Submersible Turbine Pumps Owner`s Manual

Transcription

Submersible Turbine Pumps Owner`s Manual
SUBMERSIBLE TURBINE
PUMPS
OWNER'S MANUAL
READ AND FOLLOW SAFETY INSTRUCTIONS
This is the safety alert symbol. When you see this
symbol on your pump or in this manual, look for one
of the following signal words and be alert to the potential
for personal injury:
D A N G E R warns about hazards that will cause
serious personal injury, death or major property damage
if ignored.
W A R N I N G warns about hazards that can cause
serious personal injury, death or major property damage
if ignored.
C A U T I O N warns about hazards that will or can
cause minor personal injury or major property damage if
ignored.
The label NOTICE indicates special instructions, which
are important but not related to hazards.
Carefully read and follow all
WA R N I N G safety instructions in this
manual and on pump.
Keep safety labels in good
condition.
Replace missing or damaged
safety labels.
Hazardous voltage.
Can shock, burn, or
cause death.
BEFORE INSTALLING PUMP, BE SURE TO READ
THIS OWNER’S MANUAL CAREFULLY.
INSPECT THE SHIPMENT
Examine the pump when it is received to be sure there
has been no damage in shipping. Should any be evident,
report it immediately to the transportation company and
ask to have it inspected. Check the pump nameplate to
ensure you have received the correct pump unit.
Ground motor before
connecting to power
supply. Disconnect
power before working
on pump, motor
or tank.
SUBMERSIBLE TURBINE PUMPS
CONTENTS
Inspection-Receipt of Equipment............................. Sec. A
Equipment and Installation Record.......................... Sec. B
General Information.................................................. Sec. C
Suitability of the Well................................................ Sec. D
Installation-Site & Support Equipment...................... Sec. E
Pump to Motor Assembly......................................... Sec. F
Pump/Motor Installation............................................ Sec. G
Accessories with Installation.....................................Sec. H
Operational Checkup................................................ Sec. I
Troubleshooting.........................................................Sec. J
A. INSPECTION-RECEIPT OF EQUIPMENT
Examine equipment at the time of receipt. Handle the pump, cable and motor carefully. This is very important because
of the precise alignment of the assembly and the vulnerability of the cable. Report any damages or shortages
immediately to the freight carrier agent and make notes on the freight bill of lading. This will facilitate a satisfactory
and prompt processing of a claim adjustment.
B. EQUIPMENT INSTALLATION RECORD
*Record the following details at the time of the installation and retain for future references:
RMA No. _____________
DISTRIBUTOR
INSTALLER
END USER
Name: _________________________
Name: _________________________
Name: _________________________
City: __________________________
City: __________________________
City: __________________________
State: ___________ Zip: __________
State: ___________ Zip: __________
State: ___________ Zip: __________
Well ID or GPS: __________ ___________ ______________________ Water Temperature: _____________
 °F  °C
Application/Water Use (e.g. potable water, irrigation, municipal, fountain, etc.): ___________________________________
 Yes  No
Operating Cycle: ON Time Per Start _____  Hrs.  Mins. Time OFF Between Stop & Restart _____  Hrs.  Mins.
Date Installed (mm/yy): _____________ Date Failed (mm/yy):_____________ Motor Position Shaft-Up:
MOTOR
Model: ______________________ Serial Number: __________________________ Date Code (if updated): __________
MOTOR OVERLOAD
System Typical Operating Current: _______________ Amps @ _______________ Volts
 FE SubMonitor Input Amps _______ D3 Attached  Yes  No Fault Settings Attached  Yes  No
 Other Manufacturer Model: _______________________ Dial Set at: __________ or Heater# __________
NEMA Class:  10  20  30
Ambient Compensated:  Yes  No
Power to Motor by:  Full Volt Starter  VFD  Soft Starter VFD or Soft Starter Mfr. & Model: ___________________
Overload:
PUMP
PUMP
DATA (All measurements from well head down.)
