Programmable Transmitter
Transcription
Programmable Transmitter
5131 Programmable Transmitter No. 5131V104-UK From ser. no.: 040112001 DK PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation. Programmet består af Isolatorer, Displays, Ex-barrierer, Temperaturtransmittere, Universaltransmittere mfl. Vi har modulerne, du kan stole på i selv barske miljøer med elektrisk støj, vibrationer og temperaturudsving, og alle produkter opfylder de strengeste internationale standarder. Vores motto »Signals the Best« er indbegrebet af denne filosofi – og din garanti for kvalitet. UK PR electronics A/S offers a wide range of analog and digital signal conditioning devices for industrial automation. The product range includes Isolators, Displays, Ex Interfaces, Temperature Transmitters, and Universal Devices. You can trust our products in the most extreme environments with electrical noise, vibrations and temperature fluctuations, and all products comply with the most exacting international standards. »Signals the Best« is the epitome of our philosophy – and your guarantee for quality. FR PR electronics A/S offre une large gamme de produits pour le traite ment des signaux analogiques et numériques dans tous les domaines industriels. La gamme de produits s’étend des transmetteurs de température aux afficheurs, des isolateurs aux interfaces SI, jusqu’aux modules universels. Vous pouvez compter sur nos produits même dans les conditions d’utilisation sévères, p.ex. bruit électrique, vibrations et fluctuations de température. Tous nos produits sont conformes aux normes internationales les plus strictes. Notre devise »SIGNALS the BEST« c’est notre ligne de conduite - et pour vous l’assurance de la meilleure qualité. DE PR electronics A/S verfügt über ein breites Produktprogramm an analogen und digitalen Signalverarbeitungsgeräte für die in dustrielle Automatisierung. Dieses Programm umfasst Displays, Temperaturtransmitter, Ex- und galvanische Signaltrenner, und Universalgeräte. Sie können unsere Geräte auch unter extremen Einsatzbedingungen wie elektrisches Rauschen, Erschütterungen und Temperaturschwingungen vertrauen, und alle Produkte von PR electronics werden in Übereinstimmung mit den strengsten internationalen Normen produziert. »Signals the Best« ist Ihre Garantie für Qualität! 1431 2-WIRE PROGRAMMABLE TRANSMITTER PRetrans type 5131 Contents Warning........................................................................................................ Symbol identification............................................................................. Safety instructions.................................................................................. How to demont system 5000............................................................ Application.................................................................................................. Technical characteristics....................................................................... Input types................................................................................................. Output.......................................................................................................... Sensor error detection........................................................................... Configuration............................................................................................. Electrical specifications........................................................................ Order............................................................................................................. 5131 connection to Loop Link........................................................... Selection of input type: (5131A)...................................................... Blockdiagram............................................................................................. 2 3 3 5 6 6 6 7 7 7 8 12 13 13 14 5 131V1 0 4 - U K 1 Warning GENERAL This device is designed for connection to hazardous electric voltages. Ignoring this warning can result in severe personal injury or mechanical damage. To avoid the risk of electric shock and fire, the safety instructions of this manual must be observed and the guidelines followed. The specifications must not be exceeded, and the device must only be applied as described in the following. Prior to the commissioning of the device, this manual must be examined carefully. Only qualified personnel (technicians) should install this device. