APPLICABLE LOCATIONS
Transcription
APPLICABLE LOCATIONS
APPLICABLE LOCATIONS ADELAIDE Unit 2 1 Burma Road Pooraka Adelaide SA 5095 P: +61 8 8162 5130 ALSEnviro.Adelaide@alsglobal.com BRISBANE 2 Byth St Stafford QLD 4053 (Corner of Byth & Shand Streets) P: +61 7 3243 7222 ALSEnviro.Brisbane@alsglobal.com CHINCHILLA 20b Malduf Street Chinchilla QLD 4413 P: +61 7 4665 5770 ALSEnviro.Chinchilla@alsglobal.com DARWIN 4/16 Charlton Court, Woolner NT 0820 P: +61 488 073 271 ALSEnviro.Darwin@alsglobal.com EMERALD 6-8 McCosker Street Emerald QLD 4720 P: +61 7 4988 2600 ALSEnviro.Emerald@alsglobal.com GLADSTONE 48 Callemondah Drive Clinton Gladstone QLD 4680 P: +61 7 4971 5600 ALSEnviro.Gladstone@alsglobal.com MACKAY 78 Harbour Road Mackay QLD 4740 P: +61 7 4944 0177 ALSEnviro.Mackay@alsglobal.com MELBOURNE 2 - 4 Westall Road Springvale VIC 3171 P: +61 3 8549 9600 ALSEnviro.Melbourne@alsglobal.com MUDGEE 29 Sydney Road Mudgee NSW 2850 P: +61 2 6372 6735 ALSEnviro.Mudgee@alsglobal.com NEWCASTLE Unit 5, 585 Maitland Road Mayfield West NSW 2304 P: +61 2 4014 2500 ALSEnviro.Newcastle@alsglobal.com NOWRA 4/13 Geary Place North Nowra NSW 2541 P: +61 2 4423 2063 ALSEnviro.Nowra@alsglobal.com PERTH 10 Hod Way, Malaga WA 6090 P: +61 8 9209 7655 ALSEnviro.Perth@alsglobal.com ROMA Lot 4, 73 Beaumont Drive Roma QLD 4455 P: +61 7 4622 8978 ALSEnviro.Roma@alsglobal.com SYDNEY 277-289 Woodpark Road Smithfield NSW 2164 P: +61 2 8784 8555 ALSEnviro.Sydney@alsglobal.com TOWNSVILLE 14-15 Desma Court Bohle QLD 4818 P: +61 7 4796 0600 ALSEnviro.Townsville@alsglobal.com WOLLONGONG 99 Kenny Street Wollongong NSW 2500 P: +61 2 4225 3125 ALSEnviro.Wollongong@alsglobal.com Water Resources Group (WRG) operations utilise an alternate pocket guide For the latest information, locations and services visit www.alsglobal.com WATER WATER WATER SOLIDS SOLIDS SOLIDS SOLIDS AIR/DUST SULFIDE SULFITE AOX/TOX PARTICLE SIZE or ASBESTOS SOIL PARAMETERS SEDIMENT PARAMETERS ACID SULFATE SOILS DUSTS AIR/SOIL GAS VOCs (via Canister) SAMPLE CONTAINER SAMPLE CONTAINER SAMPLE CONTAINER SAMPLE CONTAINER SAMPLE CONTAINER SAMPLE CONTAINER SAMPLE CONTAINER SAMPLE CONTAINER SAMPLE CONTAINER 125mL Plastic Bottle 250mL Plastic Bottle 500mL Amber Glass Bottle 100mL, 250mL or 500mL Zip Lock Plastic Bag 150ml soil container with Teflon lined lids 250mL Glass Jar, Teflon Lined Lid 250mL Plastic Bag 4L Glass Winchester Passivated Canisters (1.4, 3 & 6L) PRESERVATION PRESERVATION PRESERVATION PRESERVATION PRESERVATION PRESERVATION PRESERVATION PRESERVATION PRESERVATION Zinc Acetate + Sodium Hydroxide (NaOH) Chill to ≤6° EDTA + Zinc Acetate Chill to ≤6° Nitric Acid (plus Sodium Thiosulfate for Chlorinated water) Chill to ≤6° ANALYTES Nil Nil, Chill to ≤6°C Nil, Chill to ≤6°C Nil, Freeze or submit within 24 hours of sampling Copper Sulfate (CuSO4) Nil ANALYTES ANALYTES ANALYTES ANALYTES ANALYTES ANALYTES AOX (one bottle) EOX (two bottles) Particle Size Distribution or Asbestos All parameters excluding ASS, Sizings & Asbestos Separate jars should be provided for Dioxins, PBDEs, PFOS/AFFFs, Explosives, ZHE Extracts or Herbicides Common NAGD organic & inorganic suites excluding sizing, Ecotox & Elutriates SPOCAS Chromium Suite CRS TOS NAPP/NAG Total Solids Soluble, Insoluble & Combustible Matter Ash Content Calculated Rainfall Various Metals in dust VOCs by TO14, TO15 ANALYTES ANALYTES Sulfide Sulfite, This bottle is also suitable for Thiosulfate analysis NOTES NOTES NOTES NOTES NOTES NOTES NOTES NOTES NOTES Fill to Zero Headspace minimising exposure to air. For Dissolved Sulfide, add sample to an Aluminium Chloride dosed container, stand 5 to 15 minutes then decant supernatant into the sulfide bottle. Fill bottle to Zero Headspace minimising exposure to air. Fill to Zero Headspace minimising exposure to air. Asbestos sample volumes: Bulk Materials & Pres/Abs in soil – 100mL. Friable Asbestos in Soil sieved to 7mm – 500mL. Full Quantitation – Pre-sieved Soil & ACM to 7mm –100mL or FA in soil – 500mL or up to 10L of soil. All double bagged & sealed inside a rigid container. 150mL jar is sufficient for all routine soil analysis + one ASLP or TCLP leach. Two jars are recommended for multiple leachates including ZHE. Contact ALS for Elutriate & Pore water testing sample requirements. Unless requested otherwise, Acid Sulfate soils will be automatically dried & prepared upon receipt to facilitate extended holding times. Please provide field data via COC (start/finish dates & funnel diameter if not 150mm). 3L & 6L canisters for ambient air. 1.4L canisters for soil gas. Canisters must be returned to ALS within 2 weeks of supply. HOLDING TIME HOLDING TIME HOLDING TIME HOLDING TIME HOLDING TIME HOLDING TIME HOLDING TIME HOLDING TIME HOLDING TIME 7 days 2 days 6 months Indefinite Inorganics generally: 7-28 days. Mercury & Hex’ Chromium: 28 days. VOC/SVOC: 7-14 days Other Metals: 6 months Generally 14 days except Mercury (28 days) & Metals (6 months) Unfrozen – 24 hours Frozen – Indefinite 30 days TO14: 30 days TO15: 14 days YELLOW FLUORO ORANGE RED BLACK ON WHITE ORANGE ORANGE GREEN AQUA BLACK ON WHITE IMPORTANT INFORMATION GENERAL > This pocket guide is to be used for Australian Environmental operations excluding WRG operations in Melbourne, Canberra and Regional Victoria. ALS has a comprehensive range of drinking, recycled and desalination water analytical services available on request, which are not covered in this pocket guide. Please contact ALS for assistance. Eskies and ice bricks plus labelled pre-dosed colour-coded sample containers are provided for all analyses conducted by ALS. ALS Client Services are available to assist and provide guidance as required. CONTAINER VOLUME AND QUALITY CONTROL REQUIREMENTS > Some containers exist in several sizes to accommodate varying suites of analyses while focusing on minimizing weight (OH&S and sampling benefits). Please refer to the notes section under each sample container. > Current NEPM Laboratory QC requirements are to perform 1 in 10 duplicates and 1 in 20 matrix spikes. ALS performs QC based upon the dominant batch within the QC lot. Batches of 10 or more waters should have sufficient bottles provided for duplicate matrix and spike analyses. SAMPLE COLLECTION POCKET GUIDE SAMPLING AND PRESERVATION > Care must be taken not to rinse out or spill preservatives