WELL DATA
Casing Diameter ______________________ in
Manufacturer:
Manufacturer:_________________________
_________________________
Casing Diameter ______________________ in
Model:
Model: ______________________________
______________________________
Drop
Pipe ofDiameter
____________________
in
Number
Sticks of Drop
Pipe _____________
Stages:
Stages:______________________________
______________________________
Static Water
Levelof
_____________________
ft
Number
of Sticks
Drop Pipe _____________
Design
Design Rating:
Rating: _______
_______ gpm
gpm @
@ _______
_______ ftft TDH
TDH
Static Water Level _____________________ ft
Horsepower
Horsepower Required
Required by
by Pump
Pump End:
End: ___________
___________
Drawdown
Water
Level _________ ft
(Measured(pumping)
from Well Head
Down)
Actual
Actual Pump
Pump Delivery:
Delivery: _______
_______ gpm
gpm @
@ _______
_______ psi
psi
#1 ______
#3 ______ #4______ ft
Spring
Assist#2______
Check Valves:
(Measured
from
Well
Head
Solid
Drilled Poppet Down)
Break-Off Plug
Drop Pipe Diameter ____________________ in
What
What Controls
Controls When
When System
System Runs
Runs &
& Stops:
Stops:
_________________________________________
_________________________________________
(e.g.
(e.g. pressure,
pressure, level,
level, flow,
flow, manual
manual on/off,
on/off, timer,
timer,
time
time clock
clock etc.)
etc.)
Drawdown (pumping) Water Level _________ ft
Spring Assist Check Valves:

#1


Pump Inlet #2______
Setting ____________________
ft
______
#3 ______ #4______
ft
Drilled
Poppet Break-Off Plug
 Solid 
Flow Sleeve
No
Yes, Dia._________ in
Case Ends ___________________________ ft
Pump Inlet Setting ____________________ ft
 Well Screen  Perforated Casing
 
No & #2Yes,
_________ in
Flow
#1 Sleeve
from ____to____ft
from Dia.
____to____ft
WellEnds
Depth___________________________
___________________________ ft
Case
YOUR NAME / DATE
 Well Screen  Perforated Casing
#1 from ____to____ft & #2 from ____to____ft
ft
B. EQUIPMENT INSTALLATION RECORD CON’T.
TRANSFORMERS
Number of Transformers:
 Two  Three
Transformer #1: __________ kVA
Transformers Supply Motor Only:
Transformer #2: __________ kVA
 Yes  No  Unsure
Transformer #3: __________ kVA
POWER CABLES & GROUND WIRE
Service Entrance to Pump Control Panel:
1
Length: __________ ft. & Gauge: __________ AWG/MCM
Construction:  Jacketed  Individual Conductors  Web  Twisted
 Copper  Aluminum
Temperature Rating of Cable:  60C  75C  90C  125C or Insulation Type: ________________ (e.g. THHN)
Material:
Pump Control Panel to Motor:
2
Length: __________ ft. & Gauge: __________ AWG/MCM
Construction:  Jacketed  Individual Conductors  Web  Twisted
 Copper  Aluminum
Temperature Rating of Cable:  60C  75C  90C  125C or Insulation Type: ________________ (e.g. THHN)
Material:
Ground Wire Size: From Control Panel to Motor: __________ AWG/MCM
3 Control Grounded to (mark all that apply):
Well Head
Metal Casing
Motor



 Driven Rod  Power Supply
INCOMING VOLTAGE
RUNNING AMPS & CURRENT BALANCE
No Load
L1-L2 ______ L2-L3 ______ L1-L3 ______
Full Load
Full Load
L1-L2 ______ L2-L3 ______ L1-L3 ______
% Unbalance: ______
L1 ________ L2 ________ L3 ________
CONTROL PANEL
1 Pump Panel Manufacturer/Fabricator: _______________________________________________________________
Short Circuit Protection - Fuses or Circuit Breaker
Option #1 - Fuse
2
Manufacturer: __________________ Model: __________________ Rating: ____________ Amps
Type:
 Time-Delay  Standard
Option #2 - Circuit Breaker
Manufacturer: __________________ Model: __________________ Rating: ___________ Amps Setting: _________
Starter - Full Voltage, Reduced Voltage, Soft-Starter or VFD (Variable Frequency Drive)
Option #1 - Full Voltage
Manufacturer: __________________ Model: ________________ Size: ____________ Contacts:
 NEMA  IEC
Option #2 - Reduced Voltage
Manufacturer: __________________ Model: __________________ Ramp Time to Full Voltage: _____________ sec.
