands, thus increasing the selectivity.37 Since the technique is improved by the degree of redox cycling, i.e. the average number of times a molecule is reduced and reoxidized, it is well adapted for the low flow rates used in common microsystem.105 4.3 Microfabrication Many of the fabrication techniques used to create microstructures, such as lithography and molding, demands access to clean room facilities, involves expensive techniques, and are time consuming.106 Another difficulty with applying the fabrication processes and materials often originally developed for the microelectronics industry to analytical devises, is that the surfaces of the employed materials become more important upon miniaturization. The advantage of microfabrication is that as soon as a fabrication procedure is complete, it allows rapid replication and thus relatively cheap massfabrication. Since the initial production steps of new microanalytical fluidic devices often require evaluations of many different prototypes, it is important to develop simple and fast fabrication methods. To meet these demands, a variety of plastic materials that allows for low cost fabrication in the absence of clean room facilities have been used to produce prototypes.107 One such polymer is poly(dimethylsiloxane) (PDMS), a biocompatible commercially available physically and chemically stable material used in paper IV and VI. Other important properties of PDMS are low water absorption, high optical transparency, high stretch ability and low curing temperature.108 The drawbacks with this material include swelling, hydrophobicity, diffusivity and a relatively poor mechanical strength.108, 109 However, the synthetic polymer has a backbone of repeating units of silicon and oxygen that can be modified 25 by the introduction of various types of functional groups. This is a simple way of changing the mechanical and viscous properties of the polymer, which increases the versatility of the material.109 The most common way to produce microchannels in plastic materials like PDMS is to employ a procedure requiring several steps such as casting onto a master wafer, molding and bonding.108 The molding procedure creates three of the channel walls and a bonding step is then used to seal the channel to a flat surface. The sealing can be done reversible by van der Waals contact or irreversible by the use of an air-plasma, which produces a channel that can withstand significantly higher pressures.110 Compared to other materials, such as glass or thermoplastics, the PDMS sealing process is simpler, and as PDMS is an elastomer it can also seal to non-planar surfaces.110 In paper IV and VI, a new approach for the fabrication of microchannels in PDMS is presented. A schematic description of the PMMA mould used to create the chip device is shown in Figure 9. Figure 9. Schematic description of the PMMA mould used to produce the PDMS device. a-e represents the different modules defining the final structure of the microchip. The inset shows the coil array with isolating wires (in black) separating the electrodes from each other. A) stainless steel wire, B) fused silica capillaries, C) PEEK-tubing and D) isolating wires. By employing this fabrication method both a flow channel111 and a threedimensional emitter could be fabricated in a one step procedure. Furthermore, the stainless steel metal wire used to create the channel could be used to introduce electrodes into the channel wall, as described in paper VI. This 26 novel approach enabled the introduction of arrays of gold coil electrodes by simply twining a gold wire around the steel wire. The distance between the individual coil electrodes significantly affected the EC performance, as shown in Figure 10. In order to reduce the interelectrode distance, and consequently decrease the iR drop, isolating wires was twined between all coils. This prevented shortcuts, and supported and stabilized each coil when the channel wire was removed after the curing. A small interelectrode distance of 100 Pm inside the channel was necessary to obtain a cyclic voltammogram resembling that of a conventional three-electrode set-up. 0,4 (a) (b) 0,4 0,2 0,2 i/PA i/PA 0 0 -0,2 -0,2 -0,4 -0,6 -0,4 -2 -1,6 -1,2 -0,8 -0,4 0 0,4 0,8 -1 1,2 -0,5 0 E/V 2 0,5 1 E/V 2 (c) (d) 1 1 i/PA i/PA 0 0 -1 -2 -1 -3 -2 -4 -1 -0,5 0 0,5 E/V 1 1,5 -1 -0,5 0 0,5 1 1,5 E/V Figure 10. Voltammograms obtained with the micro gold coil electrodes (a) o (c) vs. a gold coil pseudo reference electrodes in 25 mM H2SO4. The distance between working and reference electrode was 4 mm (a), 1 mm (b), and 100 Pm (c). (d) shows a voltammogram obtained with a gold wire vs. a gold wire pseudo reference electrode using a conventional three-electrode set-up in 25 mM H2SO4. A way to create the three-dimensional emitters needed to combine microsystems with MS is by fitting a spray capillary to the outlet channel end.112 This method is robust, but often increases the dead volume prior to the emitter tip, which is avoided with the procedure described in paper IV. The introduction of electrodes into a microflow channel is often performed by sealing the channel replica to a flat surface containing microband electrodes. Today a vide variety of materials and fabrication techniques have been used 27 to integrate electrodes in lab-on-a-chip devices.113 The advantage with the technique described in paper VI is that it is inexpensive, relatively simple and demands no advanced equipment. This means that the procedure is well suited for the fabrication of chip prototypes. 