Fastfloor Thermal Brochure

Transcription

Fastfloor Thermal Brochure
THERMAL
The ultimate thermal flooring system
THERMAL
Incorporating Springvale’s
Beamshield® Expanded
Polystyrene (EPS) Flooring
Block, our FASTFLOOR
THERMAL system is
the ultimate solution
for reducing thermal
bridging with no additional
insulation required.
In addition, FASTFLOOR
THERMAL is quick, easy
to install and adds value
to your build. Suitable for
ground floors.
TOTAL FLOOR INSULATION
FASTFLOOR THERMAL provides
total floor insulation, reducing thermal
bridging with no additional insulation
required.
INCREASED PRODUCTIVITY
These lightweight blocks are quick
and easy to install with no special skills
required – increasing speed of build.
FIRE CLASSIFICATION
This system has a Euroclass B
classification.
THERMAL PERFORMANCE
FASTFLOOR THERMAL delivers
excellent U-values as low as 0.10W/mK
and can significantly improve SAP ratings
VERSATILE
FASTFLOOR THERMAL can be installed
in inclement weather and is maintenance,
rot and damp free.
FASTFLOOR THERMAL
for ultimate thermal
performance with no
additional insulation required
6
1
2
1 Telescope Ventilator
2DPC
3 FASTFLOOR Beam
4Beamshield®
5 Coursing slips
6Screed
3
5
4
PRODUCT PROPERTIES
CONCENTRATED LOAD
(kn)
THERMAL
CONDUCTIVITY
(W/mK)
WATER VAPOUR
DIFFUSION FACTOR
(litres)
DENSITY
(kg/m3)
BEAMSHIELD® PLUS WHITE
1.5
0.038
20-40
15-16
BEAMSHIELD® PLUS PLATINUM
1.5
0.030
20-40
16-17
PRODUCT
U-VALUE PERFORMANCE EXAMPLES
PRODUCT
BEAMSHIELD® PLUS
WHITE 228MM
BEAMSHIELD PLUS
WHITE 244MM
®
BEAMSHIELD PLUS
PLATINUM 244MM
®
BEAMSHIELD® PLUS
PLATINUM 282MM
BEAMSHIELD® PLUS
PLATINUM 331MM
BEAMSHIELD® PLUS
PLATINUM 378MM
P/A
RATIO
U-VALUE
(W/m2K)
SINGLE BEAM
INSULATION TYPE
(K=W/mK)
0.50
0.20
NONE REQUIRED
0.60
0.21
NONE REQUIRED
0.70
0.22
NONE REQUIRED
0.50
0.19
NONE REQUIRED
0.60
0.19
NONE REQUIRED
0.70
0.20
NONE REQUIRED
0.50
0.16
NONE REQUIRED
0.60
0.17
NONE REQUIRED
0.70
0.20
NONE REQUIRED
0.50
0.14
NONE REQUIRED
0.60
0.14
NONE REQUIRED
0.70
0.14
NONE REQUIRED
0.50
0.11
NONE REQUIRED
0.60
0.12
NONE REQUIRED
0.70
0.12
NONE REQUIRED
0.50
0.10
NONE REQUIRED
0.60
0.10
NONE REQUIRED
0.70
0.10
NONE REQUIRED
* U Values based on nominal 600mm and nominal 300mm centres at a ratio of 4 to 1
72mm
THERMAL BRIDGING
In addition to the heat loss through the floor, expressed
by the U-value of the floor, considerable heat is also lost
at the junction with the external wall. This is described as
thermal bridging.
150mm
Dealing effectively with thermal bridging can benefit the
SAP energy calculations up to 12% for a typical semidetached house. Up to 2% of this can be attributed to
the ground floor junction with the external wall. The use
of FASTFLOOR THERMAL can help to vastly reduce
this heat loss. As the thermal bridging can vary quite
considerably dependent upon the construction and
U-value of the floor and walls, the thermal bridging
values (psi values) are calculated for each project.
Further information can be provided upon request.
135mm
TYPICAL FASTFLOOR THERMAL DETAIL
1
30mm perimeter strip
2
Cavity wall insulation to overlap
base of beam
3
Aircrete trench block
4
Lightweight blockwork
1
FGL
2
Beamshield® units
150
5
5DPC
6
150mm MIN
MIN 150 MM VOID
3
4
6
V1/2016
To find out more about FASTFLOOR and the best solution for your project
call 0333 003 4701 or email fastfloor@tarmacbp.co.uk
TARMAC.COM
©2016 Tarmac Building Products Limited.
In association with Beamshield®