Electronic Lamp Control - ETA PLUS ELECTRONIC GmbH
Transcription
Electronic Lamp Control - ETA PLUS ELECTRONIC GmbH
® ELC Electronic Lamp Control eta plus electronic gmbh part of the IST METZ group, Lauterstrasse 29, D-72622 Nuertingen, Germany tel: +49 (0)7022 60 02 813; @: info@eta-uv.de fax: +49 (0)7022 60 02 888 www.eta-uv.de Stand: Sept.13 ELC® general information The electronic lamp control units ELC® are designed to power UV medium pressure discharge lamps. In four different series we offer fully integrated electronic lamp control solutions for UV lamps from 3 kW to 35 kW. Various air and water based options offer most flexible and power system integration. versions are designed for applications such as BWMS, water treatment on ships. cooling reliable Special marine ballast The ELC® control strategies allow easy PLC connection via PROFIBUS, Modbus or analog signals, and supports smart lamp control, safety and servicing options. Technology: All ELC® are based on a high frequency resonant power converter to precisely power the medium pressure lamps. This topology combines highest efficiency at lowest electromagnetic interference. The fully insulated lamp output allows perfect lamp matching as well as short circuit and earth fault resistant operation. 2/19/2015 Our MP lamps: Our customer-specific in-house lamp development and manufacturing permits the optimum component match for your UV system. Coupled with the consistent quality strategy, we supply the industries most reliable and efficient UV components available on the UVmarket. system reliability - smart soft ignition - highest lamp lifetime efficiency - low heat exhaust - highest ambient temperature - energy savings step less lamp control - dimming range 20% - 100% - precisely controlled and monitored lamp status mains compliance - high power factor - low harmonic distortion - symmetric load - no inrush current - no start-up over-current safety features - insulated lamp output - integrated earth fault detection - short circuit proof ELC® is a registered trademark of IST Metz GmbH 2 ELC® series ELC® X series • lamp power: 6 kW, 8 kW, 4kW, 12kW* • Modbus and PROFIBUS control • wide input voltage range 360 V to 528 V • lowest harmonic distortion THDi • protection IP 66 • integrated heat exchange • X_B series option for marine applications ELC® P series • nominal lamp power: 5 kW to 35 kW • PROFIBUS control • highest efficiency • protection IP 20 • air cooled ELC® N series • nominal lamp power: 4 kW to 32 kW • analog / digital PLC control port • highest efficiency • protection IP 20 • air cooled ELC® IP series • nominal lamp power: 5 kW to 10 kW 2/19/2015 • field bus (PROFIBUS) control • protection IP 65 • water cooled * 12kW under development 3 ELC® X series The result of intense in-house R&D and market experience; The X series combines ideal mains compatibility with a highly innovative cooling principle for best reliability and maximum installation flexibility. The field bus allows smart control and infield diagnostics. Type Lamp power Lamp voltage Dimensions see ELC X4-40 4 kW 400 V Appendix A ELC X6-60 6 kW 600 V Appendix A ELC X8-80 8 kW 800 V Appendix A ELC X12-110* 12 kW 1100 V Appendix A 2/19/2015 * under development mains voltage wide input range 360V - 528V, 2 phase power factor typ. 0.98 efficiency typ. 94% harmonic current distortion THDi < 10% control port PROFIBUS and Modbus safety interrupt built-in safety relay for emergency stop lamp dimming range 16% to 100%* lamp monitoring voltage, current, power, status earth fault detection standard max. distance to lamp 40m (standard), (100m with special lamp cable)* protection IP66 max. ambient temperature 45 °C (X_B series 55°C) cooling forced air cooling, no air filter required dimensions 470mm x 125 mm (w x h) depth: X4: 260mm, X6: 320mm, X8: 420mm, X12: 420mm weight X6: 14 kg, X8: 19 kg * approvals CE, EN 50 178, (UL and IMO under development)* special feature stacking option allows cabinet-free installation of up to 12 modules in one tower * preliminary data, subject to technical alterations, data may vary over types 4 ELC® X_B series For marine applications like BWMS; This version of ELC X series is designed in compliance with IMO MEPC174(58) regulation. Type Lamp power Lamp voltage Dimensions see ELC X4B-40* 4 kW 400 V Appendix A ELC X6B-60 6 kW 600 V Appendix A ELC X8B-80 8 kW 800 V Appendix A ELC X12B-110* 12 kW 1100 V Appendix A * under development max. temperature 55°C vibration proof humidity proof (IP66 rated design) built-in heat exchange included harmonic filter optimized for generator supply wide supply input 360 to 528 V, fully covers 440V ±20% 2/19/2015 advanced lamp ignition for low temperatures lamp distance up to 100m highest power density designed according to MEPC174(58) 5 subject to technical alterations, data may vary over types ELC® P series