Theraflow - Aidacare

Transcription

Theraflow - Aidacare
Alternating Air Mattress Range
‘Breakthrough Pressure Relief Technology’
Theraflow
™
Mattress Selection
Guide
20+
Very High Risk
15+
Very High Risk
Existing Pressure
Area/s?
Yes
<10
Low Risk
10+
At Risk
No
Treatment
Solutions
Prevention
Solutions
Patient Weight
180+
Patient Weight
180+
No
Foot Ulcer Only
Yes
No
Yes
Focussed Reperfusion
Treatment
No
Yes
No
Theraflow
Yes
Diabetic or Labile
Blood Flow
No
No
Patient can self assist
for transfers etc ...
Patient needs permanent
incline for respiration
Yes
Theraflow
Bariatric
Patient Weight>100kg
AirLo8
Mattress Replacement
with Heel Suspension
Yes
No
Airlo5
Overlay
Airlo3
Overlay
Yes
Mattress Specifications
Air-Lo 3
Air-Lo 5
Air-Lo 8
Theraflow
Standard
Theraflow
King Single
Theraflow
Bariatric
PTM636629
PTM636630
PTM636635
PTM636640
PTM636645
PTM636646
MATTRESS SPECS
Dimensions
(mm)
(W x H x D)
2000 x 900 x 100
2000 x 900 x 130
2000 x 900 x 210
2000 x 900 x 250
2000 x 1070 x 250
2000 x 1070 x 250
No. of Cells
22
18
20
28
28
28
Static Head
Cells
3
3
3
4
4
4
Side Bolster
Cells
-
-
-
-
2 Aside
2 Aside
Cell
Material
TPU
TPU
TPU
TPU,
Nylon TPU
TPU, High Density,
Multi-zoned
Cell Cycle
1 in 2
1 in 2
1 in 2
Paired 1 in 2
Paired 1 in 2
Paired 1 in 2
Alternating
Mode
14 minutes per
cycle
14 minutes per
cycle
14 minutes per
cycle
14 minutes per
cycle
14 minutes per
cycle
14 minutes per
cycle
Positioning
Handles
-
-
2 aside
2 aside
2 aside
2 aside
12 months
12 months
12 months
12 months
12 months
12 months
Plastibert 2 way
stretch - Welded
Plastibert 2 way
stretch - Welded
Plastibert 2 way
stretch - Welded
Dartex - Welded
Dartex - Welded
Sioen Multi
Stretch - Welded
Nylon TPU Welded
Nylon TPU Welded
Nylon TPU - Welded
Assorted PU &
PVCs - Welded
Assorted PU &
PVCs - Welded
Assorted PU &
PVCs - Welded
Warranty
COVER SPECS
Top Cover
Base/s
CONTROL UNIT SPECS
Dimensions
(mm)
(W x H x D)
270 x 210 x 100
270 x 210 x 100
270 x 210 x 100
250 x 250 x 170
250 x 250 x 170
250 x 250 x 170
Weight
2.5 kg
2.5 kg
2.5 kg
3 kg
3 kg
3 kg
Power
Rating
240V 50Hz 12VA
240V 50Hz 12VA
240V 50Hz 12VA
240V 50Hz 12VA
240V 50Hz 12VA
240V 50Hz 12VA
10 L/min
10 L/min
10 L/min
20 L/min
20 L/min
20 L/min
Static/
Transport
Mode
Timeout - 60 mins
Timeout - 60 mins
Timeout - 60 mins
Timeout - 60 mins
Timeout - 60 mins
Timeout - 60 mins
Care Mode
-
Timeout - 20 mins
Timeout - 20 mins
Timeout - 20 mins
Timeout - 20 mins
Timeout - 20 mins
Incline Mode
-
w/ Auto Tilt
Sensor
w/ Auto Tilt
Sensor
-
-
-
24 months
24 months
24 months
24 months
24 months
24 months
Air Flow
Warranty
For years, the Australian market has had to make do with older generation active
pressure care technology at the more affordable end of the market. Now finally,
the Air-Lo line of support systems makes available the latest in alternating technology
and quality previously only seen in higher end systems. The information below
represents a summary of the main quality differences that make ALL the difference
in Therapy, Infection Control and Comfort.
The Therapy Difference
Feature
Advantage
Machine welded thermal
polyurethane cells
Strong construction provides support wit stretch properties for comfort
and care
Two way stretch European
top cover
Better stretch properties result in improvedpressure release and comfort
Hi flow computer controlled
air distributor
Gives instant response to user input and longer deflation periods.
Larger release valve ensures faster deflation.
