File
Transcription
File
CENTER WALL W/ WINDOW MULLION A 225 226 A 223 CENTER WALL W/ WINDOW MULLION A 220 A D31 CENTER WALL W/ WINDOW MULLION 218 219 D34 D35 D36 D27 229 210 STD. WATER FOUNTAIN ( P-3) NO WORK IN THIS AREA 206 CAP PLUMBING BEHIND WALL & REPAIR WALL. D03 D38 A NO WORK IN THIS AREA EXCEPT FOR NEW CASED OPENING AS NOTED. A RELOCATE WATER FOUNTAINS TO HERE. 212 D04 D44 D43 D42 NEW 3'W. x 7'H. CASED OPENING. LOCATE BASED ON EXISTING SYSTEMS FURNITURE AND AWAY FROM DOOR D04 AS POSSIBLE. EXISTING 1-HR FIRE RATED CORRIDOR TO REMAIN D41 D39 216 SEVENTH & FRANKLIN BUILDING 701 EAST FRANKLIN STREET SUITE 1115 RICHMOND, VIRGINIA 23219-2510 ( 804) 783-9800 ( 804) 783-9801 FAX AIS.AIS@VERIZON.NET 2'-0" PROVIDE 30"x48" ACCESSIBLE CLEARANCE @HANDICAP WATER FOUNTAIN ( P-2) . 221 224 207 3'-6" D29 228 202 D02 D37 215 D28 208 201 NEW PLAM WALL & BASE CABINETS & NEW SINK ( P-1) -SEE DETAILS 1/A4. 222 D30 209 213 D01 A ALIGN 227 200 214 A D33 WALL HEIGHT TO BE EXTENDED FOR GPDW CEILING IN 213. ALIGN W/ EDGE OF MULLION A A D32 CENTER WALL W/ WINDOW MULLION 211 7'-1" A CENTER WALL W/ WINDOW MULLION D40 230 252 217 D26 D09 TENANT MODIFICATIONS FOR 204 231 203 251 232 NO WORK IN THIS AREA 243 242 D18 D14 D17 241 239 245 D05 D11 NO WORK IN THIS AREA EXCEPT FOR NEW DOOR. EXISTING 1-HR FIRE RATED CORRIDOR TO REMAIN D16 D13 246 244 5211 W. BROAD STREET HENRICO, VIRGINIA 249 248 D15 EXISTING 1-HR FIRE RATED CORRIDOR TO REMAIN 233 S U ITE 200 D10 D25 D24 LU MBER LIQUIDATORS 205 D12 247 D19 D08 D23 NO WORK IN THIS AREA D06A 12'-11" 234 D20 A 18'-8" 236 A 237 D21 NO WORK IN THIS AREA EXCEPT FOR NEW DOOR. D07 238 ER C 235 250 D06B TI C T 240 D22 FIE I D A RCH TE SCALE: 1/8" = 1'-0" PROJECT NO: 2418.02 PARTITION PLAN SCALE: 1/8" = 1'-0" P ARTITION LEG END: NOTE: CONTRACTOR TO VERIFY EXISTING WALLS AND MODIFY AS NECESSARY. EXISTING WALLS TO BE REMOVED. EXISTING WALLS TO REMAIN. A NEW BLDG. STD. FULL HEIGHT WALLS TO UNDERSIDE OF ACOUSTICAL CEILING OR GPDW CEILING U.N.O.. 1/2" GPDW ON BOTH SIDES OF 3 5/8" METAL STUDS @ 24" O.C. W/ 3" ACOUSTICAL INSULATION BETWEEN. CONTRACTOR TO PROVIDE WALL BRACING USING METAL STUD ANGLE BRACING SPACED @ 8' O.C. MAX, ALTERNATING SIDES & ATTACHED USING PARTITION CLIPS AT SUSPENDED CEILING CONNECTION AND ANCHORED TO BUILDING STRUCTURE ABOVE. EXISTING DOOR TO BE REMOVED. REFERENCE NORTH DEMOLITIO N NO TES: 1. CONTRACTOR TO REMOVAL ALL WALLS AS NOTED BY DOUBLE DASHED LINES INCLUDING REMOVAL OF ALL DOORS, FRAMES, AND ALL ELECTRICAL OUTLETS/COMMUNICATION OUTLETS IN DEMOLISHED WALLS & ALL OTHER SUSPENDED CEILING REWORK AND OTHER ITEMS AS INDICATED ON PLANS FOR COMPLETION OF NEW CONSTRUCTION WORK. 2. REMOVE LIGHT FIXTURES, AND OTHER ITEMS AS NOTED AND AS NEEDED FOR THE INTENT OF THE DRAWINGS. COORDINATE ALL DEMOLITION WORK WITH TENANT'S NEEDS AND DIRECTIONS. 