3 Option #3 - Soft-Starter or VFD
Manufacturer: __________________ Model: __________________ Max. Continuous Amp Output Rating: _________
Min. Setting: ____________ Hz & GPM: ____________
Start Ramp Time to 30 Hz: ________ sec.
Special Output Filter Purchased:
 Yes  No
Stop Mode:
Max. Setting: ____________ Hz & GPM: ____________
 Power Off Coast  30-0 Hz Ramp ________ sec.
Output Filter Manufacturer: ______________________ Model: ______________________ % Reactance: _________
4 Surge Arrestor:
 No  Yes, Manufacturer: ____________________ Model: ____________________
C. GENERAL INFORMATION
The submersible pump unit comprises of a vertical turbine
pump assembly directly-coupled to a submersible electric
motor. The connecting bracket accommodates the
coupling between the pump and motor shafts and also
serves as the water intake passage.
The pump unit is suspended in the well by the riser pipe,
and the electric power is taken down from the well head to
the motor by the submersible cable which is secured at
intervals to the riser pipe.
Please read the manufacturer’s separate instruction
manual for the motor, and keep it for future reference.
D. SUITABILITY OF THE WELL
Submersible pumps as well as all water pumps, are
designed to handle clean, cool, clear water. Water from an
undeveloped well often contains excessive amounts of
sand, dirt and other abrasives which can cause damage to
the pump.
Install the pump in a well which has already been properly
developed with a test pump.
The test pump also provides a means to match the
capacity and setting of the pump to the yield of the well. If
the pump removes water at a higher rate than the well
produces, the drawdown will be excessive and this will
cause the pump to pump air, and result in damage to the
pump or motor.
The well must be deep enough so that the pump suction is
at least 10 ft. below the expected drawdown level.
The inside diameter of the well casing must be large
enough to allow lowering the unit into the well without
damage to the power cable and the splice between the
power cable and the motor leads. Check that the well is
large enough to allow installation of the pump at the
required depth. Keep the bottom of the motor at least 10
ft. from the bottom of the well, particularly where there is a
history of sand in the well. Do not install the pump or
motor within the perforations in the well casing unless the
well size permits the installation of a flow sleeve over unit
to ensure an adequate flow of water over the motor for
cooling purposes.
Submersible motors require a minimum cooling flow.
Please refer to the motor manufacture's applications,
installation, maintenance manual (AIM Manual) for motor
cooling requirements.
CAUTION
DO NOT INSTALL THE UNIT WITH THE MOTOR
RESTING ON THE BOTTOM, OR CLOSER THAN 10 FT.
FROM THE BOTTOM OF THE WELL.
E. INSTALLATION
SITE & SUPPORT EQUIPMENT
Equipment & Material Required:
The material and equipment necessary for the installation
of the pump will vary with the pump size and type of
installation. The following is a general list of needed tools
and supplies.
Materials: Anti-galling lubricant, thread compound,
lubricating oil, grease.
Tools & Instruments: Tripod with chain blocks, or rig with
power hoist, pipe clamps, megger, pipe wrenches, and
mechanical tools.
Be sure that the equipment is strong enough to lift the total
weight of the pump and motor assembly, riser pipe and
water in the riser pipes.
FOUNDATION
Construct a concrete foundation which must be RIGID,
LEVEL and of adequate STRENGTH to support the
complete weight of the pump, motor, column, plus the
weight of the water pumping through it without exceeding
the permissible bearing pressure for the subsoil.