Latest generation therapy program
Results in more pressure release through thealternation cycle with less
inflation time
Unbeatable Infection Control
Feature
Advantage
Machine welded top cover
and base
No stitching or tape that can break down or allow moisture wicking
into the cell section.
European PU top cover 95° machine
wash and tumble
dry for disinfection
A heat wash at a higher temperature more effectively kills bacteria
such as MRSA
Welded low profile zipper
with plastised backing
This minimises the chance of any moisture ingress through the zipper
sections
Designer Innovations
Feature
Advantage
Internal power cord
Removes chance of fouling in bed or on floor
Simple to operate
control units
Auto lockout plus Care and Static Mode timeouts for maximum safety
Optional Hyper-stretch
coverlet that fits all Air-Lo’s
For unrivalled comfort, insulation from cellchill and protection from
reperfusion injury
All Control Units
Feature
Output
10 Ipm
Rotor Valve
Computer Controlled
Air Release
Full Hose Diameter
Noise Levels
Internal Muffler system
Hose Connect
Single moulding
Auto Timeouts
20 minutes Care Mode at Max pressure
60 minutes Static Mode for inclined meals or transport
Power
Internal to mattress
Breakaway system
Optional
Air Alternating Overlay
Support System
The Air-Lo 3 Alternating Overlay leads the field in affordable prevention of pressure areas and skin breakdowns where
a lower profile overlay for lighter patients is desirable.
It’s compact, powerful yet almost silent control unit can quickly support patient loads of up to 100kg whilst alternately
allowing pressure to be released across the rest of the body.
When an affordable support and therapy system is required, the Air-Lo 3 Alternating Overlay is the best value choice
for safely caring for patients assessed at risk of developing pressure areas.
High quality two way stretch top cover
is fully welded and can be high temperature
washed for total infection control.
Static head section eliminates patient dizziness
and disorientation.
Elasticised side straps
securely bond the
overlay to any regular
single mattress.
22 pure TPU transverse air cells alternate
one in every two. They stretch under the
patient to provide maximum comfort,
prevention and therapy.
All waterfalls are turned
and welded for maximum infection
control and zip protection.
Power cord is run inside the
mattress to avoid dangerous
threading under the bed
or on the floor.
Easy to use analogue control unit features a manual comfort dial, static mode
with a 60 minute auto time-out and simple diagnostics. Intermittent operation
ensures long pump life.
3
Optional open cell foam
and Microfibre Coverlet
(made to order in Australia)
Static Head Cells
Opening in zip to
allow for power cord exit
Legend
A series cells and hose
B series cells and hose
Static head cells and hose
Tag with serial number
to match top cover
and pump
Internal power cord
Standard 5m Black IEC
Zip for top cover
Small pouch at end of zip
to allow entry of power cord
Zip for optional coverlet
One way valve
© Patient Support Systems Pty Ltd 2012
An optional internal
Air-Lo HyperStretch Coverlet
can easily be fitted
under all AirLo top
covers to ensure
maximum patient
comfort and
insulation.
5
Air Alternating Overlay
with Auto Tilt Sensor & Heel Suspension
The Air-Lo 5 Alternating Overlay leads the field in affordable prevention of pressure areas and skin breakdowns where
a complete mattresses replacement is undesirable.
It’s compact, powerful yet almost silent control unit can quickly support patient loads of up to 120kg whilst alternately
allowing pressure to be released across the rest of the body.
When only the very best prevention, support and therapy are required, the Air-Lo 5 Alternating
Overlay is the best value choice for safely caring for patients assessed at medium to high risk.
High quality two way stretch top cover
is fully welded and can be high temperature
washed for total infection control.
Static head section eliminates patient dizziness
and disorientation.
Tilt Sensor automatically adds more
pressure when patient is inclined.
18 transverse air cells alternate to provide
maximum prevention and therapy.
High capacity yet unobtrusive
side CPR release gives maximum
safety in the event of pulmonary
emergency.
All waterfalls are turned and welded for maximum
infection control and zip protection.
Mattress elastics securely bond the overlay to
any standard single mattress.
Cell disconnection valves allow
the end four foot cells to be
completely deflated to assist
in suspending a patient’s heels.
Choice of three care modes and comfort
settings in a simple to operate digital
control unit with tamper proof lockout,
static time-outs and simple diagnostics.
Intermittent operation ensures long
pump life.
Medical grade power cord is run inside the mattress to avoid
dangerous threading under the bed or on the floor.
A state of the art, internal air release valve is directly connected to the computer
for instant response.
It’s high capacity ensures the fastest release of pressure possible.
