Rex astronomical time switches
Transcription
Rex astronomical time switches
Our time controlling solutions for your applications Rex - digital time switches AlphaRex NEW 047 61 047 72 According to VDE 631-1 and 631-2-7, IEC 60 730-1 and 60 730-2-7, EN 60 730-1 and 60 730-2-7 • with text based programming concept • Selectable languages: English, German, Frensh, Italian, Spanish and Dutch • fast programming due to selection of pre-set groups of days Mo-Su, Mo-Fr, Sa-Su and individual selection of days • easy programming with PC using Legrand software and data key • a program consists of an ON and OFF time and their assignment to certain days • Backup on data key possible • with additional fuctions: - holiday program - random function - pulse funktion (only 1 channel) with pulse duration of 1 sec up to 59 min, 59 sec. and 84 start times (NOT D22 and D21s) - hour counter for max. 65 535 hours. • backgroundlighting for display and buttons • running reserve of 6 years for date and time • programs are stored in a EEPROM • programs are shown as a weekly matrix on the display • automatic summer-/wintertime change (daylight saving) • Precision +/– 0,2 sec/day • manual switching • lead sealable cover, even with inserted data key Reference AlphaRex D21 weekly time switch, 1 channel 047 61 604 760 047 63 230 V, 50/60 Hz 120 V, 50/60 Hz 24 V, AC/DC AlphaRex D22 weekly time switch, 2 channels 047 71 604 770 604 772 230 V, 50/60 Hz 120 V, 50/60 Hz 24 V, AC/DC AlphaRex D21s weekly time switch, 1 channel with control input and delay 604 768 604 767 604 769 2 230 V, 50/60 Hz 120 V, 50/60 Hz 24 V, AC/DC 047 73 Reference Accessory 047 72 Data key •with the datakey, it is possible to transfer programs into the time switch. Select the data key fuction on “READ” on the time switch • the data key can be programmes on a PC • using the data key function “WRITE”, programs can be transfered to the data key. It allows to easily copy programs from one time switch to another one. It can also be used as a backup. • one data key allows to save 1 complete time switch program (56 ON/OFF) 047 73 USB-adapter • to read and write data keys on a PC • software included • connection via USB-port • System requirements: Windows®2000, Windows®ME, Windows®XP and Windows®98 second Edition, 10 MB free disc space • serial adapter on demand 057 91 Deposit box for data keys - to store data keys in a installation cabinet LIGHT CONTROL >>> Rex - Astronomical time switches AlphaRex Astro Rex astronomical time switches Easy control of light based on the calculation of sunrise and sundawn, with no need of installing a light sensor! ■ Comfort and safety The time switch calculates the daily times of sunset and sunrise. At sunset the AstroRex will switch the lights ON and at sunrise the AstroRex will turn the lights OFF. 047 64 According to VDE 631-1 and 631-2-7, IEC 60 730-1 and 60 730-2-7, EN 60 730-1 and 60 730-2-7 • with text based programming concept • Selectable languages: English, German, Frensh, Italian, Spanish and Dutch • fast programming due to selection of pre-set groups of days Mo-Su, Mo-Fr, Sa-Su and individual selection of days • easy programming with PC using Legrand software and data key • a program consists of an ON and OFF time and their assignment to certain days • Backup on data key possible • with additional fuctions: - holiday program - hour counter for max. 65 535 hours. • backgroundlighting for display and buttons • running reserve of 6 years for date and time • programs are stored in a EEPROM • programs are shown as a weekly matrix on the display • automatic summer-/wintertime change (daylight saving) • Precision +/– 0,2 sec/day • manual switching • lead sealable cover, even with inserted data key • Calculation of sunrise and sunset by programming date, time and local coordinates. • No light sensor needed! • To save energy, a switching off at night is programmable. • The switcing On and OFF times can be adjusted asymetricaly for +/- 120 minutes. • The control input enables the activation of the time switch irrespective to the program. (NOT D22 Astro!) Reference AlphaRex D21 Astro weekly time switch, 1 channel ■ Energy saveing on request 047 64 047 65 047 66 To save energy, it is possible to program an OFF and an ON time at night. AlphaRex D22 Astro weekly time switch, 2 channels 047 67 047 68 047 69 ■ As flexible as you need it Even when the lights are OFF due to a OFF-program at night, it is possible to turn the lights on by useing the control entry. 230 V, 50/60 Hz 120 V, 50/60 Hz 24 V, 50/60 Hz 230 V, 50/60 Hz 120 V, 50/60 Hz 24 V, 50/60 Hz Remark: you can program the AlphaRex Astro useing the datakey 04772 and the programming software AlphaSoft! (see page 2) Examples for typical applications > shop window illumination > Illumination of private and public buildings > Bill board illumination 3 Rex - digital time switches Rex - digital time switches MicroRex / MicroRex Plus Frontpanel and wallmounting MaxiRex Plus NEW NEW 037 00 604777 496 82 According to IEC 730-1, EN 60730-1, VDE 0631-1, IEC 730-2-7, EN 60730-2-7, VDE 0631-2-7 Weekly time switch for front panel installation or surface mounting According to EN 60730-1 and EN 60730-2-7 Digital weekly DIN rail mounting time switch 1 program consists of 1 ON and 1 OFF time and the allocation of any day of the week or a combination of days and the selected channel (2 channel version). example: 1. prog.: ON 07:00h 2. prog.: ON 16:00h 3. prog.: ON 10:00h OFF 08:15h Mo-Fr OFF 20:15h Mo-Su OFF 15:15h Fr CH1 CH2 CH1+2 Additional features: • manual override (ON/OFF): permanant ON or OFF • automatic override (ON/OFF): actual program will be inversed (ON->OFF, OFF->ON) till next programmed ON time • automatic changing of summer-/winter time (daylight saveing) • running reserve of 6 years or 1 program consists of 1 ON and 1 OFF time and the allocation of any day of the week a combination of days and the selected channel. (2 channel version) Example: 1. prog.: 2. prog.: 2. prog.: ON 07:00h ON 16:00h ON 10:00h Reference 604 774 604 773 604 775 230 V, 50/60Hz 120 V, 50/60Hz 24 V, AC/DC MicroRex D22 Plus 2 channels 4 604 777 604 776 604 778 230 V, 50/60Hz 120 V, 50/60Hz 24 V, AC/DC 037 00 037 93 MicroRex D11 1 channel, 1 module 230 V, 50/60 Hz 120 V, 50/60 Hz Mo-Fr Mo-Su Fr CH1 CH2 CH1+2 Additional features: •manualoverride (ON/OFF): permanent ON or OFF • automatic override (ON/OFF): actual program will be inversed (ON -> OFF, OFF ON)till next programmed on time. • automatic changing of summer-/winter time (daylight saveing) • running reserve: 6 years Reference MicroRex D21 Plus 1 channel OFF 08:15h OFF 20:15h OFF 15:15h 496 81 496 83 496 85 MaxiRex D72/1 Plus 1 channel 230 V, 50/60 Hz 120 V, 50/60 Hz 24 V, 50/60 Hz 496 82 496 84 496 86 MaxiRex D72/2 Plus 2 channels 230 V, 50/60 Hz 120 V, 50/60 Hz 24 V, 50/60 Hz Rex - Light sensitive switches Rex - digital time switches MicroLux D / LuxoRex Rex 2000 modules 945 902 037 21 916 87 According to VDE 0631-1 and 0631-2-7, IEC 60 730-1 and 60 730-2-7, EN 60730-1 and 60730-2-7 • supplied with photo-electric cell housed in Plexo weatherproof box – IP 55 • Light sensitivity adjustable from 5 to 2000 Lux • controls equipment (lighting) according to the light level/time • accuracy of time switch: ± 2,5 seconds per day • 100 h working reserve • 7 day program (digital) • Manual advance/override • Max. distance between photo cell and switch 50 m • programming possibilities: • capability of 8 programs: 1 program consists of 1 “on” and 1 “off” time and the allocation of any day of the week or a combination of days. • possible combinations: - Mo - Fr (1-5) - Mo - Su (1-7) - any days of the week free programmable. • Example: 1. Prog. 2. Prog. 3. Prog. etc. 965 954 498 43 Designed to be integrated into an exicting controller, offering the programming concept FACE. • same concept for all models • easy, simple and quick programming • actual time, day of the week and installed program always at one glance • eternal memory thanks to EEPROM memory • atuomatic change of summer- and wintertime (daylight saveing) Technical details: • power supply: 5 V, DC • running reserve for actual time: super cap or lithium battery • program stored in EEPROM • power consumption: approx. 3 mA • working temperature: -20°C - +55°C Reference on 7:00 on 16:00 on 10:00 off 8:15 off 20:15 off 16:15 Mo - Fr (1-5) Mo - Su (1-7) Fr (5) 945 902 Rex 2000 modules 1 channel, 7 days 8 ON/OFF per day 945 903 2 channels, 7 day 4 ON/OFF per channel and day 945 904 1 channel, 7 day, radio controlled 8 ON/OFF per day 945 905 1 channel, 7 day, with control input and delay time 8 ON/OFF per day 965 954 Accessory frame, fit for all Rex2000 modules Reference MicroLux D21 weekly time switch, 1 channel • Min. switching step: 1 minute • Max. distance between photo cell and switch 50 m 037 21 230 V, 50/60 Hz According to VDE 0632-1 and 6032-2-1 and 6032-2-3, IEC 60 669-1, 60669-2-1 and 60669-2-3, EN 60 669-1, 60 669-2-1 and 60 669-2-3 • Advanced design • Light sensor integrated • ample space for connecting the cable • The LuxoRex can be combined with a time switch for more economical use. • adjustable continuously from 5 . . . 1000 Lux • switching delay of 2 min at “on” and “off” action LuxoRex daily light sensitive switch 498 43 230 V, 50/60 Hz 916 87 Accessory Plexo 55 supplementary photocell for special installations requiring more than 1 sensor 5 Rex - analogue time switches Rex-analogue time switches MicroRex - 3 modules for rail-mounting MicroRex - 1 module for rail-mounting NEW 037 53 047 53 037 43 According to IEC 730-1, EN 60730-1, VDE 0631 part 1, IEC 730-2-7, EN 60730-2-7, VDE 0631part 2-7 According to IEC 730-1, EN 60730-1, VDE 0631 part 1, IEC 730-2-7, EN 60730-2-7, VDE 0631 part 2-7 Analogue 24 hour and 7 day time switches for DIN rail. Hour and minute hands can be turned clockwise and counter-clockwise, therefore easy and quick change of summer- to wintertime and wiseversa. • manual override switch Analogue 24 hour and 7 day time switches for DIN rail. • manual override switch Reference MicroRex S11 1 hour program, synchronous motor Reference MicroRex T31 24 hour program, synchronous motor 037 52 925 436 037 56 037 65 230 V, 50 Hz 230 V, 60 Hz 120 V, 50 Hz 120 V, 60 Hz MicroRex W31 7 day program, synchronous motor 037 54 037 57 037 66 230 V, 50 Hz 120 V, 50 Hz 120 V, 60 Hz MicroRex QT31 24 hour program, quartz controlled motor (with running reserve) 037 53 037 51 926 420 230 V, 50/60 Hz 120 V, 50/60 Hz 9-48 V, AC/DC MicroRex QW31 7 day program, quartz controlled motor (with running reserve) 037 55 037 58 926 113 230 V, 50/60 Hz 120 V, 50/60 Hz 9-48 V, AC/DC Accessory 037 49 Kit for wallmounting, including base plate and terminal cover Analogue time switch with automatic summer-/winter time change (daylight saving), for DIN-rail mounting with manual override switch. • automatic adjustment of actual time as soon as connected to tension • automatic summer-/winter time change (daylight saveing) • Accuracy of +/- 0,2 sec/day • Manual override: ON-AUTO-OFF • sealable cover (Actually available for use in central Europe only!) NEW MicroRex T31 su/wi 047 53 230 V, 50/60 Hz 047 58 230 V, 50/60 Hz MicroRex W31 su/wi 6 03742 230 V, 50 Hz MicroRex T11 24 hour program, synchronous motor 037 30 910 404 037 31 230 V, 50 Hz 230 V, 60 Hz 120 V,60 Hz MicroRex QT11 24 hour program, quartz controlled motor (with running reserve) 