SERIES PARTIALLY FILLED PIPE ULTRASONIC FLOWMETERS
Transcription
SERIES PARTIALLY FILLED PIPE ULTRASONIC FLOWMETERS
Open channel & partially filled pipe Ultrasonic flow meters SUITABLE FOR PARTIALLY FILLED PIPES AND OPEN CHANNEL FAMOUS PROFESIONAL ULTRASONIC FLOWMETERS MANUFACTURER, ADVANCED TECHNOLOGY, SERIES PARTIALLY FILLED PIPE & OPEN CHANNEL ULTRASONIC FLOWMETERS ARE SUITABLE TO MEASURE THE FLOW OF PARTIALLY FILLED PIPE OR OPEN CHANNEL. Applications Open channel flow Partially filled pipes Water treatment Sewage treatment Irrigation Industrial waste Environmental monitoring DMDF-OP-A Partially Filled Pipe Flow meters PRINCIPAL DMDF-OP-A Partially Filled Pipe Ultrasonic flowmeter is designed for partially filled pipe applications. It has the same measurement as doppler ultrasonic flowmeter of full filled pipe on the fluid velocity measurement. When calculating the flow rate, DMDF-OP-A needs the cross-sectional area of actual flow, so DMDF-OP-A flowmeter also has to measure the level of fluid, then calculate the flow rate. When measuring liquid velocity, the flow meter operates by transmitting an ultrasonic sound from its transmitting transducer, the sound will be reflected by useful sonic reflectors suspended within the liquid and recorded by the receiving transducer. If the sonic reflectors are moving within the sound transmission path, sound waves will be reflected at a frequency shifted (Doppler frequency) from the transmitted frequency. The shift in frequency will be directly related to the speed of the moving particle or bubble. This shift in frequency is interpreted by the instrument and converted to various user defined measuring units. The liquid level measurement principle: the level transducer uses ultrasonic level meter of special small-scale and low dead zone to measure the level. When installing the level meter, user needs to fix a welding base, the height welding base is usually 80~100mm, so it can ensure a high measurement accuracy. The flow formula of partially filled pipe: Q=V·A Where V——Fluid velocity in pipe A——Cross-sectional area of liquid in pipe A is the function of liquid level and inner diameter, A=f(D·h) Where D——Inner diameter of pipe h——Liquid level Features Excellent low flow rate measurement ability, low to 0.05 m/s Automatically signal gain adjustment Complete in specifications, and can provide a variety of applications 4-20mA and RS485/MODBUS output, GPRS is optional Very suitable for large pipe sewage measurement International explosion proof certificate DMDF-OP-A flow meter includes flow calculator, transmitter, velocity transducer and level transducer. DMDF-OP-A Fixed Partially Filled Pipe Flow meters (If installation environment requires explosion-proof, please contact manufacturer to order DMDF-OP-A Explosion-proof partially Filled Pipe Flow meters.) Measuring Diagram Velocity and Level Measurement Velocity and Level Measurement Flow Calculator The flow calculator can set the cross-sectional area calculation of partially filled pipe or open channel, for circular pipe, it only need to input the inner diameter; for open channel, it only need to input the width; users also can input up to 20 point coordinates of channel to calculate the cross-sectional area. The flow calculator can display the velocity, level, flow rate and flow totalizer, and is configured with 4-20mA and, RS485/MODBUS output, GPRS is optional. Fixed Flow Calculator Transmitter The transmitter and level transducer output 4-20mA analog signal of the velocity and level, which are connected to the two external 4-20mA input of flow calculator. Transmitter Velocity Transducer The velocity transducer includes two types: Clamp-on and Insertion, both of them are hot-tapped