5
Optional Open cell foam
and Microfibre Coverlet
(made to order in Australia)
Opening in zip to
allow for power cord exit
Legend
A series cells and hose
B series cells and hose
Static head cells and hose
Tag with serial number
to match top cover
and pump
Internal power cord
Standard 5m Black IEC
Zip for top cover
Small pouch at end of zip
to allow entry of power cord
Zip for optional coverlet
One way valve
CPR release welded to base
© Patient Support Systems Pty Ltd 2011
An optional internal
Air-Lo HyperStretch Coverlet
can easily be fitted
under all AirLo top
covers to ensure
maximum patient
comfort and
insulation.
8
Air Alternating Mattress
with Auto Tilt Sensor & Heel Suspension
The Air-Lo 8 Alternating Mattress Replacement leads the field in affordable prevention of pressure areas
and skin breakdowns.
It’s compact, powerful yet almost silent control unit can quickly support patient loads of up to 180kg whilst alternately
allowing pressure to be released across the rest of the body.
When only the very best prevention, support and therapy are required, the Air-Lo 8 Mattress Replacement is the best
value choice for safely caring for patients assessed at high risk.
High quality two way stretch top cover is fully welded and can be
high temperature washed for total infection control.
Static head section eliminates patient
dizziness and disorientation.
Auto Tilt Sensor adjusts pressure
when patient is inclined.
20 transverse air cells alternate to provide
maximum prevention and therapy.
High capacity yet unobtrusive
side CPR release gives
maximum safety in the event of
pulminary emergency. This new
design can easily be opened or
closed without having to un-zip
the top cover.
They also feature permanently inflated safety
sections for total peace of mind.
Cell disconnection valves allow
the top two thirds of the end
four foot cells to be completely
deflated to fully suspend
a patient heels.
All waterfalls are turned and
welded for maximum infection
control and zip protection
Choice of three care modes and comfort settings in
a simple to operate digital control unit with tamper
proof lockout, static timeouts and simple diagnostics.
Intermittent operation ensures long pump life.
Medical grade power cord is run
inside the mattress to avoid dangerous
threading under the bed or on the floor.
A state of the art, internal air release valve is directly connected to the computer
for instant response.
It’s high capacity ensures the fastest release of pressure possible.
8
Optional Open cell foam
and Microfibre Coverlet
(made to order in Australia)
Opening in zip to
allow for power cord
Legend
A series cell zones & hose
B series cell zones & hose
Static head cells/zones & hose
Tag with serial number
to match top cover
and pump
Internal power cord
Standard 5m Black IEC
Zip for top cover
Small pouch at end of zip
to allow entry of power cord
Zip for optional coverlet
CPR release welded to base
Side straps with clips
© Patient Support Systems Pty Ltd 2011
An optional internal
Air-Lo HyperStretch Coverlet
can easily be fitted
under all AirLo top
covers to ensure
maximum patient
comfort and
insulation.
Compare the Difference
Wound Prevention & Treatment to Grade 4
Mostly Prevention-Some Therapy
Cell Elastics remove pressure faster longer
Heels not just relieved but totally elevated
Passive pressure release only
Heels relieved but not elevated
Targeted Wound Treatment Option
No Targeted Treatment Option
Disengage cell elastics to focus treatment
All cells alternate the same
Comfort without Compromise to Therapy
Discomfort Often Experienced
Foam underlay insulates against “cell chill”
Foam underlay reduces risk of tissue shear
Patient very close to cold cells
Firm cells may cause shearing
Total Infection Control
Top Cover Tape Sealed Only
All outer surfaces welded - cover and base
OK for repeated high temperature washes
No bed straps necessary - Autostick base
Most bases stitched not welded
Base difficult to clean separately
Bed straps often tear on frame
Theraflow Standard
Reperfusion Support System
DynamULink™ Turbocharged Deflation
A new patented cell design uses elasticised members to transfer the power of inflating cells to force down
the deflating sets.
This alternately removes almost all interface pressure under nearly 80% of the patient’s body. The at risk heel area
is completely elevated for nearly 30% of the alternation cycle.
This unique cell design allows cell pairs to naturally remain upright when normal cells deform or collapse under
patient weight.
Infection Control: All outer surfaces are fully welded. A unique “mattress within a mattress” design ensures
complete protection.
Reperfusion Support System
DynamULink™ Turbocharged Deflation
CellStay™
indictation
A new patented cell design uses elasticised
members to transfer the power of inflating cells
to force down the deflating sets.
Theraflow™
This alternately removes almost all interface
pressure under nearly 80% of the patient’s body
X-Sensor Pressure Map Data
Male 42 - 90kgs 2010
REPERFUSION SUPPORT SURFACE
The at risk heel area is completely elevated for
nearly 30% of the alternation cycle.
