Technical dokumentation
Transcription
Technical dokumentation
21062012-GB TECHNICAL DOCUMENTATION Treviso with exchanger 21062012-GB TECHNICAL SHEET of the fireplace stove Treviso with exchanger Suitable fuel: As concerns suitable fuel to be employed, see the chapter 2.2 Fuel in the General Manual of Operation. Dimensions of the fire box Proper operation: As concerns the proper and safe operation of the fireplace stove, see the chapters 2. Description of the combustion process and 5. Operating instructions in the General Manual of Operation. The loop cover on the heat exchange unit is removable and you can replace it with a cooling loop unit. Fire-clay Dimension Goods No. No. 1 2 3 4 5 30x220x230 30x61x260 30x250x330 30x70x220 30x64x280 0331415005501 0331415005502 0050100350005 0332015005505 0050101640005 Breakdown of fire-brick lining TECHNICAL DESCRIPTION: Pos. Name 1 Base 2 Fuel bunker 3 Ash pan 4 Cast-iron grate 5 Smoke flue neck 6 Fire-box door 7 Lever lock of the fire-box door 8 Refractory glass 9 Controller of primary air 10 Controller of secondary air 11 Intake of secondary air 12 Tertiary air output 13 Protection 14 Lip - fixed 15 Heat exchanger 16 Upper mantelpiece/green 16 Upper mantelpiece/brown 16 Upper mantelpiece/honey cake 16 Upper mantelpiece/ivory 16 Upper mantelpiece/cappuccino 16 Upper mantelpiece/cream 17 Fireplace tile–side - right/green 17 Fireplace tile–side - right/brown 17 Fireplace tile–side - right/honey cake 17 Fireplace tile–side - right/ivory 17 Fireplace tile–side - right/cappuccino 17 Fireplace tile–side - right/cream 18 Fireplace tile–side - left/green Goods No 0332015006151 0417015115600 0020100130005 0332015005300 0081010080005 0332015005304 0082010030005 0332015005009 0332015005008 0332015006100 0332015006102 0332015026102 0332015036102 0332015056102 0332015066102 0332015076102 0332015006101 0332015026101 0332015036101 0332015056101 0332015066101 0332015076101 0332015106100 Pos. 18 18 18 18 18 19 19 19 19 19 19 20 21 22 23 24 25 26 27 28 29 30 Name Fireplace tile – side - left/brown Fireplace tile – side - left/honey cake Fireplace tile – side - left/ivory Fireplace tile – side - left/cappuccino Fireplace tile – side - left/cream Front tiles/green Front tiles/brown Front tiles/honey cake Front tiles/ivory Front tiles/cappuccino Front tiles/cream Top cover Rear cover Outlet of heating water G1" Intake of return water G1" Output of thermostat sensor for G ½” cooling loop Intake of cooling liquid G3/8" Outlet of cooling liquid G3/8" Coolant loop Well of air release valve Loop cover Loop sealing Sealing cord of the door 10 mm (2000 mm) Sealing cord of the glass 10 mm (1350 mm) Packing cord of exchanger 10x4 mm (3400 mm) Glass holder sealing rope 8x2 mm (580 mm) Sealing string for the upper cover 8x2 mm (1350 mm) Goods No 0332015026100 0332015036100 0332015056100 0332015066100 0332015076100 0332015006103 0332015026103 0332015036103 0332015056103 0332015066103 0332015076103 0332015006155 0332015006140 0332015005029 0332015006006 0332015006007 0040710100005 0040710100005 0040210040005 0040208020006 0040208020006 21062012-GB TECHNICAL INFORMATION INSTRUCTIONS FOR THE CONTROL OF COMBUSTION PROCESS: Output of the heating device Fuel 100% 33% 100% 33% 100% 33% Amount of fuel Primary air Secondary air 3 kg/h 1 kg/h open 100% open 30% open 100% open 50% Blockwood 2,7 kg/h 0,9 kg/h open 100% open 30% open 50% open 50% Ecological briquettes 2,4 kg/h 0,8 kg/h open 100% open 30% open 50% open 50% Coal briquettes TECHNICAL DATA: Achieved heat output (100%) Reduced heat output (33%) Output delivered by the stove body only Output available for heating of water Maximum stoking amount of the fuel Average temperature of combustion products behind the smoke flue neck Maximum mass flow of dry combustion products Energy efficiency Average concentration of CO2 Concentration of CO in combustion products at 13% O2 Množství spalovacího vzduchu při jmenovitém výkonu Tested in compliance with EN 13 240:2002/A2:2005 Blockwood 10,2 kW 3,4 kW 4,8 kW 5,4 kW 3 kg/h 100% 33% Tertiary air non-controllable non-controllable non-controllable Ecological Coal briquettes briquettes 10,7 kW 10,3 kW Height 3,5 kW 3,4 kW Width 5,1 kW 4,6 kW Depth 5,6 kW 5,7 kW Weight 2,7 kg/h 2,4 kg/h Diameter of the smoke flue 1100 mm 750 mm 486 mm 190 kg 150 mm 262 °C 276 °C 295 °C Maximum operating over-pressure of the exchanger 9,7 g/s 79,6 % 8,7 % 0,17 % m3/kg 6,6 g/s 85,2 % 13 % 0,08 % m3/kg 6,9 g/s 83,2 % 10,7 % 0,16 % m3/kg Water contents of the exchanger 17 l Recommended heat gradient (t output – t input) 75 - 60 °C Min. chimney stack draught in the smoke flue neck 12 Pa Heating capacity (middle heat losses ) at 10,7 kW cca.193 m3 Controllable output 3,4-10,7 kW Maximum temperature of output water 80 °C DIMENSIONED DIAGRAM OF THE FIREPLACE STOVE WITH INSTALLATION OF KNEE-PIECE FOR EXHAUST OF COMBUSTION PRODUCTS, DELIVERED AS OPTIONAL ACCESSORY 0,3 MPa REAR VIEW OF THE EXCHANGER AND COOLANT LOOP (G1/2") (G1") (G1") (G3/8") (G3/8") 21062012-GB INSTALLATION OF THE COOLANT LOOP M8 6x 30 29 M8 6x 30 27 COOLING LOOP (to be supplied as special accessories) SAFETY THERMO VALVE (not included in the scope of the delivery)