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. WARNING HAZARDOUS VOLTAGE Until the device is fixed, do not connect hazardous voltages to the device. The following operations should only be carried out on a disconnected device and under ESD safe conditions: Dismantlement of the device for setting of dipswitches and jumpers. General mounting, connection and disconnection of wires. Troubleshooting the device. Repair of the device and replacement of circuit breakers must be done by PR electronics A/S only. WARNING INSTALLATION 2 SYSTEM 5000 must be mounted on DIN rail according to DIN 46277. The communication connector of SYSTEM 5000 is connected to the input terminals on which dangerous voltages can occur, and it must only be connected to the programming unit Loop Link by way of the enclosed cable. 5131V104- U K Symbol identification Triangle with an exclamation mark: Warning / demand. Potentially lethal situations. The CE mark proves the compliance of the device with the essential requirements of the directives. The double insulation symbol shows that the device is protected by double or reinforced insulation. Ex devices have been approved for use in connection with installations in explosive areas. Safety instructions Definitions Hazardous voltages have been defined as the ranges: 75 to 1500 Volt DC, and 50 to 1000 Volt AC. Technicians are qualified persons educated or trained to mount, operate, and also troubleshoot technically correct and in accordance with safety regulations. Operators, being familiar with the contents of this manual, adjust and operate the knobs or potentiometers during normal operation. Receipt and unpacking Unpack the device without damaging it. The packing should always follow the device until this has been permanently mounted. Check at the receipt of the device whether the type corresponds to the one ordered. Environment Avoid direct sunlight, dust, high temperatures, mechanical vibrations and shock, as well as rain and heavy moisture. If necessary, heating in excess of the stated limits for ambient temperatures should be avoided by way of ventilation. All devices fall under Installation Category II, Pollution Degree 1, and Insulation Class II. Mounting Only technicians who are familiar with the technical terms, warnings, and instructions in the manual and who are able to follow these should connect the device. 5 131V1 0 4 - U K 3 Should there be any doubt as to the correct handling of the device, please contact your local distributor or, alternatively, PR electronics A/S www.prelectronics.com Mounting and connection of the device should comply with national legislation for mounting of electric materials, i.e. wire cross section, protective fuse, and location. Descriptions of input / output and supply connections are shown in the block diagram and side label. The following apply to fixed hazardous voltages-connected devices: The max. size of the protective fuse is 10 A and, together with a power switch, it should be easily accessible and close to the device. The power switch should be marked with a label telling it will switch off the voltage to the device. Production year can be taken from the first 2 digits of the serial number. Calibration and Adjustment During calibration and adjustment, the measuring and connection of external voltages must be carried out according to the specifications of this manual. The technician must use tools and instruments that are safe to use. Normal operation Operators are only allowed to adjust and operate devices that are safely fixed in panels, etc., thus avoiding the danger of personal injury and damage. This means there is no electrical shock hazard, and the device is easily accessible. Cleaning When disconnected, the device may be cleaned with a cloth moistened with distilled water. Liability To the extent the instructions in this manual are not strictly observed, the customer cannot advance a demand against PR electronics A/S that would otherwise exist according to the concluded sales agreement. 4 5131V104- U K How to demont system 5000 First, remember to demount the connectors with hazardous voltages. By lifting the bottom lock, the device is detached from the DIN rail as shown in picture 1. Then, by lifting the upper lock and pulling the front plate simultaneously the PCB is removed as shown in picture 2. Switches and jumpers can now be adjusted. By opening the front, the programming connector is accessible as shown in picture 3. Picture 1: Separation from DIN rail. Picture 3: Access to programming connector. Picture 2: Removal of PCB. 5 131V1 0 4 - U K 5 2-WIRE PROGRAMMABLE TRANSMITTER 5131 • • • • • • Input for RTD, TC, mV, linear resistance, mA, and V 3.75 kVAC galvanic isolation 4...20 mA loop output 1- and 2-channel versions ATEX Ex version DIN rail mounting Application Electronic temperature measurement with resistance sensor or thermocouple sensor. • Ex barrier for temperature sensors, potentiometers and current / voltage signals. • Conversion of current signals from supplied transmitters to 2-wire 4...20 mA signals. • Amplification of mV signals. • Conversion of linear resistance variation. • Galvanic isolation of analogue signals. • Measurement of floating signals. • Linearisation of non-linear Ohm, mV, mA, or