Power Mod

Transcription

Power Mod
Power Mod™
Commercial K-Base Meter Stacks (type WMK) are designed
to meet the requirements of those utilities specifying
bolt-in meter sockets for 400 and 600 Amp residential and
commercial applications.
Features include:
J QuickSystem™ features
J Exclusive Landis & Gyr K4, K5, & K7 meter sockets
J 1 position K4, K5, K7 modules with 400 & 600 Amp tenant mains
J 2 position K7 module with 400 Amp tenant main
J Space saving design
K-Base quick reference
J 400A & 600A 1-2 positions
J 1200A Thru bus-rating
J UL Standard # UL67
J UL file # E27100
J AIC Rating (25k)
J Voltage
- Single Phase 120/240V AC Max
- Three In Single Phase Out 208Y/120V AC
- Three Phase 240V AC Max
J All swing latches and rivets are stainless steel
J NEMA 3R rated
J G90 Galvanized Steel
J ANSI 61 Paint
K-Base Meter Stacks
www.sea.siemens.com/powermod
Power Mod: K-Base
Features
High quality
Landis & Gyr bolt
on meter base
Connecting cross bus rated
1200 Amps
External main
service disconnect
Provides safety with quick
convenient access to disconnect
made externally. Eliminates taking
time to remove cover to disconnect
s
10-2
|
Power Mod™ with Quick System™
Power Mod: K-Base
Features
Siemens
exclusive
feature
QuickConnect™
QuickConnect reduces bussing
connections from many to
one- ensuring a single reliable
connection instead of multiple
connections.
Mounting ear
Pivot factory installed mounting ears
to minimum or maximum position
to provide additional stability when
mounting equipment onto wall.
QuickTorque™
Eliminates the need for time
consuming torque readings,
this breakaway nut provides the
correct indication of torque of the
QuickConnect. When tightened, the
outer head twists off at the proper
torque for connection, leaving a
single nut for future maintenance.
Siemens
exclusive
feature
QuickBolt™
QuickBolt eliminates the requirement
to line up mechanical connectionsinstead bolts remain retracted until the
openings lineup - allowing the bolts to
protrude through automatically.
Springs push the bolts through and
provide positive pressure to keep bolts
in place while wingnuts are attached
and tightened.
Siemens
exclusive
feature
QuickRoll™
QuickRoll eliminates the typical metal
brackets for mounting modules to the
wall. Instead of metal scraping metal
QuickRoll allows the module to glide
down the mounting rail via a durable
nylon wheel inside mounting bracket.
s
|
Power Mod™ with Quick System™
10-3
Power Mod: K-Base
Catalog numbers
Commercial meter stacks: K-Base bolt-in, 25k AICc f
Meter
positions
per stack
Catalog
number
Max.
tenant breaker
(Amps)
Breaker
provisiond
Depth
Phase
KO
dwg.
no.
KB-1
S-1
KB-1
S-1
Dimensions (inches)a
Height
Width
Schematics
no.
1-phase, 3-wire SN, incoming and outgoing, K4 K-Base bolt-in
WMK11400Rd
1
400
WMK11600R
1
600
JXD62B400
Factory Inst.
LXD62B600
Factory Inst.
54.00
19.25
10.00
—
54.00
19.25
10.00
—
3-phase, 4-wire SN, incoming and 1-phase, 3-wire SN outgoing, K5 K-Base bolt-in
WMK12400RJd
1
400
JXD62B400
Factory Inst.
54.00
19.25
bf
10.00
AB
KB-2
S-2
3-phase, 4-wire SN, incoming and outgoing, K7 K-Base bolt-ine
WMK13400RJd
1
WMK23400RJd
2
WMK13600RJ
1
400
JXD63B400
Factory Inst.
600
LXD63B600
Factory Inst.
54.00
19.25
10.00
—
KB-2
S-3
72.88
27.00
11.00
—
KB-3
S-4
54.00
19.25
10.00
—
KB-2
S-3
a Dimensions shown are representative of outside box dimensions and do not include allowances for mounting bumps, hubs, or hardware protrusions.
b Not for use on 3-Phase 4-wire delta systems
c Max AIC determined by maximum AIC of tenant breakers when used in conjunction with a meter socket. Higher overall ratings may be achieved
through approved series rating combinations
d Alternate amperage breakers are available. Please see table below for suffix that needs to be added for ordering. Extended leadtime may apply. Contact
sales office for more details.
e Rated for use with 240/120V Delta systems
f Commerical Stacks are not field phaseable
Alternate amperage breakers
1 Meter Position
Per Stack
Breaker
Amperage
2 Meter Positions
Per Stack
Breaker
Amperage
T1
T2
T3
200A
250A
300A
T4
350A
T5
T6
T7
T8
T9
T10
T11
T12
T13
T14
T15
T16
T17
200A/200A
200A/250A
200/300A
200/350A
200/400A
250A/300A
250A/350A
250A/400A
300A/300A
300A/350A
300A/400A
350A/350A
350A/400A
Add
Suffix

Add
Suffix

s
10-4
|
Power Mod™ with Quick System™
Power Mod: K-Base
Knockout diagrams
KB-2
WMK12400RJ
WMK13400RJ
WMK13600RJ
KB-1
WMK11400R
WMK11600R
Schematics
NEUTRAL
(POTENTIAL JAW)
A
N
B
C
A
N
B
A
N
B
C
A
N
B
Equip.
Grd.
A
B
S-2
Equip.
Grd.
WMK12400RJ
WMK12400RJ
A
B
S-1
WMK11400R
WMK11400R WMK11600R
HIGH LEG FOR 3Ø,
4 WIRE DELTA SYSTEM
(ALL BRANCH POSITIONS)
WMK11600R
B
A
EQUIPMENT GROUND
NEUTRAL
(POTENTIAL JAW)
C
NEUTRAL
(POTENTIAL JAW)
NEUTRAL
LUGS
A
N
B
C
A
N
B
C
A
N
B
C
A
N
B
C
A
B
C
HIGH LEG FOR 3Ø,
4 WIRE DELTA SYSTEM
Equip.
Grd.
A
B
C
KB-3
HIGH LEG FOR 3Ø,
4 WIRE DELTA SYSTEM
S-3
WMK23400RJ
WMK13400RJ
S-4
WMK23400RJ
WMK13600RJ
WMK13400RJ
WMK13600RJ
s
WMK23400RJ
|
Power Mod™ with Quick System™
10-5
Notes:
Notes:
Catalog Number Logic Example
W
M
K
1
1
400
R
J
Positions
WMK
1
Amperage
WMK = NEMA 3R K-Base
2
400
5th jaw
J = 5th jaw installed (7 jaws for 3-phase in/out)
600
BLANK = No 5th jaw
Phase
Cover
1 = Single phase
R = Ringless
2 = 3-phase in/single out
BLANK = Ring Type
3 = 3-phase
Siemens Energy & Automation, Inc.
Industry Sector
3333 Old Milton Parkway
Alpharetta, GA 30005
1-800-964-4114
info.sea@siemens.com
www.sea.siemens.com/powermod
Subject to change without prior notice
Order No.: RPFL-CSKBS-0409
Printed in USA
© 2009 Siemens Energy & Automation, Inc.
The information provided in this brochure contains merely
general descriptions or characteristics of performance
which in case of actual use do not always apply as described
or which may change as a result of further development
of the products. An obligation to provide the respective
characteristics shall only exist if expressly agreed in the
terms of contract.
All product designations may be trademarks or product
names of Siemens AG or supplier companies whose use by
third parties for their own purposes could violate the rights
of the owners.