Support the riser pipe at the well head with a well seal,
surface plate, or other adapter which seals the well in
accordance with local regulations. Make provision for a
conduit to carry the power cable into the well in
accordance with local regulations.
RISER PIPE
Make up the riser pipe from random lengths of threaded
and coupled pipe, and make arrangements to secure it at
the well by a well seal, surface plate, or other adapter.
Take great care to keep pipes clean and free from
pebbles, scale, and thread chips. Tighten each joint
securely as recommended by the AIM manual.
CHECK VALVES
It is recommended that one or more check valves
always be used in submersible pump installations. If the
pump does not have a built-in check valve, an in-line
check valve should be installed in the discharge line
within 25 feet of the pump and below the draw down
level of the water supply. For deeper settings, check
valves should be installed per the manufacturer’s
recommendations. More than one check valve may be
required, but more than the recommended number of
check valves should not be used.NT
F. PUMP TO MOTOR ASSEMBLY
Pump should be assembled to the motor at the installation
site. Always assemble pump to motor vertically to reduce
strain on pump coupling and motor shaft. Assembling the
pump and motor horizontally or on angle may result in
damage to the pump shaft, coupling, or motor shaft.
Please refer to the 8x8 Coupling Installation Procedure
located at the end of this manual for instructions on
assembling 8” pumps to 8” motors. After assembling
the pump to the motor, utilize the motor bolt kit to secure
the pump to the motor. Torque fasteners to the
specifications below:
4” MOTOR: 10 lb-ft (14 Nm)
6” MOTOR: 50 lb-ft (68 Nm)
8” MOTOR: 120 lb-ft (163 Nm)
Please refer to the AIM for the most up-to-date torque
information.
Position the motor lead along the length of the pump.
Place the cable guard on top of the motor lead. Pull motor
lead tight to ensure it is properly covered by the cable
guard. Use cable guard fasteners to secure cable guard
to pump. Torque cable guard fasteners to 20-23 lb-in
(2.26-2.60 Nm). NOTE: For 5” STS cable guard
installation, utilize cable guard clamp to secure top of
cable guard. Locate cable guard clamp on the neck of the
top bowl and tighten clamp fastener to 20-23 lb-in (2.262.60 Nm). Cable guard clamp must be located on the
neck of the top bowl to ensure cable clamp’s future
position and pump’s maximum outside diameter.
CAUTION
PUMP AND MOTOR MUST BE ASSEMBLED
VERTICALLY. FAILURE TO ASSEMBLE VERTICALLY
MAY RESULT IN DAMAGE TO PUMP COUPLING
OR MOTOR SHAFT.
G. PUMP/MOTOR INSTALLATION
Thread the first length of riser pipe into the pump
discharge and raise the pump and pipe into a vertical
position over the motor. Refer to the AIM manual for
installation recommendations. Be careful not to drag the
pump and motor assembly along the ground, or let it strike
other objects while placing the assembly over the well.
Lower the pump about 10 ft. into the well and fasten the
cable to the riser pipe to prevent tangling and damage.
Continue to add lengths in the same manner until the
required pump setting is reached. Secure the cable to the
riser pipe at regular intervals.
CAUTION
TAKE GREAT CARE TO PREVENT DAMAGE TO THE
CABLE DURING INSTALLATION.
Where a bleeder type air charging kit is used with a
hydro pneumatic tank, install the tee and bleeder valve
before adding the last length of riser pipe. This will place
the bleeder valve about 20 ft. below the well head.
Place the sanitary well seal, surface plate, or other
adapter on the last length of riser pipe and pass the
submersible cable through the opening provided. Then
attach the discharge tee or elbow to the riser pipe.
Lower the riser pipe to its final position and tighten the
well seal or other device to support the installation in
the well.
INITIAL START-UP & PERFORMANCE CHECK
Check the pump and well performance before making the
final connection to the discharge system.