28 5. On-line coupling of electrochemical systems to mass spectrometry 5.1 Electrospray ionization The electrospray ionization (ESI) technique was used for the first time in the late 1960s,114 and is based upon the transfer of ions from a liquid phase into the gas phase. ESI usually operates at ambient temperature and atmospheric pressure, and is a soft ionization technique by which complex and fragile molecules can be ionized without extensive fragmentation. It is most suitable for medium to polar compounds, and both small and large molecules can be analyzed. Multiple charging of large analytes reduces their mass-to-charge (m/z) ratio, which simplifies the detection of macromolecules. The electrospray is formed by applying a high electric potential of several kV, between a hollow emitter and a counter electrode plate. The principle of positive electrospray, with a positive potential applied to the emitter, is shown in Figure 11. Figure 11. Schematic description of the electrospray ionization process in the positive mode. (Figure provided by Andreas Dahlin) 29 As a solvent passes through the emitter, the high electric field forces the liquid to form a so-called Taylor cone,115 due to the electrostatic attraction between the counter electrode and ions of opposite charge. If the potential difference is sufficiently high the apex of the cone disperses into charged droplets which then travel towards the counter electrode. During this process the solvent evaporates from the droplets and gaseous ions are produced.116 5.2 Sheathless electrospray There are several types of interfaces used in ESI-MS, and the most common approaches when combining ESI with low flow rate applications using capillaries are the sheath-flow interface,117 the liquid junction interface118 and the sheathless interface119. The sheathless interface, shown in Figure 12, is well suited for polymeric microfluidic devices, and a common way of integrating the ES tip is to attach spray capillaries at the exit of the microchannel.120-122 It is however also possible to fabricate the emitter at the outlet of the microchannel from the bulk material of the chip.123 This significantly reduces the dead volume and increases the sensitivity, as there is no additional dilution of the eluting sample. The conductive surface of the emitter can also be used as one of the electrodes in CE separations. This enables electrophoretic separation to be performed all the way to the electrospray, as described in paper IV. When the emitter is fabricated from the non-conductive polymeric bulk material of a chip, or when a fused silica spray capillary is used, a durable conductive coating has to be applied. The stability of this conductive coating, and the fact that it is impossible to control the performance of the spray using a sheath or make up liquid, are the main limitations of sheathless ESI from miniaturized devices. Figure 12. Schematic description of the sheathless ESI interface. (Figure provided by Andreas Dahlin) 30 During ESI measurements there is a constant charge transfer between the emitter and the counter electrode, and when the analyte solution reaches the sheathless emitter only the tip of the thin conductive layer provides the electrical contact. In principle, the interface functions as a two-electrode controlled current EC cell where the steady state current is carried by the charged droplets formed at the working electrode i.e. the ES emitter.124 In positive ESI, an oxidation takes place at the emitter and a reduction consequently occurs at the counter electrode plate to maintain the charge balance. This means that the electrochemical stability of the emitter becomes very important as it determines the lifetime of an integrated sheathless interface. There are several methods available for the application of a conductive layer on spray capillaries and integrated emitters. The most common coatings are metal layers, with a relative short lifetime of less than 100 hours, applied by techniques such as sputtering, vapor deposition and electroplating.125 However, the so-called Fairy Dust techniques, by which gold particles are immobilized onto fused silica emitters using different types of glue can produce metal coatings with an excellent stability.126-128 Nilsson and coworkers, employing a graphite-polyimide mixture that produced durable socalled Black Dust coatings, further developed this technique.129 A similar coating procedure using a silicon-based resin as the glue, also containing graphite powder, was developed by Svedberg et al.130 The latter coating technique is compatible with the thermally unstable surface modifications commonly needed in PDMS devices, as silicon polymerizes at temperatures lower than 70qC. In paper IV, a thin layer of non-polymerized PDMS was used to glue graphite powder to a integrated three-dimensional PDMS emitter tip. The long-term stability of this coating was evaluated using off-line ES, during which the spray current was found to be stable for over 180 h, and chronoamperometry. Chronoamperometry allows for faster stability evaluations, as described by Nilsson et al.131 and Wetterhall et al.,132 and is hence a convenient way to study how the current density changes with time for different coatings. Although the current density for the graphite coating was found to decrease after 40 min, probably due to the formation of a passivating oxide layer, the emitter could be regenerated by reducing the coating as is shown in Figure 13. The extent of the regeneration most likely depends on the reduction time as the passivation layer was allowed to form during 40 min. 31 300 200 i ( A) 100 0 2.5 V 2.5 V -100 -200 -2.5 V -300 0 -2.5 V 10 20 30 40 Time (min) Figure 13. Chronoamperometric plot depicting the regeneration of the oxidized graphite coating using potential steps between 2.5 and –2.5 V vs. Ag/AgCl in 0.5 % nitric acid. 5.3 On-line coupling of electrochemistry and electrospray mass spectrometry Bruckenstein and Gadde, employing a porous electrode to study reactions involving volatile analytes, performed the first successful coupling of EC with MS.133 This and similar methods were later used and further developed by several groups,134-136 but the technique was initially limited to the detection of volatile species. The first EC-MS report regarding the detection of non-volatile analytes was published by Hambitzer and Heitbaum in the middle of the 1980s.137 Since then different types of two-138, 139 and threeelectrode140, 141 flow cell systems have been coupled on-line to MS using various types of ionization techniques, including ESI. As ESI is a soft ionization technique often producing multiple charge ions of large analytes, it is becoming one of the most important ionization techniques in mass spectrometry. The EC-MS combination further increases the analytical applications. When coupling an EC system to ESI there are several issues that have to be considered.142 The ES usually operates at kV potentials, which can severely affect the EC instrumentation and the electrochemical measurements. As reported by Van Berkel et al.142, different approaches can be used to successfully combine the two techniques. The entire EC system has to be either floating at the potential induced by the ES potential or be decoupled from the latter. In the first case, the induced potential depends on the applied ES volt32 age and the resistance between the EC cell and the electrospray high voltage electrode. A decoupling can