voltage signals. • Separation of circuits in PELV/SELV installations. Technical characteristics The unit is based on a microprocessor core with an efficient program operation. The basic calibration data and present set-up are stored in an EEPROM thereby avoiding the loss or change of data at power off. The 2-channel version has a full galvanic isolation between the channels. By way of a jumper on the PCB the input in the standard version can be programmed either for a temperature or a current / voltage input. This means that one channel can work as for instance a temperature transmitter and the other can work as an isolation amplifier. Measurement range, signal parameters, and output span are configured to the present task by way of a PC and PR electronics A/S’ communications interface Loop Link. Input types Temperature input - jumper in position 1: Thermocouple input (TC) for standard thermocouples type B, E, J, K, L, N, R, S, T, U, W3, W5, LR according to the norms IEC 584, DIN 43710, ASTM E988-90 and GOST 3044-84. 6 5131V104- U K The CJC can be selected in 3 different ways: internally in the terminal, externally by way of a Pt100 / Ni100 sensor, or externally with a constant temperature. If internal compensation is selected, a terminal with a built-in temperature sensor must be ordered separately (PR type no. 5910 and 5913). Sensor error detection is available. RTD input for Pt100...Pt1000 according to the norm IEC 751 and Ni100...Ni1000 according to the norm DIN 43760. Automatic cable compensation at a 3- or 4-wire connection. At a 2-wire connection the cable resistance can be entered or measured by the configuration program and sent to the device which then compensates by the entered cable resistance. Sensor error detection is available. Resistance input for resistance measurement with cable compensation as described under the RTD input. Sensor error detection is available. The mV input is programmable in the range -150...+150 mV. Current / voltage input - jumper in position 2: The current input is programmable in the range 0...100 mA, for instance 4...20 mA. The voltage input is programmable in the range 0...250 VDC. Output Standard loop 4...20 mA current output. The output signal is proportional and linear to the value of the input signal. Special set-ups can be selected in the configuration program, for instance a customised linearisation, a reversed output, a limiter according to the selected output span, and selection of an output value in case of a sensor error. Maximum load on the current output is 1375 Ω. Sensor error detection The output can be set up at a RTD, thermocouple and linear resistance input to go to max., to min., entered value, NAMUR NE43 Upscale or Downscale at sensor error detection. Configuration The transmitter is configured to the present task by way of a and PR electronics A/S’ communications interface Loop Link. The transmitter can be configured with or without a connected supply voltage as the communications interface supplies the necessary voltage to the set-up. The communications interface is galvanically isolated to protect the PC port. Communication is 2-way to allow the retrieval of the transmitter set-up into the PC and to allow the transmission of the PC set-up to the transmitter. For users who do not wish to do the set-up themselves, the 5131 can be delivered configured according to customer specifications: input type, measurement range, sensor error detection, and output signal. 5 131V1 0 4 - U K 7 Electrical specifications Specifications range: -20°C to +60°C Common specifications: Supply voltage........................................................... 7.5...35 VDC Fuse................................................................................ 50 mA SB / 250 VAC Consumption during programming.................... 3...8 mA Isolation voltage, test / operation..................... 3.75 kVAC / 250 VAC Communications interface.................................... Loop Link Signal / noise ratio................................................... Min. 60 dB (0...100 kHz) Signal dynamics, input............................................ 22 bit Signal dynamics, output........................................ 16 bit Updating time: Temperature input.............................................. 115 ms mA / V / mV input............................................... 75 ms Response time (0...90%, 100...10%), programmable: Temperature input.............................................. 400 ms...60 s mA / V / mV input............................................... 250 ms...60 s Calibration temperature......................................... 