Showerlux Legacy Pivot Door Installation Instructions
Transcription
Showerlux Legacy Pivot Door Installation Instructions
Showerlux Legacy Pivot Door Installation Instructions IMPORTANT - PLEASE READ ● Please read these instructions carefully before assembly and installation. ● Please inspect immediately upon receipt for damage that may have been caused in transit. Please examine all exposed glass edges and corners prior to assembly, damaged edges can cause spontaneous breakage during product life time. ● Damage reported later cannot be accepted. ● Please assess the weight of this product prior to assembly and installation. Seek assistance should you require it. ● Before installation, you must ensure that the shower tray is level in all directions and completely sealed to the tiles. ● This product must only be fitted onto tiled or waterproof surfaces. ● The wall plugs and screws supplied are for use on solid walls and floors only. Any other surface will require alternative fixings. ● The enclosure when fitted, must not overhang the front of the tray. ● Please leave this instruction leaflet with the customer. HINTS & TIPS ● Surfaces to be siliconed should be de-greased in accordance with silicone suppliers instructions, observing any safety instructions. ● Ensure there are no hidden pipes or cables in the wall before drilling. ● If using power tools (e.g. to drill holes) wear safety glasses and always disconnect tools from the power supply after use. ● If drilling holes in ceramic tiles use a piece of masking tape on the tile to stop the drill bit from slipping. ● DO NOT use your drill on hammer action when drilling holes in ceramic tiles. ● Use the opened out enclosure packaging to protect your floor and wall while assembling. ● To check spirit level accuracy place on a horizontal surface. Note the bubble position between markers. Rotate the spirit level through 180 Degrees horizontally then note the bubble position. Check both noted positions match each other. If they do not match recalibrate or renew the spirit level. Repeat the test also in the vertical plane. CARE & MAINTENANCE ● To prevent the formation of water spots on the glass, use the squeegee supplied in the installation fixing pack to wipe down the glass after every shower. ● Always use plenty of water and a soft cloth or sponge to wipe down all aluminium sections and plastic parts. ● Aggressive proprietary cleaning agents may seriously damage your product. Do not use any solvent or abrasive chemicals to clean this product. ● We recommend that this product is cleaned with Showerlux 'Showerclean' once a week. This will help to reduce the build up of lime scale. ● Showerlux enclosures and screens are generally maintenance free. However, it may be necessary to lubricate roller assemblies or other moving hinge parts occasionally. Use a high quality silicone spray on the moving parts as required. (1) Please Read Carefully Showerlux 'LEGACY' shower enclosures can be installed without the need to step inside the Shower tray area. Please follow the instructions carefully TOOLS REQUIRED 3.2 6 LIST OF SPARE PARTS A X2 B X2 C X1 D X2 ST4*30 Long (R)(L) E X2 F X8 G X8 H X8 ST4*12 short I X8 J X1 K X1 (2) L X1 M X1 ST E P 1 Please ensure the shower tray is level in all directions as shown above S TE P 3 ST E P 2 1.Push fit the top covers (D) as shown above. 2.push fit the vertical compensators (A) please ensure the visible punch holes are on the outside of the enclosure to allow external fixing. STEP 4 G 6 Position the enclosure 11mm in from the ledge of the tray to the face shown above ensure the vertical wall compensator is positioned to the outside of the tray with the holes visible for external fixing. Ensure the frame is level and mark the points for drilling. Remove the enclosure from tray, position safely to one side and drill the marked positions and fit plugs as shown (G). (3) STEP 5 H Reposition the frame and attach the wall compensator with the screws (H). STEP 6 K C J Fit the handle (C ) first, then push fit the vertical magnet (K) to the handle side of the door & the vertical flipper seal (J) to the rear side as shown above. (4) STEP 7 Secure the frame to the wall comp with parts (F) & (I) ensuring that the glass is parallel to the frame as shown above then apply cover (B) as shown in the diagrams above. STEP 8 STEP 9 Push-fit the lower seal to glass, as shown above. Push fit the top covers (E) as shown above. Ensure the seal is cut flush at the hinge end (1) and fit tightly against the hinge. Cut & shape the seal around vertical magnet (2) and silicone into position (3). Failure to do so, can significantly affect the product's performance. (5) STEP 10 From the outside apply sealant down the full length of the vertical wall compensators and across the base of the lower rail as illustrated. Ensure to seal 50mm up the external rail joints as shown in the diagram below. SHOWERLUX HELPLINE:02476 882518 SHOWERLUX(UK) Ltd. Fax:02476 882539 Sibree Road,Coventry,West Midlands CV3 4FD Email:technical@showerlux.co.uk Tel:02476 639400 Email:spares@showerlux.co.uk Fax:02476 305457 Due to a policy of continuous improvenment and product development, Showerlux UK Limited reserves the right to amend specification without notice (6) PRODUCT SCHEMATIC DIAGRAM E F K D J G C A S-61 8 I M (7) L H B