Theraflow - Aidacare
Transcription
Theraflow - Aidacare
Alternating Air Mattress Range ‘Breakthrough Pressure Relief Technology’ Theraflow ™ Mattress Selection Guide 20+ Very High Risk 15+ Very High Risk Existing Pressure Area/s? Yes <10 Low Risk 10+ At Risk No Treatment Solutions Prevention Solutions Patient Weight 180+ Patient Weight 180+ No Foot Ulcer Only Yes No Yes Focussed Reperfusion Treatment No Yes No Theraflow Yes Diabetic or Labile Blood Flow No No Patient can self assist for transfers etc ... Patient needs permanent incline for respiration Yes Theraflow Bariatric Patient Weight>100kg AirLo8 Mattress Replacement with Heel Suspension Yes No Airlo5 Overlay Airlo3 Overlay Yes Mattress Specifications Air-Lo 3 Air-Lo 5 Air-Lo 8 Theraflow Standard Theraflow King Single Theraflow Bariatric PTM636629 PTM636630 PTM636635 PTM636640 PTM636645 PTM636646 MATTRESS SPECS Dimensions (mm) (W x H x D) 2000 x 900 x 100 2000 x 900 x 130 2000 x 900 x 210 2000 x 900 x 250 2000 x 1070 x 250 2000 x 1070 x 250 No. of Cells 22 18 20 28 28 28 Static Head Cells 3 3 3 4 4 4 Side Bolster Cells - - - - 2 Aside 2 Aside Cell Material TPU TPU TPU TPU, Nylon TPU TPU, High Density, Multi-zoned Cell Cycle 1 in 2 1 in 2 1 in 2 Paired 1 in 2 Paired 1 in 2 Paired 1 in 2 Alternating Mode 14 minutes per cycle 14 minutes per cycle 14 minutes per cycle 14 minutes per cycle 14 minutes per cycle 14 minutes per cycle Positioning Handles - - 2 aside 2 aside 2 aside 2 aside 12 months 12 months 12 months 12 months 12 months 12 months Plastibert 2 way stretch - Welded Plastibert 2 way stretch - Welded Plastibert 2 way stretch - Welded Dartex - Welded Dartex - Welded Sioen Multi Stretch - Welded Nylon TPU Welded Nylon TPU Welded Nylon TPU - Welded Assorted PU & PVCs - Welded Assorted PU & PVCs - Welded Assorted PU & PVCs - Welded Warranty COVER SPECS Top Cover Base/s CONTROL UNIT SPECS Dimensions (mm) (W x H x D) 270 x 210 x 100 270 x 210 x 100 270 x 210 x 100 250 x 250 x 170 250 x 250 x 170 250 x 250 x 170 Weight 2.5 kg 2.5 kg 2.5 kg 3 kg 3 kg 3 kg Power Rating 240V 50Hz 12VA 240V 50Hz 12VA 240V 50Hz 12VA 240V 50Hz 12VA 240V 50Hz 12VA 240V 50Hz 12VA 10 L/min 10 L/min 10 L/min 20 L/min 20 L/min 20 L/min Static/ Transport Mode Timeout - 60 mins Timeout - 60 mins Timeout - 60 mins Timeout - 60 mins Timeout - 60 mins Timeout - 60 mins Care Mode - Timeout - 20 mins Timeout - 20 mins Timeout - 20 mins Timeout - 20 mins Timeout - 20 mins Incline Mode - w/ Auto Tilt Sensor w/ Auto Tilt Sensor - - - 24 months 24 months 24 months 24 months 24 months 24 months Air Flow Warranty For years, the Australian market has had to make do with older generation active pressure care technology at the more affordable end of the market. Now finally, the Air-Lo line of support systems makes available the latest in alternating technology and quality previously only seen in higher end systems. The information below represents a summary of the main quality differences that make ALL the difference in Therapy, Infection Control and Comfort. The Therapy Difference Feature Advantage Machine welded thermal polyurethane cells Strong construction provides support wit stretch properties for comfort and care Two way stretch European top cover Better stretch properties result in improvedpressure release and comfort Hi flow computer controlled air distributor Gives instant response to user input and longer deflation periods. Larger release valve ensures faster deflation. Latest generation therapy program Results in more pressure release through thealternation cycle with less inflation time Unbeatable Infection Control Feature Advantage Machine welded top cover and base No stitching or tape that can break down or allow moisture wicking into the cell section. European PU top cover 95° machine wash and tumble dry for disinfection A heat wash at a higher temperature more effectively kills bacteria such as MRSA Welded low profile zipper with plastised backing This minimises the chance of any moisture ingress through the zipper sections Designer Innovations Feature Advantage Internal power cord Removes chance of fouling in bed or on floor Simple to operate control units Auto lockout plus Care and Static Mode timeouts for maximum safety Optional Hyper-stretch coverlet that fits all Air-Lo’s For unrivalled comfort, insulation from cellchill and protection from reperfusion injury All Control Units Feature Output 10 Ipm Rotor Valve Computer Controlled Air Release Full Hose Diameter Noise Levels Internal Muffler system Hose Connect Single moulding Auto Timeouts 20 minutes Care Mode at Max pressure 60 minutes Static Mode for inclined meals or transport Power Internal to