20...28°C Accuracy, the greater of the general and basic values: General values 8 Input type Absolute accuracy Temperature coefficient All ≤ ±0.05% of span ≤ ±0.01% of span / °C 5131V104- U K Basic values Input type Basic accuracy Temperature coefficient mA ≤ ±4 µA ≤ ±0.4 µA / °C Volt ≤ ±10 µV ≤ ±1 µV / °C RTD ≤ ±0.2°C ≤ ±0.01°C / °C Lin. resistance ≤ ±0.1 Ω ≤ ±10 mΩ / °C TC type: E, J, K, L, N, T, U ≤ ±1°C ≤ ±0.05°C / °C TC type: B, R, S, W3, W5, LR ≤ ±2°C ≤ ±0.2°C / °C EMC immunity influence................................................... < ±0.5% of span Extended EMC immunity: NAMUR NE 21, A criterion, burst.................................. < ±1% of span Effect of supply voltage change........................ Wire square (max.).................................................... Screw terminal torque............................................ Relative humidity..................................................... Dimensions (HxWxD)............................................... DIN rail type................................................................ Protection degree..................................................... Weight........................................................................... < 0.005% of span / VDC 1 x 2.5 mm2 stranded wire 0.5 Nm < 95% RH (non-cond.) 109 x 23.5 x 130 mm DIN 46277 IP20 195 g 5 131V1 0 4 - U K 9 Electrical specifications, temperature input: TC input: Type Min. temperature Max. temperature Min. span Standard B E J K L N R S T U W3 W5 LR +400°C -100°C -100°C -180°C -100°C -180°C -50°C -50°C -200°C -200°C 0°C 0°C -200°C +1820°C +1000°C +1200°C +1372°C +900°C +1300°C +1760°C +1760°C +400°C +600°C +2300°C +2300°C +800°C 200°C 50°C 50°C 50°C 50°C 100°C 200°C 200°C 50°C 75°C 200°C 200°C 50°C IEC584 IEC584 IEC584 IEC584 DIN 43710 IEC584 IEC584 IEC584 IEC584 DIN 43710 ASTM E988-90 ASTM E988-90 GOST 3044-84 Max. offset.................................................................. Sensor error current................................................. CJC................................................................................... Sensor error detection............................................ 50% of selec. max. value Nom. 30 µA ≤ ±1°C Yes mV input: Measurement range................................................. Min. measurement range....................................... Max. offset.................................................................. Input resistance........................................................ -150...+150 mV 5 mV 50% of selec. max. value Nom. 10 MΩ RTD and linear resistance input: Type Min. value Max. value Min. span Standard Pt100 Ni100 Lin. R -200°C -60°C 0Ω +850°C +250°C 5000 Ω 25°C 25°C 30 Ω IEC 751 DIN 43760 ------- Max. offset.................................................................. Max. cable resistance per wire............................ Sensor current............................................................ Effect of sensor cable resistance (3- / 4-wire)................................................................. Sensor error detection............................................ 10 50% of selec. max. value 10 Ω Nom. 0.2 mA < 0.002 Ω / Ω Yes 5131V104- U K Electrical specifications, mA / V / mV input: Current input: Measurement range................................................. Min. measurement range (span)......................... Max. offset.................................................................. Input resistance: Supplied unit.............................................................. Non-supplied unit..................................................... 0...100 mA 4 mA 50% of selec. max. value Nom. 10 Ω + PTC 10 Ω RSHUNT = ∞, VDROP < 6 V Voltage input: Measurement range................................................. Min. measurement range (span)......................... Max. offset.................................................................. Input resistance ≤ 2,5 VDC................................. > 2,5 VDC................................. 0...250 VDC 5 mVDC 50% of selec. max. value Nom. 10 MΩ Nom. 5 MΩ Electrical specifications - OUTPUT: Signal range (span).................................................. Min. signal range (span)......................................... Max. offset.................................................................. Load resistance......................................................... Load stability.............................................................. Current limit................................................................ 4...20 mA 10 mA 50% of selec. max. value ≤ (Vsupply-7.5) / 0.023 A) [Ω] ≤ 0.01% of span / 100 Ω ≤ 28 mA Sensor error detection: Programmable............................................................ NAMUR NE43 Upscale............................................ NAMUR NE43 Downscale...................................... No function................................................................. 3.5...23 mA 23 mA 3.5 mA Not defined EEx / I.S. approval (5131B): DEMKO 99ATEX124572........................................ II (1) GD [EEx ia] IIC Applicable for............................................................. Zone 0, 1, 2, 20, 21 or 22 5 131V1 0 4 - U K 11 Ex / I.S. data: Um................................................................................... Uo.................................................................................... Io...................................................................................... Po..................................................................................... Lo..................................................................................... Co..................................................................................... : 250 V : 8.0 VDC : 10 mADC : 20 mW : 200 mH : 1.0 μF GOST R approval: VNIIM & VNIIFTRI, Cert. no................................... See www.prelectronics.com Observed authority requirements: EMC 2004/108/EC................................................... LVD 2006/95/EC....................................................... PELV/SELV................................................................... ATEX 94/9/EC............................................................. Standard: EN 61326-1 EN 61010-1 IEC 364-4-41 and EN 60742 EN 50014, EN 50020 and EN 50281-1-1 Of span = Of the presently selected range Order Type 5131 Version Input Channels Standard :A RTD / TC / R / mA / V / mV ATEX Ex : B RTD / TC / mV / R : 1 mA / V / mV : 2 Channel 1, RTD / TC / mV / R : 3 Channel 2, mA / V / mV : - Single Double :A :B Note! For TC inputs with internal CJC, remember to order CJC connectors type 5910 / 5910Ex (ch. 1) and 5913 / 5913Ex (ch. 2). 12 5131V104- U K 5131 connection to Loop Link 13 11 Receiving Disconnect when "on line" loop communication is used equipment +Vsupp Loop communication Black Or Red Yellow Front communication can be used with or without 5131 connected to the receiving equipment CH 2 4...20 mA Input Green CH 1 5131 Language O ption O utput C om m unication File Product Input PRetop 5331 D ate: S erial no: Tag no: COM 08:30:00 1994-8-10 943201594 PRelectronics Analog input Loop Link Analog output 4 - 20mA U pscale O utput type: Pt100 D IN/IE C Input type: S ensor error: 0.00 - 50.00 C Input range: 3-wire C onnection: p: -----C old junction com 1.00 sec Response tim e: Selection of input type: (5131A) JP 1 JP 2 Temperature channel 1 Temperature channel 2 1 - 1 Current / voltage channel 1 Current / voltage channel 2 2 - 2 Input 5 131V1 0 4 - U K 13 RTD and lin. R Conn. wire 3 4 2 - + 5131V104- U K - mA V <= 2.5 Input gnd. + V - + !! If channel 1, use terminal no. 44...41 V> 2.5 V - + Input + Input +, > 2.5 V * TC Channel 2 shown as a current / voltage input: !! If channel 2, use terminal no. 54...51 - mV + mV CH 2 51 52 53 54 41 42 43 44 CH 1 Ex barrier, only 5131B 14 Ex barrier, only 5131B Channel 1 shown as a temperature input: 1 2 1 2 V+ JP 2 Analogue switch 0,2 m A PTC A /D EE PRO M C PU Front comm. V+ EEPRO M C PU 5131 Channel 2 A /D Front comm. 5131 Channel 1 PGA 50 k 10 Ω M UX Analogue switch PGA 50 k 10 Ω M UX 0,2 m A PTC 5M V+ JP 1 5M V+ D /A C om m . 4 mA D /A C om m . 4 mA * Accessories: 5910 CJC connector CH 1, 5913 CJC connector CH 2. 21 0...16 m A 4...20 m A A 4...20 m A Supply - A Supply + A Supply - 22 Test 23 11 0...16 m A A Supply + 12 Test 13 Blockdiagram Displays Programmable displays with a wide selection of inputs and outputs for display of temperature, volume and weight, etc. Feature linearization, scaling, and difference measurement functions for programming via PReset software. Interfaces for analog and digital signals as well Ex interfaces as HART® signals between sensors / I/P converters / frequency signals and control systems in Ex zone 0, 1 & 2 and for some devices in zone 20, 21 & 22. Galvanic isolators for analog and digital signals Isolation as well as HART® signals. A wide product range with both looppowered and universal isolators featuring linearization, inversion, and scaling of output signals. Temperature A wide selection of transmitters for DIN form B mounting and DIN rail devices with analog and digital bus communication ranging from application-specific to universal transmitters. Universal PC or front programmable devices with universal options for input, output and supply. This range offers a number of advanced features such as process calibration, linearization and auto-diagnosis. www.prelectronics.fr sales-fr@prelectronics.com www.prelectronics.de sales-de@prelectronics.com www.prelectronics.es sales-es@prelectronics.com www.prelectronics.it sales-it@prelectronics.com www.prelectronics.se sales-se@prelectronics.com www.prelectronics.co.uk sales-uk@prelectronics.com www.prelectronics.com sales-us@prelectronics.com www.prelectronics.cn sales-cn@prelectronics.com Head office Denmarkwww.prelectronics.com PR electronics A/S Lerbakken 10 DK-8410 Rønde sales-dk@prelectronics.com tel. +45 86 37 26 77 fax +45 86 37 30 85