Cummins 800-850kva - Sakr Power Systems
Transcription
Cummins 800-850kva - Sakr Power Systems
Tel: +20 2 635 5561 Mob.: +20 12 324 0990 Fax: +20 2 635 5569 info@sakregypt.com www.sakregypt.com Egypt – Cairo Apt. 4, Bldg. 17 Farid Symica Str., Heliopolis Cummins QSK 23 G3 Newage Stamford HCI 634 Generator Model: Generator Model: 3-Phase Cos Φ = 0.8 50 Hz RATINGS BCC 800P-50 BCC 850S-50 Power Factor PRIME POWER (PRP) STANDBY POWER (LTP) BCC 800P-50 BCC 850S-50 Voltage kVA kW e kVA kW e Amps 415/240 800 640 850 680 1183 400/230 800 640 850 680 1227 380/220 800 640 850 680 1291 Definition of Ratings & Reference Conditions Prime Power is continuously available for variable or constant load applications, with a maximum of 10% overload for one hour in every 12 hours of continuous operation. The average load must not exceed 70% of the nominal Prime Power rating. Standby Power is available for varying load applications only, and for a maximum of 500 hours per year. No overload is acceptable. The average load must not exceed 70% of the nominal Standby Power rating. The above power ratings are based on operating conditions of 25°C (77°F) air inlet temperature, 100kPa barometric pressure [110m (360ft) above sea level] and 60% relative humidity. Note: The above ratings may be subject to derate at different operating conditions. Please see the Derate guidelines on the Broadcrown website. All power ratings comply with the requirements of ISO 8526-1 and ISO 3046-1. Key Features: ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Efficient water cooled Diesel engine. Single bearing Newage Stamford alternator Radiator with pressure cap and drain point Fully guarded engine-driven fan Fully welded steel baseframe with lifting / jacking points Various fuel system options Heavy duty rubber anti-vibration mountings 24V starter batteries and connecting cables Separate engine-driven battery charging alternator Spin on oil and fuel filters and dry type air filter element Industrial silencer(s) supplied loose Auto Start control system with digital instrumentation Main line circuit breaker Factory Test Certificate Operation & Maintenance Manual Wide range of optional extra features available Overall Dimensions & Weights - Open Set Length (L) = 4210mm Width (W) = 1750mm Height (H) = 2230mm H L Dry Weight (inc oil) = 6085kg Operating Weight = 6195kg W Typical Open Generator Sound Pressure Level at 1m, Free Field (dB) Overall dBA 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 106 95 100 101 101 101 99 95 94 All specifications and design are subject to change without notice BCC 800P-50 BCC 850S-50 CUMMINS QSK 23 G3 ENGINE & COOLING SYSTEM STANDBY 768 15 753 m 3200 3200 General Cylinders / Type Aspiration / Charge Cooling Governing / Engine Management Bore / Stroke Cubic Capacity BMEP mm litres kPa 6 cyl / Inline / 4-stroke Turbocharged / Air to Air Electronic Governor / ECU 170 / 170 23.15 2422 2654 Fuel Fuel Consumption at 100% Power Fuel Consumption at 75% Power Fuel Consumption at 50% Power Total fuel flow Standard Fuel Tank Capacity litres/h litres/h litres/h litres/h litres Air Engine Air Flow Maximum Air Intake Restriction (used filter) m³/s kPa 0.815 Exhaust Exhaust Gas Flow Exhaust Gas Temperature Maximum Exhaust Back Pressure Typical Exhaust Pipe Diameter m³/s °C kPa mm 2.259 532 Cooling Radiator Cooling Air Flow Max Restriction to Cooling Air Flow Max Radiator Air-On Temperature Maximum Coolant Temperature Coolant Capacity - Engine Only Total Coolant Capacity m³/s Pa °C °C litres litres 9.7 250 45 104 46.5 96.5 Total Oil Capacity incl Filters Typical Oil Pressure at Rated Speed Typical Oil Consumption (>250hrs Operation) litres kPa litres/h 103 345 0.42 Heat Rejection to Engine Cooling