Nova Energy & Automation Imaging Suite Power Systems Nuclear
Transcription
Nova Energy & Automation Imaging Suite Power Systems Nuclear
Nova Energy & Automation Imaging Suite Power Systems Nuclear Camera Main Disconnect Panel PROJECT NAME The Nova Main Disconnect Panel is an integrated Main Circuit Breaker Panel with Emergency Off Accessories and related controls specifically designed to meet the requirements of medical imaging installations. The internal controls provide a safe, low voltage interface between the imaging equipment, control, UPS, and room line voltage. CATALOG NUMBER NEA-43030-5W-UV(120AC)-NM-HCN NOTES The Nova Imaging Suite Power System is a prescribed solution for the power requirements of GE Nuclear Camera 480V Imaging installations. The NEA43030-5W-UV(120AC)-NM-HC/N can be identified on the GE Healthcare Drawings: Sheet E1 Right Column Junction Point Descriptions A Main Disconnect: Equal to GEX640NM25A480V FEATURES: • Integrated design • Utilizes heavy duty Square D Circuit Breaker to handle inrush currents. • Listed to UL508A and cUL to conform to NEC. • Labeled to conform to NFPA99, NFPA-70. • Provides Short Circuit and Overload Protection • Provides differential protection • Internally derived Emergency Off Control Voltage • Neutral Block and Ground Block • Single point main disconnect and termination point • Factory wired to match imaging equipment and tested • Manufactured in the USA • UPS Controls Integrated into Panel The Nova Imaging Suite Power Systems exceed the standard power requirements set forth by the Medical Imaging Equipment design guides (Siemens, Toshiba, Hitachi, GE, and Philips). Optional features include Emergency Off, Shunt Trip, Undervoltage Detection, Fail Safe Energy Storage, Enhanced Short Circuit Current Rating, 100% rated Circuit Breakers, Auto Restart, Earth Leakage Detection, Ground Fault Detection, and Power Quality Monitoring. Figure 1: Photo of completed Nova MDP Panel Table 1: Control Panel Ordering Information Figure 2: Typical One Line Diagram CLASS NEA - VOLTAGE PHASE MAIN CB [1] CURRENT RATING 4 = 480V 3 = 3 POLE 030 = 30 A NEUTRAL - 5W = 3 PHASE, 1 NEUTRAL, 1 GROUND MAIN CB ACCESSORIES UV(120AC) = UNDERVOLTAGE TRIP 120V AC PANEL ACCESSORIES - NM = NUCLEAR CAMERA ACCESSORIES ENCLOSURE DESCRIPTION ENCLOSURE SIZE HC = HINGE NEMA 4 ENCLOSURE N = 16” W X 24” H X 06” D NOVA 1-414-939-NOVA | Fax: 262-364-2279 | Web: www.novaautomation.net | Nova Energy & Automation Imaging Suite Power Systems Main Disconnect Panel SPECIFICATIONS: Item Specification General Performance Application Main Disconnect Panel for Nucleare Camera Medical Imaging Equipment Input Current Rating 480/ 277VAC, 3 Phase 5-Wire: 3 Phase Conductors + Neutral + Ground Or 4 Wire 3 Phase Conductors + Ground 30A As indicated in table 1 Main CB [1] Output Voltage 480/277 VAC, 3 Phase (follows input voltage) Control Voltage Internally derived 24VDC Emergency Off Accessories 120VAC Undervoltage Trip as indicated in table 1 Main CB Accessories Operator Controls Compatible with 120VAC and Low Voltage EPO operator devices Compatible Estop Buttons ESTOP22, 2 NO & 2 NC Contacts Input Voltage Control Details UPS Integral 12VDC control voltage and alarms for GE 20kVA UPS or Eaton 6kVA UPS Rating Grounding Isolated and non isolated Ground Bar Physical Short Circuit Current Protection Dimensions 5W Systems: 35kAIC, (Enhanced SCCR rating optional) 16" W x 24" H x 6" D Weight Enclosure Certification 45 lbs Nema 4 Enclosure. 16 Ga Carbon Steel, all rounded corners, Powder Coated in textured paint code RAL 7035 Certification ETL, cETL Material Usage RoHS compliant; no mercury Environment Indoor use DIMENSIONS: NOVA 1-414-939-NOVA | Fax: 262-364-2279 | Web: www.novaautomation.net |