3. CONTRACTOR TO REMOVE ALL EXISTING CARPET, VINYL COMPOSITION TILE, VINYL BASE IN AREA OF WORK. SEE SCOPE OF NEW WORK. NEW C O NS TRU C TION NOTES : 1. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. IF DIFFERENT CONDITIONS EXIST, CONTRACTOR SHALL NOTIFY ARCHITECT BEFORE COMMENCING WORK. 2. SEE PARTITION/DOOR LEGEND FOR GENERAL INTENDED CONSTRUCTION WORK. WORK SHALL CONSIST OF ENTIRE CONSTRUCTION WORK AS DETAILED WITH THESE CONSTRUCTION DOCUMENTS UNLESS OTHERWISE AMENDED IN WRITING BY THE ARCHITECT. 3. DIMENSIONS TAKE PRECENDENCE OVER SCALE ON CONSTRUCTION DOCUMENTS. DIMENSIONS ARE TAKEN TO THE FACE OF PARTITIONS UNLESS OTHERWISE NOTED. 4. ALL CONSTRUCTION AND TENANT IMPROVEMENTS SHALL BE IN STRICT ACCORDANCE WITH THE CURRENT APPROVED EDITIONS OF THE UNIFORM STATEWIDE BUILDING CODE; AND ANY AMENDMENTS REQUIRED BY THE LOCAL JURISDICTION; AND APPROVED BY THE LOCAL BUILDING INSPECTION OFFICE. EXISTING DOOR TO REMAIN. ( SEE DOOR SCHEDULE) 5. SEE DOOR SCHEDULE & NOTES. - SEE DOOR SCHEDULE AND NOTES. NEW BLDG STD. F.R. DOOR ( 3'0"W. ) TO BE INSTALLED WITH BLDG STD. LEVER HARDWARE. ( SEE DOOR SCHEDULE) 6. CONTRACTOR TO FURNISH AND INSTALL ALL INTERIOR FINISHES IN ALL NEW AREAS OF WORK. SEE FINISH NOTES FOR ORDERING INFORMATION. SEE FINISH AND ROOM SCHEDULES AND NOTES. 7. ALL ELECTRICAL WORK AND COMMUNICATION OUTLETS & WIREWAYS SHALL BE PERFORMED BY THE CONTRACTOR. COMMUNICATION WIRING AND FINAL TERMINATIONS SHALL BE PROVIDED BY THE TENANT'S VENDOR. ANY EXISTING COMMUNICATION WIRING NOT TO BE RE-USED SHALL BE REMOVED FROM SPACE INCLUDING ABOVE CEILING SPACES. COORDINATE WIRING DEMOLITION WITH NEW TENANT'S VENDOR PRIOR TO REMOVAL. 8. CONTRACTOR TO INSTALL NEW PLASTIC LAMINATE WALL & BASE CABINETS AS INDICATED. 9. CONTRACTOR TO MODIFY EXISTING BLDG. STANDARD MECHANICAL HVAC SYSTEMS TO PROVIDE UNIFORM COVERAGE AND DISTRIBUTION IN ALL SPACES AND AS REQUIRED BY CODE. CONTRACTOR TO EXTEND EXISTING DUCTWORK AND INSTALL NEW RETURN AIR AND SUPPLY AIR GRILLES AS REQUIRED DUE TO WALL CHANGES IN THE SPACE. 10. SEE REFLECTED CEILING WORK. ALL FIXTURES, DIFFUSERS, OUTLETS, AND OTHER CEILING MOUNTED DEVICES SHALL BE INSTALLED AS NOTED. 11. CONTRACTOR TO FABRICATE NEW OCCUPANCY SIGNS WITH PERMANENT SIGNAGE ( ENGRAVED AND/OR VINYL LETTERS) AND INSTALL ADJACENT TO EACH ENTRY DOOR ( APPROX 12"x12") FOR CLASSROOMS & ASSEMBLY AREAS 224, 231, 237, 240-250, & 251 INDICATING MAXIMUM NUMBER OF PERSONS FOR EACH SPACE. SEE BUILDING CODE INFORMATION FOR EACH MAXIMUM OCCUPANCY. B UILDING CO DE INFORMATION: BUILDING CODE: VA. REHABILITATION CODE - LEVEL 2 ALTERATION ICC 2012 W/ VA. STATE AMENDMENTS) USE GROUP CLASSIFICATION - B BUSINESS TYPE OF CONSTRUCTION - IIB FIRE PROTECTION: NON-SPRINKLERED REQUIRED FIRE SEPARATION: 0 HR. - FLOOR/CEILING 2 HR. - FIRE STAIRS - TWO-STORY 2 HR. - SHAFTS - TWO-STORY 1 HR. - CORRIDORS( SERVES >30) 0 HR. - TENANT SEPARATION EGRESS- P RO J EC T C ONTACTS : TENANT CONTACT: JOE MACCARONE LUMBER LIQUIDATORS - DIR. OF CONST. 