APPLICATION INSTRUCTIONS
Transcription
APPLICATION INSTRUCTIONS
APPLICATION INSTRUCTIONS GENERAL INFORMATION: MiraTEC Treated Exterior Composite Prefinished Trim is 16'' O.C. ) or ater m an engineered wood composite trim designed for use in both exterior and interior applications where a Rafter non-structural smooth or wood grain textured blemish-free trim product is desired. MiraTEC prefinished trim resists moisture, rot and termites. MiraTEC alberga el ESR-3043 del Servicio de Evaluación ICC. Patented Sub-fascia is recommended in regions of high humidity or extreme humidity changes. CUTTING: Rafter 16'' O.C. Sub-fascia is recommended in regions of high humidity or extreme humidity changes. Fascia Use a fine-tooth hand saw or power saw with a combination blade. Cut into the painted face of the Rafter material. Carbide-tipped blades are recommended. Fascia 16'' O.C. FASTENING REQUIREMENTS: 24" max Sub-fascia is recommended Rafter Fascia Application in regions of MiraTEC prefinished trim is a non-structural decorative trim product and should not be used high humidity or extreme where structural lumber properties are required. MiraTEC prefinished trim is designed to be Rafter humidity changes. Fascia applied to structural framing, sheathing and other materials. 16'' O.C. Siding 16˝ O.C. Sub-fascia is Continuous recommended horizontal 16'' O.C. in regions of flashing high withhumidity drip & 2˝or(min.) extreme overlapshumidity changes. & joints Fascia Siding Window or door head casing, water table or other horizontal trim Sub-fascia is recommended in regions of high humidity or extreme humidity changes. Continuous horizontal flashing with max drip & 2˝24" (min.) overlaps & joints Fascia Application 24" max Fascia Application Sub-fascia is recommended in regions of Siding 24" max high humidity Fascia Application or extreme Continuous humidity changes. horizontal Rafter 16˝ O.C. flashing with drip & 2˝ (min.) overlaps 16˝ O.C. Fascia & joints Fascia Window or door head casing, water table or other 24" max horizontal trim Fascia Application 24" max Fascia Application Fascia Application Window or edge. door *Note: Nail at least 1/2˝ from the Do not nail into the edges of MiraTEC prefinished trim. For 4/4 and 5/4 fascia and head casing, water soffit applications, MiraTEC prefinished trim can be fastened directly to the rafter ends, double nailed a minimum of 24˝ table or other CORRECT trim and vertical applications, double 16˝ nail O.C. 16˝ on center, falling on the studs. on center. ForSiding all otherhorizontal horizontal CORRECT Siding 16˝ O.C. Gap 1/8'' 16˝ O.C. Framing Continuous Fasten MiraTEC prefinished trim from Seal Joint horizontal Continuous one flashing end towith the other end. horizontal drip & 2˝ (min.) 1/2'' min INCORRECT overlaps CORRECT flashing with & joints Window or door head casing, water table or other INCORRECT horizontal trim DO NOT nail toward the center from both ends. INCORRECT drip & 2˝ (min.) 16'' max Gap 1/8'' Double nail on both sides of butt joint overlaps & joints Framing Gap 1/8'' Seal Joint 1/2'' min 16'' max Framing Double nail on both sides of butt joint Seal Joint 1/2'' min Window or door 16'' max Double nail on both sides of butt joint head casing, water All joints must fall over a framing member. MiraTEC prefinished trim can be mitered, scarfed, or beveled as required. For runs less than 30 feet table or other in length, butt joints should lightly touch.horizontal For runs overtrim 30 feet in length, space all butt and scarf joints 1/8˝ apart and apply sealant into the full BUTT JOINTS: depth of the 1/8˝ joint. Double nail all joints on both sides as noted in the diagram. CORRECT When mitering for column wraps or corner boards, JELD-WEN, inc. recommends gluing the edges of the trim to maintain a tight joint. Use a Framing 1/8'' quality exterior grade yellow carpenters glue or highGap quality polyurethane adhesive. Lightly ease the edge of the finished corner with 220 grit Seal Joint sand paper for best paint adhesion. INCORRECT Gap 1/8'' CORRECT Framing Seal Joint 1/2'' min 16'' max Double nail on both sides of butt joint Gap 1/8'' 1/2'' min 16'' max INCORRECT Double nail on both sides of butt joint Framing Glue Seal Mitered Joint Edges 1/2'' min 16'' max Double nail on both sides of butt joint FASTENERS: Always use fasteners appropriate to the style of construction where the prefinished trim is installed. Fasteners must be equal or better in performance (such as nail withdrawal, bending strength and corrosion resistance) to 6d or 8d 16 gauge finish nails or headed nails, long enough to penetrate 1 1/4˝ into structural wood studs or studs and structural sheathing material. Use nails with corrosive resistance equivalent to hot dipped galvanized nails. For buildings utilizing steel studs, use ET&F