Many industrial processes generate contaminant gases that can cause
­corrosion. Even minor damage to electronic components can have serious
consequences, e. g. fault signals, unplanned downtime, high repair costs.
The Viledon® HM® Cabinet Recirculation Unit is a complete system
used to control organic and inorganic gaseous contaminants by activated
carbon adsorption and chemical reaction. It provides highly purified air
for recirculating air within a control cabinet to prevent damage from contaminated air.
Each system is pre-engineered and includes a fan, a particulate pre-filter, a
­ edia
honeycomb matrix (HM®) activated carbon module with Versacomb™ m
and a particulate final filter. The compact footprint of the Viledon® HM®
Cabinet Recirculation Unit makes it ideal for mounting inside of sealed
­control cabinets.
4
How Viledon® HM® Cabinet
Recirculation Unit 15HM work
1
Intake of contaminated outside air
2
Pre-filtration
3
Fine filtration
Honeycomb matrix (HM®) activated
carbon module with Versacomb™ media
4
Purified air
free of fine particles and contaminant gases
Figure: Example of a
Viledon® HM® Cabinet
Recircukation Unit 15HM
3
2
1
2
1
2
How Viledon® HM® Cabinet
Recirculation Unit 3HM/10HM work
3
3
Figure: Example of a Viledon®
HM® Cabinet Recircukation Unit
3HM and 10HM
4
1
Intake of contaminated outside air
2
Media retention knob
3
Air outlet holes
4
Purified air
free of fine particles and contaminant gases
02 - GP - 291 - November - 2014 - US
Viledon® HM® Cabinet Recirculation Units
Energy-efficient, solutions for enhanced
corrosion control
Features and benefits
The Viledon HM Cabinet Recirculation Unit is
designed to control the harmful effects of low concentrations of corrosive gases in sealed electrical
cabinets. Through the use of Honeycomb Matrix
(HM®) activated carbon cubes with ­Versacomb™
media, the vapor adsorber will stop the damage
to process control equipment from corrosive gases
such as H2S, Cl2, ClO2 and SO2 to name a few.
The Viledon® HM® Cabinet Recirculation Unit
continuously scrubs the air inside of the control
cabinet, providing highly purified air, and thereby
eliminating corrosion of the equipment inside the
cabinet. Unlike other systems, our systems include
comprehensive follow-up service with regular inspection of both the equipment and the cabinet(s)
that the equipment protects.
®
®
Properties
Unit size dimensions
(W × L × H)
Air purification capacity
Media
Particulate filtration
ƒƒ Completely self-contained
ƒƒ Can be mounted horizontally or vertically
ƒƒ Aluminum construction for enhanced corrosion
protection
Applications
Pulp and paper, petro-chemical, steel, titanium,
wastewater treatment, specialty chemical, grain
processing and industrial processes.
3 HM
10 HM
15 HM
in
3.5 x 10.75 x 3.75
(5 lb)
3.5 x 10.75 x 3.75
(7 lb)
8 x 13 x 8
(15 lb)
CFM
3
10
14
in
6 HM™ module (1 pass)
6 HM™ module (1 pass)
4 HM™ module (1 pass)
MERV
8 (2 passes)
8 (2 passes)
8 (2 passes)
24 VDC
24 VDC
120V | 60 Hz | 1 Ph
3 | 0.2
4 | 0.5
7.5 | 0.13
Power supply
Power consumed
ƒƒ Provides corrosion protection for electronic cabinets that can not be located in protected rooms
W|A
The figures shown are mean values, subject to tolerances due to normal production variables. Our explicit written
confirmation is always required for the correctness and applicability of the information involved in any particular
case. Subject to technical alterations.
Freudenberg Filtration Technologies L.P.
Hopkinsville KY, 42240 / USA
Phone 1 800 348 7196 | Fax 1 270 887 5114
info-us@freudenberg-filter.com | www.freudenberg-filter.us
Replaces all previous issues of this data sheet. Viledon® is a registered and protected trademark of Carl Freudenberg KG.
Description