Design so advanced - it’s
A highly stre
systems bet
Industry Leader
This unique cell design allows cell pairs to
naturally remain upright when normal cells
adeform
quantum
leapunder
in therapy
or collapse
patient weight.
Independent tests show pressure release performance up to 200% more effective than current industry leading
alternating systems!
Infection Control: All outer surfaces are fully
√√
√√
√√
√√
√√
√√
Completel
welded. A unique “mattress within a mattress”
Unparalleled comfort without
“chill”
designthe
ensures
complete protection.
Elastic mem
focusing the
Cells that collapse away from the patient
Heels not just relieved but totally elevated
Customise to focus therapy to any area
Reperfusion performance to treat ulcers
Fully welded for total infection control
Sacrum
Heel
35
30
25
Pressure
in mmHg
Industry Leader
Theraflow
20
15
10
5
0
Pressure Release Performance Comparisons
Patient Age: 42, Sex: Male Weight: 90kg
Graphs show pressure release section of alternation cycle.
1
2
3
4
5
Time (Mins)
6
7
1
2
3
4
5
6
7
Time (Mins)
8
9
10
King Single
Reperfusion Support System
Breakthrough pressure release technology just got wider!
All the advantages of the original Theraflow alternating mattress replacement have been designed into this new
extended support system recommended for patients weighing from 40 to 180kg.
Enhanced Patient Support
Additional, static side cells provide additional support to the to patients especially during transfers and repositioning.
The new Theraflow King Single can fit any standard king single bed measuring around 105 to 110 cm in width.
New Cellstay Support Coverlet
A robust side skirt design integrated into the coverlet binds the whole mattress together increasing the system’s ability
to support a variety of patient loads safely and securely.
Microfibre Foam for Enhanced Therapy
The coverlet is constructed with a 5cm layer of hyperstretch open cell foam which in turn is coated with a microfibre
material similar to that used in high performance athletic wear to wick moisture away from the body.
The coverlet therefore not only insulates the patient from “Cell Chill” but also from any excess moisture buildup.
The thin foam layer also assists in avoiding reperfusion injury in patients at high risk of sub-dermal vascular damage.
Turbocharged Deflation
The patented dynamulink cell design uses elasticised members to transfer the power of inflating cells to force down
the deflating sets.
This alternately removes almost all interface pressure under nearly 80% of the patient’s body
The at risk heel area is completely elevated for nearly 30% of the alternation cycle.
This unique cell design allows cell pairs to naturally remain upright when normal cells deform or collapse under
patient weight.
Sacrum
Heel
35
30
25
Pressure
in mmHg
Industry Leader
Theraflow
20
15
10
5
0
Pressure Release Performance Comparisons
Patient Age: 42, Sex: Male Weight: 90kg
Graphs show pressure release section of alternation cycle.
1
2
3
4
5
Time (Mins)
6
7
1
2
3
4
5
6
7
Time (Mins)
8
9
10
BARIATRIC
Reperfusion Support System
Breakthrough pressure release technology just got heavy duty!
All the advantages of the original Theraflow alternating mattress replacement have been designed into this new
bariatric support system.
Enhanced Patient Support
Additional, static side cells provide additional support to the heavier patient especially during transfers and patient
repositioning. The new Theraflow Bariatric can fit any standard king single bed measuring 107cm in width.
New Cellstay Support Coverlet
A robust side skirt design integrated into the coverlet binds the whole mattress together increasing the systems ability
to support a variety of patient loads safely and securely.
Microfibre Foam for Enhanced Therapy
The coverlet is constructed with a 5cm layer of hyperstretch open cell foam which in turn is coated with a microfibre
material similar to that used in high performance athletic wear to wick moisture away from the body.
The coverlet therefore not only insulates the patient from “Cell Chill” but also from any excess moisture buildup. The
thin foam layer also assists in avoiding reperfusion injury in patients at high risk of sub-dermal vascular damage.
Turbocharged Deflation
The patented dynamulink cell design uses elasticised members to transfer the power of inflating cells to force down
the deflating sets.
This alternately removes almost all interface pressure under nearly 80% of the patient’s body
The at risk heel area is completely elevated for nearly 30% of the alternation cycle.
This unique cell design allows cell pairs to naturally remain upright when normal cells deform or collapse under
patient weight.
Sacrum
Heel
35
30
25
Pressure
in mmHg
Industry Leader
Theraflow
20
15
0
10 1
5
Pressure Release Performance Comparisons
Patient Age: 42, Sex: Male Weight: 90kg
Graphs show pressure release section of alternation cycle.
2
3
4
5
Time (Mins)
6
7
1
2
3
4
5
6
7
Time (Mins)
8
9
10
Theraflow
Authorised Distributor:
™