AH-02120 Operating Manual For HORING LIH INDUSTRIAL CO., LTD
Transcription
AH-02120 Operating Manual For HORING LIH INDUSTRIAL CO., LTD
Operating Manual For AH-02120 HORING LIH INDUSTRIAL CO., LTD 2014E3 Multi-Hazard Suppression Control Panel A. System Features This compact and esthetic unit is ideally suited for variety of agent releasing applications such as FM-200, CO2, and Dry & Wet Chemical. Expansion is available in order to protect more areas. Auto and Manual operation for agent releasing. System enables highly reliable monitoring and suppression control for up to eight separate hazards. Audible and visible indication when system has fault condition. Digital Release Countdown. PA system supply seven sections of voice and its content can be customizing. 24 characters LCD and printer are available for optional selection. B. Control Board Features 1. Cross-zones detection to avoid false alarm. 2. Maintenance valve closed and system lock enable to avoid any dangerous from agent released during maintenance and test period. 3. Main bell can be silenced and will reactive when new alarm signal is issued. 4. 10seconds before PA Voice on 2nd stage (agent releasing), the digital release counter will start to countdown. 5. This unit has Emergency Stop & Start; it also can connect with external emergency initial device. Both buttons have protecting cover to avoid any false operation. 6. Hidden switch feature for system set-up a. Adjustable releasing countdown (00-99 seconds). b. Choice of releasing countdown from start or keep counting after Emergency Stop button released. c. Choice of releasing indicator output to active via press switch. d. Choice of printer (optional) 7. Status LED Indicators a. 8 disconnection & alarm indication b. CPU trouble indication c. Voltage abnormal indication d. Attention switch indication e. Switches of main bell, area bell, buzzer, electromagnetic valve, speaker, relay output, reset are use membrane type. 1 Multi-Hazard Suppression Control Panel C. Suppression System Flow Chart (Auto Operation) Fire Starts st 1 zone alarm False 2nd stage st Zone & 1 alarm LED st 2 nd zone alarm Buzzer output Pre-released announcement Zone & 2 alarm LED ON Release delay timer ON Valve activated LED ON 6th stage Electromagnetic valve 5 th stage 2nd alarm output nd 4th stage Main bell sound 3 rd stage 1 alarm signal output PA Voice System Activated Main bell activated 1st stage PA voice activated 7 th stage Agent released Pressure LED ON Releasing indicator ON PA voice system ON Fire extinguished Reset 2 Multi-Hazard Suppression Control Panel D. Manual Operation Fire Starts st Acknowledge False Alarm 1 zone alarm M.P.S. ON Main Bell Sound st Zone & 1 alarm LED ON Emergency release ON Alarm signal output 3 rd stage M.P.S. ON Pre-released announcement Bell Sound Emergency Start ON Releasing Timer Delay Timer Stop Stop (release) Electromagnetic valve ON 6th stage Stop (press) 5 th stage Relay Output 4th stage Buzzer ON 2nd stage Bell Sound PA Voice System Activated Open M.P.S. 1st stage PA announcement 7 th stage Agent Released Pressure Switch ON Releasing Indicator ON PA System ON Fire Distinguished Reset 3 Multi-Hazard Suppression Control Panel E. Content of PA Voice System 1 st stage ~ 7 th stage will depends on customer’s request. F. Specifications Supply Voltage AC 220V 50/60Hz Standby Voltage DC 24V 4Ah Loop Voltage DC 24V Others also available External Resistance Under 50Ω # Of Detector Heat detector – no limit Connected Smoke detector – 30/loop EOL Resistance 10KΩ Detection Type Cross-zone detection Dimensions H520mm x W390mm x D135mm Material 1.6mm steel plate Color Ivory white Except electronic type Size may vary depends on zones Other colors are available External Contacts : Electromagnetic Valve DC 24V Sounder DC 24V 200mA Releasing indicator DC 24V 200mA Manual Station RS485 transmission and up to 10 units/zone Alarm Bell DC 24V 200mA Speaker DC 12V (3W 8Ω / zone) 4 Multi-Hazard Suppression Control Panel G. Hidden Switches ON 1 2 561F Adjustable Countdown (0-99) Emergency Start / Stop Disable Device 1.Up: Releasing indicator output without pressure switch Down: Releasing indicator output via pressure switch 2.Up: Release countdown restart Down: Release countdown keep counting Printer ON/OFF Switch ON 1 5 Multi-Hazard Suppression Control Panel H. Wiring Diagram + LOOP 1 1A N.O. LA BELL LOOP 1 1B N.C. N.O. BUZZER + LOOP 2 1C COM. N.C. VALVE OFF LOOP 2 2A N.O. BZ VALEE ON V+ V+ 2B N.C. BA REL LAMP V- V- 2C COM. COM LOAD S+ S+ 3A N.O. S- S- 3B N.C. AU OUT SPEAKER SPEAKER PA STOP 3C COM. B+ BATT + ST START 4A N.O. B- BATT - DO DOOR 4B N.C. KEY A&M 4C COM. Zone 1 Zone 2 - COM AC AC IN EARTH AC PS PRESSURE SWITCH U1 MAINSYS U2 STANDBY COM 6 Multi-Hazard Suppression Control Panel Manual Pull Station V- S+ S- PA ST DO KEY COM EOLR V+ DETECTOR EOLR Pressure Switch L L L L Lc Lc Lc Lc EOLR Indicator DETECTOR EOLR L L L L Lc Lc Lc Lc To Indicators Device + + - To Relay Output Device 1 To Relay Output Device 2 To Relay Output Device 3 To Relay Output Device 4 LA 24V DC - Zone2 Zone1 1A NO 1B NC 1C COM 2A NO V+ V- S+ S- PA ST DO KEY COM PS U1 U2 COM 572B 2B NC 2C COM 3A NO 3B NC 4C COM 4A NO 4B NC ON ON 4C COM OFF OFF NO NC BZ BA COM AU OUT B+ B- To Buzzer & Valve Device Valve Battery AC IN 24V DC 7 Multi-Hazard Suppression Control Panel I. Monitoring Function List Relay Output Unit Control Panel Monitoring Content Central Monitor System Fault System Alarm Indication LED Visual Indication Audio Sound Indication 1 st zone alarm ▲ ▲ ▲ 2 nd zone alarm ▲ ▲ ▲ 1 st zone disconnection ▲ ▲ ▲ ▲ 2 nd zone disconnection ▲ ▲ ▲ ▲ Agent released ▲ Attention switch Power supply failed ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ Manual release Manual stop ▲ ▲ ▲ ▲ ▲ ▲ Auto/Manual ▲ ▲ Reset ▲ ▲ System fault ▲ ▲ Fuse fault ▲ ▲ ▲ Releasing indicator disconnection ▲ ▲ ▲ Manual pull station disconnection ▲ ▲ ▲ Speaker disconnection ▲ ▲ ▲ Bell disconnection ▲ ▲ ▲ Buzzer disconnection ▲ ▲ ▲ Maintenance Valve OFF Valve ▲ ▲ System Lock LOCK-OFF ▲ ▲ 8 Multi-Hazard Suppression Control Panel J. Simultaneous Output and Relay Output Power ON Panel Display AC power ON Auto LED ON Countdown setting Simultaneous Output Speaker output Electromagnetic valve Relay Output System Reset Auto Operation Panel Display Detection Zone Alarm Zone LED ON 1st Alarm LED ON Simultaneous Output Area Bell Speaker Main Bell ON 2 zones LED ON 1st Alarm LED ON Cross Zone Alarm 2nd Alarm LED ON Main Bell ON Start Countdown Agent Releasing System Reset Relay Output Zone Alarm 1st Alarm NO.NC.COM Area Bell Speaker Buzzer 2 Zones Alarm 1st Alarm 2nd Alarm NO.NC.COM 2 zones LED ON 1st Alarm LED ON 2nd Alarm LED ON Main Bell ON Start Countdown Pressure Switch ON Releasing Indicator ON Electromagnetic ON Area Bell Speaker Buzzer Electromagnetic Releasing Indicator 2 Zones Alarm 1st Alarm 2nd Alarm Pressure Switch Releasing Indicator NO.NC.COM AC Power ON Auto LED ON Countdown Set-up Speaker Electromagnetic System Reset 9 Multi-Hazard