mattress Breakaway system Optional Air Alternating Overlay Support System The Air-Lo 3 Alternating Overlay leads the field in affordable prevention of pressure areas and skin breakdowns where a lower profile overlay for lighter patients is desirable. It’s compact, powerful yet almost silent control unit can quickly support patient loads of up to 100kg whilst alternately allowing pressure to be released across the rest of the body. When an affordable support and therapy system is required, the Air-Lo 3 Alternating Overlay is the best value choice for safely caring for patients assessed at risk of developing pressure areas. High quality two way stretch top cover is fully welded and can be high temperature washed for total infection control. Static head section eliminates patient dizziness and disorientation. Elasticised side straps securely bond the overlay to any regular single mattress. 22 pure TPU transverse air cells alternate one in every two. They stretch under the patient to provide maximum comfort, prevention and therapy. All waterfalls are turned and welded for maximum infection control and zip protection. Power cord is run inside the mattress to avoid dangerous threading under the bed or on the floor. Easy to use analogue control unit features a manual comfort dial, static mode with a 60 minute auto time-out and simple diagnostics. Intermittent operation ensures long pump life. 3 Optional open cell foam and Microfibre Coverlet (made to order in Australia) Static Head Cells Opening in zip to allow for power cord exit Legend A series cells and hose B series cells and hose Static head cells and hose Tag with serial number to match top cover and pump Internal power cord Standard 5m Black IEC Zip for top cover Small pouch at end of zip to allow entry of power cord Zip for optional coverlet One way valve © Patient Support Systems Pty Ltd 2012 An optional internal Air-Lo HyperStretch Coverlet can easily be fitted under all AirLo top covers to ensure maximum patient comfort and insulation. 5 Air Alternating Overlay with Auto Tilt Sensor & Heel Suspension The Air-Lo 5 Alternating Overlay leads the field in affordable prevention of pressure areas and skin breakdowns where a complete mattresses replacement is undesirable. It’s compact, powerful yet almost silent control unit can quickly support patient loads of up to 120kg whilst alternately allowing pressure to be released across the rest of the body. When only the very best prevention, support and therapy are required, the Air-Lo 5 Alternating Overlay is the best value choice for safely caring for patients assessed at medium to high risk. High quality two way stretch top cover is fully welded and can be high temperature washed for total infection control. Static head section eliminates patient dizziness and disorientation. Tilt Sensor automatically adds more pressure when patient is inclined. 18 transverse air cells alternate to provide maximum prevention and therapy. High capacity yet unobtrusive side CPR release gives maximum safety in the event of pulmonary emergency. All waterfalls are turned and welded for maximum infection control and zip protection. Mattress elastics securely bond the overlay to any standard single mattress. Cell disconnection valves allow the end four foot cells to be completely deflated to assist in suspending a patient’s heels. Choice of three care modes and comfort settings in a simple to operate digital control unit with tamper proof lockout, static time-outs and simple diagnostics. Intermittent operation ensures long pump life. Medical grade power cord is run inside the mattress to avoid dangerous threading under the bed or on the floor. A state of the art, internal air release valve is directly connected to the computer for instant response. It’s high capacity ensures the fastest release of pressure possible. 5 Optional Open cell foam and Microfibre Coverlet (made to order in Australia) Opening in zip to allow for power cord exit Legend A series cells and hose B series cells and hose Static head cells and hose Tag with serial number to match top cover and pump Internal power cord Standard 5m Black IEC Zip for top cover Small pouch at end of zip to allow entry of power cord Zip for optional coverlet One way valve CPR release welded to base © Patient Support Systems Pty Ltd 2011 An optional internal Air-Lo HyperStretch Coverlet can easily be fitted under all AirLo top covers to ensure maximum patient comfort and insulation. 