037 40 037 41 916 406 230 V, 50/60 Hz 120 V, 50/60 Hz 12 V, AC/DC MicroRex W11 7 day program, synchronous motor 037 43 910 101 037 45 230 V, 50 Hz 230 V, 60 Hz 120 V, 60 Hz MicroRex QW11 7 day program, quartz controlled motor (with running reserve) 037 44 037 46 230 V, 50/60 Hz 120 V, 50/60 Hz Rex - analogue time switches Frontpanel and wallmounting MaxiRex 497 50 497 52 497 58 According to IEC 730-1, EN 60730-1, VDE 0631 part 1, IEC 730-2-7, EN 60730-2-7, VDE 0631 part 2-7 Analogue daily or weekly time switch for front panels, DIN rail mounting and surface mounting • With manual override switch (ON/OFF/AUTOMATIC OPERATION). • Hands can be moved clockwise or counter-clockwise (except for MaxiRex TS), therefore, e. g. summer and winter time can be adjusted easily. • Accessories for the assembly do not belong to the delivery range, but have to be ordered separately. • Voltage tolerance: ± 10 % • 3 position changeover switch • With manual override • With 72 x 72 mm display to DIN EN 50 022 partC Reference Reference MaxiRex W - 7 day, without running reserve 497 52 497 32 230 V, 50 Hz 120 V, 60 Hz 497 56 497 36 924 131 230 V, 50/60 Hz 120 V, 50/60 Hz 24 V, AC/DC 497 53 497 33 230 V, 50 Hz 120 V, 60 Hz 497 57 497 37 924 249 230 V, 50/60 Hz 120 V, 50/60 Hz 9-48 V, AC/DC MaxiRex QW - 7 day, with running reserve MaxiRex T - 24 h, without running reserve 497 50 497 60 497 30 230 V, 50 Hz 230 V, 60 Hz 120 V, 60 Hz MaxiRex WT - 7 day / 24 h, without running reserve MaxiRex QWT - 7 day / 24 h, with running reserve MaxiRex TT - 24 h / 24 h, without running reserve 497 51 923 517 497 31 230 V, 50 Hz 230 V, 60 Hz 120 V, 60 Hz Accessories MaxiRex QT - 24 h, with running reserve 497 54 497 34 924 434 230 V, 50/60 Hz 120 V, 50/60 Hz 9-48 V, AC/DC 498 32 Clip-on support frame for fascia mounting 044 09 DIN-rail adaptor MaxiRex QTT - 24h / 24 h, with running reserve 497 55 497 35 924 531 230 V, 50/60 Hz 120 V, 50/60 Hz 9-48 V, AVC/DC MaxiRex TS - 24 h / 60 min, without running reserve 497 58 923 623 497 59 230 V, 50 Hz 230 V, 60 Hz 120 V, 60 Hz 7 Rex - analogue time switches Rex - analogue time switches Frontpanel and wallmounting EconoRex MaxiRex 30A NEW 499 81 499 83 499 83 According to IEC 730-1, EN 60730-1, VDE 0631-1, IEC 730-2-7, EN 60730-2-7, VDE 0631-2-7 Compact analogue daily or weekly time switch for front panels and surface mounting • with manualoverride • with 72 x 72 mm display confirm to DIN EN 50 022 part C Reference 499 81 499 88 499 80 EconoRex BTAP 24 h, without running reserve 230 V, 50 Hz 230 V, 60 Hz 120 V, 60 Hz 499 85 499 79 EconoRex BQTAP 24 h, with running reserve 230 V, 50/60 Hz 120 V, 50/60 Hz 499 91 912 432 499 93 EconoRex BWAP 7 day, without running reserve 230 V, 50 Hz 230 V, 60 Hz 120 V, 60 Hz 499 92 912 440 EconoRex BQWAP 7 day, with running reserve 230 V, 50/60 Hz 120 V, 50/60 Hz According to EN 50022, EN 55014-1, EN 55014-2, IEC 60730-1, EN 60730-1, VDE 0631-1, IEC 60730-2-7, EN 60730-2-7, VDE 0631-2-7. Robust analogue daily and weekly time switch with REAL 30 Amps switchting capacity, for rail mounting and wall mounting. The MaxiRex 30A is our perfect solution to control your special applications with heavy loads like: • the lighting of commercial boards / sign boards • water heaters • air cons • hydrochlorinators • heating / ventilation systems • post laterns • blowers • pool heaters • electric fences • filters, pumps and conveyers Ref. 649 961 649 962 649 963 MaxiRex T 30A Daily time switch, without running reserve 230V, 60Hz 230V, 50Hz 120V, 60Hz 649 964 649 965 MaxiRex QT 30A Daily time switch, with 100h running reserve 230V, 50/60Hz 120V, 50/60Hz 649 968 649 969 649 970 MaxiRex W 30A Weekly time switch, without running reserve 230V, 60Hz 230V, 50Hz 120V, 60Hz 649 966 649 967 MaxiRex QW 30A Weekly time switch, with 100h running reserve 230V, 50/60Hz 120V, 50/60Hz Time switch modules with flat plugs for panel mounting (without accessories) EconoRex MT 24 h, without running reserve 499 83 499 82 230 V, 50 Hz 120 V, 60 Hz EconoRex MQT 24 h, with running reserve 499 86 499 78 230 V, 50/60 Hz 120 V, 50/60 Hz EconoRex MW 7 day, without running reserve 499 96 499 98 230 V, 50 Hz 120 V, 60 Hz EconoRex MQW 7 day, with running reserve 499 94 499 95 230 V, 50/60 Hz 120 V, 50/60 Hz Accessories 495 94 8 Wall mounting kit for EconoRex M includes base plate with terminas and terminal cover Accessory Terminal cover Rex - analogue time switches Rex - analogue time switches defrost time switches PolarRex defrost time switches MicroRex 31F new picture!!! 499 26 037 59 037 49 According IEC 730-1, EN 60730-1, VDE 0631-1, IEC 730-2-7, EN 60730-2-7, VDE 0631-2-7. According to IEC 730-1, EN 60730-1, VDE 0631 part 1, IEC 730-2-7, EN 60730-2-7, VDE 0631part 2-7 The time switch has a 24h dial and one (1 channel) or two (2 channel) continuesly adjustable shorttime programs, which can repeated several times in 24h. The program’s duration has to be adjusted with a button which is dedicated to a specific channel. The start of the program has to be set on the dial by pulling a segment on the desired time. The shortest duration between 2 programs is 30 min. The shorttime program can be repeated up to 48 times in 24h. The beginning, the duration and the number of the programs can be changed easily without any accessories. Analogue 24 hour time switches for DIN rail and wall mounting without manual override switch. Hour and minute hands can be turned clockwise and counter-clockwise, therefore easy and quick change of summer- to wintertime and wiseversa. • sealable cover and terminalcover Reference MicroRex T31F 24 hour, synchronous motor Different typs of fixing: • DIN EN 500 22 • wall mounting 037 59 MicroRex QT31F 24 