Create TruSight Sample Plates and Sample
Transcription
Create TruSight Sample Plates and Sample
Create TruSight Sample Plates and Sample Sheets with IEM FOR RESEARCH USE ONLY This quick reference card describes how to use the Illumina® Experiment Manager (IEM) to create a TruSight™ Enrichment, TruSight One, TruSight Cardio, or TruSight Rapid Capture sample plate, and create and edit sample sheets compatible with your Illumina sequencing system and analysis software. This quick reference card describes how to use the Illumina® Experiment Manager (IEM) to create a TruSeq® Custom Amplicon, TruSeq Amplicon - Cancer Panel, or TruSight™ DNA Amplicon sample plate, and create and edit sample sheets compatible with your Illumina sequencing system and analysis software. For more detailed general information on how to use the IEM application and definitions of the sample sheet applications, see the Illumina Experiment Manager User Guide (part # 15031335). New or less experienced users are advised to read the guide before using this quick reference card. NOTE • For TruSight HLA sample plates and sample sheets, see Create TruSight HLA Sample Plates and Sample Sheets with IEM (part # 15069713). • For TruSight DNA Amplicon sample plates and sample sheets, see Create TruSeq or TruSight Amplicon Sample Plates and Sample Sheets with IEM (part # 15037154). NOTE Regarding biomarker patents and other patents unique to specific uses of products. Some genomic variants, including some nucleic acid sequences, and their use in specific applications may be protected by patents. Determine if you are required to obtain licenses from the party that owns or controls such patents in order to use the product in your specific application. support page, select the Downloads tab and select the manifest file. Copy the manifest file to the following locations: } IEM Manifest Repository—Select Folder Settings on the IEM main screen to verify location. When it is saved to this location, the manifest is visible in the Nextera Manifest section of the Sample Selection page. } MiSeq Manifest Repository—Select the Manage Files icon on the MiSeq Welcome screen and upload the Manifest file under the Manifest tab. NOTE Set the default Manifest folder location on the MiSeq Run Options screen by selecting Folder Settings. Create a Sample Plate NOTE A sample plate is not required to generate a sample sheet, but can be useful for organizing samples. 1 Open the IEM software. 2 On the IEM main screen, select Create Sample Plate. 3 On the Sample Prep Kit Selection screen, select TruSight Enrichment, and then select Next. 4 On the Assay Parameters screen, do the following: a In the Unique Plate Name field, type a name for the sample plate. b In the Index Reads field, select the number of indexes to run for the samples on this plate: 0, 1, or 2. c Click Next. 5 On the Plate Samples screen, select the Table or Plate tab. You can enter information for the wells in your plate using either view. 6 For each well that contains a sample, do the following: a Enter a unique sample ID. b Specify what index adapter you intend to use for each Index Read. c Select the appropriate Manifest from the drop-down menu. d If you want to capture more detailed information about the plate, enter a sample name, project, and description. 7 [Optional] Click the Plate Graphic tab to view the sample Workflows For TruSight One, TruSight Cardio, and TruSight Rapid Capture, the Enrichment workflow is the recommended analysis workflow. Manifests An Illumina provided manifest file is required for the Enrichment workflow and by the analysis software to define regions of interest (e.g., genomic coordinates of targeted regions) and to complete the sample sheet. To download a manifest file, go to support.illumina.com. Select Sequencing, then Kits & Reagents. Select the sample prep kit that you are using to open its support page. On the Part # 15048138 Rev. C 1 of 4 Create TruSight Sample Plates and Sample Sheets with IEM ID and index adapter in each well. a If you want to copy an image of your sample plate for use in a presentation or paper, select Copy to Clipboard on the Plate Graphics tab. You can paste the image into any graphics-enabled program, such as Paint, Microsoft PowerPoint, Microsoft Word, and Adobe Photoshop. b If you want to print an image of your sample plate, select Print... on the Plate Graphics tab. 8 g h i 5 On the Sample Selection screen, select Select Plate and navigate to a sample plate you created previously. If you have not yet created a sample plate, you can do so now by selecting New Plate. 