therefore be obtained by increasing the distance between the EC cell and the ES contact, which however unfortunately increases the delay time and the band broadening. Another alternative is to introduce a ground point between the EC cell and the ESI high voltage electrode.142, 143 The main drawback with this method is that electrochemical reactions will occur at the ground point, which of course can cause severe interferences.144 In the floating mode, the EC system can be based either on a battery driven potentiostat or an isolation transformer, as in paper V.140, 142, 144 The floating mode allows for short connections between the EC cell and the ES emitter, which significantly reduces delay times and improves the detection of unstable species. The drawback with this mode of operation is that the absence of a ground point increases the risk of electrical shocks, and as a result the handling of the EC instrumentation becomes more difficult. A promising solution to this problem was examined in paper VI employing a wireless battery-powered potentiostat. In this study, the electrode equipped PDMS chip device shown in Figure 14 was employed to further reduce the transfer times. As is seen in this figure, the leads used to connect the gold wires to the potentiostat had to be shielded from the ESI high voltage using a protective PDMS cage to prevent electrical discharges. Figure 14. Schematic picture of the electrode equipped PDMS-ESI emitter device. A) denotes the protective PDMS cage, B) the leads connected to electrode array, C) the PDMS microchip with the integrated graphite coated electrospray emitter, D) the metal plate used to apply the high voltage to the graphite tip, E) ESI high voltage contact and F) graphite ESI emitter. Another factor that needs to be considered is the EC cell design. An appropriate EC cell design can minimize influences from the counter electrode reactions, as described by Bökman and et al. in a recent study.144 The choice of electrolyte can also be problematic, as most electrolytes commonly used in EC measurements are more or less incompatible with ESI. Non-volatile 33 electrolytes easily form gas-phase cluster ions that often suppress the analyte signal. These salts can also cause additional problems such as plugging of the emitter tip and contaminating the curtain plate. Some lithium salts have however been found to reduce suppression effects and is therefore an interesting electrolyte alternative.142, 145 5.4 Inductively coupled plasma mass spectrometry Inductively coupled plasma mass spectroscopy (ICP-MS), which was developed in the 1980s,146, 147 is a speciation technique employing a plasma source for the atomization, excitation and ionization of elemental species.148 As ESI, the ICP technique has high requirements regarding sample introduction, as the liquid has to be introduced in the form of fine droplets in order to fully desolvate and atomize. Sample delivery is commonly performed using a peristaltic pump, but due to the high sensitivity and selectivity of the technique it is also commonly used in conjunction with different chromatographic separation techniques.149 Aerosol generation of the sample is often accomplished utilizing a pneumatic nebulizer connected to a spray chamber. There are many types of nebulizers and spray chambers commercially available, adapted for different flow rates, all having different effects on the analyte transport efficiency and sensitivity.150 When the sample solution exits from the nebulizer it is mixed with a nebulizer gas (usually argon), and is converted into finely divided droplets. Approximately 1 to 3 % of the aerosol passes through the spray chamber into the torch body where it is mixed with an argon auxiliary gas.151 The nebulizer efficiency can however be significantly higher depending on parameters such as flow rate and solvent type. The droplets that are too large for the plasma are removed via a drain at the bottom of the spray chamber. A schematic description of the nebulizer, spray chamber and plasma is shown in Figure 15. A typical plasma torch consists of three concentric quartz tubes, where the inner tube contains the sample aerosol. The two surrounding tubes are used for auxiliary gas introduction and coolant gas. By applying a radio-frequency current to the induction tubes, wrapped around the quartz tubes, an oscillating magnetic field is created. This magnetic field and the argon gas flow sustain the plasma, which is initiated by the ionization of argon using a spark. The high temperature of the plasma (6000-10000 K) effectively removes any remaining solvent and causes sample atomization, ionization and excitation, which is used in ICP-atomic emission spectroscopy. In addition, due to the very high temperature molecular interferences are significantly reduced, but not completely eliminated.148 34 Radio-frequency induction coil Coolant gas Auxiliary gas Plasma Sample aerosol Spray chamber Aerosol Magnetic field Sample liquid Nebulizer gas Drain Figure 15. Schematic description of a nebulizer, spray chamber and a typical inductively coupled plasma. The main advantages with ICP-MS for speciation analysis are the low detection limits, high selectivity and a dynamic range that can cover up to eight orders of magnitude.149 Some of the difficulties with the ICP-MS technique are isobaric interferences, caused by equal mass isotopes of different elements, and polyatomic (or molecular) interferences due to recombination of ions, and plasma instabilities due to changes in the solvent composition and/or due to organic solvents.152 For example, in paper V, 81Br was overlapped by the polyatomic species 40Ar 40Ar 1H.153 The latter problem has to be considered when coupling ICP-MS to chromatographic techniques, and it can be reduced by for example employing different types of interfaces and voltages, and by optimizing the gas flow rates.150 Furthermore, introducing buffers and high concentrations of different salts can result in partial or total clogging of the sampler cone, and signal suppression due to space charge effects.151, 154 5.5 On-line coupling of electrochemistry and inductively coupled plasma mass spectrometry The on-line coupling of an EC cell to ICP-MS is uncomplicated compared to the EC/ESI-MS combination, and the coupling can readily be achieved using a small piece of tubing or a capillary. Commonly, the EC/ICP-MS combination is used for sample pretreatment such as preconcentrations and matrix elimination employing anodic155-157 or adsorptive158 stripping voltammetry. 