hour, quartz controlled motor (with running reserve) Reference Defrost time switches without running reserve PolarRex KT 24 hour, 1 channel 499 20 230 V, 50 Hz 037 60 230 V, 50/60 Hz Accessories 037 49 Wall mounting kit including terminal cover 230V, 50Hz PolarRex KKT 24 hour, 2 channel 499 26 230V, 50Hz Defrost time switches with running reserve PolarRex QKT 24 hour, 1 channel 499 21 A13 475 230V, 50/60 Hz 120 V, 50/60 Hz PolarRex QKKT 24 hour, 2 channels 499 27 230 V, 50/60 Hz 9 Rex - staircase timers Rex - staircase timers Rex Plus-program Rex Plus-program NEW 037 01 047 07 047 04 According to IEC 669-1, EN 60669-1, VDE 0632 part ,IEC 669-1-2, EN 60669-2-1, VDE 0632 part 2-1,IEC 669-2-3, EN 60669-2-3, VDE 0632 part 2-3 • Voltage life: 100% • Electronic • Exact time setting • Extremely quiet • Only one tool is necessary for adjustment and connection • By means of manually-operated switch you can change over from permanent light to automatic light • Glow lamp current 50 mA at the maximum • Minute light can be switched on at night at any time • Range of temperature between -10 °C and +55 °C • Switching contact: 1 make contact µ, 16 A 497 83 According to IEC 669-1, EN 60669-1, VDE 0632 part ,IEC 669-1-2, EN 60669-2-1, VDE 0632 part 2-1,IEC 669-2-3, EN 60669-2-3, VDE 0632 part 2-3 Reference 497 83 497 81 037 01 230 V~ Rex800 Standard staircase timer with early warning function time switch 0,5-12 min. automatic 3-/4-wire connection, 16A/230V~, 50/60 Hz, 2000 W lamp load resistance/Halogen bulbs 230 V, 1000 VA fluorescent lamps, serial compensation 120 VA fluorescent lamps, parallel compensation Parallel compensation: C <= 100µF at the maximum 047 02 230 V~ Rex 800 connect Standard staircase timer time switch 0,5-12 min. automatic 3-/4-wire connection, 16A/230V~, 50/60 Hz, 2000 W lamp load resistance/Halogen bulbs 230 V, 1000 VA fluorescent lamps, serial compensation 120 VA fluorescent lamps, parallel compensation Parallel compensation: C <= 100µF at the maximum 047 06 230 V~ Rex800 multi Multi-fuctionlal staircase timer: • standard staircase timer • staircase timer with pre-warning fuction • staircase timer with long time function (1h) • staircase timer with early warning and long time fuction • disconnectable time relais • disconnectable time relais with early warn function • electronic relais lighting time switch 0,5-12 min. for all driving voltages from 8-230 V/AC DC 3-/4-wire connection, 16A/230V~, 50/60 Hz, 2000 W lamp load resistance/Halogen bulbs 230 V, 1000 VA fluorescent lamps, serial compensation 120 VA fluorescent lamps, parallel compensation Parallel compensation: C <= 100µF at the maximum maximum length of trip lines: 100 m 047 04 10 Rex 600 plus • for wall mounting • 3 wire connection only • for replacement purposes only - not allowed for new installations • 0,5 - 10 min. • 800 W lamp load resistance/Halogen bulbs 230 V 230 V~ 120/230 V, 50/60 Hz Rex 900 plus Reference Rex EM Plus electronic staircase timer, 3-/ 4-wire connection, manual switch for automatic/permanently ON, resettable glow lamp current max. 25 mA 230 V~ 037 03 DETAILS FOLGEN!!!!! 037 03 230 V~ Rex - analogue time relays Rex - electronic time relay Dufty Rex 492 30 047 00 047 42 047 44 047 45 According to VDE 0631-1 and 0631-2-7, EN 60 730-1 and 60 730-2-7 Electronic OFF delay relay Application: To control single timer functions like: illumination, ventilation, automation, signalisation, control systems . . . • sealable cover • Lexic design • supply voltage: 12 V...230 V AC • 100% ED • resettable • to be mounted behind switch intoflush mounting box Ø 55 mm. Application: • off delay time relay to be used for ventilation • After switching off the illumination the relay still will run the pre-programmed time of 3, 6 or 12 minutes Reference 047 00 Star-Delta relay Reference DuftyRex 047 40 ON-delay relay 492 30 230 V 50/60 Hz Control input Y1 Contact 047 41 OFF-delay relay Control input Y1 Contact 047 43 Clock generator relay (impulse starting) Control input Y1 Contact 047 45 Impulse former relay Control input Y1 Contact 047 42 Flashing relay Control input Y1 Contact 047 44 Multifunctional relay additionally to the a.m. functions (except the flashing relay) the multifunctional relay offers you the following functions: ON/OFF delay Control input Y1 Contact Flasher (impulse starting) Control input Y1 Contact Flasher (off-time starting) Control input Y1 Contact Passing contact Control input Y1 Contact Additive ON delay Control input Y1 Contact Additive fleeting ON Control input Y1 Contact 11 Hour counters Hour counters Frontpanel-, rail-, flush-mounting ContaRex Rail-mounting Rex 2000 HC2 495 55 495 98 According to IEC 1010-1, EN 61010-1, VDE 0411 part 1 • form: 48 x 48 mm, IP 40 • upgrading frame 55 x 55 included (48 x 48 mm version) • AC-version: = 0... 99999,99 h • DC-version: = 0... 999999,9 h • weight abt. 75 g • frontpanel mounting 907 238 046 94 According to IEC 1010-1, EN 61010-1, VDE 0411 part 1 Analogue modular hour run indicator in LexicTM design for DIN rail mounting • Easy and quick fixing on any DIN rail by using the 2 locking clamps • sealable cover Reference Rex2000 HC2 Reference ContaRex 48 x 48 frontpanel 495 52 495 53 495 54 495 55 495 57 495 59 495 60 24 V, 50 Hz 120 V, 50 Hz 120 V, 60 Hz 230 V, 50 Hz 230 V, 60 Hz 400 V, 50 Hz 10 - 80 V, DC ContaRex 48 x 48 DIN rail mounting 495 62 230 V, 50 Hz • form: round, Ø 80 mm, IP 67 • protected against vibrations by a rubber buffer ring • DC-version: 0...99999,9 h • weight abt. 145 g • frontpanel mounting ContaRex round, Ø 80 mm 495 63 10...80 V ±10% • form 36 x 24 mm, IP 40 • AC-version: 0...99999,99 h • flush mounting ContaRex 36 x 24 mm 907 238 907 239 907 240 230 V, 50 Hz 230 V, 60 Hz 24 V, 50 Hz 495 98 495 97 Frame 72 x 72 mm Frame 55 x 55 mm Accessories 12 DC 046 91 046 94 046 93 046 92 046 91 046 90 230 V, 50 Hz 230 V, 60 Hz 120 V, 60 Hz 24 V, 50 Hz 12-36 V DC for example Rex - digital :time xxxxxxx switches for example : xxxxxxx xxxxxxxx AlphaRex xxxxxxxx ■ Technical data Typ AlphaRex D21 No. of modules (17,5 mm) Channels Running reserve Switching step Min. switching time Accuracy Switching capacity • Resitive 230 V~cos ϕ=1 • Incandescent lamp 230 V • Inductive 230 V~cos ϕ=0,6 Contact Programs1) Impulse starting times Impulse duration Operating temperature Protection AlphaRex D22 1) A program consists of an ON and OFF time and the assigned day(s). 