1. Install a pressure gauge and gate valve on the end of
the pipe. Close the valve.
2. Start the pump, check the pressure developed
against the closed valve. If the pressure is substantially
less than expected (Please allow for the depth of the
water level), the pump may be running backward. To
change the rotation of a three phase motor, interchange
any two leads.
3. Open the gate valve to produce a low flow. Open the
gate valve gradually until full flow is achieved.
4. Use a clamp-on amp meter to read the current, which
should approximate the full-load current given on the
motor nameplate, but must not exceed the service
factor rating of the motor. The service factor varies with
the model of the motor. Consult the factory if insufficient
information is given about Service Factor performance.
Check that the currents in the individual phases of a
3-phase system are approximately equal. Where there is
considerable difference between them, change all 3
connections at the starter as shown below (so that rotation
remains the same) to obtain the most consistent readings.
Starter
cable (1)
cable (2)
cable (3)
L1
black
red
yellow
L2
yellow
black
red
L3
red
yellow
black
Then subtract the average of the readings from the highest.
The difference, expressed as a percent of the average must
not exceed 5%. Note that the highest reading must not
exceed the maximum permissible for the motor.
EXAMPLE:
Phase 1
54.0 amp
Phase 2
55.0 amp
Phase 3
60.0 amp
Average:
56.3 amp
% Unbalance = (60 - 56.3) x 100
56.3
= 3.7 x 100 = 6.6%
56.3
WARNING
FAILURE TO GROUND THE UNIT PROPERLY CAN
RESULT IN SERIOUS OR FATAL SHOCK. REFER
TO ELECTRICAL CODE REQUIREMENTS.
Should the unbalance exceed 5%, consult the power
company to improve the voltage balance between the
incoming lines
5. Use a voltmeter to verify the voltage at the starter while
the pump is running. The voltage must be within 10% of
the motor rating, and the maximum variation of any
phase of a 3-phase system from the average should not
exceed 1%.
6. Continue to run the pump until the drawdown of the
water in the well becomes stable. Should the water level
drop to the pump intake to admit air, use one or more of
the following methods to protect installation.
(a) Install additional riser pipe to place pump lower in the
well if possible.
(b) Use a gate valve in the discharge line to throttle the
pump output to suit the yield of the well.
(c) Install floatless liquid level control.
(d) Use a pressure switch with a low water protection
or a separate low-water cutout switch. Neither of
these devices give as reliable protection as a floatless
liquid level control and both require careful application.
(e) Replace the pump with smaller unit to avoid over
pumping the well.
Record the insulation resistance and the running current
for future reference. When the insulation resistance falls
below 10 megohms, check it frequently for further
deterioration and pull the pump when the resistance falls
to 0.5 megohm or below.
When pulling the pump, either coil the cable on a reel or
raise it from the ground to dry. Check the insulation again
when the cable and splices are dry. If the insulation value
between the line and motor casing increases to 50
megohms or more, isolate the fault in the cable or the
splice and make the necessary repairs. However, if the
insulation reading remains low, disconnect the motor from
the cable and check the motor separately. Should the
motor be defective, check the pump end for wear and
obtain a replacement for either the motor alone, or the
pump unit, as necessary.
J. TROUBLESHOOTING
1. Disconnect power unless required for testing.
2. Have electrical testing done by a qualified electrician.
3. Most problems occur above ground. Remove pump
only as a last resort.
When troubleshooting or servicing the pump, use all
precautions for the voltages involved.
WARNING
HAZARDOUS VOLTAGE- CAN SHOCK, BURN
OR EVEN KILL .
Problem
CAUTION
NEVER RUN THE PUMP UNLESS IT IS
COMPLETELY SUBMERGED IN WATER.
The most reliable indication of the condition of a
submersible pump are:
(a) Current drawn by the motor.
(b) Insulation resistance of the installation below ground.
As the pump wears, the motor current increases, until
eventually the overloads trip to protect the motor. The
overload is designed to protect the motor in an emergency
situation, proper care of a submersible installation should
include periodic check-ups to avoid interruptions in the
water supply. Use a megger to check the motor's
insulation resistance every six months.