installation and demounted online. Clamp-on Velocity Transducer Installation Drawing of Insertion Velocity Transducer When installing the insertion velocity transducer, the pipe can’t be welded directly, such as cement pipe, ductile iron or other unweldable material, please notify manufacturer for extended velocity transducers (wall thickness of pipe can be up to 110mm) shown as below. In this case, it also need to install a weldable (usually carbon steel) hoop shown as below. Extended Velocity Transducers Installation Drawing of Weldable Hoop Level Transducer The measurement principle of level transducer: the level transducer uses ultrasonic level meter of special small-scale and low dead zone to measure the level. When installing the level meter, user needs to fix a welding base, the height welding base is usually 80 ~ 100mm, so it can ensure a high measurement accuracy. TECHNICAL SPECIFICATIONS Accuracy 1.0~2.0%F.S. Pipe Sizes DN100~3000 Liquid Types Liquids containing 100 ppm of reflectors and at least 20% of the reflectors are larger than 100 micron. Flow Calculator Enclosure NEMA 4X [IP65], cast aluminum 260L×193W×80H (mm), 10.2L×7.6W×3.2H(inch) Power Supply Standard: 100~240VAC, 50/60HZ ±5%, 5VA Max Optional: 12~28VDC, 2.5VA Max 4-20mA, RS485/Modbus, GPRS (optional) Outputs Temperature -40 to +70℃ Transmitter Enclosure NEMA 4X [IP65], cast aluminum 260L×193W×80H (mm), 10.2L×7.6W×3.2H(inch) Power Supply Standard: 100~240VAC, 50/60HZ ±5%, 5VA Max Optional: 12~28VDC, 2.5VA Max 4-20mA Outputs Temperature -40 to +70℃ Velocity Transducer Measuring Range Type 0.05m/s ~12m/s Clamp-on and Insertion Liquid Temperature Standard: -40℃~+121℃ High temp: -40℃~+250℃ -40℃~+150℃(Stainless Steel) Cable Length Standard Lengths: 20Feet [6m] Optional Lengths: to 990 Feet [300m] Housing Material Standard Transducer: Aluminum High Temp Transducer: Engineering plastic Stainless Steel Transducer: Stainless Steel Insertion Transducer: Stainless Steel Protection Class Standard IP65 Optional IP68, can work under water Level Transducer Measuring Range 0.5 to 18 feet (0.15m to 5.4m) Temperature -40 to +60℃ Power Supply 12-36 VDC Outputs Housing Material 4-20mA Engineering plastic, NEMA 4X [IP65] Model Selection Table of DMDF-OP-A Fixed Flow meters MODEL: DMDF-OP-A -X -X -X -X -DOPF -X -X -X -X -X -X Flow Calculator F-Fixed Transmitter F-Fixed Power Supply A-110VAC B-220VAC E-24VDC S-Solar Supply Output N- None R-RS485 M-Modbus G-GPRS Velocity Transducer 1-Standard Clamp-on (DN40~4000) 2-Standard Insertion (DN65~4000) 3-Extended Insertion (DN65~4000) Velocity Transducer Material N-Standard material S-Stainless Steel (Only for Standard Clamp-on) Velocity Transducer Protction Class N- IP65 O- IP68, can work under water Liquid Temperature N- -40~121℃ H1- -40~250℃ H2- -40~150℃(high temperature for stainless steel transducer material) Cable Length of Velocity Transducer 020-20Feet (6m) XXX-Optional, up to 990 Feet (300m) Level Transducer N-Standard D1-DynaProbe level meter (Compact type) D2-DynaProbe level meter (Remote type) Example: DMDF-OP-A-F-F-B-G-DOPP-1-N-N-N-020-N means fixed flow meters; 220VAC power supply; Need GPRS output; velocity transducer is standard clamp-on, Aluminum material, protection class: IP65; Liquid Temperature is -40 to 121℃; the cable length of velocity transducer is 20 Feet; Level transducer is standard. DMDF-OP-A Portable Partially Filled Pipe Flow meters Flow Calculator Measuring diagram Portable Flow Calculator The flow calculator can set the cross-sectional area calculation of partially filled pipe or open channel, for circular pipe, it only need to input the inner diameter; for open channel, it only need to input the width; users also can input up to 20 point coordinates of