Suppression Control Panel K. Manual Operation Panel Display Simultaneous Output Relay Output Auto → Manual Manual LED ON Manual Pull Station M.P.S. LED ON Main Bell ON Alarm Bell Manual Pull Station Emergency Start M.P.S. LED ON Main Bell ON E. Start LED ON Start Countdown Alarm Bell Buzzer Speaker Manual Pull Station Emergency Start Emergency Stop (Press down) M.P.S. LED ON Main Bell ON E. Start LED ON Stop Countdown E. Stop LED ON Alarm Bell Buzzer Speaker Manual Pull Station Emergency Start Emergency Stop Emergency Stop (Release) M.P.S. LED ON Main Bell ON E. Start LED ON Start Countdown E. Stop LED ON Alarm Bell Buzzer Speaker Manual Pull Station Emergency Start Agent Released M.P.S. LED ON Main Bell ON E. Start LED ON Stop Countdown Pressure S.W. ON Releasing Ind. ON EM. Valve ON Alarm Bell Buzzer Speaker EM. Valve Releasing Indicator Manual Pull Station Emergency Start Pressure Switch Releasing Indicator Speaker EM. Valve System Reset System Reset AC Power ON Auto LED ON Countdown Set-up Manual Mode 10 Multi-Hazard Suppression Control Panel L. Wire Disconnection Panel Display Any Zone Disconnection Zone discon. ON Main bell ON Disconnection ON Simultaneous Output Relay Output Zone Disconnection MPS discon. ON Manual Pull Station Main bell ON Disconnection Disconnection ON Fault Pressure Switch Disconnection PS discon. ON Main bell ON Disconnection ON Fault Emergency Start Disconnection E. Start discon. ON Main bell ON Disconnection ON Fault Emergency Stop Disconnection E. Stop discon. ON Main bell ON Disconnection ON Fault EM. Valve Disconnection Output Fault ON Main Bell ON Fault Alarm Bell Disconnection Output Fault ON Main Bell ON Fault Buzzer Disconnection Output Fault ON Main Bell ON Fault Speaker Disconnection Output Fault ON Main Bell ON Fault System Lock Disconnection Output Fault ON Main Bell ON Disconnection Maintenance Valve Output Fault ON Disconnection Main Bell ON Disconnection 11 Multi-Hazard Suppression Control Panel M. Others Panel Display Simultaneous Output Relay Output Back-up power ON System fault ON Main bell ON System fault Attention switch Switch Not On Position Attention SW. ON (Area bell SW. ON) (Buzzer SW. ON) (E. valve SW. ON) (PA SW. ON) Relay Output Attention SW. ON Relay output SW. ON Power Failure CPU Fault System fault ON System fault 12 Multi-Hazard Suppression Control Panel N. Simple Trouble Shooting Symptom Solution AC power OFF Check AC power switch Check AC power fuse Back-up power OFF Check battery Disconnection ON Check wiring connection NO relay output Check relay output switch Check wiring connection NO PA output Check PA switch Check wiring of speaker NO area bell output Check area bell switch Check wiring NO buzzer output Check buzzer switch Check wiring NO main bell output Check main bell switch Attention SW. ON Check all switches Emergency stop LED ON Check manual pull station and control board for STOP button Emergency start LED ON Check manual pull station and control board for START button Manual pull station LED ON Check manual pull station if it is well closed O. Maintenance a. Control Unit 1. Normal – AC power ON 2. Power-off – DC power ON b. General 1. System should be inspected annually and all the recorded data should well keep by responsible department or person. 2. During maintenance, control system or maintenance valve may need shout off depends on site situation. 13 Multi-Hazard Suppression Control Panel AH-02120 Multi-Hazard Suppression Control Panel HORING LIH INDUSTRIAL CO., LTD 2014