35 In anodic stripping voltammetry (ASV) electroactive species are selectively accumulated by applying a suitable deposition potential. After the accumulation it is easy to change the solvent to a solution containing a minimal amount of interfering species, and the analyte is then stripped from the working electrode back into the flow system for detection. Both flow-through EC cells employing porous electrodes159, 160 and thin-layer EC cells157, 161 have successfully been coupled to ICP-MS for the determination of a wide range of compounds. The advantage of the flow-trough cells is the high deposition efficiency, while the drawback is the dilution of the accumulated sample upon stripping due to the large cell volume.156 Thin-layer cells have proven to be more advantageous with respect to signal enhancement, but the very small cell volume and the low flow rates increase the demands on the nebulizer and spray chamber to reduce dispersion effects.156, 157 In paper V, a thin-layer EC cell coupled on-line with ICP-MS was used to perform preconcentrations utilizing polypyrrole coated electrodes. The advantage with this approach is that the amount of charged sites available for extraction can be altered by increasing or decreasing the polymer thickness. In addition, it enables the extraction of species unsuitable for adsorptive and anodic stripping voltammetry. A drawback with the use of a thick polymer coating and long extraction times is however the prolonged desorption process, which increases the dilution and dispersion of the released analytes. This effect could be reduced by turning the flow off while performing the desorptions. Figure 16 shows the dependence of the analyte signal response on the extraction time, employing the stopped flow desorption technique. (e) 8,E+05 (d) Inte nsity 6,E+05 (c) 4,E+05 2,E+05 (b) (a) 0,E+00 0 5 10 15 T ime /min Figure 16. A comparison of bromide ion peaks obtained using the stopped flow desorption technique, employing the following extraction times: (a) 5 min, (b) 10 min, (c) 20 min, (d) 30 min and (e) 40 min. 36 6. Concluding remarks and future aspects Different sample preparation steps prior to detection are often time consuming and essential parts of analytical chemistry. Today many of the techniques used to prepare a sample for analysis consumes large quantities of solvents and materials, and they are often difficult to automate and to perform online. In paper I, the relatively new automated PFE technique was evaluated using samples with a very complex organic matrix. The results of these experiments show that PFE enable selective and effective extractions, using less solvent and a significantly reduced sample preparation time. Much research and development is also performed to enable fast and automated sample preparation systems suitable for miniaturized analytical devises. In such devices, separations and preconcentrations are often performed using chemically modified surfaces and different eluents. The uptake and release of charged and neutral species can be electrochemically controlled using conducting polymers as a stationary phase. This was studied in paper II, employing polypyrrole as a stationary phase in an all-in-one SPME electrode device, and in paper III, where microarray electrodes were used for both extraction and detection in a flow system. The results show that polypyrrole coated electrodes can be used for extractions of charged species, and that increased preconcentration factors can be obtained by miniaturization i.e. by reducing the desorption volume. A common problem for many different detection techniques is interferences that, for example, distort and/or overlap with the analyte signal, or otherwise negatively affect the general performance of the detection technique. In addition, as the sample volumes are reduced and the interest in detecting lower and lower analyte concentrations increases, on-line sample preparation and manipulation becomes more challenging. Furthermore, to fully benefit from the small dimensions in lab-on-a-chip devices it is vital to minimize the dilution between separation/preparation steps and detection. One way to reduce some of these problems is to introduce filters or to perform some kind of analyte extraction and preconcentration prior to detection. Electrochemical detection is a very versatile technique for the detection of electroactive species in micro flow channels, but on-line couplings to different MS techniques are often also desirable to increase the range of analytical applications. The use of polypyrrole as a general preconcentration device in on-line MS systems was therefore studied, as described in paper V. A difficulty with the integration of the latter two techniques was that the electro37 lytes commonly used to ensure optimal EC control of the electrodes are not always compatible with MS detection. In addition, charged species used to increase the conductivity of the sample solutions might compete with the analyte for the charged sites in the polymer, and thus reduce the extraction efficiency. The results did however show that polypyrrole can be used as an EC controlled preconcentration step prior to detection, but further studies are needed to completely evaluate the usefulness of the technique in combination with ESI-MS. In paper IV, a novel approach was employed to fabricate a hybrid capillary-PDMS microchip with a durable integrated three-dimensional ESI emitter. This analytical device enabled on-line coupling of capillary electrophoresis to ESI-MS detection. No measurable band broadening effects, compared to a fused silica capillary sheathless interface, was observed due to the hybrid PDMS device. The fabrication method was further developed in paper VI, in which gold coil electrodes were incorporated to the micro flow channel. These electrodes could be used to perform on-line EC manipulations of a model analyte, using a battery-driven wireless potentiostat that greatly simplified the EC-MS coupling. The results of these studies show the successful combination of EC and ESI-MS employing a miniaturized analytical device, which further developed and explored could become an important contribution to the lab-on-a-chip field. 