Call Dealer or Electrician
2. Pump sandlocked
Call Dealer: pull pump and
clean
1. Insufficient well yield: water
level has dropped
Reset pump lower into well
2. Clogged intake screen
Pull pump
Pump fails to
deliver water 3. Air lock in pump
I. OPERATIONAL CHECKUP
Overload
trips
Unit
cycles too
frequently
Restrict flow to yield
Start and stop pump several
times allowing 15 min. between
starts and stops.
4. Leak in discharge
Raise pipe until leak is found
1. Screen or pump partly
plugged
Pull pump and clean
2. Insufficient well yield
Reduced
pump output
Remedy
Check power source: starter
and reset
Check resistance:
cable and motor
Unit fails to
start
H. ACCESSORIES WITH INSTALLATION
RELIEF VALVE
Always install a relief valve if the pump is capable of
developing pressures in the discharge system greater
than the pressure ratings of individual components. The
relief valve must be large enough to handle the pump
output at the relief pressure.
Possible Cause
1. Electrical trouble
Check water level: lower pump
if permissible
3. Worn pump - excessive wear
Replace worn parts
due to abrasives
4. Low voltage
Call Electrician
5. Three-phase unit running
backward
Reverse rotation
1. Worn pump or pump bound
by sand
Pull pump and clean or replace
worn parts
2. Electrical troubles
Call dealer or Electrician
1. Pressure switch out of
adjustment
Readjust to correct setting or
replace
2. Leaks in service line
Locate and correct
3. Check valve leaking
Replace
4. Water logged tank
Check tank for leaks be sure
fittings are functioning properly
Equipment for Submersible Turbine Assembly
*Please see mi2011 STS assembly manual for instructions on how to properly assemble a STS Submersible
Turbine Pump.
The minimum basic hand tools and equipment needed for submersible turbine assembly:
Assembly Fixture Kit 305386901
6 x 6 Collet Hammer 305385101
8 x 6/8 x 8 Collet Hammer 305385102
Allen Wrenches – SAE or Standard (preferably T-handle design)
5/32” is used for sand collar set screws
1/8” is used for motor coupling set screws
3/8” for STS upthrust adjustment
Combination wrench or socket and ratchet set
5/16” for cable guard screws
7/16” for 6” sub turbine bowl bolts
9/16” for 8” sub turbine bowl bolts
1-1/8” for upthrust bolt and lock nut (For 8” STS Assembly)
Flat head or standard large screw driver
Ballpeen hammer
Dow Corning 111 Valve Lubricant & Sealant (food grade grease)
Loctite 243
Fine emery cloth or steel wool for de-burring purposes.
Optional tool available: 305471902 6” STS Bowl Bolt Assembly Tool
Assembly Fixture Kit # 305386901
Note: Kit includes 6x6, 8x8 Assembly Fixture, 8x6 Assembly Plate. Plate Screws and Shaft Bolts.
6x6 and 8x8 Assembly Fixture
Note: Use 3/8-16 UNC -x 4" long bolt to hold shaft for 6” turbine assembly
Use 3/8-16 UNC -x 4 -1/2" long bolt to hold shaft for 8” turbine assembly
5" or 6" Upthrust Spacer
Part # 305472501
.221
Note: An alternative procedure to using the spacer is to back out
the 6" STS upthrust bolt 2 1/4 turns or the 8" STS upthrust bolt 2
1/2 turns, then secure the position by tightening the lock nut.
8" Upthrust Spacer
Part # 305472502
.250
Assembly Fixture Kit # 305386901
Note: Kit includes 6x6, 8x8 Assembly Fixture, 8x6 Assembly Plate. Plate Screws and Shaft Bolts.