channel to calculate the cross-sectional area. The flow calculator can display the velocity, level, flow rate and flow totalizer, and is configured with 4-20mA and RS485/MODBUS output, GPRS is optional. Transmitter Portable Transmitter Velocity Transducer Clamp-on Velocity Transducer Level Transducer The measurement principle of level transducer: the level transducer uses ultrasonic level meter of special small-scale and low dead zone to measure the level. When installing the level meter, user needs to fix a welding base, the height welding base is usually 80 ~ 100mm, so it can ensure a high measurement accuracy. The transmitter and level transducer output 4-20mA analog signal of the velocity and level, which are connected to the two external 4-20mA input of flow calculator. TECHNICAL SPECIFICATIONS Accuracy 1.0~2.0%F.S. Pipe Sizes DN100~3000 Liquid Types Liquids containing 100 ppm of reflectors and at least 20% of the reflectors are larger than 100 micron. Flow Calculator Enclosure Power Supply Outputs Temperature NEMA 4X [IP65], ABS 358L×250W×150H (mm), 14.1L×9.8W×5.9H(inch) rechargeable lithium battery, 12VDC, 14.4Ah Over 50 hours working time on a full-charge Charger: 100~240VAC, 50/60 HZ ±5%, 3A Max 4-20mA, RS485/Modbus, GPRS (optional) -40 to +70℃ Transmitter Enclosure Power Supply Outputs Temperature NEMA 4X [IP65], ABS 358L×250W×150H (mm), 14.1L×9.8W×5.9H(inch) rechargeable lithium battery, 12VDC, 14.4Ah Over 50 hours working time on a full-charge Charger: 100~240VAC, 50/60 HZ ±5%, 3A Max 4-20mA -40 to +70℃ Velocity Transducer Measuring Range Type 0.05m/s ~12m/s Clamp-on Liquid Temperature Standard: -40℃~+121℃ High temp: -40℃~+250℃ -40℃~+150℃(Stainless Steel) Cable Length Standard Lengths: 20Feet [6m] Optional Lengths: to 990 Feet [300m] Housing Material Standard Transducer: Aluminum High Temp Transducer: Engineering plastic Stainless Steel Transducer: Stainless Steel Protection Class Standard IP65 Optional IP68, can work under water Level Transducer Measuring Range 0.5 to 18 feet (0.15m to 5.4m) Temperature -40 to +60℃ Power Supply 12-36 VDC Outputs Housing Material 4-20mA Engineering plastic, NEMA 4X [IP65] Model Selection Table of DMDF-OP-A Portable Flow meters MODEL DMDF-OP-A -X -X -X -X -X –DOPP -X -X -X -X -X -X Flow Calculator P- Portable Transmitter P- Portable Power Supply A—115VAC (Two round terminals) B—230VAC (Two round terminals) C—110VAC (Two rectangular terminals) D—230VAC (Two rectangular terminals) Output N-None R-RS485 M-Modbus G-GPRS Extend operation time N- Normal E- Extend the operation time to 120 hours Velocity Transducer 1-Standard Clamp-on (DN40~4000) Velocity Transducer Material N-Standard material S-Stainless Steel Velocity Transducer Protction Class N- IP65 O- IP68, can work under water Liquid Temperature N- -40~121℃ H1- -40~250℃ H2- -40~150℃(high temperature for stainless steel transducer material) Cable Length of Velocity Transducer 020-20Feet (6m) XXX-Optional, up to 990 Feet (300m) Level Transducer N-Standard D1-DynaProbe level meter (Compact type) D2-DynaProbe level meter (Remote type) Example: DMDF-OP-A-P-P-A-G-N-DOPP-1-S-N-020-N means portable flow meters; 115VAC power supply; Need GPRS output; Normal battery; velocity transducer is standard clamp-on, Stainless Steel; Liquid Temperature is -40 to 121℃; the cable length of velocity transducer is 20 Feet; Standard level meter. DMDF-OP-B Partially Filled Pipe Flow meters PRINCIPAL DMDF-OP-B Ultrasonic flowmeter is designed for partially filled pipe and open channel applications. It has the same measurement as doppler ultrasonic flowmeter of full filled pipe on the fluid velocity measurement. When calculating the flow rate, DMDF-OP-B needs the cross-sectional area of actual flow, so DMDF-OP-B