8 Air Alternating Mattress with Auto Tilt Sensor & Heel Suspension The Air-Lo 8 Alternating Mattress Replacement leads the field in affordable prevention of pressure areas and skin breakdowns. It’s compact, powerful yet almost silent control unit can quickly support patient loads of up to 180kg whilst alternately allowing pressure to be released across the rest of the body. When only the very best prevention, support and therapy are required, the Air-Lo 8 Mattress Replacement is the best value choice for safely caring for patients assessed at high risk. High quality two way stretch top cover is fully welded and can be high temperature washed for total infection control. Static head section eliminates patient dizziness and disorientation. Auto Tilt Sensor adjusts pressure when patient is inclined. 20 transverse air cells alternate to provide maximum prevention and therapy. High capacity yet unobtrusive side CPR release gives maximum safety in the event of pulminary emergency. This new design can easily be opened or closed without having to un-zip the top cover. They also feature permanently inflated safety sections for total peace of mind. Cell disconnection valves allow the top two thirds of the end four foot cells to be completely deflated to fully suspend a patient heels. All waterfalls are turned and welded for maximum infection control and zip protection Choice of three care modes and comfort settings in a simple to operate digital control unit with tamper proof lockout, static timeouts and simple diagnostics. Intermittent operation ensures long pump life. Medical grade power cord is run inside the mattress to avoid dangerous threading under the bed or on the floor. A state of the art, internal air release valve is directly connected to the computer for instant response. It’s high capacity ensures the fastest release of pressure possible. 8 Optional Open cell foam and Microfibre Coverlet (made to order in Australia) Opening in zip to allow for power cord Legend A series cell zones & hose B series cell zones & hose Static head cells/zones & hose Tag with serial number to match top cover and pump Internal power cord Standard 5m Black IEC Zip for top cover Small pouch at end of zip to allow entry of power cord Zip for optional coverlet CPR release welded to base Side straps with clips © Patient Support Systems Pty Ltd 2011 An optional internal Air-Lo HyperStretch Coverlet can easily be fitted under all AirLo top covers to ensure maximum patient comfort and insulation. Compare the Difference Wound Prevention & Treatment to Grade 4 Mostly Prevention-Some Therapy Cell Elastics remove pressure faster longer Heels not just relieved but totally elevated Passive pressure release only Heels relieved but not elevated Targeted Wound Treatment Option No Targeted Treatment Option Disengage cell elastics to focus treatment All cells alternate the same Comfort without Compromise to Therapy Discomfort Often Experienced Foam underlay insulates against “cell chill” Foam underlay reduces risk of tissue shear Patient very close to cold cells Firm cells may cause shearing Total Infection Control Top Cover Tape Sealed Only All outer surfaces welded - cover and base OK for repeated high temperature washes No bed straps necessary - Autostick base Most bases stitched not welded Base difficult to clean separately Bed straps often tear on frame Theraflow Standard Reperfusion Support System DynamULink™ Turbocharged Deflation A new patented cell design uses elasticised members to transfer the power of inflating cells to force down the deflating sets. This alternately removes almost all interface pressure under nearly 80% of the patient’s body. The at risk heel area is completely elevated for nearly 30% of the alternation cycle. This unique cell design allows cell pairs to naturally remain upright when normal cells deform or collapse under patient weight. Infection Control: All outer surfaces are fully welded. A unique “mattress within a mattress” design ensures complete protection. Reperfusion Support System DynamULink™ Turbocharged Deflation CellStay™ indictation A new patented cell design uses elasticised members to transfer the power of inflating cells to force down the deflating sets. Theraflow™ This alternately removes almost all interface pressure under nearly 80% of the patient’s body X-Sensor Pressure Map Data Male 42 - 90kgs 2010 REPERFUSION SUPPORT SURFACE The at risk heel area is completely elevated for nearly 30% of the alternation cycle. Design so advanced - it’s A highly stre systems bet Industry Leader This unique cell design allows cell pairs to naturally remain upright when normal cells adeform quantum leapunder in therapy or collapse patient weight. Independent tests show pressure release performance up to 200% more effective than current industry leading alternating systems! Infection Control: All outer surfaces are fully √√ √√ √√ √√ √√ √√ Completel welded. A unique “mattress within a mattress” Unparalleled comfort without “chill” designthe ensures complete protection. Elastic mem focusing the Cells that collapse away from the patient Heels not just relieved but totally elevated Customise to focus therapy to any area Reperfusion performance to treat ulcers Fully welded for total infection control Sacrum Heel 35 30 25 Pressure in mmHg Industry Leader Theraflow 20 15 10 5 0 Pressure Release Performance Comparisons Patient Age: 42, Sex: Male Weight: 90kg Graphs show pressure release section of alternation cycle. 