Loadline YB3 3P MCCB Installation Instructions
Transcription
Loadline YB3 3P MCCB Installation Instructions
DORMAN SMITH LOADLINE YB3 FRAME Handling Precautions CAUTION Safety Notices WARNING Be sure to read these instructions and other documents accompanying this product. Please familiarise yourself with handling of this product, safety information, and all other precautions before mounting, using, servicing or inspection. In these instructions, safety notices are divided into "Warning" and "Caution" according to the hazard level. Instruction Manual for Moulded Case Circuit Breakers Electrical work should only be undertaken by suitably qualified persons. Do not place the product an an area that is subject to high temperature, high humidity, excessive dust air, corrosive gas, strong vibration and shock, or other unusual conditions. Mounting in such areas could cause a fire or malfunction. WARNING A warning notice with this symbol indicates that neglecting the suggested procedure or practice could result in lethal or serious personal injury. Fixed Type YB3***TF Adjustable Thermal Magnetic Type YB3***T Please retain this manual for future reference.The Manufacturer assumes no responsibility for damages resulting from non-application or incorrect application of the instructions provided herein. Never touch terminals. Otherwise, electric shock may result CAUTION When the breaker trips open automatically, remove the cause, then return the handle to the ON position. Should a fault be interrupted, the breaker must be inspected, otherwise, a fire may result. Be careful to prevent foreign objects (debris, concrete, iron powder etc) and rainwater from entering product. These materials inside the product could cause a fire or malfunction. CAUTION A caution notice with this symbol indicates that neglecting the suggested procedure or practice could result in moderate or slight personal injury and/or property damage. Prior to commencing any work on the product, open an upstream circuit breaker or isolator to ensure that no voltage is applied to the product otherwise electrical shock may result. Note that failing to observe CAUTION notices could result in serious results in some cases. Because safety notices contain important information, be sure to read and observe them. For 4 pole breakers, be sure to connect a neutral conductor to the N-phase pole, otherwise an overcurrent may hinder the product from tripping thus resulting in a fire. Maintenance Precautions CAUTION Service and/or inspection of the product must be done by persons having expert knowledge. Before servicing or inspecting the product, open an upstream circuit breaker or the like to isolate all sources of power. Otherwise, electric shock may result. When connecting cable or busbar to the product, tighten terminal screws to the torque specified in this manual, otherwise, a fire could result. Mounting Precautions For detailed mounting dimensions, refer to either the Loadline or System Loadbank catalogues. Regularly check that the breaker terminal screws are tightened to torque values shown within this manual, failure to do so may result in fire. After conductor connection, do not apply excessive force to the terminals. Otherwise, a fire may result. Other Precautions For front-connected breakers, insulate all bare conductors of the line side until the breaker end. If interpole barriers are packed, be sure to use the barriers; moreover, insulate all bare conductors by insulting tape or the like so that the tape overlaps with the barriers. Insufficient insulation may result in short-circuit. Dorman Smith Switchgear Limited 8 Swinbourne Drive Springwood Industrial Estate Braintree Essex CM7 2YG UK Tel: +44 (0) 844 225 1063 Fax: +44 (0) 844 225 1064 A49914 Packaged Items/Assembly Tools Do not carry this product by accessory leads, as this may cause damage to the product. Unauthorised opening of the breaker cover will invalidate product warranty. When installing the product, use wires or conductors, the cross sectional areas of which accommodate the rated current of the product. Using wires or conductors with inadequate cross sectional areas may cause false tripping and overheat. Do not block the arc gas vents of the product to ensure adequate arc space. Blocking these vents could result in failure of circuit interruption. Operating Instructions Fitting Internal Accessories Alarm Switch YBAL Instr uctio Instruction Manual 1 (This document) n Auxiliary Switch YBAUX1 Breaker Interpole Barrier (Only FC) Shunt Trip TRIPPED Undervoltage Trip YBST** 3P: 2 4P: 3 YBUVR** Symbols of Accessories Ring Mark Auxiliary Switch Handle Type YB3 Trip Button ON Connections/Poles Mounting screw Qty Connecting screw Front Connection 3P 4P 2 4 M4 55 3P 4P 6 8 M8 18 Rear Connection 3P 4P 2 4 M4 55 3P 4P 6 8 M8 25 Plug-in Connection 3P 4P 2 4 M4 65 3P 4P 6 8 M8 Dummy unit OFF b contact a contact b contact 11/AXc-12/AXb 21/AXc-22/AXb 91 /ALc - 91 /ALc 31/AXc-32/AXb 94 /ALa 92 /ALb 41/AXc-42/AXb Shunt Trip power source C1-C2 Combination Undervoltage Trip power source D1-D2 Pull Out Leads on Load Side Removal 4 pole RESET Form the cable Operation 17 10 mm Symbols of Accessories 3 pole Qty a contact 11/AXc-14/AXa 21/AXc-24/AXa 31/AXc-34/AXa 41/AXc-44/AXa Alarm Switch 5 6 (OFF) (ON) TRIP (ON) (OFF) (OFF) Operation effort 53N 57N 91N In case of fiting one (or two) auxiliary switch, fit in an order from a left side-slot. After fitting, verify the function of the Accessory. AX AL SH UV V Adjustable Thermal Magnetic Type Solderless Terminals Mounting Procedure for FC Conductor Connection Procedure for RC/F.P (where applicable) Breaker Mounting Procedure for FC / RC 13 L N Solderless Terminal M YB3CC*P L 5 l i( xl n ) 7 11 9 l R( xl n ) 1 0.8 0.63 OFF End cap Flat Bar Stud YB3RT*P L A M M4 55 mm 1.3 1.7N m N T2FW25LS 23mm 120mm2 6 19N m M6 20mm 6.9 9.3N m O P Q M6 18 mm 7.8 11.8N m 9mm M8 25 mm 11.8 18.6N m R R2 10 Handle Lock Mounting Procedure Conductor Connection Procedure for FC J Handle Lock YBDL1 K Flat Bar YB3XT*P YB3XTS*P J C D E F G H I Interpole Barrier 22mm 11mm 8.4mm 25mm 11mm 7mm 9mm Mounting Procedure J K M8 18 7.8 12.7N m 17 M10 25 22.5 37.2N m 6 Handle lock can be fitted in any position of I (ON) and O (OFF). Insulate all bare conductors of the line side until the breaker end. Time/Current Characteristic Curves Terminal Cover Mounting Procedure In 0.63 0.8 1 /R Adjustment Range Terminal Cover Lock /R Adjustment Range / i Adjustment Range / i Adjustment Range Connection YB3TB Front Connected (FC) Rear/Plug-in Connected (RC / PM) When removing, remove the items in reverse order of mounting. Terminal Cover YB3TS*P YB3TS*PS YB3TC*P When removing, remove the items in reverse order of mounting. In T T 0.63 0.8 1 Interpole Barrier When removing, remove the items in reverse order of mounting. 6 8 10 13 xI n ( I n =100, 125, 160, 200A) I 5 7 9 11 xI n ( I n =250A) I