fasteners: AST-075 for 4/4 MiraTEC and AST-100 for 5/4 MiraTEC. For installations near oceans, large bodies of water or in high humidity climates, JELD-WEN, inc. recommends using stainless steel fasteners on MiraTEC prefinished trim. For these installations, do not use electro-galvanized fasteners, due to poor long term rust resistance. CONDITION Power or pneumatic nailing systems may be used. Visit www.miratectrim.com for infor16'' O.C. is mation on air pressure settings on a variety of pneumatic nailers. Tapered orSub-fascia bugle head fasteners are permitted when the heads are properly sealed from moisture.recommended Visible fiber in regions of high humidity or extreme putty specifihumidity changes. Nail heads, or any other dents, can be filled with exterior grade spackling cally designed for filling nail holes. Allow putty to dry, sand smooth with 100 grit sandpaper and spot prime before painting. Over time, spackling putty may need to be replaced or touched up. Use a nail that is appropriate to the style of construction. Do not use staples, braids, or t-nails CONDITION Snug OK Flush OK Rafter Counter sunk 1/16˝ - 1/8˝ Paint Exterior putty Fascia Counter sunk more than 1/8˝ Exterior putty & add nail 24" max Fascia Application FLASHING AND MOISTURE CONTROL: Siding Continuous horizontal flashing with drip & 2˝ (min.) overlaps & joints Window or door head casing, water table or other horizontal trim The structure on which MiraTEC prefinished trim is applied should be well ventilated and dry. Do not apply MiraTEC prefinished trim over wet sheathing, or any closer than 6˝ to finished grade or final landscaping. As with all wood products, 16˝ O.C. MiraTEC prefinished trim should not come in direct contact with masonry or concrete. At foundations or exterior brick veneer, the product should be separated from the masonry by metal flashing, polyethylene film, 30 lb. felt or a 1/4˝ to 1/2˝ air space using masonry standoffs. In all applications, MiraTEC prefinished trim should not be allowed to stand in water. Seal the trim applications to prevent water intrusion. Do not allow water to stand on or leak behind any MiraTEC prefinished trim. MiraTEC prefinished trim used in a horizontal application, including window and door headers, must be properly flashed in accordance with the siding manufacturers’, window manufacturers’, or door manufacturers’ application requirements and local building codes. ADHESIVES: Glues or adhesives can be used on MiraTEC prefinished trim such as on mitered joints for outside corners or column wraps. Use a high quality exterior grade yellow carpenters glue or a high quality polyurethane adhesive. SEALANT: CORRECT Framing Gapabuts 1/8'' siding, windows, doors Sealant is required at butt joints and where MiraTEC prefinished trim or other materials. Use only exteSeal Joint to the manufacturer’s written rior quality sealant that remains flexible over time. Do not use hard-setting caulk. Apply caulk according instructions. JELD-WEN, inc. recommends caulks and sealants that meet ASTM C920. Do not use Bondo® or similar hard setting fillers or putties on MiraTEC prefinished trim. They will crack over time due to the natural expansion and contraction of the trim. INCORRECT 1/2'' min 16'' max Double nail on both sides of butt joint MiraTEC trim SPECIFIC APPLICATIONS Flashing For applications near rooflines, such as dormer and chimneys, the trim should be installed with a minimum of 1˝ clearance between the 1/2'' Gap Between Trim and Flashing roofing and the bottom edge of MiraTEC prefinished trim. At the junction of the roofing material and vertical surfaces, flashing is required per the roofing manufacturers’ application requirements and local building codes. When facing the skirt boards on deck, properly flash the top edge to prevent water from getting behind the trim. As a substitute for flashing, use 1/2˝ standoffs to provide a space behind the backside of the trim and the deck skirt board. MiraTEC trim 1˝ gap between the shingles and trim Flashing Flashing MiraTEC MiraTEC Properly flash and space at least 1/2˝ from any concrete flatwork (such as porches, patios, or driveways) or horizontal brick ledge. MiraTEC trim Flashing MiraTEC 1/2˝ Space Flashing MiraTEC Decorative Shutters 24˝ max. spacing MiraTEC prefinished trim can be used to make decorative shutters. The shutter must be fastened to the home a minimum of 24˝ on center around the perimeter of the shutter as shown in the illustration. Working shutters will not be covered under the MiraTEC warranty due to the inability to provide adequate fastening on the non hinge side of the shutter. 