1 2 3 4 5 Time (Mins) 6 7 1 2 3 4 5 6 7 Time (Mins) 8 9 10 King Single Reperfusion Support System Breakthrough pressure release technology just got wider! All the advantages of the original Theraflow alternating mattress replacement have been designed into this new extended support system recommended for patients weighing from 40 to 180kg. Enhanced Patient Support Additional, static side cells provide additional support to the to patients especially during transfers and repositioning. The new Theraflow King Single can fit any standard king single bed measuring around 105 to 110 cm in width. New Cellstay Support Coverlet A robust side skirt design integrated into the coverlet binds the whole mattress together increasing the system’s ability to support a variety of patient loads safely and securely. Microfibre Foam for Enhanced Therapy The coverlet is constructed with a 5cm layer of hyperstretch open cell foam which in turn is coated with a microfibre material similar to that used in high performance athletic wear to wick moisture away from the body. The coverlet therefore not only insulates the patient from “Cell Chill” but also from any excess moisture buildup. The thin foam layer also assists in avoiding reperfusion injury in patients at high risk of sub-dermal vascular damage. Turbocharged Deflation The patented dynamulink cell design uses elasticised members to transfer the power of inflating cells to force down the deflating sets. This alternately removes almost all interface pressure under nearly 80% of the patient’s body The at risk heel area is completely elevated for nearly 30% of the alternation cycle. This unique cell design allows cell pairs to naturally remain upright when normal cells deform or collapse under patient weight. Sacrum Heel 35 30 25 Pressure in mmHg Industry Leader Theraflow 20 15 10 5 0 Pressure Release Performance Comparisons Patient Age: 42, Sex: Male Weight: 90kg Graphs show pressure release section of alternation cycle. 1 2 3 4 5 Time (Mins) 6 7 1 2 3 4 5 6 7 Time (Mins) 8 9 10 BARIATRIC Reperfusion Support System Breakthrough pressure release technology just got heavy duty! All the advantages of the original Theraflow alternating mattress replacement have been designed into this new bariatric support system. Enhanced Patient Support Additional, static side cells provide additional support to the heavier patient especially during transfers and patient repositioning. The new Theraflow Bariatric can fit any standard king single bed measuring 107cm in width. New Cellstay Support Coverlet A robust side skirt design integrated into the coverlet binds the whole mattress together increasing the systems ability to support a variety of patient loads safely and securely. Microfibre Foam for Enhanced Therapy The coverlet is constructed with a 5cm layer of hyperstretch open cell foam which in turn is coated with a microfibre material similar to that used in high performance athletic wear to wick moisture away from the body. The coverlet therefore not only insulates the patient from “Cell Chill” but also from any excess moisture buildup. The thin foam layer also assists in avoiding reperfusion injury in patients at high risk of sub-dermal vascular damage. Turbocharged Deflation The patented dynamulink cell design uses elasticised members to transfer the power of inflating cells to force down the deflating sets. This alternately removes almost all interface pressure under nearly 80% of the patient’s body The at risk heel area is completely elevated for nearly 30% of the alternation cycle. This unique cell design allows cell pairs to naturally remain upright when normal cells deform or collapse under patient weight. Sacrum Heel 35 30 25 Pressure in mmHg Industry Leader Theraflow 20 15 0 10 1 5 Pressure Release Performance Comparisons Patient Age: 42, Sex: Male Weight: 90kg Graphs show pressure release section of alternation cycle. 2 3 4 5 Time (Mins) 6 7 1 2 3 4 5 6 7 Time (Mins) 8 9 10 Theraflow Authorised Distributor: ™