WIN-PAK PE API ® Application Programming Interface (API)
Transcription
WIN-PAK PE API ® Application Programming Interface (API)
WIN-PAK® PE API Application Programming Interface (API) Honeywell’s WIN-PAK® software suite provides a range of solutions from access control only to fully integrated security solutions. WIN-PAK’s powerful user interface allows integrators to install a single software for all of their customers’ security needs. When using WIN-PAK's excellent access control functionality, certain applications require connectivity to third party systems, where multi-technology and multi-brand integration is needed. WIN-PAK PE (Professional Edition) API provides the interface between WIN-PAK SE 4.0/PE 4.0 and third party systems, such as Human Resources (HR) systems or software monitoring platforms. The API is a tool for software developers, with Visual C++ programming knowledge, that allows WIN-PAK to be connected with the client system. The API operates with the access control part of WIN-PAK only and consists of two parts: Database API: This API provides the tools to add, delete and modify the WIN-PAK database records, such as card holder and card information, access levels, holidays and time zones. Communication API: This API provides the programming interface to monitor and control the access control hardware devices and elements, such as access control panels, inputs, outputs and readers. WIN-PAK PE API optimises system performance between WIN-PAK PE 4.0 and the WIN-PAK API Client (3rd party system). In these scenarios the WIN-PAK system provides an excellent access control solution, where the API client is the overarching system that monitors and controls WIN-PAK’s access control hardware. In customer applications where multiple systems need to communicate with one another in real-time, WIN-PAK’s API provides the tools to create the solution for the access control part. When the integrated application has been completed, the Host platform is then able to lock and unlock doors and change reader modes in the WIN-PAK controlled hardware. Also adding and modifying cards and card holder information, time zones, holidays and access levels can be done from the host platform. For applications requiring a single point of data entry and control of employees and subsequent card holder status, such as a Human Resources application or even government systems, the API is the right tool for the job. F E AT U R E S •Developers can use VC++ to develop the application with the WIN-PAK PE API • WIN-PAK PE API includes -Database interface -Communication interface -Public programming documents -WIN-PAK API Test Client providing scenario examples to help developers • Compatible with WIN-PAK SE 4.0 and PE 4.0, build 673.3.2 onwards. •Seamlessly backwards compatible with WIN-PAK SE 3.0 and PE 3.0, build 670.16 onwards • Control and monitor access control hardware and devices from host platform • Manual override of system functions and schedules from host platform -Change Door modes: Lockout, Lockdown, PIN Only, Card+PIN, Card or PIN, Card Only -Open door once and timed • Database record entry, deletion and modification • Supported Operating Systems -Microsoft Windows 8 (64 Bit) -Microsoft Windows Server 2012 (64 Bit) -Microsoft Windows 7 (64 Bit) -Microsoft Windows Server 2008 R2 (64 Bit) WIN-PAK® PE API Application Programming Interface BENEFITS Save time by controlling and monitoring access functions from a host platform WIN-PAK access control in third party, multi brand platforms Access control has traditionally been brand specific business where software relates only to hardware of the same brand. Open platforms that support multi brand technologies and functionality are becoming more common in security systems and building management/ administration systems. The WIN-PAK PE API allows WIN-PAK to connect to those third party systems, making WIN-PAK an even more popular platform for integration. The API provides communication with the host platform, enabling operators to control doors and readers in the access system without switching between systems. This saves time and effort for the operator in responding to in security events. Sharing and connecting WIN-PAK database records for common use Compatibility with Human Resources and other administrative systems More and more organisations