illmod 600 12.02.02 2002 18542 since 1999 fire retardant resin
Transcription
illmod 600 12.02.02 2002 18542 since 1999 fire retardant resin
illmod 600 Product Information Short Description illmod 600 is an impregnated, precompressed foam tape. Since 1965, this tape has proven itself in driving rain resistant joint sealing in aboveground buildings. Since January 11, 1999, illmod 600 complies with all parameters required by DIN 18 542 according to BG1 by the terms of the ift Test Report of January 11, 1999. Consistent high quality is ensured by permanent in-house and independent monitoring. Material Open-cell flexible polyurethane foam impregnated with a flame-retardant artificial resin. Colours ● Anthracite ● Grey Product Advantages ● Independently monitored during driving rain resistance up to 600 Pa (by MPA Bau (Construction), Hannover) ● Open to water vapour diffusion ● Self-adhesive on one side to facilitate installation ● Can be coated with commercially available vinyl emulsion paints ● Meets the RAL-Assembly Requirements Availability On pre-compressed rolls, self-adhesive on one side. illmod 600 Technical Data illmod 600 DIN 4102 52 612 52 615 Building material class Conductivity Resistance to water vapour diffusion Temperature resistance Resistance to plant roots Air permeability of joints Weather resistance Grouping Driving rain resistance 4062 18 055 53 387 18542 18 055 Compatibility with other building materials 52 453 Long-term durability Shelf life Storage temperature Classification B1 (fire-resistant) P-NDS 04-229 λ 10 0.055 W/m · k 100 – 30 °C to + 90 °C meets requirements a 0,1 m3/[h · m · (daPa) n] meets requirements BG1 meets requirements up to 600 Pa for the given operating range, externally monitored by MPA Bau (Construction) Hannover no evidence of corrosion with iron, zinc, steel, galvanised sheet and copper; no harmful interaction with concrete, foam mortar, clay brick, sand-lime brick, hard PVC, plexiglass and wood. Additional materials on request. 10 year functional guarantee * 2 years + 1°C to + 20 °C 01/02 *according to specific conditions provided by the manufacturer (available on request) Dimensions/Sizes Order No. Joint depth/Joint width in mm 8/ 2 10/ 2 15/ 2 20/ 2 8/ 10/ 15/ 20/ illmod 600 Operating range* Joint width in mm 2 3 3 3 3 3 12/3 – 7 15/3 – 7 20/3 – 7 3– 7 Order No. Joint depth/Joint width in mm 15/ 5 – 10 20/ 5 – 10 Operating range* Joint width in mm 5 – 10 Order No. Joint depth/Joint width in mm 30/13 – 24 40/13 – 24 Operating range* Joint width in mm 13 – 24 15/ 7 – 12 20/ 7 – 12 7 – 12 35/17 – 32 40/17 – 32 17 – 32 20/ 8 – 15 30/ 8 – 15 8 – 15 40/24 – 40 50/24 – 40 24 – 40 20/10 – 18 25/10 – 18 30/10 – 18 10 – 18 * Movement of building components and changes in length related to temperature should be taken into account in measuring specific joint widths. Application illmod 600 Tools Fitting requires a tape measure, a spatula, scissors or a knife and possibly a wooden wedge. Application ● Select the correct tape dimension (see table) after determining the width of the joint. ● Cut off the beginning (or end) of the tape that is too compressed. ● While cutting the tape to the appropriate length, add 1 cm per metre. ● Start application from the bottom up in vertical joints. Butt-joint the ends of the tape. ● The sides of the joint should be parallel (maximum deviation 3 deg.). Furthermore, both sides must be cleaned of any rough remains like mortar and dirt. ● For aesthetic reasons, the tape should be fitted 1 – 2 mm from the front edge of the joint. ● The self-adhesive side of the tape, which facilitates the application, can be neutralised by wet joints. In this case, fix illmod 600 with wedges during the expansion time (Fig. 2). ● Please check the specific compatibility with paints, coatings, sealants and natural stone. Product Range Joint Sealant Tapes PU-Foams Butyl Tapes Sealant Foils Special Products Accessories Fig. 1: Take application in window corners Fig. 2: Butt-joint in solid type construction Fig. 3: Butt-joint for window installation Fig. 4: Cross-joint Attention: Avoid tape contact with solvents or corrosive chemicals. Application Tips for Cross Joints ● Pay attention to a flush fit of the horizontally or vertically butted surfaces in a cross-joint (Fig. 4). Application Tips for Window Installation ● Do not apply illmod 600 around the corner of the window frame (Fig. 1). ● The tape must be butt-jointed (Figs. 1 & 3). Application Tips for Solid Type Construction ● Do not compress the tape excessively during the assembly of prefabricated building parts. ● The use of a water repellent on the sides of the joint of very porous surfaces is recommended before mounting illmod 600. ● Take care that the adhesive side of the tape is applied on the surface of horizontal applications. Service illbruck’s application technology is always available to support and advise you on request. Additional information The afore-mentioned information only contains general recommendations. Due to the many different conditions in which applications take place, on which we can exert no influence, and the multiplicity of many different materials, extensive preliminary testing is recommended to examine the characteristics of the material for each specific application. Manufacturer’s data as of 01/02. Subject to technical modifications. illbruck Bau-Technik GmbH · Burscheider Straße 454 · D-51381 Leverkusen · Tel. + 49 (0) 21 71- 391-0 · Fax + 49 (0) 21 71- 391-586 www.illbruck-sealantsystems.com · e-mail: sealantsystems@illbruck.com