2 1 2 6 Jahre 1 min 1 min 0,2 sek/ Tag 16 A~ 8 A~ 10 A~ 1 SPDT 2 SPDT 56 28/channel 84 min 1 sek max 59 min, 59 sek -20 °C……+55 °C IP20 ■ Wiring diagram AlphaRex D21 AlphaRex D22 ■ How it works Menu selection, one step back, pressing >1s = back to main display MENÜ Confirmation of selection and parameters OK – + Selection in the menu, adjusting parameter and selection of the channel (2 channel version only!) 13 for xxxxxxx Rexexample - digital :time switches for example : xxxxxxx xxxxxxxx AlphaRex xxxxxxxx n Brief description of the programming possibilities • Text based programming The AlphaRex uses clear text to guide you through the options and the programming. Every step is clearly displayed and the selected function is flashing. The integrated background lighting for display and buttons allows easy programming even at bad lighting conditions. • Selection language Using the “MENU”-button, allows to select the requested language. Default language is english. Time, date, summer-/wintertime. The actual time (CET) and date have been pre-set in the factory. Default summer-/wintertimeis EU. Changes can be made by choosing “MENU” and “SET” • Programming A program consists of an ON and OFF time and the assigned day(s). Before setting the ON and OFF times, the requested days have to be selected: MONDAY-SUNDAY, MONDAY-FRIDAY, SATURDAY-SUNDAY or INDIVIDUAL. The INDIVIDUAL mode allows to select every single day of the week. It is also possible to program over midnight. • Relay function With „MENU“ and „FIUNCTION“ it is possible to change the relay possition. By default it is “AUTO”, the time switch switches at the programmed times. Additional selections are: „CONST ON“, „CONST OFF“ and „EXTRA“. With choosing „EXTRA“ the stored program will be inversed. When the next programmed switching time has been reached, the time switch returns to normal mode. • Holiday Selection the “HOLIDAY” function allows to set the start- and enddate of the holidays and has to be activated by selecting “ACTIVE”, or deactivate it by selecting “PASSIVE”. When the “HOLIDAY” function is activated, the stored program will be ignored during the selected days and replaced by “CONST ON” or “CONST OFF”. When holiday is over, the AlphaRex return to default mode. • Data key When the time switch is connected to the supply, the data key activates automaticaly the “DATA KEY” menu with the options “READ” and “WRITE”. “WRITE”: programs stored in the time switch will be copied into the data key. Eventually stored programs on the data key will be overwritten! “READ”: programs stored on the data key will be copied into the time switch. Eventually stored programs on the time switch will be overwritten. It is only possible to save 1 “time switch program” which consist of max. 56 ON/OFF (1 channel) or max. 84 ON (1 channel pulse) or max. 2 x 28 ON/OFF (2 channel) on the time switch and the data key. When inserting the data key without the time switch being conected to the supply, the “DATA KEY” menu will not appear automatically, but has to be selected manually! • Programming on the PC Next to the easy and text based programming directly on the time switch, it is also possible to do it on your PC by using the Legrand software and to transfer the program with the data key to the time switch. To save the PC-created programs on the data key, the USB-adapter has to be installed. System requirements: USB-port; Windows®98 second edition; Windows®2000; Windows®ME or Windows®XP, 10MB free disc space • Reset Pressing simultaneously on all 4 buttons for more than 2 seconds, will causes a deletion of all stored data. Language, time/date, summer-/wintertime and programs have to be reinstalled. 14 for Rex-light example controllers : xxxxxxx for example : xxxxxxx xxxxxxxx AstroRex-twilight time switch xxxxxxxx ■ Technical data Type AstroRex D21 No. of pitch units of 17.5 mm Number of channels Power reserve Switching increment Shortest switching time Accuracy Switching capacity • Ohmic 230 V~cos ϕ =1 • Filament lamp 230 V • Inductive 230 V~cos ϕ =0,6 Switch output Programs1) Control input with delay-time Operating temperature Type of protection AstroRex D22 2 1 2 1) Each program comprises a switchon and switch-off time and the associated on and off days or day blocks. 