38 7. Acknowledgements I want to express my gratitude to all friends and colleagues at the department for their support, and for helping my finishing this thesis. I especially want to thank: My supervisor Leif Nyholm, for encouraging me, and for always being there when I needed support. No one can critically review manuscripts like you, and without your electrochemical knowledge this work would have been a lot more difficult. I cannot imagine anyone having a better supervisor! Jonas Bergquist for your support at the end when I really needed it! Karin Markides for accepting me as a graduate student in analytical chemistry. Jean Pettersson for fruitful discussions and helping me with everything related to ICP-MS. Co-authors Marie-Louise Nilsson and Monica Waldebäck for their support in the beginning and for introducing me to PFE. My other collaborators: Niklas Forsgard, Andreas Dahlin and Camilla Zettersten, for your help in this work. It was fun working with you, and I wish you all the best of luck with your own research! Björn “capo di tutti capi” Arvidsson, for being a good friend and roommate. One day you might be the King of the Lab! Oliver Klett, my first room-mate, for your assistance and interesting discussion when I started working at the department. All past and present colleagues at the department. Special thanks to Magnus, Stefan, Ardeshir, Joakim, Sara B, Sara U, Emilia, Nina, and my teachers Marit, Rolf, Roland, Eva and Per for your support and fruitful discussions about chemistry and research. 39 Yngve Öst, Erik Forsman, Lasse Svensson, Bosse Fredriksson and Barbro Nelson, for helping me with technical and practical issues. Captain and crew of the greatest clan in NZ history. All my friends! My mother, father and sister for your never-ending support and encouragement. 40 8. Summary in Swedish Utveckling och undersökning av nya provupparbetningstekniker Elektrokemisk extraktion och utvärdering av miniatyriserade analytiska plattformar kopplade till masspektrometri Syftet med denna avhandling har varit att undersöka olika provupparbetningsmetoder lämpade för chip-baserade elektroanalytiska analyssystem eller motsvarande system baserade på masspektrometrisk detektion. En viktig del av projektet har bestått i att undersöka hur man med olika extraktionsmetoder kan uppnå en uppkoncentrering av analyter. Tonvikten har lagts på att använda modifierade elektrodytor i flödessystem för att elektrokemiskt kunna styra både extraktions- och desorptionsprocesserna. Detta arbete har även inkluderat utveckling och utvärdering av ett poly(dimetylsiloxan) (PDMS) mikrochip med en integrerad elektrosprayelektrod och en flödeskanal innehållande elektroder. I artikel I användes en relativt ny statisk extraktionsmetod för att extrahera klorerade paraffiner från ett fast prov med en komplex organisk matrix. Metoden kallas trycksatt vätskeextraktion (PFE), och det är en automatiserad teknik där upp till 24 prov kan extraheras i sekvens. Proven placeras i stålcylindrar vilka sedan fylls med önskat lösningsmedel och placeras i en ugn. Ett högt gastryck används för att behålla lösningsmedlet flytande vid temperaturer över dess kokpunkt. Detta förbättrar förutsättningarna för snabb och effektiv extraktion då ökad temperatur bland annat ökar substansers upplösningshastighet, samt minskar vätskors viskositet och ytspänning, vilket gynnar extraktionsprocessen. Detta har i sin tur lett till att extraktionstiden och/eller lösningsmedelskonsumptionen kan minskas i förhållande till andra konventionella tekniker. Resultaten från vår studie visar tydligt hur olika extraktionsparametrar som temperatur, tid och lösningsmedel påverkar både selektiviteten och utbytet. I jämförelse med Soxtec-tekniken kunde extraktionstiden, samt den efterföljande provupparbetningen och lösningsmedelskonsumptionen reduceras signifikant med hjälp av PFE. En annan statisk extraktionsteknik kallad fastfasmikroextraktion (SPME) studerades i artikel II. Denna teknik bygger på fördelningen av analyter mellan ett polymermaterial applicerat på en fiber, och själva provlösningen. Extraktionsprocessen går till på så sätt att en polymertäckt fiber med en hög 41 affinitet till analyten sänks ned i en provlösning under en bestämd till. Uppkoncentrering och desorption sker sedan genom att t.ex. flytta över fibern till en liten volym av ett rent lösningsmedel med än ännu högre affinitet för analyten. Tekniken skulle kunna vara ett attraktivt alternativ till de provupparbetningssteg som ofta används efter extraktionstekniker som PFE och Soxtec. Vanligtvis används SPME för att extrahera olika organiska substanser, då de kommersiella polymermaterialen ofta fungerar mindre bra för polära och laddade substanser. Genom att täcka fibern med en elektriskt ledande polymer, som t.ex. polypyrrol, kan dock tekniken användas för att extrahera både negativt och positivt laddade analyter. I artikel II konstruerades ett kompakt tre-elektrod-SPME-instrument som möjliggjorde elektrokemiska (EC) extraktioner under potentialkontroll. Treelektrodinstrumentet var uppbyggt av individuellt rörliga små rör vilket gjorde det möjligt att dra in arbets- och referenselektroden inuti motelektroden efter extraktionen. Den pålagda potentialen kunde därför bibehållas även när elektroderna transporterades mellan olika vätskor, p.g.a. den medföljande kapillärt bundna vätskevolymen. Då SPME-instrumentet var uppbyggt av elektroder kunde både extraktion och desorption styras genom att ändra potentialen på den polypyrroltäckta extraktionsfibern, d.v.s. arbetselektroden. Vid en positiv potential oxideras polypyrrol och vissa negativt laddade substanser i provlösningen kommer att vandra in i polymeren för att neutralisera de positiva laddningarna. Genom att sedan flytta över elektroden till en ny vätska och reducera polymeren kan de negativt laddade substanserna desorberas elektrokemiskt. Eftersom oxiderad polypyrrol är positivt laddad, och reducerad polypyrrole är oladdad, måste polymeren modifieras för att man skall kunna extrahera positivt laddade substanser. Detta görs genom att under den elektrokemiska polymerisationen dopa polymeren med en tillräckligt stor negativt laddad molekyl som byggs in i polymermaterialet. Polypyrrol kan appliceras på en elektrod genom att man oxiderar pyrrol monomerer till katjonradikaler, som kombineras, deprotoneras och bildar polymeren. Denna s.k. elektropolymerisering skapar positivt laddade polymerkedjor på elektrodytan. Under denna process blir polymeren dopad med de anjoner som finns i lösningen, d.v.s. ledelektrolytens anjoner. Är anjonen relativt liten och mobil i polymeren kommer den att bli utstött vid reduktionen av polymeren, och polymeren kan användas som en anjonbytare. Vissa stora anjoner kommer dock att bli steriskt hindrade från att vandra