5211 W. BROAD ST, SUITE 200 RICHMOND, VIRGINIA 23230 ( 757) 778-9672 CONTRACTOR: CORINNA GROGAN / JOHN GENTRY DOMINION CONSTRUCTION PARTNERS 1840 WEST BROAD STREET, SUITE 300 RICHMOND, VIRGINIA 23220 ( 804) 249-2600 ( OFFICE) CGROGAN@DCPGC.COM JGENTRY@DCPGC.COM < 75' MAX. COMMON PATH OF EGRESS < 200' MAX. EXIT ACCESS TRAVEL DISTANCE BUSINESS OCCUPANCY LOAD ( NEW & EXISTING TENANT SPACE) : NEW 14,600 SF/100 SF ( B-USE) =146 PERSONS EXISTING 5615 SF/100 SF ( B-USE) = 57 PERSONS CONF. RM./ASSEMBLY OCCUPANCY USE: CONF. RM. 224: 350 SF/20 SF ( TABLE/CHAIRS) = 18 PERSONS CONF. RM. 231: 385 SF/20 SF ( TABLE/CHAIRS) = 20 PERSONS CONF. RM. 237: 200 SF/20 SF ( TABLE/CHAIRS ) = 10 PERSONS CONF. RM./ASSEMBLY 240 & 250 COMBINED: 1150 SF/7 SF ( CHAIRS ) = 165 PERSONS CONF. RM. 251: 590 SF/20 SF ( TABLE/CHAIRS) = 40 PERSONS AREA OF WORK BLDG. OWNER CONTACT: TERRY COOPER BERNSTEIN ENTERPRISES 5206 MARKEL DRIVE SUITE 306 RICHMOND, VIRGINIA 23230 ( 804) 288-1232 > 50 PERSONS ( W/ 2 MEANS OF EGRESS) FLOOR LOADS: 75 PSF ( LIVE LOAD) DATE: 24 MARCH 2015 ARCHITECT: RICHARD COMESS, AIA ARCHITECTURAL & INTERIOR SERVICES 701 E. FRANKLIN ST, SUITE 1115 RICHMOND, VIRGINIA 23219 ( 804) 783-9800 ( OFFICE) AIS.AIS@VERIZON.NET 5211 W. BROAD ST. 1 KEY P LAN REFERENCE NORTH C ONS TRU CTION P LAN SHEET: A1 OF 2 N N 225 223 N N N N 214 220 219 218 N N N N S S N S S N 210 S 215 SEVENTH & FRANKLIN BUILDING 701 EAST FRANKLIN STREET SUITE 1115 RICHMOND, VIRGINIA 23219-2510 ( 804) 783-9800 ( 804) 783-9801 FAX AIS.AIS@VERIZON.NET 207 206 EM EM 221 229 212 224 EM EM 228 201 N N 222 227 202 208 EXTEND EXIST. CEILING TO MATCH EXIST. GPDW. CLG. S S 209 213 N N N 200 EM EM EM 211 216 230 252 217 EM 226 N EM N TENANT MODIFICATIONS FOR EM N 231 204 N 203 251 LU MBER LIQUIDATORS N EM N 232 EM S U ITE 200 EM 5211 W. BROAD STREET HENRICO, VIRGINIA 242 243 248 249 205 EM EM 241 233 239 246 EM 247 EM EM N 236 EM S 250 237 ER T C S N N C T N 240 EM EM N 235 244 EM EM EM 234 EM 245 IF 238 I ED A RCH I TE SCALE: 1/8" = 1'-0" REFLEC TED C EILING PLAN DATE: 24 MARCH 2015 SCALE: 1/8" = 1'-0" REFERENCE NORTH C EILING P LAN LEGEND: LIG HT F IXTURES VERIFY ALL EXISTING CONDITIONS. NEW AND/OR EXISTING 2'x4' RECESSED/SURFACE FIXTURE TO MATCH BLDG. STD. FIXTURES NOTED "N" INDICATES NEW LIGHT FIXTURE AND/OR LOCATION. CONTRACTOR TO VERIFY COUNTS & ADD NEW FIXTURES AS REQUIRED. S WALL SWITCH - BLDG. STD. - 48" AF CONTROLS LIGHT FIXTURE( S) IN SAME SPACE UNLESS OTHERWISE NOTED. PROVIDE MOTION SENSOR SWITCHING OPTION. AREA OF WORK HVAC LEGEND: CONTRACTOR TO RE-USE EXISTING CEILING SUPPLY & RETURN