during sampling for OH&S reasons and to avoid cross contaminating other bottles (e.g. Nitric acid used for metals can contaminate nitrate analysis). Field filtration is mandatory or recommended for many tests and other tests must have exposure to air minimised to avoid analyte losses. > Samples should generally be chilled to <4˚C or <6˚C (guideline dependent) and transported to the laboratory within 24 hours. ALS recommends placing samples in ice immediately upon sampling for best practice chilling, with either repacking into another esky or draining of free water and replacement of ice just prior to dispatch. > Chilling overnight in a fridge may also benefit. The post-chilling addition of ice bricks is also recommended where samples are air freighted or dispatched long distance and where couriers will not freight ice. > Samples taken from chlorinated water sources require the addition of sodium thiosulfate for microbiological, volatile organics and semi volatile organics. > Please advise ALS accordingly to facilitate supply of appropriate containers. HEALTH AND SAFETY > Although the quantities of preservative dosed into containers is minimal, it is important to observe safe chemical handling practices while using bottles. Use of appropriate Personal Protection Equipment such as gloves and safety glasses is recommended. > Bottle labels indicate preservative type, risk and safety information and first aid instructions. Material Safety Data Sheets are available on the ALS Website or can be provided upon request along with Safety information and First Aid instructions. > Due to airfreight protocols, containers preserved with nitric or hydrochloric acid or Sodium Hydroxide should not be shipped by air unless under DG protocols. HOLDING TIMES > ALS recommended holding times are indicated. Failure to comply with these Holding Times may impact data validity. Samples and COCs should be submitted (preferrably by email from remore locations to assist login) with at least half the analytical holding time remaining unless prior arrangements are made otherwise. Short holding times are shaded in yellow to assist. September 2014 RIGHT SOLUTIONS | RIGHT PARTNER AIRFREIGHT OPTION WATER VOC WATER WATER SVOC (100ml) SVOC (500ml) SAMPLE CONTAINER Pair of 40mL Amber Glass Vials with Teflon Lined Septa SAMPLE CONTAINER 100mL Amber Glass Bottle with Teflon Lined Cap PRESERVATION Sulfuric Acid for airfreight Chill to ≤6° PRESERVATION Nil Chill to ≤6° ANALYTES TPH/TRH (C6-C10) plus BTEX, BTEXN, VOCs (MAHs, VHC & THMs) or Alcohols or 1,4-Dioxane, Acrylonitrile & Pyridine or Methane plus gases WATER AFFF’s PFOS/PFOA WATER METALS SULFIDE PRE-TREAT AIRFREIGHT OPTION WATER HEXAVALENT CHROMIUM WATER FERROUS IRON WATER WATER ULTRA-TRACE ORC METALS SPECIATED ARSENIC & SELENIUM WATER WATER WATER WATER WATER CYANIDES GENERAL WATER QUALITY GENERAL WATER QUALITY SELECT NUTRIENTS TOC / DOC WATER SAMPLE CONTAINER SAMPLE CONTAINER 60 mL or 125mL Plastic Bottle 60mL Plastic Bottle or 1L-5L for Radionuclides SAMPLE CONTAINER 60mL Plastic Bottle SAMPLE CONTAINER 60mL Plastic Bottle SAMPLE CONTAINER 60 mL Plastic Bottle SAMPLE CONTAINER 60mL Plastic Bottle