ut och in genom polymeren. Detta innebär att polymeren inte blir neutral vid reduktionen, utan får en negativ nettoladdning vilket kompenseras genom ett upptag av katjoner. Två olika polypyrrolfilmer användes i artikel II för att elektrokemiskt extrahera både anjoner och katjoner. Polypyrrol dopad med perklorat fungerade som en anjonbytare och paratoluensulfonat dopad polypyrrol kunde användas som en katjonbytare. Möjligheten att använda polypyrrol som ett uppkoncentreringssteg för analyter i miniatyriserade flödessystem studerades i artikel III. I detta arbete 42 placerades parallella rader av plana mikroelektroder, vilka fungerade som arbetselektroder, vid utloppet av en kapillär. Den första elektroden täcktes med polypyrrol och användes för att extrahera och desorbera analyter, medan den efterföljande elektroden användes för elektrokemisk detektion. Resultatet av studien visade att man kunde extrahera anjoner från vätskeflödet genom att lägga på en positiv potential på den polymertäckta elektroden. Mängden extraherad analyt ökade för längre uppkoncentreringstider. Desorptionen av den extraherade substansen genomfördes genom att polymeren reducerades, d.v.s. både extraktion och desorption kunde åstadkommas elektrokemiskt. Samma provupparbetningsprincip tillämpades i artikel V, där en elektrokemisk tunnskiktscell med en polypyrroltäckt arbetselektrod kopplades mot dels elektrosprayjonisation-masspektrometri (ESI-MS) och dels induktivt kopplat plasma (ICP) MS. Att direktkoppla ett elektrokemiskt system till ESI-MS innebär att man måste ta hänsyn till en hel del olika parametrar. Hela det elektrokemiska systemet måste skyddas från den höga (kV) potential som används för elektrosprayjonisering, och eventuell ledelektrolyt måste väljas noggrant då många salter har en negativ inverkan på joniseringsprocessen, och kan störa både känsligheten och spraystabiliteten. I artikel V, användes en isolationstransformator för att hålla all utrustning flytande på den p.g.a. elektrosprayspänningen inducerade potentialen. Extraktionsexperimenten visade sig dock vara svåra att genomföra då höga uppkoncentreringar ledde till att elektrosprayen kollapsade. Detta kan ha berott på att lösningens sammansättningen förändrades för mycket vid desorptionen. Kopplingen till ICP-MS var betydligt enklare då nebuliseringsprocessen inte påverkar EC-systemet, och eftersom ICP-tekniken och förstoftarna var mindre känsliga för icke-flyktiga mobilfaskomponenter. Dessa experiment visade att polypyrrol kan användas som ett generellt uppkoncentreringssteg för en analyt som inte lämpar sig för vanlig stripping- eller adsorptions-voltammetri. En modifierad cell användes även för att studera extraktion från lösningar innehållande olika analytkoncentrationer, och en ökad mängd interfererande anjoner. Resultaten visade att mängden extraherad analyt ökade med ökad koncentration. Polypyrrol har en ganska dålig selektivitet för anjoner av liknande karaktär. Det är därför ett material som med fördel kan användas för en generell uppkoncentrering av joner i flödessystem. Till sist utvecklades också ett PDMS mikrochip med integrerade guldelektroder. Utmaningarna med utvecklingen av detta miniatyriserade analyssystem var dels att integrera elektrosprayspetsen i chipets bulkmaterial, belägga spetsen med ett stabilt ledande skikt, samt att introducera elektroder i flödeskanalen. Utvecklingen av spetsen och de elektrokemiska stabilitetstesterna beskrivs i artikel IV. Som ledande material användes grafit, vilket visade sig vara mycket stabilt. Kronoamperometriexperiment visade att grafitmaterialet var stabilt i 40 minuter varefter strömtätheten minskade. Under ES-förhållanden tog det över 180 timmar innan elektrosprayströmmen avtog. 43 Strömminskningen berodde förmodligen på bildandet av ett passiviserande oxidskikt, och genom att reducera spetsen kunde strömmen regenereras. I artikel VI, redovisas en ny mikrofabriceringsteknik för att introducera elektroder i ett PDMS-chips kanalväggar. Elektroderna tillverkades genom att linda guldtrådar runt den stråltråd som användes för att gjuta själva kanalen. Detta visade sig vara ett snabbt och reproducerbart tillverkningsätt, vilket bekräftades i elektrokemiska utvärderingar av elektrodareorna. Direktkopplingen av chipet till ESI-MS, och elektrokemisk manipulation av en modellsubstans, dopamin, möjliggjordes genom att använda en batteridriven Blåtandsbaserad potentiostat. Denna direktkopplingslösning var mycket fördelaktig då potentiostaten kunde hanteras utan risk för elektriska stötar. Systemet visade sig även vara mycket effektivt, med en bra elektrokemisk konverteringsgrad och en mycket kort responstid. 44 9. References 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. B. E. Richter, B. A. Jones, J. L. Ezzel, and N. L. Porter, Anal. Chem., 1996, 68, 1033-1039. M-. L. Nilsson, M. Waldebäck, G. Liljegren. H. Kylin and K. E. Markides, Fresenius J. Anal. Chem., 2001, 370, 913-918. J-. F. Focant, C. Pirard and E. De Pauw, Talanta, 2004, 63, 11011113. V. Camel, Analyst, 2001, 126, 1182-1193. G. T. Tomy and G. A. Stern, Anal. Chem., 1999, 71, 4860-4865. M. Waldebäck, Licentiate Thesis, Uppsala 1998. K. Schäfer, Anal. Chim. Acta, 1998, 358, 69-77. R. P. Belardi and J. Pawliszyn, Water Pollut. Res. J. Canada, 1989, 24, 179-191. Z. Zhang, M. J. Yang and J. Pawliszyn, Anal. Chem., 1994, 66, 844853. Z. Zhang and J. Pawliszyn, Anal. Chem., 1993, 65, 1843-1852. R. Doong, S. Chang and Y. Sun, J. Chromatogr. Sci., 2000, 38, 528534. P. Landin, M. Llompart, M. Lourido and R. Cela, J. Microcolumn Sep., 2001, 13, 275-284. F. L. Cardinali, D. L. Ashley, J. V. Wooten, J. M. McCraw and S. W. Lemire, J. Chromatogr. Sci., 2000, 38, 49–54. J. P. Perez-Trujillo, S. Frias, M. J. Sanchez, J. E. Conde and M. A. Rodrigues-Delgado, Chromatographia, 2002, 56, 191-197. D.C. Stahl and D.C. Tilotta, Environ. Sci. & Technol., 2001, 35, 35073512. M. Llompart, M. Lourido, P. Landin, C. Garcia-Jares and R. Cela, J. Chromatogr. A, 2002, 963, 137-148. P. Popp, K. Kalbitz and G. Oppermann, J. Chromatogr., 1994, 687, 133-140. T. Górecki, X. Yu and J. Pawliszyn, Analyst, 1999, 124, 643-649. P. W. Atkins, Physical Chemistry, Oxford University Press, Oxford, 5th ed, 1994, p. 987. L. Müller, T. Górecki and J. Pawliszyn, Encyclopedia of Analytical Chemistry, John Wiley & Sons Ltd, England, 2000, p. 1-16. J. Chongrong, L. Yuzhong and L. Pawliszyn, J. Microcolumn Sep., 1998, 10, 167-173. 45 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. 41. 42. 43. 44. 45. 46. 