GRILLES AND MODIFY AND EXTEND DUCTWORK AND GRILLE LOCATIONS TO PROVIDE UNIFORM AIR DISTRIBUTION TO ALL SPACES. T EMERG ENC Y & EXIT FIXTURES EM NEW EMERGENCY LIGHT FIXTURE ( EITHER WALL AND/OR CEILING MOUNTED TIED INTO THE BUILDING EMERGENCY CIRCUIT AS REQUIRED TO PROVIDE 1 FOOTCANDLE IN EGRESS EXITWAY PATH. REPLACE ALL EXIST. FIXTURES W/ NEW LED EMERGENCY FIXTURES. SEE ELECTRICAL/COMMUNICATION PLAN - DWG. A3 FOR REQUIRED PATH OF EGRESS. FIXTURE SPACING MAY DIFFER TO INDICATED FIXTURE SPACING BASED ON FIXTURE TYPE. 1. CONTRACTOR TO REWORK EXISTING CEILING GRID, CEILING TILES, LIGHT FIXTURE PLACEMENT AND SUPPLY/RETURN AIR DUCTWORK AS REQUIRED DUE TO NEW WALL CHANGES AND TO PROVIDE UNIFORM COVERAGE TO ALL SPACES. ALL REWORKED CEILINGS GRIDS, ACOUSTICAL CEILING TILES AND DRYWALL CEILINGS SHALL BE CLEAN AND PROVIDE UNIFORM AND NEW-LIKE APPEARANCE IN ALL SPACES. ALL EXISTING LIGHT FIXTURES SHALL BE CLEANED AND RELAMPED WITH( 4100 K. LAMPS) U.N.O. AND NEW LIGHT FIXTURES SHALL MATCH TO EXISTING. 2. MODIFY EXISTING BLDG. STANDARD MECHANICAL HVAC TO PROVIDE UNIFORM COVERAGE AND DISTRIBUTION AS REQUIRED BY CODE. ALL EXISTING AIR DIFFUSERS AND/OR RETURN AIR GRILLES SHALL BE CLEANED. CONTRACTOR TO RELOCATE THERMOSTAT TO PROVIDE BALANCED HVAC TO ALL SPACES. NEW THERMOSTAT LOCATION TO BE LOCATED BY HVAC CONTRACTOR. NOT ALL LOCATIONS SHOWN ON PLANS WITH CONTRACTOR TO VERIFY. SEE ELECTRICAL/ COMMUNICATION PLANS FOR INDICATED LOCATIONS. P ATH OF EGRES S NEW EXIT SIGN - BUILDING STANDARD EXIT SIGN. CEILING MOUNTED. PROVIDE NEW LED EXIT SIGNS W/ EMERGENCY BATTERY AS INDICATED FOR NEW FIXTURES. REFLEC TED C EILING NOTES : PATH OF EGRESS SHOWN BY DASHED LINE. SEE DWG A3 FOR PATHWAY AND DIRECTION. 5211 W. BROAD ST. 1 PROJECT NO: 2418.02 KEY P LAN REFERENCE NORTH REF LECTED C EILING PLAN SHEET: A2 OF 4 COORDINATE OUTLET LOCATIONS W/ CASEWORK - SEE ELEVATIONS. 200 d +46"AF 225 226 223 220 218 219 214 213 d +30"AF gfi& d +46"AF 209 202 208 201 gfi& d +46"AF 222 227 PP PP d d FOR PTR. 228 229 212 221 224 206 207 210 215 SEVENTH & FRANKLIN BUILDING 701 EAST FRANKLIN STREET SUITE 1115 RICHMOND, VIRGINIA 23219-2510 ( 804) 783-9800 ( 804) 783-9801 FAX AIS.AIS@VERIZON.NET 216 230 PP 211 252 217 PP PP PP d FOR PTR. 232 TENANT MODIFICATIONS FOR 204 d FOR PTR. PP 231 203 251 PP LU MBER LIQUIDATORS PP S U ITE 200 3'-8" MIN. PP 242 243 248 5211 W. BROAD STREET HENRICO, VIRGINIA 249 PP 245 PP 205 COPIER 233 239 d PTR. d 241 246 244 247 PP 234 240 PP 237 ER T C T C 235 236 250 IF 238 I ED ARCH I TE SCALE: 1/8" = 1'-0" SCALE: 1/8" = 1'-0" DATE: 24 MARCH 2015 ARROWS INDICATE ACCESSIBLE PATH OF EGRESS IN SPACE. VCC - SECTION 1007 REFERENCE NORTH AREA OF WORK ELECTRICAL AND C OMMU NICATION LEGEND: GENERAL NOTES: CONTRACTOR TO PROVIDE ALL ELECTRICAL WORK AND TEL/COMM. WALL CONDUIT AND JUNCTION BOXES RECESSED IN WALLS ONLY U.N.O. TENANT TO PROVIDE ALL TEL/COMM. WIRING ( CAT 6) , & FINAL TERMINATIONS & TEL/COMM. OUTLETS. CONTRACTOR TO REMOVE ALL EXISTING COMM. WIRING NOT TO BE RE-USED ( COORDINATE WITH TENANT'S VENDOR) AND ALL ELEC./COMM. DEVICES IN WALLS TO BE REMOVED. ELEC TRICAL AND C OMMU NICATION NOTES: ELEC TRICAL: 1. 