SAMPLE CONTAINER 60mL Opaque Plastic Bottle Cyanate requires a separate 60ml bottle SAMPLE CONTAINER 125ml Plastic Bottle 250mL Plastic Bottle SAMPLE CONTAINER 500mL or 1000ml for Low Level TDS/TSS only SAMPLE CONTAINER 60mL or 125mL Plastic Bottle 250mL bottle for Thiocyanate SAMPLE CONTAINER 40mL Amber Glass Vial, Teflon Lined Septa SAMPLE CONTAINER 250mL Wide Mouth Glass Jar PRESERVATION Nil Chill to ≤6° PRESERVATION Nitric Acid (HNO3) or Nil for Airfreight Chill to ≤6° PRESERVATION Sodium Hydroxide (trace NaOH) Chill to ≤6° PRESERVATION Hydrochloric Acid (HCl) Chill to ≤6° PRESERVATION Nil for Airfreight Chill to ≤6° PRESERVATION Hydrochloric Acid (HCl) Chill to ≤6° PRESERVATION Sodium Hydroxide (NaOH) (See notes below) Chill to ≤6° PRESERVATION Nil Chill to ≤6° PRESERVATION Nil Chill to ≤6° PRESERVATION Sulfuric Acid (H2SO4) Chill to ≤6° PRESERVATION Sulfuric Acid (H2SO4) Chill to ≤6° PRESERVATION Sodium Bisulphate Chill to ≤6° ANALYTES Standard level SVOC, TPH/TRH(C10-C40), PAH/Phenols, OC/OP Pesticides, & PCB’s or Speciated TPH/TRH (C10-C40) or Herbicides or Explosives or Carbamates or Glyphosate/AMPA ANALYTES UT PAH/Phenols + any standard level SVOCs, or UT OC/OP/PCBs or TBT or UT Explosives, or UT Herbicides/Multi-residues A pair for Dioxins or PBDEs or Steroids & PPCPs ANALYTES PFOS/PFOA/6:2 FTS or extended AFFF suite This bottle is also suitable for Paraquat & Diquat ANALYTES Metals – Dissolved or Total Radionuclides (1,000mL required for Gross Alpha/ Beta, Other Radionuclides – various (up to 5,000mL) ANALYTES Hexavalent Chromium Cr6+ ANALYTES Ferrous Iron ANALYTES All ultra-trace metals in fresh or saline water ANALYTES Speciated As & Se ANALYTES Free, WAD & Total Cyanide. Amenable Cyanide. Cyanate. For Thiocyanate – see the purple bottle ANALYTES Suite 1: Alkalinity, Conductivity, (2) (1) pH , Ammonia , Cations, Chloride, Sulfate, Fluoride, Hardness, Nitrate, Nitrite, Reactive P, Silica, plus TDS (Calc’ only), Acidity, 125mL (3) for perchlorate ANALYTES 500mL for Suite 1 plus Suite 2: (Colour, Turbidity, std level TDS & TSS) 1000mL for Suite 1&2 plus Suite 3: (low level TDS/TSS) ANALYTES 60mL for Suite 1: NOX, Ammonia and total Phenolics or TKN/TP and NOx. 125mL for Suite 2: NOX, TKN, TP, Ammonia, COD and total Phenolics, 250mL for Thiocyanate ANALYTES TOC or DOC ANALYTES Oil & Grease NOTES Fill to Zero Headspace minimising exposure to air. Hydrochloric Acid and Sodium Bisulphate is also acceptable for VOCs. NOTES 2 additional bottles are required for Lab QC (dups & matrix spikes). See notes overleaf. NOTES 2 additional bottles are required for Lab QC (dups & matrix spikes). See notes overleaf. NOTES Avoid contact with teflon (e.g. tubing or bailers) for PFOS/PFOA analysis. NOTES Field filtration is key for dissolved metals (confirm by COC & ticking bottle label). Red & green striped bottle for airfreighting or Radionuclides will be lab acidified. NOTES Field filtration is key for dissolved Cr6+ (confirm by COC & ticking label). Fill to Zero Headspace minimising exposure to air. NOTES Field filtration is mandatory (confirm by COC & ticking label). Fill to Zero Headspace minimising exposure to