ThermalStar® LCi-SSâ¢
Transcription
ThermalStar® LCi-SSâ¢
ThermalStar® LCi-SS™ PRODUCT DESCRIPTION Patent pending ThermalStar LCi-SS™ (Laminated Continuous Insulation- Structural Sheathing) is an insulated structural sheathing product with a distinctive orange color. Unlike other nailbase products, the OSB of LCi-SS faces inward, with the insulation on the exterior side. Standard features include: x EPS core with a 7/16” exposure I PS2-10 OSB inside x Alternate products available to meet energy code requirements, R3, R5 or R7.5 x LCi-SS nailing system allows for code prescriptive structural design with no structural compromises x The EPS component has integrated subterranean termite protection and moisture resistance for above grade. See reverse for further details. x Significant reduction in air infiltration and thermal bridging x No requirement to tape nail holes x Qualifies as an air barrier material— E2178 compliant x Qualifies as a water resistant barrier— AC71 compliant x 4’x8’ and 4’x9’ sheets standard, 4’x10’ sheets available upon request x Easy application of most veneer stone, vinyl, wood and fiber cement siding Table 1 TYPICAL USES US Physical Properties Property & ASTM Test Method ThermalStar® LCi-SS™ has been designed specifically to provide continuous exterior insulated structural sheathing in single family, multi-family and light commercial construction. The integrated sheet of 7/16” span rated OSB and nailing system allows uncompromised code prescriptive structural design. Since LCiSS includes the integrated sheet of OSB, it eliminates the need to consult with a structural engineer, unlike competing products. Lastly, it reduces costs and installation time by providing insulation, structural support and a water resistant barrier all in one product. LCi-SS R3 LCi-SS R5 LCi-SS R7.5 Total Thickness (nominal) Compressive strength (minimum psi) @10% deformation D1621 Total R-value (minimum) at 75F mean temperature C518 1-1/16” 1-5/8” 2” 12 12 12 3.0 5.0 7.5 ASTM classification of EPS Type I Type I Type I C578 Vapor permeance E96 desiccant method Total R-value (minimum) at 40F mean temperature C518 Total R-value (minimum) at 25F mean temperature C518 Foam surface burning - flame spread and smoke developed E84 Maximum Use Temperature 3.3 5.4 7.9 3.6 5.7 8.2 Flame spread 5, Smoke developed 170 (meets code) 180F This product is to be installed and treated the same as a typical OSB layer. Proprietary LCi-SS nailgun must be used for installation 7+(50$/ 5(6,67$1&( ,167$//$7,21$1' +$1'/,1* Product R-value: R3—R7.5 ThermalStar LCi-SS can be handled much the same as wood sheathing, using similar tools to cut or otherwise customize panels to fit the R means resistance to heat flow. Class II (0.6 perm), Class III (>1 perm) when perforated application. SENCO LCi-SS nailgun and SENCO nails are required for proper installation. :$55$17< ThermalStar LCi-SS is backed by a limited lifetime warranty. The patent pending SENCO nail gun, specifically created for ThermalStar LCi-SS, and SENCO nails must be used in order for the limited lifetime warranty to apply. For additional product information and availability, please contact: Universal Forest Products www.ufpi.com/ThermalStar 844-610-1771 ThermalStar@ufpi.com ® ® STANDARD SIZES Shear Capacity Typically, ThermalStar LCi-SS is supplied as 4’x8’ or 4’x9’ panels. 4’ x 10’panels are available upon request. The edges of the panels are supplied square cut. LCi-SS is made with 7/16” nominal panel thickness OSB Exposure I 24/16 PS2-10 Sheathing, therefore, code prescriptive shear values apply to this product. Validated by TER report 1311-02. MOLD RESISTANCE The ThermalStar LCi-SS foam core has been tested against 4 week exposure to various mold and fungi via ASTM G21, D3273, and C1338 with no growth of spores on the product. The LCi-SS foam core provides no nutritive value for mold. However, construction practices greatly impact mold growth, and fungi have been known to even grow on glass. FREEZE/ THAW EXPOSURE The ThermalStar LCi-SS foam core has been tested via ASTM C1512 Moisture & Temperature Cycling for Insulation with no loss of physical or thermal performance. This test places the product between a cold chamber and a high humidity chamber with temperature cycling, measuring the effect on the insulation as natural moisture drive occurs. SAFETY MSDS for this product available at www.atlaseps.com. Dust generated from cutting ThermalStar LCi-SS should be avoided using a dust mask as with other building materials. LCi-SS is combustible and the product should be protected from ignition sources such as open flames or welder’s torch. Applications not specifically listed in UL ER16529.1 require permanent separation of LCi-SS from the interior of the building by a thermal barrier such as drywall or concrete for fire safety. ThermalStar® LCi-SS™ SENCO specialty coated nail 8D (2-3/8” x 0.113”) 1-3/4” minimum embedment into stud Spec for OSB 7/16” min Nominal Panel Thickness Exposure I 24/16 PS2-10 Sheathing ThermalStar® Water Resistant Barrier ENVIRONMENTAL ThermalStar LCi-SS uses air in the insulating cells, emitting no gasses. The ppm levels of termiticide incorporated into the polystyrene do not present leaching concerns under typical applications. LCi-SS is readily accepted for recycle. Visit www.epspackaging.org to locate a drop-off location nearest you. TERMITE RESISTANCE This product includes a foam layer that is a treated article. The foam layer is resistant to above grade termite attack at low to moderate levels, against subterranean termites. This product has not been tested for resistance against Formosan Termites. Notes: x OSB is facing inward to increase racking strength x This product is to be installed and treated the same as a typical OSB layer, assuming vertical orientation x Proprietary nail gun must be used to install LCi-SS x SENCO nails must be used for warranty to apply x Joints must be taped using ThermalStar 007 tape or equivalent x Typical vertical nailing– 6” O.C. of the edges and 12” O.C. in the field x Horizontal Nailing—6” O.C. throughout , double nail at horizontal seams &2'(&203/,$1&( ThermalStar LCi-SS complies with the model building codes when properly installed: x x x x DRJ Engineering TER Report 1311-02 Surface Burning – UL BRYX.R16529 Cal Std Reg #CA472 International Energy Conservation Code Physical Properties – UL QORW.R16529 International Residential Code (IRC) – UL ER16529.1 International Building Code (IBC) – UL ER16529.1 Horizontal racking verified via DRJ TER 1311-02 ATLAS, the Globe Logo, Solutions. Delivered., the color Pale Creamy Orange and ThermalStar are registered trademarks of Atlas Roofing Corporation Atlas EPS, a Division of Atlas Roofing Corporation 8240 Byron Center Ave SW, Byron Center, MI 49315 (800) 917-9138 www.atlaseps.com ® ® LIT 1038 Rev 04-07-2015