6 years 1 min 1 min 0,2 s/day 16 A~ 8 A~ 10 A~ 1 SPDT 2 SPDT 28 2 x 14 0 min – 23 h 59 min – –20 °C……+55 °C IP20 ■ Wiring diagrams AstroRex D21 AstroRex D22 ■ Functions MENÜ OK – Menu selection, back in menu Actuated > 1 second = operating display Confirm selection or adopt parameters + Select menu items or set parameters, also selection of channel in 2-channel time switch (channel 1 - channel 2) 15 for Rex-light example controllers : xxxxxxx for example : xxxxxxx xxxxxxxx AstroRex-twilight time switch xxxxxxxx ■ Basic settings Menu guidance The AstroRex guides the user through the programming and setup in plain English. Every step can be read off on the display; the momentarily active function is indicated by a flashing light. Integrated display and push-button illumination makes operation easier even in poor visibility. Select language The language can be selected via the "MENU" button. English is set on delivery. Time / date / summer time / winter time The time switch is set to the actual time and date by the manufacturer, as well as to the summer / winter time applicable in Europe. Times can be changed via "MENU" + "SET". Position (astro) The different daily sunrise and sunset times are calculated for the position programmed in the AstroRex. "GERMANY SOEST" is set on delivery. The actual position should be entered for optimum operation. This can be done in two ways: via "MENU", "SET" and "ASTRO" to the two options "POSITION" and "COORDINATES". "POSITION": The town and country closest to the position of use can be selected via this menu item. "COORDINATES": The coordinates of the actual location can be entered in this menu item if desired. coordinates and time zones can be found in the time zone map enclosed with every time switch. Information on Offset Time differences in relation to the calculated switching times can be set via "MENU", "SET", "ASTRO" and "OFFSET". The actual switching time can be offset by up to +/- 120 minutes in relation to the sunrise and sunset times by entering a time difference. This time is set separately for sunrise and sunset. t 1 0 0h 3 6 9 + max. ± 120min 12 15 18 21 + max. ± 120min 24h Example: If an offset of +30 minutes is entered, the time switch switches 30 minutes after sunrise and 30 minutes after sunset. If an offset of -30 minutes is entered, the time switch switches 30 minutes before sunrise and 30 minutes before sunset. Basic setting via PC and data key All the basic settings described above, except the actual time and date, can be programmed with the Legrand software AlphaSoft and transferred to the time switch with the data key Order No. 047 72. 16 for Rex-light example controllers : xxxxxxx for example : xxxxxxx xxxxxxxx AstroRex-twilight time switch xxxxxxxx ■ Deluxe and special functions Relay functions The relay setting can be changed via "MENU" and "FUNCTIONS". The default function is "AUTO", i.e. the time switch switches at the programmed times. Other options available are: "CONST ON", "CONST OFF" and "EXTRA". If "EXTRA" is selected, the switch status specified by the program is reversed. Switch-on and switch-off are controlled by the programmed switching times with the next switching command. Holiday time The start and end time of the holiday period are set in the holiday program and activated with the program item "ACTIVE" or deactivated with the program item "PASSIVE". If the holiday program is active, the time switch will not execute any programmed switch commands during the corresponding period, but remains "CONST ON" or "CONST OFF" as preferred during the holiday period. Upon expiry of the holiday period, the time switch automatically switches in accordance with the programmed switching times. 1 h test The function "1H-TEST" can be used to simulate switching. When the "1H-TEST" is activated, the switch outputs are switched for one hour. At the end of this time, the time switch automatically switches in accordance with the programmed switching times. PIN code Input and programming can be disabled via a four-digit "PIN code". The inhibit can also be cancelled with the "PIN code". The inhibit can additionally be cancelled via the "RESET" function; in this case, all settings and programs are also deleted. Operating hours counter The relay ON time and date of the last reset are displayed. Contrast The display contrast can be adjusted via this function. Delay-time (1-channel AstroRex) The 1-channel AstroRex has a control input with variable delay-time. The control input permits additional switching by the relay in parallel to the switching program. Variable delay-time 0 min - 23 h 59 min; the delay-time begins as soon as the voltage at the control input drops. ■ Data key The menu item "KEY - READ - WRITE" is automatically activated if a data key is inserted when the power supply is connected. "WRITE": Program data are transferred from the time switch to the data key. Important: Data already saved on the data key are overwritten. "READ": Program data are transferred from the data key to the time switch. Any switching programs already saved in the time switch are overwritten. The number of programs in the time switch and the basic settings can be saved in the time switch and on the data key. Example: AstroRex D21 maximum 28 programs plus basic settings. When working without mains voltage, the menu item "KEY - READ - WRITE" is not activated automatically when a data key is inserted. The "KEY" function must be selected via the menu and the required function can then also be executed without mains voltage. ■ PC programming In addition to simple, menu-based programming directly on the time switch, switching programs and basic settings for the AstroRex can also be compiled on a personal computer with the Legrand software AlphaSoft and transferred to the time switch with a data key. A read/write device Order No. 047 73 is needed to transfer switching programs and settings compiled on the personal computer to the data key. The device is connected to the personal computer via the USB port. The read/write device is supplied together with a CD-ROM containing the AlphaSoft program and the necessary driver. System requirements for the personal computer: USB port, Windows® 98 second edition, Windows® 2000 or Windows® XP, 40 MB free memory capacity on the system drive. ■ Reset All data are deleted if all buttons are simultaneously pressed for more than 2 seconds. ter time and switching times as well as other settings must be programmed afresh. Language, date/time, summer / win- 17 for example Rex - digital :time xxxxxxx switches for example : xxxxxxx xxxxxxxx MicroRex Plus MicroRex, xxxxxxxx ■ Technical data Typ No. of modules (17,5 mm) Channels Running reserve Switching step Shortest switching step Accuracy Switching capacity • Resistive 230 V~ cos ϕ=1 • Incandecent lamps 230 V~ • induvtive 230 V~ cos ϕ=0,6 Contacts No. of programs Operating temperature Protection MicroRex D11 1 1 >100 h 2,5 sec/day 1 SPDT 8 MicroRex D21 plus 2 1 MicroRex D22 plus 2 2 6 years 1 min 1 min 1 sec/day 16 A~ 5 A~ 10 A~ 1 SPDT 28 -10....