2. 3. 4. EXISTING DUPLEX ELECTRICAL RECEPTACLE WALL MOUNTED d gfi NEW DUPLEX ELECTRICAL RECEPTACLE WALL MOUNTED DEDICATED ELEC. CIRCUIT ( 20 AMP) GROUND FAULT PROTECTION NEW TELEPHONE/COMMUNICATION ( DATA) OUTLET WALL MOUNTED PP POWER POLE TO CONNECT SYSTEMS FURNITURE WITH POWER & COMMUNICATION WIRING. CONTRACTOR TO PROVIDE JUNCTION BOX ABOVE CEILING AND CONNECT POWER TO TENANT FURNISHED POWER POLES. VERIFY POWER REQUIREMENT/CIRCUITS. 5211 W. BROAD ST. 1 ELEC TRIC AL & C OMMU NICATION PLAN PROJECT NO: 2418.02 ALL RECEPTACLES SHALL BE MOUNTED MIN. OF 18" ABOVE FINISHED FLOOR WITH BUILDING STANDARD RECEPTACLE COVERS UNLESS OTHERWISE NOTED. PATCH WALL WHERE ANY WALL MOUNTED OUTLETS ARE REMOVED. CONTRACTOR SHALL REVIEW WITH TENANT LOCATIONS, INSTALLATION AND TYPES OF ELECTRICAL AND COMMUNICATION OUTLETS AND CONDUIT/JUNCTION BOX SIZES REQUIRED AS WELL AS RESPONSIBILITIES OF WORK TO BE PERFORMED BY TENANT AND CONTRACTOR. CONTRACTOR SHALL PERFORM ALL REQUIRED ENGINEERING REQUIRED TO PROPERLY CIRCUIT AND RUN ALL CABLING IN ACCORDANCE WITH THE NEC, GOOD ENGINEERING PRACTICES AND LOCAL ORDINANCES HAVING JURISDICTION. ALL NEW WORK SHALL MATCH BUILDING STANDARD ELECTRICAL WORK PRESENTLY IN PLACE WITH EQUAL OR BETTER MEANS AND METHODS. C OMMU NIC ATION: 1. 2. 3. CONTRACTOR TO FURNISH AND INSTALL WALL OUTLET BOX WITH PULL STRING TO CEILING PLENUM ABOVE. TENANT TO PROVIDE CABLING AND FINAL CONNECTIONS. CONTRACTOR TO PROVIDE BLDG. STD. COVER PLATES FOR ALL UN-USED BOXES. CONTRACTOR SHALL REMOVE ALL EXISTING WIRING NOT TO BE REUSED. KEY P LAN REFERENCE NORTH ELECT/ COMMU N. P LAN SHEET: A3 OF 4 NO NEW/EX. MATL WIDTH H.M. WD. 3'-0" HEIGHT THICK HAR DWAR E S C HEDU LE: FIN HDW FTYPE FMATL FFIN REMARKS - - B.S. - H.M. HM - EXISTING FIRE STAIR DOOR TO REMAIN "AS-IS" - 7'-0" 7'-0" 1 3/4" 7'-0" - - - - HM - WD. 3'-0" 7'-0" 1 3/4" STN LS#2 B.S. HM - EXISTING ELEVATOR DOORS - NO CHANGE MATCH TYPE & FINISHES TO EXISTING DOOR D02. WD. 3'-0" 7'-0" PS#1 B.S. HM PT-2 - WD. WD 7'-0" 7'-0" 1 3/4" 1 3/4" 1 3/4" PT-2 3'-0" 3'-0" PT-2 PT-2 PS#1 PS#1 B.S. B.S. H.M. H.M. PT-2 PT-2 -ADD LITE KIT TO EXISTING DOOR. EXIST C WD 3-0" 7'-0" 1 3/4" PT-2 LS#4 B.S. HM PT-2 ADD NEW PANIC HARDWARE & 8" x 30" LITE KITE. EXIST C EXIST A WD 3'-0" 7'-0" 1 3/4" PT-2 LS#4 B.S. HM PT-2 WD 3'-0" 7'-0" 1 3/4" PT-2 LS#3 B.S. HM PT-2 ADD NEW PANIC HARDWARE & 8" x 30" LITE KITE. - WD 3'-0" 7'-0" PS#1 B.S. HM - ADD LITE KIT TO EXISTING DOOR. WD 3'-0" PT-2 