Water Heat Rejection to Charge Cooler Heat Radiated From Engine (Typical) kW kW kW Electrical System Voltage Battery Type Battery Capacity SAE CCA V Performance 701 15 686 Oil 1500 r/min kWm kWm kWm Thermal Engine Speed Gross Power Fan Power Net Power Emissions Certification Altitude Capability PRIME Elec SI Units 0.888 6.23 2.463 543 10.2 250 215 122 65 222 146 71 24 2 (Series) 623 865 NEWAGE STAMFORD HCI 634 SI Units General Data 178 134 94 684 720 A ALTERNATOR Manufacturer Model (may vary with voltage) Operating Temperature Coupling / No. of Bearings Phase / Poles / Winding Type Power Factor Excitation Insulation System AVR Type Voltage Regulation 161 121 85 °C All specifications and design are subject to change without notice PRIME STANDBY NEWAGE STAMFORD HCI 634 G HCI 634 G 40 27 Direct / Single Bearing 3-Phase / 4-Pole / Winding 311 Cos Φ = 0.8 Separately excited by PMG Class H MX321 ± 0.5% BCC 800P-50 BCC 850S-50 STANDARD CONTROL SYSTEM - EXPORT PRODUCTS BC 5110 Digital Auto Start The standard control system for Export products is BC 5110 (photo), based on the Deep Sea Electronics DSE5110 Digital Auto Start controller. This provides for the manual and automatic remote start of the generator with a LCD digital display of : ▪ ▪ ▪ ▪ ▪ Coolant Temperature, with integral high temperature protection Oil Pressure, with integral low pressure protection Volts, Amps and Frequency Engine operating hours Battery volts Also featuring : ▪ ▪ ▪ ▪ Automatic cool-down timer function Emergency Stop button Ample auxillary inputs/outputs for optional features Optional - battery charger and door mounted illuminated switch. CONTROL SYSTEM OPTIONS - EXPORT PRODUCTS BC 5310 & BC 5320 control systems (just the DSE modules shown here) provide complete power monitoring and protection facilities. Compared to BC 5110, addition features include : ▪ ▪ ▪ ▪ ▪ Pre-alarms for Low Oil Pressure and High Coolant Temperature Digital display of kW, kVA and Power Factor Under/Over Volts protection Over Current Protection Full RS485 Telemetry implementation The BC 5320 provides full AMF functionality with integrated mains monitoring and generator/mains contactor control. The BC 5510 & BC 5520 control systems provide the same features as BC 5310 & BC 5320 respectively, plus : ▪ BC 5510 - Set-to-Set Synchronisation ▪ BC 5520 - Single Set-to-Mains Supply Synchronisation with integrated mains monitoring For Multi Set-to-Mains synchronisation, each set requires BC 5510 with the addition of one mains monitoring panel BC 5560 (not illustrated). See the Synchronisation Guidelines for further details. CONTROL SYSTEM OPTIONS - X-RANGE The X-Range of control systems has been developed to suit larger generating sets (>500kVA) for the UK and Projects market. The entry level is Remote Start and provides for the manual and automatic remote start of the generator with LCD digital display all operating paramaters including : ▪ ▪ ▪ ▪ ▪ ▪ Coolant temperature with high temperature alarm and shutdown Oil pressure with low pressure alarm and shutdown Engine operating hours, battery charge volts and amps Volts, with Under/Over Volts protection Amps, with Over Current protection Frequency, kW, kVA, Power Factor The Automatic Main Fail variant add full AMF functionality with integrated mains monitoring and generator/mains breaker control. The Generator Parallel system makes provision for set-to-set synchronisation, whilst the Mains Parallel version allows single set-to-mains synchronisation with integrated AMF functionality. By means of the Multi-Set Mains Parallel system (not illustrated) a number of sets can be synchronised with each other and the mains supply. All specifications and design are subject to change without notice