1/4˝ Clearance MiraTEC When vertical trim meets flashing at the top of trim or siding, provide a 1/4˝ clearance from the bottom of the trim to the top of the flashing. SURFACE PREPARATION: The surface to be painted must be free of dust, dirt, mildew and other foreign materials before painting. Wash with water and a mild detergent to remove dust and dirt. Allow the surface to dry before painting. If mildew is present, contact a paint supply store for recommended methods of removing and controlling mildew. MiraTEC TOUCH UP AND PAINTING: 1/2˝ Space MiraTEC prefinished trim is manufactured from wood, and all exposed surfaces must be primed and/or painted according to the following procedures: 1. CUT EDGES AND ENDS: All exposed cut edges and ends must be primed prior to or within 30 days of installation using a high quality exterior primer recommended by the manufacturer for use on composite wood. If these edges/ends will be exposed to the weather and will be visible, they must be topcoated using touch up paint. Any surface damages can also be covered up with touch up paint. 2. TOUCH UP PROCEDURE: Follow all touch-up procedures as defined by the prefinisher. This includes guidelines for surface preparation, temperature requirements, application tools, etc. 5/16'' max depth 5/16'' max depth 5/16'' max depth 5/16'' max depth Patented MACHINING: MiraTEC prefinished trim can be grooved or machined to produce a variety of decorative applications. The machined profile should not compromise the physical integrity of the board or induce cracking or splitting of the product. Routed or grooved MiraTEC prefinished trim should not have any flat surfaces where water can accumulate. Maintain an angle of at least 100 degrees from the vertical to provide positive drainage and to prevent moisture from standing on the surface. Re-prime all machined areas with a high quality exterior oil or acrylic latex primer formulated for composite wood. JELD-WEN, inc. recommends using an oil-based primer. STORAGE: 5/16'' max depth 5/16'' max depth Examples of machining Cover when stored outside. Keep MiraTEC prefinished trim off the ground and dry. Excessive moisture pickup from improper storage may affect the performance of MiraTEC prefinished trim. Do not stack material in excess of 3 units high. Tarp to cover MiraTEC For job site storage, the material should be placed on stringers and covered, preferably on concrete, asphalt, or similar surface. For all other instances, a tarp should be placed over the ground cover under the stringers, with the material still under cover. MiraTEC trim TYPICAL TRIM USES: Ground tarp MiraTEC prefnished trim can be used in a variety of applications as noted below. 7 2 1 3 8 5 6 6 9 10 4 1 Soffit 2 Frieze board 3 Fascia 4 Belly band or band board 5 Window trim 6 Corner board 7 Rake board or shingle mold 8 Architectural porch detail 9 Column wrap 10 Fluted door casing IMPORTANTE: Lea y comprenda todas las instrucciones de aplicación antes de instalar el material. Las declaraciones expresadas en este boletín técnico son recomendaciones para la aplicación de los productos como se detalla e ilustra conforme a condiciones normales de instalación. JELD-WEN, inc. es un fabricante de materiales de construcción. No ejerce la arquitectura ni la ingeniería. Las recomendaciones otorgadas en este boletín representan el mejor criterio de JELD-WEN, inc. Basado en su experiencia hasta la fecha con aplicaciones normales. Estas instrucciones complementan las prácticas de construcción estándar y los requisitos del código de construcción; no se deben considerar exclusivas o excluyentes de estas prácticas y requisitos. A menos que se obtenga una aprobación escrita anteriormente por parte del Departamento de Rendimiento del Producto de JELD-WEN, inc., PO Box 311, Towanda, PA 188-48, cualquier desviación de estos procedimientos recomendados quedará a exclusivo riesgo de los instaladores. Estas instrucciones de aplicación constituyen los requisitos mínimos para el almacenamiento, la aplicación y el acabado de los productos de molduras fabricados por JELD-WEN, inc. En donde los requisitos o estándares del código de construcción sean más restrictivos, se deben seguir las regulaciones aplicables. Consulte a su representante local o al Departamento de Rendimiento del Producto por las condiciones que no estén cubiertas por este boletín. Todos los planos se muestran únicamente a título informativo y no están a escala. El diseño adecuado y el apuntalamiento de las paredes, así como el cumplimiento de estas instrucciones de aplicación, quedan bajo la responsabilidad del arquitecto, constructor, aplicador o pintor. 1.800.255.0785 miratectrim.com R 20827 Class C Fire Rating Flame Spread 120 Smoke Developed 90 © 2013 JELD-WEN, inc. Todos los derechos reservados. Todas las marcas comerciales y las marcas de servicio (registradas o sin registrar) que aparecen son propiedad de JELD-WEN, inc o sus afiliadas o cuentan con la licencia correspondiente. 117 1/14