flowmeter also has to measure the level of fluid, then calculate the flow rate. When measuring liquid velocity, the flow meter operates by transmitting an ultrasonic sound from its transmitting transducer, the sound will be reflected by useful sonic reflectors suspended within the liquid and recorded by the receiving transducer. If the sonic reflectors are moving within the sound transmission path, sound waves will be reflected at a frequency shifted (Doppler frequency) from the transmitted frequency. The shift in frequency will be directly related to the speed of the moving particle or bubble. This shift in frequency is interpreted by the instrument and converted to various user defined measuring units. When measuring liquid level, place the DYNAMETERS transducer on or near the bottom watershed, through water static pressure sensor which is in transducer, and the power supply signal cable has ventilation effect, water static pressure sensor sets Atmospheric pressure on the water surface as reference pressure to measure the fluid pressure, then calculates liquid level. The flow formula of partially filled pipe: Q=V·A Where V——Fluid velocity in pipe A——Cross-sectional area of liquid in pipe A is the function of liquid level and inner diameter, A=f(D·h) Where D——Inner diameter of pipe h——Liquid level Features Excellent low flow rate measurement ability, low to 0.021 m/s Superior measurement accuracy 4-20mA and RS485/MODBUS output, GPRS is optional Very suitable for sewage measurement User-friendly configurations Complete in specifications, and can provide a variety of applications DMDF-OP -B Flow Meter includes flow calculator, DYNAMETERS velocity and level transducer. It is suitable for the flow measurement of pipe outlet and open channel. DMDF-OP-B Fixed Partially Filled Pipe Flow meters Flow Calculator Series DMDF-OP -B Fixed Flow meters Fixed Flow Calculator The flow calculator can set the calculate the cross-sectional area of partially filled pipe or open channel, for circular pipe, it only need to input the inner diameter; for open channel, it only need to input the width; users also can input up to 20 point coordinates of channel to calculate the cross-sectional area. The flow calculator can display the velocity, level, flow rate and flow totalizer, and is configured with 4-20mA and RS485/MODBUS output, GPRS is optional. DYNAMETERS Velocity and Level Transducer By using digital signal processing techniques, DYNAMETERS velocity and level transducer is able to perform in a wide range of environments. It is used to record flows in pipes, channels and small streams and operates in a wide range of water qualities from fresh streams to primary sewage channels. DYNAMETERS velocity and level transducer combines water velocity and water depth measurement with a powerful data logger. Its systems have been tested in small streams and pipes, and the calibration has been verified in a tow tank. DYNAMETERS velocity and level transducer is mounted on (or near to) the bottom of the stream/pipe/culvert and measures the velocity and depth of the water flowing above it. DYNAMETERS Velocity and Level Transducer Installation Drawing of Transducer When installing transducer, a hoop as shown above is needed, at first, fix the transducer on the hoop, then fix the component in the pipe, and connect the cable to flow calculator. TECHNICAL SPECIFICATIONS Pipe Sizes DN300~2000 Flow Calculator Enclosure Power Supply Outputs Temperature NEMA 4X [IP65], cast aluminum 260L×193W×80H (mm), 10.2L×7.6W×3.2H(inch) 100~240VAC, 50/60 HZ ±5%, 5VA Max Or 12~28VDC, 2.5VA Max. 4-20mA, RS485/Modbus, GPRS(optional) -40 to +70℃ DYNAMETERS Velocity and Level Transducer Enclosure 290L×70W×25H(mm); 11.4L×2.8W×1H(inch) Material