LS#1 D12 WD 3-0" 1 3/4" PT-2 LS#1 B.S. B.S. H.M. HM PT-2 PT-2 ADD NEW FIRE RATED ( 20 MIN.) LITE KIT TO EXIST. DOOR. EXIST B 7'-0" 7'-0" 1 3/4" 1 3/4" PT-2 D11 EXIST C EXIST B D13 EXIST B EXIST B EXIST B WD 7'-0" 1 3/4" PT-2 LS#1 B.S. HM PT-2 ADD NEW FIRE RATED ( 20 MIN.) LITE KIT TO EXIST. DOOR. WD 3'-0" 3'-0" LS#1 LS#1 HM B.S. HM PT-2 PT-2 ADD NEW FIRE RATED ( 20 MIN.) LITE KIT TO EXIST. DOOR. 1 3/4" 1 3/4" PT-2 PT-2 B.S. 3'-0" 7'-0" 7'-0" 1 3/4" WD B.S. B.S. H.M. HM PT-2 PT-2 ADD NEW FIRE RATED ( 20 MIN.) LITE KIT TO EXIST. DOOR. B.S. HM PT-2 ADD NEW FIRE RATED ( 20 MIN.) LITE KIT TO EXIST. DOOR. EXIST EX. D02 EXIST EX. D03 H.M. D04 EXIST EX. NEW C D05 NEW D06A D06B EXIST. C NEW C D07 D08 D10 D14 D15 C PR. 3-0" 1 3/4" D16 EXIST B WD 3'-0" 7'-0" PT-2 LS#1 D17 EXIST B WD 3-0" 7'-0" 1 3/4" PT-2 D18 WD 1 3/4" PT-2 WD 3'-0" 3'-0" 7'-0" D19 EXIST B EXIST C LS#1 LS#1 D20 EXIST - H.M. 3'-0" D21 NEW D22 EXIST B WD WD D23 EXIST B EXIST B WD D24 D25 D26 EXIST C EXIST. A WD D27 D28 EXIST B EXIST C EXIST B D29 D30 D31 C WD WD WD WD WD PT-2 PS#1 B.S. HM PT-2 PT-2 LS#4 B.S. HM PT-2 VERIFY PROPER OPERATION OF EXISTING EGRESS DOOR. 3'-0" PS#1 3-0" 7'-0" PT-2 LS#1 B.S. B.S. H.M. HM PT-2 PT-2 - 1 3/4" PT-2 3'-0" 3'-0" 7'-0" 1 3/4" PT-2 LS#1 B.S. HM PT-2 7'-0" 1 3/4" PT-2 LS#1 B.S. HM PT-2 ADD NEW LITE KIT TO EXIST. DOOR. ADD NEW LITE KIT TO EXIST. DOOR. 3'-0" 3'-0" 7'-0" 7'-0" PT-2 PS#1 LS#1 7'-0" 7'-0" B.S. B.S. B.S. HM H.M. HM PT-2 3-0" 3'-0" 3'-0" 1 3/4" 1 3/4" 1 3/4" B.S. HM PT-2 3'-0" 3'-0" 3'-0" 7'-0" 7'-0" D32 D33 3'-0" 7'-0" D34 D35 NEW NEW B B WD WD 3'-0" 3-0" 7'-0" 7'-0" D36 D37 NEW NEW B B WD WD 3'-0" 3'-0" 7'-0" 7'-0" D38 D39 EXIST A EXIST A WD 3'-0" 3'-0" 7'-0" D40 D41 D42 NEW B EXIST A EXIST A D43 D44 EXIST A EXIST A WD 3-0" 3'-0" 3'-0" WD WD 3'-0" 3'-0" 7'-0" 7'-0" 7'-0" 7'-0" 7'-0" 7'-0" 7'-0" 7'-0" 1 3/4" PT-2 PT-2 1 3/4" 1 3/4" 1 3/4" PT-2 LS#1 B.S. HM PT-2 PT-2 LS#1 LS#1 B.S. B.S. HM HM PT-2 PT-2 PT-2 1 3/4" 1 3/4" 1 3/4" 1 3/4" PT-2 PT-2 LS#1 LS#1 B.S. B.S. HM HM PT-2 PT-2 PT-2 PT-2 LS#1 LS#1 B.S. B.S. H.M. HM PT-2 PT-2 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" PT-2 PT-2 LS#1 LS#1 B.S. B.S. HM HM PT-2 LS#1 LS#1 B.S. B.S. B.S. HM H.M. HM PT-2 PT-2 PT-2 B.S. 1 3/4" 1 3/4" 1 3/4" 1 3/4" PT-2 PT-2 PT-2 LS#3 LS#3 PT-2 PT-2 PT-2 VERIFY PROPER OPERATION OF EXIST. DOOR. VERIFY PROPER OPERATION OF EXIST. DOOR. VERIFY PROPER OPERATION OF EXIST. DOOR. - B.S. B.S. HM HM 24"x30" LITE KIT ( F.R. AS INDICATED ON SCHEDULE) - A STANDARD DOOR B.S. WOOD DOOR IN HM FRAME. B.S. WOOD DOOR IN HM FRAME. ADD NEW LITE KIT TO EXIST. DOOR. - - PT-2 PT-2 B.S. WOOD DOOR IN HM FRAME. ADD NEW LITE KIT TO EXIST. DOOR. PT-2 HM DOOR & WI NDOW TYPES: ADD NEW LITE KIT TO EXIST. DOOR. ADD NEW LITE KIT TO EXIST. DOOR. ADD NEW LITE KIT TO EXIST. DOOR. HM