BG2 Range - MANUAL CALL POINT
Transcription
BG2 Range - MANUAL CALL POINT
BG2 Range - MANUAL CALL POINT Ex de, Intrinsically Safe (Ex ia), Weatherproof Features 4 Zone 0, Zone 1 and Zone 2 use. 4 Ex de, Ex ia or weatherproof. 4 ATEX approved– Ex II 1GD (Ex ia). – Ex II 2G (Ex de). 4 BASEEFA certified. 4 IP66 and IP67. 4 Certified temperature: –40ºC to +70ºC*. 4 Corrosion resistant red painted GRP. 4 Retained stainless steel cover screws. 4 Optional lift flap. 4 Key operated test facility. 4 Lightweight and robust. 4 Breakglass hammer available. (Contact sales office for details). *Depending on version. Introduction This manual fire alarm call point has been designed for use in flammable atmospheres and harsh environmental conditions. The GRP enclosure is suitable for use offshore or onshore where lightweight combined with a high level of corrosion resistance is required. Head Office. Unit B, Sutton Parkway, Oddicroft Lane, Sutton in Ashfield NG17 5FB, UK. Head Office (USA) 3413 North Sam Houston Parkway West, Suite 212, Houston, TX 77086, USA Sales Enq. UK: +44 (0)1623 444 445 Sales Enq. USA: +1 (713) 937- 9772 E-Mail: MEDCSales@Eaton.com Web: www.medc.com 22 Certification and Specification ATEX Ex de: ATEX Ex ia: Cert. no. BAS02ATEX2105X. ATEX Approved Ex II 2G. Certified to: EN60079-0, EN60079-1, EN60079-7. Ex de IIC T6 Gb switch only. Ex de mb IIC T4 Gb with resistors & diodes. Cert no. Baseefa 03ATEX0084X. ATEX Approved Ex II 1GD. Certified to: EN60079-0, EN60079-11. Ex ia IIC T4 Ga, Ex ia IIIC T135ºC Da. Material: Anti static UV resistant Glass Reinforced Polyester. Finish: Painted Red. Certified Temp: -40ºC to +70ºC. Voltage: Up to 254V a.c. (Ex ia - Up to 28V d.c.). Weight: 1.2Kg. Ingress Protection: IP66 & IP67. Cable Entries: 2 x M20 bottom. Terminals: 6 x 2.5mm². Resistor Values: Ex de - 100Ω minimum, 39KΩ maximum. Ex ia - 470Ω minimum. Switch ratings: d.c. 0-30V 5A (resistive) or 3A (inductive). 30V-50V 1A resistive or inductive. a.c. 0-254V 5A resistive or inductive. 1. Switch Only 2. End of Line Resistor / Diode R1/D1 1 2 3 4 5 6 1 2 3 4 5 6 ALL CIRCUITS SHOWN WITH GLASS INTACT ALL DIMENSIONS IN MILLIMETERS 3. In Line Resistor / Diode R2/D2 4. In Line & End of Line Resistor / Diode R1/D1 R2/D2 1 2 3 4 5 6 1 2 3 4 5 6 Ordering Requirements The MEDC BG Range of Manual Alarm Call Points caters for numerous options such as variety of colours, LED indication, earth continuity, double switch, etc. See separate catalogue sheet for details. The following code is designed to help in selection of the correct unit. Build up the reference number by inserting the code for each component into the appropriate box. Model Options Flap Finish ModelCode BG2W – a.c. or d.c. BG2WNN BG2I – Up to 28V (I.S.) BG2INN BG2E – d.c. BG2EDC BG2E – a.c. BG2EAC OptionsCode Switch only 1 End of line resistor 2* In line resistor 3* In line and end of line resistor 4* Diode (specify location & value)5 FlapCode Fitted F* Not Fitted N FinishCode Red Painted R *Polycarbonate lift flap. *Specify resistor values. All specifications, dimensions, weights and tolerances are nominal (typical) and MEDC reserve the right to vary all data without prior notice. No liability is accepted for any consequence of use. 6DS029/Q 06/14 23