Folleto LS40 english

Transcription

Folleto LS40 english
LS40
Remote control and monitoring system LS40
E3TLight system allows remote control and monitoring of any new or
existing streetlight network. This control is achieved by installing one
E3TLight device just before the lights section we want to command. With
one unique device we can master from one point of light to whole streets.
LS40 line has been thought to transform one point of light into an smart
element of the Smart City. Whith this device in its different configurations
we can control on/off switching, dimming, power consumption measuring,
air quality measuring, pollution, noise level, temperature, humidity… The
connection to E3TGlobal Cloud is WiFi.
In addition to its point of light main electric parameters measuring, the
equipment allows fail, blinking and stealing detection and on/off switching
scheduled programming.
POWER CONSUMPTION MEASURING
FAIL AND THEFT DETECTION
DIMMING
WIRELESS WIFI CONNECTION
SENSORING
MODBUS CONTROL
WEB DISP.
MySQL db
INT. BUS
DATA
PROCESSING
USER
WEB SERVICE
USER
APPLICATION
EXTERNAL
USER APP.
Laptops
Tablets
Smartphones
Workstations
E3tcity platform allows E3tcity devices stablish point to point connections with
both our cloud and user applications developed by us or third parties .
The implementation of websocket communication, use of REST protocol and
MySQL databases allows fast and easy integration with other platforms.
Technical specifications
Description
Electric parameters
110-230 Vca
50/60 Hz
MAX 400W
-25ºC a +70ºC
Modbus
Dimensions
S1
S3
S2
2 x Power up to 400W
1 x RS485 for sensors and controllers
4 x Analogue inputs for sensors
1 x 1-10 V dimmer
1 x DALI dimmer
Communications
Wi-Fi 802.11 b/g/n 2.4 Ghz.
Power measurements
BALLAST
F
N
Imputs/Outputs
S4
R1-R2 (on/off)
110-230 Vac
e3tcity, S.L.
+34 961 47 65 38
info@e3tcity.com
Calle Literato Gabriel Miró, 19 (bajo)
46008 Valencia (Spain)
182 x 108 x 34mm. (IP65)
Outer antenna 80 mm
Instantaneus power
Voltage
Intensity
Total power consumption
Surges and outages in electric supply
Operating hours
Switch on counter