B.S. LS#3 - BUILDING STANDARD CLOSET DOOR LOCK SET. CLOSET FUNCTION, B.S. HINGES, DOOR STOP. ADD NEW LITE KIT TO EXIST. DOOR. - - LS#2 - BUILDING STANDARD ENTRY DOOR LOCK SET -ENTRANCE DOOR LOCK W/ INSIDE ALWAYS FREE, B.S. DOOR CLOSER, B.S. 1 1/2 PAIR HINGES, DOOR STOP COORDINATE DOOR HARDWARE WITH TENANT CONTROLLED ACCESS DEVICES. LS#4 - NEW PANIC PUSHBAR RELEASE FROM INSIDE OF SPACE. WITH LEVER LATCHSET ON OUTSIDE. INSIDE ALWAYS FREE, B.S. 1 1/2 PAIR HINGES, B.S. DOOR STOP. RELOCATED DOOR, ADD 24" x 30" LITE KIT. PT-2 PT-2 PT-2 LS#1 - BUILDING STANDARD OFFICE DOOR LOCK SET RM. LOCKSET. OFFICE FUNCTION, INSIDE ALWAYS FREE, B.S. HINGES, DOOR STOP. SEVENTH & FRANKLIN BUILDING 701 EAST FRANKLIN STREET SUITE 1115 RICHMOND, VIRGINIA 23219-2510 ( 804) 783-9800 ( 804) 783-9801 FAX AIS.AIS@VERIZON.NET ADD NEW FIRE RATED ( 20 MIN.) LITE KIT TO EXIST. DOOR. 1 3/4" 1 3/4" WD WD WD WD WD ADD NEW FIRE RATED ( 20 MIN.) LITE KIT TO EXIST. DOOR. 1 3/4" LS#1 PS#1 PS#1 - BUILDING STANDARD ( B.S.) PASSAGE SET B.S. LEVER HARDWARE, B.S. DOOR HINGES, B.S. WALL MOUNTED ( U.N.O.) DOOR STOP ADD NEW FIRE RATED ( 20 MIN.) LITE KIT TO EXIST. DOOR. 7'-0" 7'-0" 7'-0" PT-2 PT-2 PT-2 CONTRACTOR SHALL COORDINATE ALL DOOR HARDWARE TO MATCH EXISTING TENANT HARDWARE AND FUNCTION. COORDINATE ALL CONTROLLED ACCESS DEVICES AND LOCKS WITH TENANT PRIOR TO HARDWARE ORDER. - ADD NEW PANIC HARDWARE & 8" x 30" LITE KITE. EXIST B EXIST B NEW B NEW B WD WD EXISTING TENANT ENTRY DOORS TO REMAIN "AS-IS" NOTES: CONTRACTOR TO RE-USE & MATCH TO EXISTING BUILDING STANDARD DOORS, H.M. FRAMES & LEVER HARDWARE WHERE POSSIBLE. SEE DOOR SCHEDULE. NEW HARDWARE TO MATCH EXISTING . CONTRACTOR TO PROVIDE FINAL TOUCH-UP OF ALL DOORS TO PROVIDE NEW-LIKE APPEARANCE. 43" MAX AF D01 D09 ROOM S C HEDULE TYPE DOOR S C HEDU LE 8"x30" LITE KIT 43" MAX AF FINIS H S C HEDU LE B OFFICE DOOR C CONFERENCE ROOM DOOR TENANT MODIFICATIONS FOR LU MBER LIQUIDATORS S U ITE 200 5211 W. BROAD STREET HENRICO, VIRGINIA 3/4" THK SHELVES ( MEL-1 FINISH) W/ ADJ. BRACKETS PLAM FINISHED END BUTCHER BLOCK COUNTERTOP. - TENANT FURNISHED; CONTRACTOR INSTALLED. PLAM FINISHED END DEDICATED ELEC. OUTLET @46"A.F. DEDICATED & GFI ELEC. OUTLET @46"A.F. MICROWAVE SHELF 18" D x 1 1/2" THK.) & RECESSED AREA. ( UPPER & LOWER) ADA SINGLE BOWL SINK P-1 DEDICATED & GFI ELEC. OUTLET @46"A.F. DEDICATED ELEC. OUTLET @30"A.F. TENANT FURNISHED REFRIGERATOR TENANT FURNISHED VENDING MACHINE CONTRACTOR FURNISHED WATER CONNECTIONSVERIFY NUMBER REQ'D. PLAM FINISHED END 3/4" THK SHELVES ( MEL-1 FINISH) W/ ADJ. BRACKETS ER T INSULATED PIPES C T C FULL EXTENSION DRAWERS ( MEL-1) IF I ED ARCH I TE OPEN SCALE: 1/8" = 1'-0" PROJECT NO: 2418.02 1. 1. 3. 4. 