a gold standard in Q-Switched technology
Transcription
a gold standard in Q-Switched technology
a gold standard in Q-Switched technology Superior Reliability MedLite C6’s proven Electro Optic Q-Switched technology enables fast and efficient treatments on all skin types for a broad range of applications. 32 .8 MILLION Aesthetic laser treatments expected in 2017 worldwide1 8 $ .9 BILLION In fees worldwide in 2017 for aesthetic laser treatments1 Medlite C6 Q-Switched Nd:YAG laser features proven PhotoAcoustic Technology and multiple wavelengths for efficient, reproducible results on all skin types. Melasma Epidermal and Dermal Pigment Skin Resurfacing Wrinkles Acne Scarring Tattoo Removal Proven Reliability • Medlite C6 is considered globally as the “gold standard” Q-switched laser with an industry-leading number of peerreviewed publications supporting its track record for success and clinical efficacy. • High peak power, and short pulse duration result in PhotoAcoustic action to shatter the target chromophore while minimizing harm to surrounding tissue • True flat-top beam profile delivers high energy evenly over the skin’s surface significantly reducing potential side-effects Consistent, reproducible results • Homogeneous flat-top beam profile is free of hot spots for more uniform treatment • Consistent depth of penetration for predictable results Uniform Heat Signature Flat Top Beam High Peak Power Optional Features MultiLite™ Dye Handpieces Extend the wavelength capabilities of the laser to include 585 nm and 650 nm for the treatment of tattoos and pigmented lesions. 532Lite™ Handpiece Provides very low fluences at smaller spot sizes (2 mm) for treatment of pigmented lesions. For more information visit cynosure.com/Medlite The Proof is in the Patients. Before After 8 Tx Courtesy of N. Polnikorn, MD. Before After Multiple Tx Before After 9 Tx Before After 1 Tx Courtesy of B. Saal, MD. Courtesy of T. Tu, MD. Courtesy of H. Shin, MD. System Type Wavelength Nd:YAG 1064 nm Pulse Width 532 nm 585 nm* 5–20 nsec Maximum Fluence Per Spot Size 8 mm 2.0 J/cm2 6 mm 3.5 J/cm2 4 mm 8.0 J/cm2 3 mm 14 J/cm2 2 mm — — — — Maximum Rep Rate Dye Impregnated Polymers <7 nsec — 1.4 J/cm2 3.2 J/cm2 5.6 J/cm2 12 J/cm2 — — — 10 Hz 650 nm* — — — — 8.0 J/cm2 6.0 J/cm2 4.0 J/cm2 2.0 J/cm2 — — — — 5.1 J/cm2 3.8 J/cm2 2.5 J/cm2 1.3 J/cm2 1.1 J/cm2 2.4 J/cm2 2 Hz 1 Hz 10 Hz Red Electrical Requirements 220 V, Single Phase, 9 Amp or 110 V, 15 Amps Weight 532 nm* 5–20 nsec Aiming Beam Size (H x W x D) 532 Lite — — — — — — 44.5" x 12" x 28.5" (113 cm x 30.5 cm x 72.5 cm) 128 lbs (58 kg) * Optional Handpieces SOURCES 1 Medical Insight, Inc. January 2013 CAUTION VISIBLE AND INVISIBL WHEN OPEN. AVOID EY TO DIRECT OR SCA ENERGY: PULSE WIDTH: WAVELENGTH: AIMING BEAM: IEC60825-1 : 5 Carlisle Road Westford, Massachusetts 01886 USA TELEPHONE 978 256 4200 TOLL FREE 800 886 2966 www.cynosure.com Cynosure, Inc. owns exclusive rights to photography. Use of photography without written permission of Cynosure is prohibited. Cynosure and Medlite are registered trademarks of Cynosure, Inc. ConBio is a trademark of Cynosure, Inc. ©2015 Cynosure, Inc. CAUTION - CLASS 4 VISIBLE AND INVISIBLE LASER RADIATION WHEN OPEN. AVOID EYE OR SKIN EXPOSURE TO DIRECT OR SCATTERED RADIATION. ENERGY: 1 J MAX PULSE WIDTH: < 20 ns WAVELENGTH: 1064, 532 nm 650, 585 nm AIMING BEAM: 650nm < 1mw cw IEC60825-1: 2007 921-0268-000 Rev 4 02/15 Corporate Headquarters
Similar documents
MedLite C6 Product Brochure
Courtesy of Tran Thi Anh Tu, MD Cosmetic & Laser Surgery Clinic, HCMC, Vietnam
More information