46 T. P. Gbatu, O. Ceylan, K. L. Sutton, J. F. Rubinson, A. Galal, J. A. Caruso and H. B. Mark Jr, Anal. Commun., 1999, 36, 203-205. G. Vas and K. Vékey, J. Mass Spectrom., 2004, 39, 233-254. J. Wu and J. Pawliszyn, Anal. Chim. Acta. 2004, 520, 257-264. J. Wu, W. M. Mullet and J. Pawliszyn, Anal. Chem., 2002, 74, 48554859. J. Wu, X. Yu, H. Lord and J. Pawliszyn, Analyst, 2000, 125, 391-394. U. Tamer, B. Yates, A. Galal, T. Gbatu, R. LaRue, C. Schmiesing, K. Temsamani, Ö. Ceylan and H. B. Mark Jr, Microchim. Acta, 2003, 143, 205-215. S. Ulrich, J. Chromatogr. A. 2000, 902, 167-194. D. S. Peterson, Lab Chip, 2005, 5, 132-139. Y. Zang, J. Zhu, L. Zang and W. Zang, Anal. Chem., 2000, 72, 57445747. C. R. Cabrera and P. Yager, Electrophoresis, 2001, 22, 355-362. C. Yu, M. H. Davey, F. Svec and J. M. J. Fréchet, Anal. Chem., 2001, 73, 5088-5096. J. P. Kutter, S. C. Jacobson and J. M. Ramsey, J. Microcolumn Sep., 2000, 12, 93-97. R. D. Oleschuk, L. L. Shultz-Lockyear, Y. Ning and D. J. Harrison, Anal. Chem., 2000, 72, 585-590. R. Kalvoda, Electroanalysis, 2000, 12, 1207-1210. W. R. Vandaveer IV, S. A. Pasas, R. S. Martin and S. M. Lunte, Electrophoresis, 2002, 23, 3667-3677. K. Stulik, C. Amatore, K. Holub, V. Marecek and W. Kutner, Pure Appl. Chem., 72, 2000, 1483-1492. A. J. Bard and L. R. Faulkner, Electrochemical MethodsFundamentals and Applications, John Wiley & Sons, New York, 1980. L. X. Wang, X. G. Li and Y. L. Yang, React.Funct.Polym., 2001, 47, 125-139. M. P. Stevens, Polymer Chemistry, 3rd Ed., Oxford University Press, New York, 1999, p 412. D. Walton and P. Lorimer, Oxford Chemistry Primers, vol. 85, Polymers, Oxford University Press Inc., New York, 2000, p. 135. M. R. Nateghi, A. Bagheri, A. Massoumi and M. H. Kazemeini, Synth. Met., 1998, 96, 209-212 T. Nagaoka, H. Nakao, T. Suyama, K. Ogura, M. Oyama and S. Okazaki, Anal. Chem., 1997, 69, 1030-1037. J. Tamm, A. Alumaa, A. Hallik and V. Sammelselg, J. Electroanal. Chem., 1998, 448, 25-31. B. Fabre, J. Simonet, Coord. Chem. Rev., 1998, 178-180, 1211-1250. T. Shimidzu, A. Ohtani, T. Iyoda and K. Honda, J. Electroanal. Chem., 1987, 224, 123-135. 47. 48. 49. 50. 51. 52. 53. 54. 55. 56. 57. 58. 59. 60. 61. 62. 63. 64. 65. 66. 67. 68. 69. 70. 71. 72. 73. 74. 75. 76. T. Nagaoka, M. Fujimoto, H. Nakao, K. Kakuno, J. Yano and K. Ogura, J. Electroanal. Chem., 1994, 364, 179-188. R. S. Deinhammer, M. D. Porter and K. Shimazu, J. Electroanal. Chem., 1995, 387, 35-46. F. Y. Song and K. K. Shiu, J. Electroanal. Chem., 2001, 498, 161170. R. John, D. M. Ongarato and G. G. Wallace, Electroanalysis, 1996, 8, 623-629. O. A. Sadik and G. G. Wallace, Electroanalysis, 1994, 6, 860-864. J. N. Barisci, G. G. Wallace and A. Clarke, Electroanalysis, 1997, 9, 461-467. E. W. H. Jager, E. Smela and O. Inganäs, Science, 2000, 290, 15401545. G. Liljegren, J. Pettersson, K. E. Markides and L. Nyholm, Analyst, 2002, 127, 591-597. J. Wu, W. M. Mullet and J. Pawliszyn, Anal. Chem., 2002, 74, 48554859. T. W. Lewis, G. G. Wallace and M. R. Smyth, Analyst, 1999, 124, 213-219. C. Weidlich, K. M. Mangold and K. Jütter, Synth. Met., 2001, 119, 263-264. J. Wang, M. Jiang and B. Mukherjee, Anal. Chem., 1999, 71, 40954099. A. Ivaska, Electroanalysis, 1991, 3, 247-254. T. Silk and J. Tamm, Electrochim. Acta, 1996, 41, 1883-1885. Y. Li and R. Qian, J. Electroanal. Chem., 1993, 362, 267-272. H. Yang and J. Kwak, J. Phys. Chem. B, 1997, 101, 4656-4661. S. B. Saidman, Electrochim. Acta, 2003, 48, 1719-1726. B. Deore, H. Yakabe, H. Shiigi and T. Nagaoka, Analyst, 2002, 127, 935-939. H. S. Lee and J. Hong, Synth. Met., 2000, 113, 115-119. D. V. Andreeva, Z. Pientka, L. Brozová, M. Bleha, G. A. Polotskaya and G.K. Elyashevich, Thin Solid Films, 2002, 406, 54-63. Y. Li and J. Ouyang, Synth. Met., 2000, 113, 23-28. A. M. Farrington and J. M. Slater, Electroanalysis, 1997, 9, 843-847 O. A. Sadik and G. G. Wallace, Electroanalysis, 1993, 5, 555-563. J. Wu and J. Pawliszyn, J. Chromatogr., 2001, 909, 37-52. J. A. Harnisch and M. D. Porter, Analyst, 2001, 126, 1841-1849. H. Chriswanto and G. G. Wallace, J. Liq. Chromatogr., 1996, 19, 2457-2476. C. Ehrenbeck and C. Jüttner, Electrochim. Acta, 1996, 41, 511-518. C. Ehrenbeck and C. Jüttner, Electrochim. Acta, 1996, 41, 1815-1823. Y. Ikariyama, C. Galiatsamos and W. R. Heineman, Sens. Actuators, 1987, 12, 455-461. N. C. Foulds and C. R. Lowe, Anal. Chem., 1988, 60, 2473-2478. 47 77. 78. 79. 80. 81. 82. 83. 84. 85. 86. 87. 88. 89. 90. 91. 92. 93. 94. 95. 96. 97. 98. 48 Rajesh, S. S. Pandey, W. Takashima and K. Kaneto, Curr. Appl. Phys., 2005, 5, 184-188. R. John, M. J. Spencer, M. Smyth and G. G. Wallace, Anal. Chim. Acta., 1991, 249, 38-1-385. R. E. Ionescu, C. Gondran, L. A. Gheber, S. Cosnier and R. S. Marks, Anal. Chem., 2004, 76, 6808-6813. E. Smela, J. Micromech. Microeng., 1999, 9, 1-18. A. Manz, N. Graber and H. M. Widmer, Sens. Actuators B, 1990, 1, 244-248. M. Krishnan, V. Namasivayam, R. Lin, R. Pal and M. A. Burns, Curr. Opin. Biotech., 2001, 12, 92-98. D. R. Reyes, D. Iossifidis, P-. A. Auroux and A. Manz, Anal. Chem., 2002, 74, 2623-2636. P-. A. Auroux, D. Iossifidis, D. R. Reyes and A. Manz, Anal. Chem., 2002, 74, 2637-2652. R. Bodor, V. Madajová, D. Kaniansky, M. Masár, M. Jöhnck and B. Stanislaski, J. Chromatogr. A, 2001, 916, 155-165. J. P. Murrihy, M. C. Breadmore, A. Tan, M. McEnery, J. Alderman, C. O´Mathuna, A. O´Neill, P. O´Brien, N. Advoldvic, P. R. Haddad and J. D. Glennon, J. Chromatogr. A, 2001, 924, 233-238. A. G. Hadd, S. C. Jacobson and J. M. Ramsey, Anal. Chem., 1999, 71, 5206-5212. M. T. Blom, E. Chmela, J. G. E. Gardeniers, R. Tijssen, M. Elwenspoek and A. van den Berg, Sens. Actuators, B, 2002, 82, 111-116. J. P. Kutter, S. C. Jacobson, N. Matsubara and J. M. Ramsey, Anal. Chem., 1998, 70, 3291-3297. B. He, N. Tait and F. Regnier, Anal. Chem., 1998, 70, 3790-3797. J. Wang, M. P. Chatrathi, B. Tian, R. Polsky, Anal. Chem., 2000, 72, 5285-5289. M. Ueda, Y. Kiba, H. Abe, A. Arai, H. Nakanishi and Y. Baba, Electrophoresis, 2000, 21, 176-180. S. R. Liu, Y. N. Shi, W. W. Ja and R. A. Mathies, Anal. Chem., 1999, 71, 566-573. M. Zuborova, M. Masar, D. Kaniansky, M. Johnck and B. Stanislaski, Electrophoresis, 2002, 23, 774-781. D. R. Reyes, D. Iossifidis, P. A. Auroux and A. Manz, Anal. Chem., 2002, 74, 2623-2636. F. Mallard, G. Marchand, F. Ginot and R. Campagnolo, Biosens. Bioelectron., 2005, 20, 1813-1820. A. Arora, A. J. de Mello, A. Manz, Anal. Commun., 1997, 34, 393395. Å. Richard, O. Klett, C. Strandman, Y. Bäcklund and L. Nyholm, MEMS ASME International Mechanical Engineering Congress and Exposition, 1999, 1, 511-516. 