6 Click Select All to include all wells in this sequencing run or highlight the wells you want to include in this sequencing run. 7 Click Add Selected Samples. 8 [Optional] Click Add Blank Row to add rows and manually enter the sample information. 9 Make sure that the required sample ID, index adapters, and Nextera Manifest are displayed. Type a sample name, sample project, and description for each sample, as desired Click Finish and save the sample plate file. WARNING The sample plate file must contain the following file extensions: *.nexenr0.plt for plates with no indexes *.nexenr18.plt for plates with a single index *.nexenr28.plt for plates with dual indexes Create a Sample Sheet This section provides instructions for creating a sample sheet for the analysis of MiSeq®, HiSeq®, HiScanSQ™, Genome Analyzer™, or NextSeq™ sequencing data. Create a MiSeq-Compatible Sample Sheet 1 On the IEM main screen, select Create Sample Sheet. 2 On the Instrument Selection screen, select MiSeq, and then select Next. 3 On the MiSeq Application Selection screen, select the desired category and application for your kit, and then select Next. For TruSight Enrichment, TruSight One, TruSight Cardio, and TruSight Rapid Capture products, the following categories and applications are supported: 4 Category Application Targeted Resequencing Enrichment Other FASTQ Only On the Workflow Parameters screen, do the following: a In the Reagent Cartridge Barcode field, enter the barcode number of the MiSeq reagent cartridge. b From the Sample Prep Kit drop-down menu, select TruSight Enrichment. c In the Index Reads field, select the number of indexes you will run for the samples: 0, 1, or 2. d Type an experiment name, investigator name, and description. e Select the date. f Select the Paired End Read Type. 2 of 4 Set the number of cycles for each read to 151. Check or uncheck the Workflow-Specific Settings checkboxes, as desired. Click Next. 10 Click Finish and save the sample sheet file. 11 If the Select Included Regions dialog box appears when selecting an Illumina provided manifest file, check which Genomic Targets to include in the results, and then select OK. 12 When prompted, select Yes if you want to review the sample sheet in Microsoft Excel or No to exit the sample sheet wizard without reviewing the sample sheet. Create a HiSeq-, HiScanSQ-, or Genome AnalyzerCompatible Sample Sheet 1 On the IEM main screen, select Create Sample Sheet. 2 On the Instrument Selection screen, select HiSeq, HiScanSQ, GA, and then select Next. 3 On second the Instrument Selection screen, select HiSeq 3000, 4000HiSeq 1500, 2500HiSeq 1000, 2000HiScanSQ, or Genome Analyzer, and then select Next. 4 On the HiSeq Application Selection screen, select the desired application, and then select Next. For TruSight Enrichment, TruSight One, TruSight Cardio, and TruSight Rapid Capture products, the following applications and workflows are supported. Part # 15048138 Rev. C Create TruSight Sample Plates and Sample Sheets with IEM Sample Prep Kit Application in IEM Analysis Workflow 8 Make sure that the required sample ID, index adapters, and Nextera Manifest are displayed. Type a sample name, sample project, and description for each sample, as desired 9 When the wells and samples for every lane in the flow cell have been defined, select Finish and save the sample sheet file in the desired folder. in Sample Sheet Enrichment TruSight Cardio HiSeq Enrichment TruSight Rapid Capture HiSeq FASTQ Only GenerateFASTQ TruSight Enrichment HiSeq Enrichment Enrichment TruSight One 5 On the Workflow Parameters screen, do the following: a In the Reagent Kit Barcode field, enter the reagent kit ID from the label of box 1 or box 2 of the SBS kit. b From the Sample Prep Kit drop-down menu, select Nextera Rapid Capture Enrichment. NOTE The TruSight One and TruSight Rapid Capture kits use the same analysis workflow as Nextera Rapid Capture Enrichment. c d e f g h i 10 When prompted, select Yes if you want to review the sample sheet in Microsoft Excel or No to exit the sample sheet wizard without reviewing the sample sheet. Create a NextSeq-Compatible Sample Sheet NOTE Only the TruSight Enrichment and TruSight Cardio kits are supported by IEM for the NextSeq. 