UNIVERSAL MASONRY HANGERS – UMH SERIES

Transcription

UNIVERSAL MASONRY HANGERS – UMH SERIES
Body CNDN Section 2_Body Section 2 2/13/2013 1:01 PM Page 109
UNIVERSAL MASONRY HANGERS – UMH SERIES
NEW
A versatile solution for hanging beams from masonry walls.
Face mount design allows hanger to be used with beam
heights from 16˝ to 24˝. Available in a variety of widths
for solid sawn, glulam, or engineered lumber beams.
© Copyright 2013 USP Structural Connectors®
Materials:
Finish:
Codes:
1/4˝ steel
USP primer
Load values derived from data submitted to various
North American building code evaluators.
Bond beam with
(1) #5 rebar continuous
5 1/4˝ Min.
edge distance
2 3/4˝ bolts.
(see footnote 2)
Installation:
• Use all specified fasteners. See Product Notes, page 10.
• Fully grouted and reinforced concrete block or cast-in-place
concrete with a minimum of (1) #5 rebar continuous to
footing with standard hook at bolt locations.
• Minimum joist bearing length is 31/2˝.
3 1/2˝ Min.
joist bearing
Typical UMH
installation
15 1/2˝
5˝
W
UMH
Fastener Schedule
Header2,3
USP
Stock No.
UMH358
UMH458
Joist4,5
Steel
W
Bolt
Gauge (in) Qty Dia. (in) Qty
Ref. No.
3
16
3/4
3-5/8 2
Type
16d
3
4-5/8
2
3/4
16
16d
UMH538
-- --
3
5-3/8
2
3/4
16
16d
UMH558
3
5-5/8
2
3/4
16
16d
UMH718
-- --
3
7-1/8
2
3/4
16
16d
Masonry (Lbs)
2500 psi
Masonry (kN)
2500 psi
Cast-in-Place
Concrete (Lbs)
3000 psi
Cast-in-Place
Concrete (Lbs)
3000 psi
1
1
1
1
Wood Vertical Uplift Vertical Uplift Vertical Uplift Vertical Uplift
Species 100%
115%
100%
115%
100%
115%
100%
115%
DF-L
11875
8205
52.82
36.50 11875
8205
52.82
36.50
S-P-F
8430
5825
37.50
25.91
8430
5825
37.50
25.91
DF-L
11875
8205
52.82
36.50 11875
8205
52.82
36.50
S-P-F
8430
5825
37.50
25.91
8430
5825
37.50
25.91
DF-L
11875
8205
52.82
36.50 11875
8205
52.82
36.50
S-P-F
8430
5825
37.50
25.91
8430
5825
37.50
25.91
DF-L
11875
8205
52.82
36.50 11875
8205
52.82
36.50
S-P-F
8430
5825
37.50
25.91
8430
5825
37.50
25.91
DF-L
11875
8205
52.82
36.50 11875
8205
52.82
36.50
S-P-F
8430
5825
37.50
25.91
8430
5825
37.50
25.91
Hangers
-- --
Factored Resistance
1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.
./")%)$"-/* *) -"/"./-0 /0-"1&/%/1*5!&*1"-../")"-."!$"*'/.4*-",0'1&/%5(&)&(0("("!(")/
*'/..%''"&)./''"!&)(.*)-31&/%$-*0/"! "''.&) *-!) "1&/%()0# /0-"-.&)./''/&*).+" &#& /&*).
*'/.(0./ *)#*-(/**-"//"-
&)&(0()&'"("!(")/.%''")&'!&("/"-./3+
5) NAILS:
!)&'.-"
5!&2
5'*)$
"1+-*!0 /.*-0+!/"!+-*!0 /&)#*-(/&*)-"!".&$)/"!&) red font.
1-800-328-5934 • www.USPconnectors.com
USP2240-131
109