99. 100. 101. 102. 103. 104. 105. 106. 107. 108. 109. 110. 111. 112. 113. 114. 115. 116. 117. 118. 119. 120. 121. 122. Y. Liu, R. S. Foote, S. C. Jacobson, R. S. Ramsey and J. M. Ramsey, Anal. Chem., 2000, 72, 4608-4613. Q. Mao and J. Pawliszyn, Analyst, 1999, 124, 637-641. A. J. Mello, Lab Chip, 2001, 1, 7N-12N. R. M. Wightman and D. O. Wipf, in A. J. Bard, Electroanalytical Chemistry, Vol. 15, Marcel Dekker, New York, 1989. J. Hjelm, Conducting Polymers Containing In-Chain Metal Centers, Ph.D. Thesis, Uppsala 2003. F. M. Matysik, F. Björefors and L. Nyholm, Anal. Chim. Acta, 1999, 385, 1999. F. Björefors, C. Strandman and L. Nyholm, Electroanalysis, 2000, 12, 255-261. M. Madou, Fundamentals of microfabrication, CRC Press LLC, Florida, 1997. H. Becker and L. E. Locascio, Talanta, 2002, 56, 267-287. J. C. McDonald, D. C. Duffy, J. R. Anderson, D. T. Chiu, H. Wu, O. J. A. Schueller and G. M. Whitesides, Electrophoresis, 2000, 21, 2740. H. Makamba, J. H. Kim, K. Kim, N. Park and J. H. Hahn, Electrophoresis, 2003, 24, 3607-3619. J. C. McDonald and G. M. Whitesides, Accounts of Chem. Research, 2002, 35, 491-499. C-. H. Chiou, G-. B. Lee, H-. T. Hsu, P-. W. Chen and P-. C. Liao, Sens. Actuators B, 2002, 86, 280-286. N. Xu, Y. Lin, S. A. Hofstadler, D. Matson, C. J. Call and R. D. Smith, Anal. Chem., 1998, 70, 3553-3556. W. R. Vandaveer IV, S. A. Pasas-Farmer, D. J. Fisher, C. N. Frankenfeld and S. M. Lunte, Electrophoresis, 2004, 25, 3528-3549. M. Dole, L. L. Mack, R. L. Hines, R. C. Mobley, L. D. Ferguson and M. B. Alice, J. Chem. Phys., 1968, 49, 2240-2249. M. S. Wilm and M. Mann, Int. J. Mass Spectrom., 1994, 136, 167180. P. Kebarle, J. Mass Spectrom., 2000, 35, 804-817. R. D. Smith, C. J. Barinaga and H. R. Udseth, Anal. Chem., 1988, 60, 1948-1952. E. D. Lee, W. Mueck, J. D. Henion and T. R. Covey, Biomed. Environ. Mass Spectrom., 1989, 18, 844-850. J. A. Olivares, N. T. Nguyen, C. R. Yonker and R. D. Smith, Anal. Chem, 1987, 59, 1230-1232. Z. Meng, S. Qi, S. A. Soper and P. A. Limbach, Anal. Chem., 2001, 73, 1286-1291. D. Figeys, R. Aebersold and C. J. Lock, J. Capillary Electrophor. Microchip Technol., 1999, 6, 1-6. A. Chartogne, U. R. Tjaden and J. Van der Greef, Rapid Commun. Mass Spectrom., 2000, 14, 1269-1274. 49 123. A. Pettersson Dahlin, M. Wetterhall, G. Liljegren, S. K. Bergström, P. Andrén, L. Nyholm, K. E. Markides and J. Bergquist, Analyst, 2005, 130, 193-199. 124. G. J. Van Berkel, and F. Zhou, Anal. Chem., 1995, 67, 2916-2923. 125. H. J. Issaq, G. M. Janini, K. C. Chan and T. D. Veenstra, J. Chromatogr. A. 2004, 1053, 37-42. 126. D. R. Barnidge, S. Nilsson and K. E. Markides, Anal. Chem., 1999, 71, 4115-4118. 127. S. Nilsson and K. E. Markides, Rapid Commun. Mass. Spectrom., 2000, 14, 6-11. 128. U. Selditz, S. Nilsson, D. Barnidge and K. E. Markides, Chimia, 1999, 53, 506-510. 129. S. Nilsson, M. Wetterhall, J. Bergquist, L. Nyholm and K. E. Markides, Rapid Commun. Mass Spectrom., 2001, 15, 1997-2000. 130. M. Svedberg, A. Pettersson, S. Nilsson, J. Bergquist, L. Nyholm, F. Nikolajeff and K. Markides, Anal. Chem., 2003, 75, 3934-3940. 131. S. Nilsson, M. Svedberg, J. Pettersson, F. Björefors, K. Markides and L. Nyholm, Anal. Chem., 2001, 73, 4607-4616. 132. M. Wetterhall, O. Klett, K. E. Markides, L. Nyholm and J. Bergquist, Analyst, 2003, 128, 728-733. 133. S. Bruckenstein and R. R. Gadde, J. Am. Chem. Soc., 1971, 93, 793794. 134. J. Willsau and J. Heitbaum, J. Electroanal. Chem., 1984, 161, 93-101. 135. K. Volk, R. Yost and A. Brajter-Toth, J. Electrochem. Soc., 1987, 134, C500-C500. 136. G. Diehl and U. Karst, Anal. Bioanal. Chem., 2002, 373, 390-398. 137. G. Hambitzer and J. Heitbaum, Anal. Chem., 1986, 58, 1067-1070. 138. A. M. Bond, R. Colton, A. D’Agostino, A. J. Downard and J. C. Traeger, Anal. Chem., 1995, 67, 1691-1695. 139. T. Y. Zhang, S. P. Palii, J. R. Eyler and A. Brajter-Toth, Anal. Chem., 2002, 74, 1097-1103. 140. X. Xu, W. Lu and R. B. Cole, Anal. Chem., 1996, 68, 4244-4253. 141. H. Deng and G. J. Van Berkel, Anal. Chem., 1999, 71, 4284-4293. 142. F. Zhou and G. J. Van Berkel, Anal. Chem, 1995, 67, 3643-3649. 143. J. R. Pretty and G. J. Van Berkel, Rapid Commun. Mass Spectrom, 1998, 12, 1644-1652. 144. C. F. Bökman, C. Zettersten, P. J. R. Sjöberg and L. Nyholm, Anal. Chem, 2004, 76, 2017-2024. 145. L. Tang and P. Kebarle, Anal. Chem., 1993, 65, 3654-3668. 146. R. S. Houk, V. A. Fassel, G. D. Flesch and H. J. Svek, Anal. Chem., 1980, 52, 2283-2289. 147. J. W. Olesik, Anal. Chem., 1991, 63, 12A-21A. 148. D. A. Skoog and J. J. Leary, Principles of Instrumental Analysis, 4th ed, Saunders Collage Publishing, Chicago, 1992, p234-236. 50 149. C. A. Ponce de León, M. Montes-Bayón and J. A. Caruso, J. Chromatogr. A, 2002, 974, 1- 21. 150. D. Beauchemin, Anal. Chem., 2004, 76, 3395-3416. 151. K. Sutton, R. M. C. Sutton and J. A. Caruso, J. Chromatogr. A, 1997, 789, 85-126. 152. A. L. Rosen and G. M. Hieftje, Spectrochim. Acta, B, 2004, 59, 135146. 153. X. Bu, T. Wang and G. Hall, J. Anal. At. Spectrom., 2003, 18, 14431451. 154. E. H. Larsen, Spectrochim. Acta, B, 1998, 53, 253-265. 155. T.- J. Hwang and S.- J. Jiang, J. Anal. At. Spectrom., 1996, 11, 353357. 156. J. R. Pretty, D. C. Duckworth and G. J. Van Berkel, Anal. Chem., 1997, 69, 3544-3551. 157. A. J. Baca, A. B. De La Ree, F. Zhou and A. Z. Mason, Anal. Chem., 2003, 75, 2507-2511. 158. J. R. Pretty, G. J. Van Berkel and D. C. Duckworth, Int. J. Mass. Spectrom., 1998, 178, 51-63. 159. J. R. Pretty, E. A. Blubaugh and J. A. Caruso, Anal. Chem., 1993, 65, 3396-3404. 160. J. R. Pretty, E. A. Blubaugh, J. A. Caruso and T. M. Davidsson, Anal. Chem., 1994, 66, 1540-1547. 161. J. R. Pretty, D. C. Duckworth and G. J. Van Berkel, Anal. Chem., 1997, 69, 3544-3551. 51 Acta Universitatis Upsaliensis Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology 54 Editor: The Dean of the Faculty of Science and Technology A doctoral dissertation from the Faculty of Science and Technology, Uppsala University, is usually a summary of a number of papers. A few copies of the complete dissertation are kept at major Swedish research libraries, while the summary alone is distributed internationally through the series Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology. (Prior to January, 2005, the series was published under the title "Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology".) Distribution: publications.uu.se urn:nbn:se:uu:diva-5807 ACTA UNIVERSITATIS UPSALIENSIS UPPSALA 2005