1 On the IEM main screen, select Create Sample Sheet. 2 On the Instrument Selection screen, select NextSeq, and then select Next. 3 On the NextSeq Application Selection screen, select the NextSeq FASTQ Only application for the GenerateFASTQ workflow, and then select Next. 4 On the Workflow Parameters screen, do the following: a In the Reagent Kit Barcode field, enter the reagent kit ID from the label of either box 1 or box 2 of the SBS kit. b In the Index Reads field, select the number of indexes you will run for the samples: 0, 1, or 2. c Type an experiment name, investigator name, and description. d Select the date from the calendar. e Select a Paired End or Single Read sequencing run. f Select the number of cycles for each read in your sequencing run, plus 1. If you are performing a paired-end sequencing run, Illumina recommends performing the same number of cycles in both reads. g Check or uncheck the Workflow-Specific Settings checkboxes, as desired. h Click Next. 5 On the Sample Selection screen, select Select Plate and navigate to the sample plate you created previously. If you have not yet created a sample plate, you can do so now by selecting New Plate. In the Index Reads field, select the number of indexes you will run for the samples: 0, 1, or 2. Type an experiment name, investigator name, and description. Select the date from the calendar. Select the Paired End Read Type. Set the number of cycles for each read to 151 (for HiSeq 2500 Rapid Run mode or GAIIx) or 101 (for HiSeq 2000 or High Output mode). Select or clear the Workflow-Specific Settings checkboxes, as desired. Click Next. 6 On the Sample Selection screen, select Select Plate and navigate to the sample plate you created previously. If you have not yet created a sample plate, you can do so now by selecting New Plate. 7 For each lane you are using in the flow cell, do the following: a Click the lane number: 1 through 8 on the sample sheet area of the screen. b Click Select All to include all wells in this sequencing run or highlight the wells you want to include in this sequencing run. c Click Add Selected Samples. d [Optional] Click Add Blank Row to add rows and manually enter the sample information. 3 of 4 Create TruSight Sample Plates and Sample Sheets with IEM a b c Click Select All to include all wells in this sequencing run or highlight the wells you want to include in this sequencing run. Click Add Selected Samples. [Optional] Click Add Blank Row to add rows and manually enter the sample information. 6 Make sure that the required sample ID, index adapters, and Nextera Manifest are displayed. Type a sample name, sample project, and description for each sample, as desired 7 When the wells and samples have been defined, select Finish and save the sample sheet file in the desired folder. 8 When prompted, select Yes if you want to review the sample sheet in Microsoft Excel or No to exit the sample sheet wizard without reviewing the sample sheet. Technical Assistance For questions, see Illumina Experiment Manager on www.illumina.com. If you do not find the information you need there, contact Illumina Technical Support by email or phone. Copyright and Trademarks © 2015 Illumina, Inc. All rights reserved. Illumina, 24sure, BaseSpace, BeadArray, BlueFish, BlueFuse, BlueGnome, cBot, CSPro, CytoChip, DesignStudio, Epicentre, GAIIx, Genetic Energy, Genome Analyzer, GenomeStudio, GoldenGate, HiScan, HiSeq, HiSeq X, Infinium, iScan, iSelect, MiSeq, NeoPrep, Nextera, NextBio, NextSeq, Powered by Illumina, SeqMonitor, SureMDA, TruGenome, TruSeq, TruSight, Understand Your Genome, UYG, VeraCode, verifi, VeriSeq, the pumpkin orange color, and the streaming bases design are trademarks of Illumina, Inc. and/or its affiliate(s) in the U.S. and/or other countries. All other names, logos, and other trademarks are the property of their respective owners. 4 of 4 Part # 15048138 Rev. C