air. NOTES Field filtration is key for dissolved metals (confirm by COC & ticking label). Acidification with ultra pure HNO3 will occur upon receipt. NOTES Field Filtration is mandatory. Fill to Zero Headspace minimising exposure to air. NOTES If Sulfide is suspected, a (Blue & White) Sulfide PreTreatment bottle (containing Lead Acetate) should be used to remove sulfide prior to decanting into the cyanide bottle for dispatch to ALS. NOTES Ammonia can be analysed from this bottle if submitted within 12 hours of sampling & with prior arrangement with the laboratory. (2) Field pH is recommended due to holding times. (3) Perchlorate requires 0.2um field filtration and 50% headspace. NOTES Ammonia can be analysed from this bottle to extend holdings times. NOTES Field filtration is mandatory for DOC (confirm by COC & ticking label). NOTES 1 additional bottle required for QC lab dups. See notes overleaf. HOLDING TIME 7 to 14 days HOLDING TIME 7 days + 40 days for extracts HOLDING TIME 7 days + 40 days for extracts except Dioxins (1 year) HOLDING TIME 180 days Paraquat & Diquat (7 days) + 40 days for extracts’ HOLDING TIME 6 months except Hg, Cations: 28 Days Radionuclides – various HOLDING TIME 28 days HOLDING TIME 7 days HOLDING TIME 6 months except Hg: 28 days HOLDING TIME 28 days HOLDING TIME 14 days HOLDING TIME pH: 6 Hours Ammonia: 24 hours PO4, NO2, NO3, BOD, Colour, Turbidity, Formaldehyde: 2 days HOLDING TIME 28 days HOLDING TIME 28 days HOLDING TIME 28 days PURPLE ORANGE ORANGE GREY RED SAMPLE CONTAINER 500mL Amber Glass Bottle 100mL Amber Glass Bottle for Ethoylates PRESERVATION Nil, Chill to ≤6°C MAROON RED ON WHITE MAROON ON WHITE BLUE GREEN GREEN PURPLE PURPLE WATER SAMPLE CONTAINER 500mL White Plastic Bottle 1000mL White Plastic Bottle or filter paper for Chlorophyll PRESERVATION Algae Lugol’s Iodine solution or submit chilled within 12hrs Chlorophyll – Unfiltered, Chill to ≤6°C, Store in dark. Filtered, Store filter paper in dark at -20°C (Do not store in frost free freezer) ANALYTES ANALYTES Anionic Surfactants (MBAS) or Total Algae Non-Ionic Surfactants (NIS) or Predominant Genera Alkyl-Phenyl Ethoxylates Cyanobacteria (APE) or Chlorophyl a, b & C SAMPLE CONTAINER 250mL Sterile Plastic Bottle NOTES 2 additional bottles are required for Lab QC (dups & matrix spikes). See notes overleaf. Formaldehyde may be added upon receipt to extend holding times. HOLDING TIME 2 days NOTES Matrix – Fresh water only. NOTES Samples should be delivered to the lab within 12 hours of sampling. HOLDING TIME 6 months preserved with Lugol’s at 1% v/v ratio or 48 hours unpreserved. Chlorophyll Holding time 2 days unfiltered or 28 days filtered. HOLDING TIME 24 hours Ca, Mg, TSS, TDS: 7 days Alkalinity/Acidity: 14 days Others: generally 28 days BLUE WATER ALGAE OR MICROBIOLOGY OIL & GREASE SURFACTANTS CHLOROPHYLL SAMPLE CONTAINER 500mL Amber Glass Bottle or pair of bottles with Teflon Lined Cap PRESERVATION Nil Chill to ≤6° (1) WATER PURPLE BROWN DARK GREEN PRESERVATION Sodium Thiosulfate (Na2S2O3) as default bottle Chill to ≤6° ANALYTES 250mL = E Coli, Coliforms & HPC or Streptococci or HUB Legionellae, Enterococci, Pseudomonas GREY