+55 °C IP20 2 SPDT 14/channel ■ Wiring diagram MicroRex D11 1 2 4 3 5 18 MicroRex D21 Plus MicroRex D22 Plus for example Rex - digital :time xxxxxxx switches for example : xxxxxxx xxxxxxxxPlus MaxiRex xxxxxxxx ■ Technical data Typ Channels Running reserve Switching step Shortest switching step Accuracy Switching capacity • resistive 230 V~ cos ϕ=1 • incandecent lamps 230 V~ • inductive 230 V~ cos ϕ=0,6 Contacts No. of programs Operating temperature Protection MaxiRex MaxiRex D72/2 Plus D72/1 Plus 1 2 10 Jahre 1 min 1 min 1 sek/Tag 16 A~ 5 A~ 10 A~ 1 Wechsler 2 Wechsler 28 14/channel -20....+55 °C IP20 Dimensions (mm) 72 110 66 44 69 34 ■ Overview OK MENU ■ How to install DIN-rail Front panel Wall mounting 38 ,4 66 OK MENU 498 32 Ref. 044 09 Ref. 498 32 19 for example Rex - Light sensitive : xxxxxxxswitches for example : xxxxxxx xxxxxxxx D / LuxoRex MicroLux xxxxxxxx ■ Technical data Typ No. of modules (17,5 mm) Channels Running reserve Switching step Min. switching time Accuracy Switching capacity • Resistive 230 V~ cos ϕ=1 • Incandescent lamps 230 V~ • Inductive 230 V~ cos ϕ=0,6 Contacts Programs Light sensivitity Operating temperature Protection of time switch Protection of sensor MicroLux D 2 >100 Std 1 min 1 min 2,5 sec/day 10 A~ 5 A~ 8 A~ 1 SPDT 2-60.000 Lux -10....+55 °C IP20 IP55 LuxoRex 110 A~ 3 A~ 8 A~ 1 SPST 85-1.000 Lux -25....+60 °C IP54 ■ Wiring diagram LuxoRex MicroLux D N L 1 2 7 3 4 20 8 5 max. 50 m for example Rex - analogue : xxxxxxx time switches for example : xxxxxxx xxxxxxxx MicroRex xxxxxxxx ■ Technical data analogue MicroRex Typ MicroRex S11 No. of modules (17,5 mm) Motor Switching dial Running reserve Switching step Min. switching step Switching accuracy Accuracy Switching capacity • Resistive 230 V~ cos ϕ=1 • Incandecent lamp 230 V~ • inductive 230 V~ cos ϕ=0,6 Contact Operating temperature Protection MicroRex MicroRex QT11 W11 1 synchron synchron quarz synchron 1h 24 h 24 h 7d none none >100 h none 37,5 sec 15 min 15 min 2h 37,5 sec 15 min 15 min 2h +/-12 sec +/-5 min +/-5 min +/-30 min according to according to +/- 2,5 sec according to frequency frequency a day frequency 1 SPST MicroRex T11 1 SPST 1 SPST 1 SPST MicroRex QW11 MicroRex T31 MicroRex QT31 MicroRex W31 MicroRex QW31 3 quarz synchron quarz synchron quarz 7f 24 h 24 h 7d 7d >100 h none >100 h none >100 h 2h 15 min 15 min 2h 2h 2h 30 min 30 min 4h 4h +/-30 min +/-5 min +/-5 min +/-30 min +/-30 min +/- 2,5 sec according to +/- 2,5 sec according to +/- 2,5 sec a day frequency a day frequency a day 16 A~ 4 A~ 12 A~ 1 SPST -10....+55 °C IP20 1 SPDT 1 SPDT 1 SPDT 1 SPDT ■ Wiring diagram MicroRex-3 modules MicroRex-1 module Wallmounting plate for MicroRex 31 U1 U2 1 4 2 L Ref. no. 03749 including terminal cover N ■ Technical data analogue MicroRex 31 su/wi Typ Switching dial Running reserve Switching step Min switching time Switching accuracy Accuracy Switching capacity • Resistive cos ϕ=1 • Incandescent lamps 230 V~ • Inductive cos ϕ=0,6 Contacts Operating temerature Protection T31 su/wi W31 su/wi 24 h 7d 5 years 15 min 2h 30 min 4h +/- 5 min +/- 30 min 0,2 sec/ day 16 A~ 4 A~ 12 A~ 1 SPDT -10....+55 °C IP20 ■ Discription of application Automatic summer-/winter time change: the central european changeing dates are programmed into the time switch. Changeing will take place at 02:00h CET. The time switch turns faster to set the new time. Automatic time stetting when installed: as soon as the time switch is connected to tension, the time switch wil set itself automatically to the correct time. Manual setting: The hands of the time switch should not be set manually, because the time switch will then show the wrong time. The internal controler can not be manipulated with changing the hands manually. Eventual wrong displayed times can be corrected with the manual setting of the hands when automatic setting has ended. Reaction of programs during fast setting mode: during the fast setting mode the choosen programs will be executed faster than normal. ■ Explanation of the LED LED is OFF: there is no tension connected to the time switch or when time switch is connected, the time switch is in automatic setting mode. LED is ON The automatic setting has ended. Automatic summer/winter change is activated. Wrong displayed time can be manually adjusted. LED is flashing The automatic summer winter change is irreversibel defective. The time switch will work without running reserve like a common quarz controlled time switch. Only manual setting is possible. 21 for example Rex - analogue : xxxxxxx time switches for example : xxxxxxx xxxxxxxx MaxiRex xxxxxxxx ■ Technical data Typ Motor Switching dial Running reserve Switching step Min. switching step Switching accuracy Accuracy Switching capacity • Resistive 230 V~ cos ϕ=1 • Incandescent 230 V~ • Inductive 230 V~ cos ϕ=0,6 Contacts Operationg temerature Protection MaxiRex T synchron MaxiRex QT quarz 24 h none >100 h 10 min 30 min +/-5 min according +/-2,5 sec to freqency a day 1 Wechsler 1 Wechsler MaxiRex MaxiRex TT QTT synchron quarz 24 h/24 h none >100 h 10 min/15 min 30/45 min +/-5 min according +/-2,5 sec to freqency a day 2 Wechsler Wechsler MaxiRex W synchron MaxiRex QW quarz 7d none >100 h 1h 3h +/-30 min according +/-2,5 sec to freqency a day 16 A~ 4 A~ 12 A~ 1 Wechsler 1 Wechsler -10....