PVC body, Stainless steel mounting plate Accuracy Velocity 2% of measured Level ±0.25% of calibrated lower range Velocity 0.021m/s to 4.5m/s bidirectional Level 0 to 2m(021) 0 to 5m(051) Measuring Range Temperature 0°C to 60°C water temperature Cable Length 15 meters, 9 way vented cable «SQL» Compatible Power Supply Battery External 12VDC Voltage 11.5V to 15VDC Model Selection Table of DMDF-OP -B fixed flow meters MODEL DMDF-OP -B -X -X -X -X Flow Calculator F-Fixed Power Supply A-110VAC B-220VAC E-24VDC S-Solar Supply Output N-None R-RS485 M-Modbus G-GPRS Level Range 21-0 to 2m(021) 51-0 to 5m(051) Example: DMDF-OP -B-F-B-G-21 means fixed flowmeters, 220VAC power supply; GPRS output, and the level range is 0 to 2m. DMDF-OP-B Portable Partially Filled Pipe Flow meters Flow Calculator Series DMDF-OP -B Portable Flow meters Portable Flow Calculator The flow calculator can set the calculate the cross-sectional area of partially filled pipe or open channel, for circular pipe, it only need to input the inner diameter; for open channel, it only need to input the width; users also can input up to 20 point coordinates of channel to calculate the cross-sectional area. The flow calculator can display the velocity, level, flow rate and flow totalizer, and is configured with 4-20mA and RS485/MODBUS output, GPRS is optional. DYNAMETERS Velocity and Level Transducer By using digital signal processing techniques, DYNAMETERS velocity and level transducer is able to perform in a wide range of environments. It is used to record flows in pipes, channels and small streams and operates in a wide range of water qualities from fresh streams to primary sewage channels. DYNAMETERS velocity and level transducer combines water velocity and water depth measurement with a powerful data logger. Its systems have been tested in small streams and pipes, and the calibration has been verified in a tow tank. DYNAMETERS velocity and level transducer is mounted on (or near to) the bottom of the stream/pipe/culvert and measures the velocity and depth of the water flowing above it. DYNAMETERS Velocity and Level Transducer Installation Drawing of Transducer When installing transducer, a hoop as shown above is needed, at first, fix the transducer on the hoop, then fix the component in the pipe, and connect the cable to flow calculator. TECHNICAL SPECIFICATIONS Pipe Sizes DN300~2000 Flow Calculator Enclosure Power Supply Outputs Temperature NEMA 4X [IP65], ABS 358L×250W×150H (mm), 14.1L×9.8W×5.9H(inch) rechargeable lithium battery, 12VDC, 14.4Ah, Over 50 hours working time on a full-charge Charger: 100~240VAC, 50/60 HZ ±5%, 3A Max 4-20mA, RS485/Modbus, GPRS (optional) -40 to +70℃ DYNAMETERS Velocity and Level Transducer Enclosure 290L×70W×25H(mm); 11.4L×2.8W×1H(inch) Material PVC body, Stainless steel mounting plate Accuracy Velocity Measuring Range 2% of measured Level ±0.25% of calibrated lower range Velocity 0.021m/s to 4.5m/s bidirectional Level 0 to 2m(021) 0 to 5m(051) Temperature 0°C to 60°C water temperature Cable Length 15 meters, 9 way vented cable «SQL» Compatible Power Supply Battery External 12VDC Voltage 11.5V to 15VDC Model Selection Table of DMDF-OP -B Portable flowmeters MODEL DMDF-OP -B -X -X -X -X -X Flow Calculator P-Portable Power Supply A—115VAC (Two round terminals) B—230VAC (Two round terminals) C—110VAC (Two rectangular terminals) D—230VAC (Two rectangular terminals) Output N-None R-RS485 M-Modbus G-GPRS Level Range 21-0 to 2m(021) 51-0 to 5m(051) Extend operation time N- Normal E- Extend the operation time to 120 hours Example: DMDF-OP -B-P-A-G-21-E means portable flowmeters, 115VAC power supply; GPRS output, and the level range is 0 to 2m, Extend the operation time to 120 hours.