Models KR-, & KRC-

Transcription

Models KR-, & KRC-
Kilo Recessed & Kilo Recessed Corners- Installation Instructions
Models KR-, & KRC-
Please read all instructions prior to installation and keep for future reference!
1.
2.
3.
4.
5.
6.
Product to be installed by a qualified electrician.
Prior to installation ensure power is off at fuse box to prevent electrical shock.
Use only with Class 2 power supply.
Suitable for damp locations.
Access above ceiling required.
Type IC, inherently protected.
Option A
1
Page 1 of 2
Option B
junction box
(provided)
2
1.5" CUT
kilo recessed
cut-out
2.1
KILO RECESSED
DEPTH
extrusion
mounting
bracket
kilo recessed
corner cut-out
(if applicable)
2.7"
surface
kilo recessed
Option B: If the Kilo Recessed LED lead wires will be connected to
24VDC power wires inside provided junction box on top
of Kilo Recessed.
kilo
recessed
connector
2.1 Determine the location of the installation. Measure the fixture(s)
length (excluding the flanges on the ends of fixtures), and then cut a
1.5" wide cut-out all along the desired location.
4
kilo recessed
corner
(JB1 model shown below)
measure to determine
cut-out length
fixture
flange
Option A: If the Kilo Recessed LED lead wires will be connected to
24VDC power wires in a remote junction box.
3
6264 Oakton St
Morton Grove
IL 60053
T 224.333.6033
F 224.757.7557
info@luminii.com
www.luminii.com
Option A
kilo recessed
4.1
kilo recessed
corner
(if applicable)
3.1
3.1 If connecting fixtures together insert the connectors half way into
one fixture end. Followed by connecting fixtures together to secure.
5
Option B
5.1
kilo
recessed
junction
box
4.1 Run the fixture(s) lead wire to the remote power supply. Refer to step
9 for wiring.
6
kilo
recessed
screw
kilo recessed
corner
(if applicable)
5.1 Connect the 24VDC power wires to the Kilo Recessed LED wires
inside the nearest junction box Refer to step 7 for wiring. Once
wires are secure, secure the junction box to the back of Kilo
Recessed with the provided screws, make sure all wires &
connection are inside junction box.
mounting
bracket
6.1
6.1 Rotate mounting brackets on top of the Kilo Recessed so they are
flushed to the side of the Kilo Recessed.
6.2 Then carefully push the Kilo Recessed into mounting cavity. Hold the
Kilo Recessed in place then proceed to turn the mounting brackets
screws until fully tightened. Mounting brackets will rotate so they are
perpendicular to the extrusion to clamp down on mounting surface.
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
REV2.0
Kilo Recessed & Kilo Recessed Corners- Installation Instructions
Models KR-, & KRC-
6264 Oakton St
Morton Grove
IL 60053
T 224.333.6033
F 224.757.7557
info@luminii.com
www.luminii.com
Please read all instructions prior to installation and keep for future reference!
1.
2.
3.
4.
5.
6.
Product to be installed by a qualified electrician.
Prior to installation ensure power is off at fuse box to prevent electrical shock.
Use only with Class 2 power supply.
Suitable for damp locations.
Access above ceiling required.
Type IC, inherently protected.
7
Page 2 of 2
Multiple run option
add pigtails & run
to next fixture
-
power from remote
power supply
wires from remote
power supply
junction
box
+
conduit
(not included)
wires
from fixture
junction box
Kilo Recessed
Corners
Kilo
Recessed
surface
mounting
bracket
+24VDC (RED)
9
extrusion opening
class 11
power
supply
9.1
protective film
8.2
120 VAC
24 VDC to fixture(s)
9.1 Ensure power is off to power supply! Then proceed to connect
the Kilo Recessed lead wires to power supply. Connect
+24VDC red wire from Kilo Recessed to power supply +24VDC
red wire with appropriate wire nut. Connect -24VDC black wire
from Kilo Recessed to power supply -24 VDC black wire with
appropriate wire nut.
8.1 If necessary, plaster and finish the mounting surface to cover any
imperfections on the opening cutout.
8.2 Carefully snap diffuser lens into the extrusion then remove the
protective film from the front of the diffuser lens.
10
9.1
+24VDC (RD)
8.1
-24VDC (BLK)
8
-24VDC (BLK)
7.1 To connect multiple runs, connect fixture wires to the power supply wires in addition to adding pigtails. Run the pigtail wires to the next fixture to power.
Un-Install Fixture
(power must be turned off)
conduit
screw
drywall cut-out
extrusion
10.2
10.3
screw
driver
extrusion
junction
box
10.1
10.1
diffuser lens
10.3
diffuser lens
screw
driver
10.2
extrusion
10.1 Carefully insert & then rotate a small screw driver into the edge of the lens, and pull to remove the lens completely from the extrusion.
10.2 Loosen the screws from inside the extrusion, until the mounting bracket gets unhinged from the drywall. Pull the extrusion out of the drywall.
10.3 Remove the screws from the junction box, and disconnect the wire nut connections. To install refer to step 1.
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
REV2.0