5. ALL SPACES IN AREAS OF WORK SHALL RECEIVE NEW FINISHES UNLESS OTHERWISE NOTED. SEE FINISH AND ROOM SCHEDULES. OPTION WORK MAY INCLUDE UPDATED FINISHES IN MENS TOILET ROOM, AND NEW LOBBY FLOORING. CONTRACTOR SHALL FOLLOW MANUFACTURER'S REQUIREMENTS FOR PROPER INSTALLATION OF ALL FINISHES AS SCHEDULED. FOLLOW MANUFACTURER'S RECOMMENDATIONS FOR SURFACE PREPARATION. REPAIR ALL EXISTING SURFACES TO PROVIDE SMOOTH AND STRAIGHT SURFACES TO RECEIVE NEW FINISHES. REPAIRS SHALL INCLUDE PATCHING AND LEVELING OF FLOOR SURFACES AND DRYWALL . CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD MEASURING & ALL CALCULATIONS FOR MATERIAL QUANTITY NEEDED AND RECEIVING AND INSPECTION FOR FLAWS. CONTRACTOR IS RESPONSIBLE FOR CLEAN-UP OF ALL FINISH MATERIALS WITH FINISHES TO BE CLEAN AND FREE OF MARKS, LOOSE THREADS AND OTHER IMPERFECTIONS. PROVIDE ALL TRANSITION STRIPS MEETING ACCESSIBLE STANDARDS AND MATCHING MATERIALS & FINISH JOINING CARPET AREAS I.E. WOOD TRANSITION STRIP AT WOOD/CARPET TRANSITION, AND/OR OTHER SIMILIAR MATERIALS WHERE APPLICABLE. CONTRACTOR SHALL RETURN ALL SURPLUS PAINT, CARPET & BASE OVER TO TENANT FOR LATER REPAIRS/ REPLACEMENT. 1 DATE: 24 MARCH 2015 SCALE: 1/2" = 1'-0" C AS EWORK NO TES : AREA OF WORK PLU MB ING FIXTURE S C HEDULE 5211 W. BROAD ST. FINIS H NO TES : NEW WALL & BAS E C AB INETS & C OU NTERTOP W/ NEW S INK IN AREA 213 1. ALL PLASTIC LAMINATE CASEWORK ITEMS SHALL BE FABRICATED IN STRICT ACCORDANCE WITH AWI SECTION 400 CUSTOM GRADE WITH FLUSH OVERLAY CONSTRUCTION W/ PLASTIC LAMINATE EXPOSED SURFACES. SEE FINISH SCHEDULE FOR FINISH SELECTIONS. 2. CONTRACTOR TO PROVIDE SURFACE WOOD BLOCKING AS REQUIRED TO PROVIDE PROPER SUPPORT OF WALL HUNG CASEWORK. BRACE WALLS TO STRUCTURE ABOVE AS REQUIRED. CONTRACTOR SHALL PROVIDE AND INSTALL PLUMBING FIXTURES AS INDICATED AND PROVIDE ANY ADDITIONAL ASSEMBLIES INCLUDING DRAIN, STRAINER, STOP, BACK-FLOW PREVENTER, ETC. TO PROVIDE A COMPLETE FIXTURE INSTALLATION. SEE PLUMBING FIXTURE SCHEDULE FOR NEW SINK & PROVIDE NEW WATER CONNECTIONS FOR ICE MAKER IN REFRIGERATOR ( TENANT FURNISHED) APPLIANCES AND WATER CONNECTIONS FOR VENDING MACHINES AS NEEDED. 3. THE SINK SHALL COMPLY WITH ICC A117.1-2009 FOR ACCESSIBILITY. MODIFICATIONS SHALL BE MADE TO PROVIDE FULL COMPLIANCE. P LU MBING NOTES : 1. CONTRACTOR SHALL COORDINATE ALL WORK WITH ARCHITECTURAL DRAWING, EXISTING PLUMBING LINES, & PROPOSED FIXTURES & NEW WALLS PRIOR TO ROUGH-IN PLUMBING FIXTURES AND CAPPING/RE-CONFIG. EXISTING LINES. 2. TRENCHING, INSUALTION AND BACK-FILLING FOR PIPING AND MAINTAINING PROPER SLOPE PIPE SIZING & PROVIDING APPROVED ENGINEERED DRAWINGS OF ALL PLUMBING WORK SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. 3. ALL PIPING SHALL BE CONCEALED IN WALLS AND ANY MAIN WATER CUT-OFFS OR CONTROLS IN WALLS WILL BE ACCESSED THRU FLUSH ACCESS DOORS. KEY P LAN REFERENCE NORTH S C HEDU LES & DETAILS SHEET: A4 OF 4