- FAST Technologies
Transcription
- FAST Technologies
Valve Regulated Lead Acid (VRLA & Sealed Lead Acid (SLA) Battery Switch Tripping Units FAST Technologies battery chargers for switchgear tripping and closing have been developed in partnership with industry leaders. Advantages of a FAST Technologies Battery Tripping units: Ò Vented NiCd or Sealed NiCd battery options Ò 24V, 30V, 50V and 110V models available Ò Standing and non-standing load versions Ò H igh Ambient Temperature versions available up to 70DegC Ò Standard range IP42 - Various IP ratings available Ò W e can build Back plate only or into your own Enclosures Ò Small compact design Ò Competitive pricing Ò Redundancy options for Dual systems Designed to provide a continuous DC supply for operating Ò Proven reliable design switchgear and protection equipment, FSTU series units are Ò Design change flexibility supplied with status indicators, test points and alarms. The robust, reliable units, with remote monitoring as an option are very simple to install and competitively priced. One of the most critical components of a switch tripping Ò CE Marked Ò A ll units undergo extensive testing including Theremographic surveys before leaving the factory. Ò FAST lead times unit is the battery technology used. FAST Technologies have Ò Standard 1 year Warranty integrated Valve Regulated Lead Acid cells due to their Ò FAST Customer Support inherent reliability over a 4 to 17 year plus service life. The advantage of VRLA Batteries: Designed and manufactured in compliance with the RLA & SLA cells use a mature, reliable and wellV understood technology — they are durable and provide dependable service. relevant British and International standards, FAST Low self-discharge —the self-discharge rate is among the lowest in rechargeable battery systems. switch closing and motor rewinding. Low maintenance requirements — no memory; no electrolyte to fill. The standard range covers voltages from 24V to Ò Capable of high discharge rates. Ò Ò Ò Technologies offer a full range of wall mounting and floor standing self-contained units suitable for switch tripping, 110V DC output. CONTINUED g PAGE 2 Valve Regulated Lead Acid (VRLA & Sealed Lead Acid (SLA) Battery Switch Tripping Units Standard Specification Standard VRLA Range Input Voltage Model Reference DC Voltage Tripping Current Standing Load Battery Capacity FSTU/24.2VRLA 24V 30A - 2.5Ah Output Voltage FSTU/SL224.2VRLA 24V 30A 2A 2.5Ah Standard nominal system voltages of 24,30,50 or 110 (other voltages on request). FSTU/24.4VRLA 24V 50A - 4.5Ah FSTU/SL224.4VRLA 24V 50A 2A 4.5Ah FSTU/24.7VRLA 24V 65A - 8Ah Charger FSTU/SL224.8VRLA 24V 65A 2A 8Ah Fully automated, maintenance free Solid state constant voltage (VRLA types) with current limit. Inherently protected against low battery voltage, reversed battery connection and short circuit conditions. FSTU/30.2VRLA 30V 30A - 2.5Ah FSTU/SL230.2VRLA 30V 30A 2A 2.5Ah FSTU/30.4VRLA 30V 50A - 4.5Ah FSTU/SL230.4VRLA 30V 50A 2A 4.5Ah FSTU/30.7VRLA 30V 65A - 8Ah FSTU/SL230.8VRLA 30V 65A 2A 8Ah FSTU/50.2VRLA 50V 30A - 2.5Ah FSTU/SL150.2VRLA 50V 30A 1A 2.5Ah FSTU/SL150.2VRLA 50V 30A 2A 2.3Ah FSTU/50.5VRLA 50V 50A - 4.5Ah FSTU/SL150.4VRLA 50V 50A 1A 4.5Ah Recharge Time FSTU/50.8VRLA 50V 65A - 8Ah Chargers rated to provide 80% recharge within 8 hours and full charge in under 14 hours following a full rated discharge. Faster customised charging schemes available on request. FSTU/SL150.8VRLA 50V 65A 1A 8Ah FSTU/110.2VRLA 110V 30A - 2.5Ah FSTU/SL5110.2VRLA 110V 30A 0.5A 2.5Ah FSTU/SL1110.2VRLA 110V 30A 1A 2.5Ah FSTU/SL2110.2VRLA 110V 30A 2A 2.5Ah FSTU/110.4VRLA 110V 50A - 4.5Ah FSTU/SL5110.4VRLA 110V 50A 0.5A 4.5Ah SL1110.4VRLA 110V 50A 1A 4.5Ah FSTU/110.8VRLA 110V 65A - 8Ah FSTU/SL5110.8VRLA 110V 65A 0.5A 8Ah 230 volts, 50Hz, single phase (other voltages on request) Charger Output Regulation (Ripple) Float voltage controlled to within +/- 1% irrespective of AC mains supply variations of +/- 6% and charger output current variation from 0 to 100%. Ripple voltage is limited to a maximum of 2%rms of the system DC nominal voltage. Instrumentation Voltmeter, Load and Charger Ammeters available - 72mm DIN types to BS89 class 1.5. Monitoring, Control & Displays Options Ò Mains On Ò Battery Impedance Ò Charger Healthy Ò Earth Fault +/ - Ò Mains Fail Ò Circuit Breaker Fault Ò Fuses Ò Charger Fail Ò Battery Fault Ò Temperatures Ò Low Volts Ò Earth Fault Ò High Volts Ò Remote Alarm Facility MCB options for AC Mains Supply Compensation Controls Skeoge Ind. Estate, T +44 (0)28 7135 7740 Beraghmore Road, Derry, F +44 (0)28 7135 7744 Co.Londonderry, E info@fasttechnologies.com N.Ireland, BT48 8SE Ò Ò Other Battery Types Available (Sealed & Vented NiCd)