TMR 204EU - JL Supplies

Transcription

TMR 204EU - JL Supplies
MANU-204EU-AC
TMR 204EU
MIC-204EU-AC
Emergency phones for elevators
Immeuble Le Thales A – 1 rue du Gabian - 98000 MONACO
Tel : (377) 97 97 50 00 - Fax : (377) 97 97 50 01
e-mail : micome@micome.com
1- PROGRAMMING OF THE EMERGENCY PHONE
EN
Enter in programming mode
- Dial 0000 on the keypad if the autodialler is power supplied
- Dial 0 + bell at the same time then 000 if the autodialler is line powered
Leave the programming mode
- Dial D
Reset :
- Dial * 5 * D if the autodialler is power supplied
- Dial * + bell at the same time, then 5 * D if the autodialler is line powered
PROGRAM THE NEEDED PARAMETERS
The following parameters should be programmed on all emergency phones connected to
network with double ring.
C391
C381
C6 + value (10 to 19) increases the number of rings in case of double ring.
1- Program the emergency numbers on the push buttons
. Push button in the cabin : A11 – emergency number – confirm with ##
. Push button on the autodialler : A21 – emergency number – confirm with ##
2- Location of the call (EN81-28)
2-1 with the telephone number (rule compliant if only one autodialler on the line)
. no programming necessary
2-2 with identification number of the cabin (rule compliant even if there are up to 4
autodiallers on the line) – Micome software is needed
. C951 (activated)
. C950 (deactivated)
. B21 identification number (4 to 12 digits) – confirm with ##
2-3 with voice location announce
. C932 (announce activated)
. C930 (announce deactivated)
. C97 register the announce – confirm with #
. C98 listen to the recorded message
3- Call acknowledgement and alarm mode
(EN81-28 and EN81-70 if there is an inductive loop) – only if power supplied – Micome
software is needed
. B31 (activated)
. B30 (deactivated)
. A31 call number for transmitting of data – confirm with ##
2
4- Cyclical calls (EN81-28) – only if power supplied
EN
. C403 (cyclical call activated without off-hook)
or C402 (cyclical call activated with off-hook and data exchange if more than one
autodialler is connected to the line) Micome software needed
or C401 (deactivated)
. C41 + time between two cyclical calls in minutes 4320 = 3 days
. A32 telephone number for transmitting of cyclical calls – confirm with ##
5- More than 1 TMR on the same telephone line (up 4 autodiallers)
. C00 (avoids conflicts between events when several autodiallers are connected to the
same line)
. B25 + number of the TMR - B251 is the first autodialler, B253 is the third autodialler
If an incoming call arrives on the telephone line, all autodiallers will answer. Dial the
number of the cabin you want to talk to, the other emergency phones will hang up.
6- Remote monitoring and/or battery default – only if power supplied – Micome
software is needed
. C481 (activated)
. C480 (deactivated)
. A31 telephone number for transmitting of defaults – confirm with ##
7- Communication time (default value : 2 minutes)
. C20 + communication time (1 to 6) : C201 = 1 minutes or C206 = 6 minutes
8- Adjustment of microphone / loudspeaker
8-1 Loudspeaker adjustment (default value : 08)
. C80 + value (01 to 19)
8-2 Microphone sensibility (default value : 0)
. C81 + value (0 to 2) – caution : if the value is 2, there is a big risk of whistle
9- Dialling / redialling
9-1 Pushing time of push button (default value : 1 second)
. C18 + pushing time in seconds (1 to 3 seconds) : C181 = 1 second
9-2 Number of rings before next emergency number (default value : 8)
. C35 + number of rings (01 to 12) : C3508 = 8 rings
9-3 Number of redialling cycles (default value : 2)
If the emergency number doesn’t answer, the autodialler will try 2 times
. C02 + redialling cycles (1 to 9) : C029 = 2 cycles
3
2- CONNECTION SCHEMA
EN
Fixing holes with rawplugs M3
(tapper screws included)
Input alarm
filtering
Input remote
monitoring 2
*
NO
NC
Input remote
monitoring 1
Configuration push
button cabin NO/NC
Loudspeaker
*
Power supply 12Vdc
Output signal inductive
loop (cable is provided
with 2100)
Remote voice RJ45
(cable is provided
with remote voice)
Input remote
monitoring 3
and 4
or output
remote order 1
and 2
Keypad and
push button
engineer
Telephone line RJ11
(3 m cable is provided)
PSTN
PSTN
TMR 204EU
ON TOP OF CABIN
TMR 204EU
ON TOP OF CABIN
REMOTE
VOICE
2013
UNDER CABIN
REMOTE
VOICE
TMR 207EU
IN THE PIT
* - If there are 3 alarm initiation devices with a 2013 under the cabin, connect the 2013 to the TMR and then
to the remote voice in the cabin.
- If there are 3 alarm initiation devices with an item in the pit, connect the remote voice in the cabin to the
TMR on the top of the cabin and the autodialler in the pit directly to the telephone line.
** Concerning the connection of the inductive loop, see the manual of the audioloop.
4