SureSENS 125LP Monitoring System

Transcription

SureSENS 125LP Monitoring System
OVERVIEW
| bakerhughes.com
SureSENS 125LP Monitoring System
Monitor performance and optimize artificial lift operations
with permanent gauges
Applications
nnHeavy
oil
nnConventional
oil
nnGas
well dewatering
nnLow
marginal wells
nnBottomhole
pressure up to
5,000 psi and temperatures
of up to 257°F
nnRequiring
single, multiple-point, or
differential pressure measurements
Features and benefits
nnSystem
designed and qualified
for reliable operation at 257°F
The SureSENTM 125LP system delivers
critical data on pump pressures and fluid
temperature–all aimed at increasing run
life and improving artificial lift system
performance.
The system is used to monitor artificial lift
parameters via the TEC downhole cable. The
flexibility of the system enables the selection
of a number of parameter measurements,
including single-point zonal pressure
measurements to multiple-point pressure
measurements (multiple zone or intelligent
applications). The SureSENS 125LP system
provides operators with a reliable tool for
accurately maintaining established well
pressures and measuring fluid temperatures,
while optimizing production rates and
reservoir recovery.
SureSENS 125LP system provides
the following parameters:
nnIntake
pressure
nnIntake
temperature
nnDischarge
pressure
nnDischarge
temperature
Contact your Baker Hughes
representative today or visit
www.bakerhughes.com/SureSENS
to find out how the SureSENS 125LP
monitoring system can help you extend
artificial lift run life.
–– Utilizes silicon-on-silicon
transducer
nnSupports
multiple monitoring
devices on a single TEC
–– Deploys multiple gauges for
redundant readings
nnMetal-to-metal
sealing technology
–– Ensures mechanical integrity
of gauge assembly
oVERVIEW
Mechanical Specification
Length
28.9 in.
Diameter
1.50 in.
Weight
6.0 lbs.
Material
Inconel 718
Transducer
Silicon-on-silicon
Transducer option
5,000 psi
Environmental Specification
Temperature rating (operating)
13°F to 257°F
Storage temperature
-67°F to 257°F
Vibration
>5G
Shock
500 G
Measurement Specification
Pressure measurement range (calibrated)
15 – 5,000 psi
Pressure accuracy
+- 5.0 psi
Pressure resolution
0.1 psi
Temperature measurement range (calibrated)
77°F to 257°F
Temperature accuracy
+- 1.8°F
Temperature resolution
0.18ºF
Maximum sample rate / second
1
Number of gauges support / TEC
2
Cable distance transmission
30,000 ft
SureSEN is a trademark of Baker Hughes Incorporated.
Disclaimer of Liability: This information is provided for general information purposes only and is believed to be accurate as of the date hereof; however, Baker Hughes Incorporated and its affiliates do not make any warranties or representations of any kind regarding
the information and disclaim all express and implied warranties or representations to the fullest extent permissible by law, including those of merchantability, fitness for a particular purpose or use, title, non-infringement, accuracy, correctness or completeness of the
information provided herein. All information is furnished “as is” and without any license to distribute. The user agrees to assume all liabilities related to the use of or reliance on such information. BAKER HUGHES INCORPORATED AND ITS AFFILIATES SHALL NOT BE
LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL, PUNITIVE, EXEMPLARY OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER INCLUDING BUT NOT LIMITED TO ITS NEGLIGENCE.
© 2015 Baker Hughes Incorporated. All rights reserved. 42909 03/2015