are requiring a single point of entry for their employees data and access security levels. Human Resources or Time and Attendance systems are commonly used as the single point of entering data and when integrated with the API, the HR system would automatically write the security elements for the access control system into the WIN-PAK access control system. Using WIN-PAK PE API, solutions not previously supported by WIN-PAK, such as biometric systems, can be supported. By connecting the biometric templates database to the WIN-PAK card holder records, WIN-PAK API is able to seamlessly deliver full system functionality. C O N F I G U R AT I O N A N D C O N N E C T I O N S HOST APPLICATION OR DATABASE APPLICATION (WIN-PAK API CLIENT) HOS DATA (WI WIN-PAK SERVER WITH WIN-PAK API SERVER WIN-PAK CLIENT IT-NETWORK DATABASE CONNECTION MONITORING AND CONTROL NETAXS-123 1,2,3 Doors PRO3200 1-32 Doors 2 WIN-PAK® PE API Application Programming Interface C A PA B I L I T I E S Honeywell's WIN-PAK® PE API provides the tools to connect WIN-PAK to other systems via database and communications, where WIN-PAK provides the access control security and the other system is the host and interface to the operator. Key Features Database API Features • Client / Server application • Database record entry, deletion and modification • Windows 8 Professional and Windows 2012 server compatible - Cards • Windows 7 Professional and Windows 2008 R2 server compatible - Activation and expiration date • Access control functionality through API - PIN code - Card status Communication API Features - Card holder • Monitor and control access control hardware and devices - Card holder notefields - NetAXS-123 and NetAXS-4 - Time zone data - PRO3200 and PRO2200 - Holiday schedules - N-1000 - Access level data - NS2+ - Define limited number of use (NetAXS) • Manual override of system functions and schedules from Host platform - Accounts - Change Door modes: Lockout, Lockdown, PIN Only, Card+PIN, Card or PIN, Card Only - Open door once and timed - Lock and unlock entry points - Energize and deenergize outputs Reporting Features • Get complete access tree including timezones • Search on card holders and note fields - Acknowledge and clear alarms - Add notes to alarms, logged into WIN-PAK database - Initialise panels - Get status of a panel T Y P I C A L A P P L I C AT I O N S Multi brand hosted applications • Security software platform • Safety software platform including Fire integration • Building management platforms • Multi facility software platform Industries Database sharing applications • Large office buildings • Human Resourse software platform • Transportation • Biometrics reader platform • Banking industry • Offline Locking systems • Light industrial • Elevator control systems • Warehouses • Schools/universities • Time and Attendance systems • Hospitals 3 WIN-PAK® PE API Application Programming Interface ORDERING WIN-PAK PE API Application Programming Interface WPP4API WIN-PAK PE Application Programming Interface for WIN-PAK Database and Communication Prerequisites Backwards compatible with the access control part of WIN-PAK SE 3.0 and WIN-PAK PE 3.0 (Build 670.16 and higher) Compatible with access control part of the below software part numbers: WPS4 WPS4G WPS4U5A WPS4U5GA WPP4 WIN-PAK WIN-PAK WIN-PAK WIN-PAK WIN-PAK SE SE SE SE PE 4.0 4.0 4.0 4.0 4.0 single user single user with Galaxy® integration five user five user with Galaxy integration unrestricted user with Galaxy integration (build (build (build (build (build 673.3.2 673.3.2 673.3.2 673.3.2 673.3.2 and and and and and higher) higher) higher) higher) higher) Note: Before purchasing WIN-PAK PE API a mandatory signed Non Disclosure Agreement between customer/integrator/developer and Honeywell is required. Microsoft®, Windows® Server 2012, Windows 8, Windows Server 2008, Windows 7 and SQL Server are registered trademarks of Microsoft Corporation WIN-PAK® and Galaxy® are registered trademarks of Honeywell International Inc. Find out more: www.honeywell.com/security/uk Fax: +44 (0) 1698 738300 Email: securitysales@honeywell.com Honeywell Security Group Aston Fields Road Whitehouse Industrial Estate Runcorn Cheshire WA7 3DL UK Tel: 08448 000 235 Fax: +44 (0)1928 754 050 www.honeywell.com HAS-WPAPI-02-UK(1014)DS-E October 2014 © 2014 Honeywell International Inc.