Based on the N series, the P series offers a smart digital field bus control combined with highest power density in a compact and efficient design. The field bus control enables in-field diagnostics, and significantly reduces wiring. Type 400 V version Type 480 V version Lamp power Lamp voltage Dimensions see ELC P5HV-400-40 ELC P5HV-480-40 5 kW 400V Appendix D ELC P10-400-80 ELC P10-480-80* 10 kW 800V Appendix D ELC PE12-400-110 on request 12 kW 1100V Appendix B ELC PE16-400-140 on request 16 kW 1400V Appendix B ELC PE22-400-220 on request 22 kW 2200V Appendix C ELC PE32-400-280 on request 32 kW 2800V Appendix C 2/19/2015 * under development mains voltage 400 V or 480 V, ± 10%, 3 phase, 50/60 Hz power factor P type: typ. 0.93, PE type: typ. 0.90 efficiency P type: typ. 96%, PE type: typ. 94% harmonic current distortion THDi P type: 33%, PE type: typ. 36% * control port PROFIBUS safety interrupt yes lamp dimming range 20% to 100% lamp monitoring voltage, current, power earth fault detection standard max. distance ELC® to lamp 15 to 40m (depending on ELC type) protection IP20 max. ambient temperature 40 °C to 50 °C (depending on ELC type) cooling forced air cooling dimensions see table above weight typ. 15 kg to 37 kg approvals CE, EN 50 178 * PE type requires additional mains choke UK = 4% subject to technical alterations 6 ELC® N series A modular ELC® concept offering the highest efficiency and process stability for all applications. The analog control port offers easy connection to any PLC. Type 400 V version Type 480 V version Lamp power Lamp voltage Dimensions see ELC N3HV-400-30 ELC N3HV-480-30 3 kW 300V Appendix D ELC N4HV-400-40 ELC N2x4-480-40 4 kW 400V Appendix D ELC N2x4-400-40 ELC N2x4-480-40 two times 4 kW 400V Appendix D ELC N5HV-400-40 ELC N5HV-480-40 5 kW 400V Appendix D ELC N6-400-75 ELC N6-480-75 6 kW 750V Appendix D ELC N8-400-80 ELC N8-480-80 8 kW 800V Appendix D ELC N10-400-80 ELC N10-480-80 10 kW 800V Appendix D ELC NE12-400-110 on request 12 kW 1100V Appendix B ELC NE16-400-140 on request 16 kW 1400V Appendix B ELC NE22-400-220 on request 22 kW 2200V Appendix C ELC NE32-400-280 on request 32 kW 2800V Appendix C mains voltage 400 V or 480 V, ± 10%, 3 phase, 50/60 Hz power factor N type: typ. 0.93, NE type: typ. 0.88 efficiency N type: typ. 96%, NE type: typ. 94% (depending on ELC type) harmonic current distortion THDi N type: 33%, NE type: typ. 45% * control port analog 0-10V, digital I/O, PLC compatible safety interrupt no lamp dimming range 20% to 100% lamp monitoring current, power earth fault detection standard 2/19/2015 max. distance ELC® to lamp 15 to 40m (depending on ELC type) protection IP20 max. ambient temperature 40 °C to 50 °c (depending on ELC type) cooling forced air cooling dimensions see table above weight typ. 15 kg to 37 kg approvals CE, EN 50 178, (UL depending on ELC type) subject to technical alterations * NE type requires additional mains choke UK = 4% 7 ELC® IP series Perfectly protected water-cooled ELC® for harsh operating conditions. This series is controlled via PROFIBUS, allowing smart control and in-field diagnostics. Type 400 V version Type 480 V version Lamp power Lamp voltage ELC P5IP-400-40* ELC P5IP-480-40* 5 kW 400V ELC P10IP-400-80 ELC P10IP-480-80* 10 kW 800V * on request mains voltage 400 V or 480 V, 3 phase , ± 10%, 50/60 Hz power factor typ. 0.93 efficiency typ. 96% harmonic current distortion THDi 33% control port PROFIBUS safety interrupt standard lamp dimming range 20% to 100% lamp monitoring voltage, current, power earth fault detection standard 2/19/2015 max. distance ELC® to lamp 15 to 20m (depending on ELC type) protection IP65 max. water temperature 35 °C cooling water 3L / min dimensions approx. 540 x 130 x 235 mm (h x w x d) weight approx. 15 kg approvals CE, EN 50 178 subject to technical alterations 8 Appendix A: ELC® X series ELC® X4 ELC® X6 2/19/2015 ELC® X8, X12 9 Appendix B: ELC® NE12, NE16, PE12 , PE16 261 mm 263,5 mm Steckerleiste für Steuersignale control connector min. 150 Lufteintritt air entrance 31 mm 650 mm Luftaustritt air exhaust 2/19/2015 Netzanschluß line input 200 mm min. 150 31 mm 501 mm 540 mm Oben top Lampenstecker lampconnection 10 Appendix C: ELC® NE22, NE32, PE22, PE32 261 mm Steckerleiste für Steuersignale control connector 484 mm Lufteintritt air entrance min. 150 Lufteintritt air entrance 200 mm 31 mm 650 mm min. 150 31 mm 501 mm 540 mm Oben top 2/19/2015 Luftaustritt air exhaust Netzanschluß line input Luftaustritt air exhaust Lampenstecker lampconnection 11 min. 20 Appendix D: ELC® N3 to N10, P5 to P10 min. 100 min. 50 pin-and-socket connector for control signals min. 100 473 mm 539 mm 520 mm top M8 (4x) 130 mm 23 mm 80 mm Lamp feeder connection mains connection 321 mm Back mounting (see manual for further info) (see manual for further info) 2/19/2015 Side-by-side rack mounting 12