8x6 Assembly Plate
Note: Use 3/8-16 UNC -x 4" long bolt to hold shaft for 6” turbine assembly
Use 3/8-16 UNC -x 4 -1/2" long bolt to hold shaft for 8” turbine assembly
Field Installation of the 8x8-inch Coupling
1. Place the motor in a vertical position.
NOTICE:
A motor and pump should always be coupled in a vertical position to ensure correct alignment and prevent any chance of bending or damaging to either shaft.
2. Clean the pump and motor shafts of debris.
3. Check to insure the shafts rotate freely.
4. Generously lubricate the motor shaft splines.
NOTICE:
Use a non-toxic FDA approved waterproof grease – (Mobile FM102, Texaco CYGNU2661, or equivalent.)
5. Install the coupling on the pump.
6. Lightly tighten one of the coupling set screws.
7. Align the pump such that the motor leads will be correctly positioned with the lead notch in the
pump’s mounting flange.
8. Lower the pump so the mounting holes are aligned and the pump’s weight is supported by the
motor face.
9. VERIFY THE PUMP SHAFT WAS LIFTED 1/8” DURING THE PREVIOUS STEP. This is
critical to ensure the impellers are correctly positioned in the pump bowls.
10. Install and tighten the motor and pump mounting bolts.
11. Align the coupling splines with the motor shaft splines and pull the coupling down as far as it
will slide on the pump shaft.
NOTICE:
When the coupling is correctly positioned, only a small amount (~ 1/8”) of the end of the motor
splines will be visible.
12. Apply Loctite 243 and firmly tighten the set screws in the coupling.
INSTALLATION COMPLETE
E631 106089101 Rev. 5 05/14
9255 Coverdale Rd.
Ft. Wayne, IN. 46809
Tel: 260-824-2900
Fax: 260-824-2909
www.franklinwater.com
U.S. LIMITED WARRANTY*
Franklin Electric Co., Inc.
Franklin Electric Co., Inc. warrants its new products to be free of defects in material and workmanship for a period
of 1 year from date of installation or 2 years from date of manufacture, whichever comes first, WHEN installed in clean,
potable water applications. Warranty does not cover applications pumping saltwater or other corrosive liquids. Consult
and adhere to local codes for all applications. Franklin Electric Co., Inc. also provides additional warranty coverage on
specific products as specified herein.
Franklin Electric’s warranty obligation with regard to equipment not of its own manufacture is limited to the warranty
actually extended to Franklin Electric by its suppliers.
This warranty extends only to the original retail purchaser and only during the time in which the original retail purchaser
occupies the site where the product was originally installed.
Requests for service under this warranty shall be made by contacting the installing Franklin Electric dealer (point of
purchase) as soon as possible after the discovery of any alleged defect. Franklin Electric will subsequently take corrective
action as promptly as reasonably possible.
Franklin Electric at its discretion may replace or repair any product that fails under this warranty after inspection by
an authorized company representative or after Franklin Electric has received the product at our factory. Replacement
or repair cannot be made until after the product is inspected. All charges or expenses for freight to and from the factory,
removal and reinstallation of the product, or installation of a replacement product are the responsibility of the purchaser.
THIS WARRANTY SUPERSEDES ANY WARRANTY NOT DATED OR BEARING AN EARLIER DATE. ANY
IMPLIED WARRANTIES WHICH THE PURCHASER MAY HAVE, INCLUDING MERCHANT ABILITY AND FITNESS
FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND BEYOND THE APPLICABLE WARRANTY PERIOD. Some
states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to
you. IN NO EVENT SHALL FRANKLIN ELECTRIC BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above may
not apply to you.
This warranty does not apply to any product which has been subjected to negligence, alteration, accident, abuse,
misuse, improper installation, vandalism, civil disturbances, or acts of God. The only warranties authorized by Franklin
Electric are those set forth herein. Franklin Electric does not authorize other persons to extend any warranties with
respect to its products, nor will Franklin Electric assume liability for any unauthorized warranties made in connection with
the sale of its products.
THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH
MAY VARY FROM STATE TO STATE.
* Contact Franklin Electric Co., Inc. Export Division for International Warranty.