METALARC® POWERBALL® Ceramic

Transcription

METALARC® POWERBALL® Ceramic
www.sylvania.com
METALARC® POWERBALL® Ceramic
Metal Halide Tubular Single-Ended Lamps
Key Features & Benefits
Advantages of POWERBALL Ceramic Arc Tube Technology
—— Superior white light
—— Excellent CRI, up to 90, yields more
natural colors
—— 20,000 hour rated life and increased
efficacy
—— Lower thermal output than tungsten
halogen lamps having similar light
output
—— Superior color stability over the life
of the lamp
—— Improved lamp-to-lamp color
consistency*
—— UV-Stop technology significantly
reduces UV output and minimizes
discoloration and fading of
materials
—— Pulse start arc tube technology
—— Strong G8.5 bases on TC lamps
allow for more robust handling
—— Compact light sources improve
fixture optics
—— QUICK 60+® System Warranty when
paired with QUICKTRONIC® MH
electronic metal halide ballasts
* Compared to quartz metal halide lamps of similar wattage
New METALARC POWERBALL Ceramic T lamps meet today's color
critical needs with an improved life rating to 20,000 hours and increase
in lumen output.
Compared to conventional quartz metal halide products, SYLVANIA
ceramic arc tube metal halide lamps exhibit less color variation and
higher efficacy. Their high mean lumens, excellent color characteristics
and compact size allow them to be used in a wide variety of applications.
Product Offering
Wattage
39 70 Bulb Shape
T4.5, T6
T4.5, T6
METALARC POWERBALL Ceramic lamps operate on existing ANSI
specified compatible ballasts and on compatible electronic ballasts.
The lamps can be used in appropriate existing fixtures designed for
metal halide lamps of similar wattages and configurations.
To maximize energy savings, system performance and system warranty,
consider operating these lamps on QUICKTRONIC MH electronic metal
halide ballasts.
Application Information
Applications
Application Notes
—— Accent/track lighting
—— Displays
—— Façade lighting
—— Indirect luminaires
—— Landscape luminaires
—— Recessed downlights
—— Studio lighting
1. METALARC POWERBALL Ceramic T4.5 and T6 single-ended products must be operated
in enclosed fixtures capable of containing particles as hot as 1200°C.
HID054R15-LFT 4-15
Ballast Information
Contact your OSRAM SYLVANIA representative or visit www.sylvania.com for a list of compatible
electronic control systems and download the latest Ballast Technology & Specification Guide.
Specification Data
Catalog #
Type
Project
Comments
Prepared by
Product Comparison
New Product improvements versus current product specifications
AverageLamp
Item Ordering
ANSI
Rated
Initial Mean
Efficacy
Number
Abbreviation
Watts
Bulb
Base
Code
Life (hrs.)
Lumens
Lumens
CCT
CRI
(LPW)
Today
64971 MC39TC/U/G8.5/830
39
T4.5
G8.5
C130/E
15,000
3400
2720
3000
82
87
Improved!TBD
MC39TC/U/G8.5/930 39
T4.5 G8.5
C130/E
20,0004200 3360300090108
Today
64974 MC70TC/U/G8.5/930
70
T4.5
G8.5
C139/E
15,000
6300
5040
3000
95
90
Improved!TBD
MC70TC/U/G8.5/930 70
T4.5 G8.5
C139/E
20,0008200 6560300090112
Today
64970 MC39T6/U/G12/830
39
T6
G12
C130/E
15,000
3400
2720
3000
82
87
Improved!TBD
MC39T6/U/G12/830 39
T6
G12
C130/E
20,0004200 3360300090108
Today
64969 MC70T6/U/G12/830
70
T6
G12
C139/E
15,000
7000
5600
3000
87
100
Improved!TBD
MC70T6/U/G12/830 70
T6
G12
C139/E
20,0008200 6560300090112
General Notes:
• Contact your local OSRAM SYLVANIA representative for compatible electronic ballasts.
• All ceramic lamps should be used with 4000V pulse rated socket only.
• No special handling requirements during installation (i.e., gloves not required). Always follow normal safety precautions during installation
Ordering Guide
MC
M=METALARC ®
C=Ceramic
70
Wattage:
39
70
T6 / U
/
Bulb Shape:
Operating T4.5 (TC) position:
T6
Universal
Typical Lumen Maintenance Curve
(with Magnetic Ballasts)
Technical Information
Typical Lumen Maintenance Curve
Typical Mortality Curve
PERCENT SURVIVAL
90
80
70
60
50
40
30
20
10
0
20
40
60
80
100
90
80
70
60
50
40
30
20
10
0
PERCENT OF INITIAL LUM ENS
PERCENT OF INITIAL LUM ENS
100
0
G12/ 930
Base:
9=90+ CRI
G8.5
30=3000K CCT
G12
0
100
10
20
40
30
50
60
70
80
90
100
PERCENT OF RATED LIFE
PERCENT OF RATED LIFE
PERCENT OF INITIAL LUMENS
Lamp 100
Dimensions
90
80
Lamp
70
Shape
TC 60
T6/G12
50
Lamp(A)
Wattage
MOL
39, 70
3.19" (81mm)
39, 70
3.94" (100mm)
(B)
LCL
2.05" (52mm)
2.20" (56mm)
(C)
Bulb Diameter
0.591" (15mm)
0.748" (19mm)
C
C
TC/G8.5
T6 (T7.5)/G12
40
30
A
20
A
10
B
0
0
10
20
30
40
50
60
70
PERCENT OF RATED LIFE
80
90
100
B
100
90
80
70
60
50
40
30
20
10
0
0
Sample Specification
Lamp(s) shall be METALARC ® POWERBALL® Ceramic MC70T6/U/G12/830 lamp(s), and shall be constructed with a spherical shaped ceramic arc-tube with initial lumens of 7000.
Lamp(s) shall have an average rated life of 15,000 hours, CRI of 87, CCT of 3000K and shall exhibit a maximum color shift of ±150K over life. Lamps shall be rated for open fixture use.
Lamps shall be operated on QUICKTRONIC ® MH electronic metal halide ballasts and the system shall be covered by the SYLVANIA QUICK 60+ ® System Warranty.
Related Literature
QUICKTRONIC MH 20W-100W Electronic Metal Halide Systems (Literature Code: ECS054)
QUICKTRONIC QHE MH 20W-39W Super Mini Electronic Metal Halide Systems (Literature Code: ECS124)
Safety Information
WARNING: This lamp can cause serious skin burn and eye inflammation from shortwave ultraviolet radiation if the outer envelope of the lamp is broken
or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Lamps
that will automatically extinguish when the outer envelope is broken or punctured are commercially available.
Americas Headquarters
OSRAM SYLVANIA Inc.
100 Endicott Street
Danvers, MA 01923 USA
Phone 1-800-LIGHTBULB (1-800-544-4828)
www.sylvania.com
SYLVANIA, METALARC and QUICK 60+ are registered trademarks of OSRAM SYLVANIA Inc.
POWERBALL and QUICKTRONIC are registered trademarks of OSRAM GmbH.
Specifications subject to change without notice.
/sylvania
© 2015 OSRAM SYLVANIA
/sylvania