+55 °C IP20 MaxiRex MaxiRex WT QWT synchron quarz 7 d/24 h none >100 h 1 h/15 min 3 h/45 min +/-30/5 min according +/-2,5 sec to freqency a day 2 Wechsler 2 Wechsler Dimensions (mm) 72 ■ How to install DIN-rail Front panel Wall mounting 6,4 38 6 Ref. 044 09 22 Ref. 498 32 MaxiRex TS synchron 24 h/60 min none 10 min/37,5sec 30 min/1,25 min +/-5min/12,5sek according to freqency 2 Wechsler Rex - analogue time switches for example : xxxxxxx EconoRex B for example : xxxxxxx xxxxxxxx xxxxxxxx ■ Technical data Typ EconoRex EconoRex EconoRex EconoRex Motor BT AP synchron BW AP quarz BQT AP synchron BQW AP quarz Switching dial Running reserve Switching step Min. switching time Switching accuracy 24 h none 7d >100 h none >100 h 2h 2h +/-30 min according +/- 2,5 sec 15 min 15 min +/-5 min according +/- 2,5 sec Accuracy Switching capacity • Resistive 230 V~ cos ϕ=1 • Incandescent lamps 230 V~ • Inductive 230 V~ cos ϕ=0,6 Contacts Operating temperature Protection to frequency a day to frequency 16 A~ 4 A~ 8 A~ a day 16 A~ 4 A~ 8 A~ 1 SPDT -10....+55 °C IP30 Dimensions (mm) ■ Wiring diagram 72 Ø7,5 35,5 31,8 100,5 72 54 Ø3,5 U1 U2 1 2 4 L 48,8 27 N ■ How to mount Wall mounting DIN-rail Ref. 044 07 23 Rex - analogue time switches for example : xxxxxxx EconoRex M for example : xxxxxxx xxxxxxxx xxxxxxxx ■ Technical data Typ EconoRex MT synchron Motor Switching dial Running reserve Switching step Min. switching time Switching accuracy Accuracy Switching capacity • Resistive 230 V~ cos ϕ=1 • Incandescent lamps 230 V~ • Inductive 230 V~ cos ϕ=0,6 Contacts Operating temperature Protection EconoRex MQT quarz EconoRex MW synchron 24 h none EconoRex MQW quarz 7d >100 h 10 min 20 min +/-5 min according +/-2,5 sec to frequency a day none >100 h 1h 2h +/-30 min according +/-2,5 sec to frequency a day 20 A~ 4 A~ 12 A~ 16 A~ 4 A~ 12 A~ 1 SDPDT -10....+55 °C IP30 ■ Wiring diagram U1U2 2 4 1 Isolierung 6,3 x 0,8 2 2,5mm (I > 16A) L N ■ Overview ■ How to mount Wall mounting 38 54 Front panel R3 68 +0,7 ,4 +0 69 54 24 Ref. 495 94 Rex - analogue time switches for example : xxxxxxx PolarRex for example : xxxxxxx xxxxxxxx xxxxxxxx ■ Technical data Typ PolarRex PolarRex KT QKT synchronous quarz Motor Switching dial Running reserve Switching step PolarRex PolarRex KKT QKKT synchronous Quarz 24 h none >100 h none >100 h 30 min Min. switching time Switching accuracy (switching dial) Accuracy Switching capacity • Resistive 230 V~ cos ϕ=1 • Inductive 230 V~ cos ϕ=0,6 Contacts Operating temperature Protection according to frequency 1-60 min +/-5 min +/-1 sec according to a day frequency +/-1 sec a day 16 A~ used as NO: 4 A~/used as NC 12 A~ 1 SPDT 2 SPDT -10....+55 °C IP 30 ■ Wiring diagram Dimensions (mm) 72 53,4 20 22 12 16 14 3 10 7 6 5 4 5 1 1 5 30 60 1 13.7 30 60 113,7 min. 8 10 6 9 min. 10 3 2 11 72 1 9 13 12 24 23 19 18 17 15 21 2 1 STOP 2 L N 1 2 3 4 5 6 N L 44,4 ■ How to mount Wall mounting DIN-rail 28,5 89 3,5 x 40 60 10 1 60 30 60 1 5 30 5 1 5 10 30 60 1 5 30 10 10 3,5 x 30 ■ Programming Programming the defrost times and visualisation of the working status with 2 green LED’s 25 Rex - staircase timers for example : xxxxxxx Rex800 Plus Rex - staircase timers for example : xxxxxxx RexEM Plus/Rex600 Plus xxxxxxxx xxxxxxxx ■ Wiring diagram Rex800 Plus 3-wire connection ■ Wiring diagram 4-wire connection 3-wire connection RexEM Plus N B A2 B N B N B L 4 N B L 4 230 V ~ 50/60Hz 230 V ~ 50/60Hz A2 B A1 4 A1 4 L N L N L N L N 230 V ~ N B N B N B L 4 N B L 4 3-wire connection Rex600 Plus L N L N 230 V ~ 50/60Hz 230 V ~ 50/60Hz L N 230V ~ 50/60Hz L ■ Pre-warning function according to DIN 18015-2 ON OFF OFF 4 L L N 0,5...12 min. 230 V ~ 50/60Hz 0,3 s 5s 0,3 s 20 s L N 230 V ~ 50/60Hz B N L B N 4 N B N B Diagram 1: without pre-warning ON OFF 0,5...12 min 5s 20 s 5s 20 s ON Diagram 2: with pre-warning 0,5...12 min ON OFF 0,3 s 26 L N 3-wire connection Rex600 Plus For renovation only! 0,5...12 min. ON Standard setting: with early warning function (diagram 2). Manual change possible useing the button on the right side of the device. 0,5...12 min 0,3 s 4-wire connection RexEM Plus 230 V ~ Rex - staircase timers for example : xxxxxxx Rex800 Multi for example : xxxxxxx xxxxxxxx xxxxxxxx ■ Wiring diagram 3-wire connection 4-wire connection NB NB S- S+ S- S+ Functions E and F can not be used in houses with flats! L 4 L 4 230 V~ Attention: standard setting is fuction B L N L 230 V~ N 8 - 230 V ≅ 8 - 230 V ≅ ■ Selectable functions A B/S-/S+ 0,5...12 min. ON B/S-/S+ A OFF 0,5 - 12 min ON OFF B B/S-/S+ 0,5 - 12 min ON OFF C B/S-/S+ 0,5 - 12 min 1h ON OFF D B 230V~ B/S-/S+ 0,5...12 min. 5s 20 s L N B/S-/S+ 0,5 - 12 min 1h B/S-/S+ SS+ 8V 230V ≅ ON 0,5 - 12 min E ON OFF B/S-/S+ 0,5 - 12 min F ON OFF OFF 0,3 s C D E F B A G B/S-/S+ G 0,3 s 230V~ ON OFF L N C D E F B A G SS+ 8V 230V ≅ C >2s >2s <2s B/S-/S+ 0,5...12 min. 1h ON OFF > 2s < 2s D > 2s B/S-/S+ 0,5...12 min. 5s 20s 1h 5s 20s ON OFF 0,3 s E 0,3 s 0,3 s 0,3 s B/S-/S+ 0,5...12 min. ON OFF F B/S-/S+ 0,5...12 min. 5s 5s 20 s 20 s ON OFF 0,3 s 0,3 s G B/S-/S+ ON OFF 27 for example Rex - analogue : xxxxxxx time relays for example : xxxxxxx xxxxxxxx xxxxxxxx ■ Technical data Typ No. of modules (17,5 mm) Supply voltage Power consumption Precision of const. parameters Setting accuracy Switching capacity • Resistive 230 V cos ϕ=1 • Incandescent lamps 230 V • Inductive 230 V cos ϕ=0,6 Contacts No. of cycles Max. admissible length of control wire Operating temperature Protection ■ Wiring diagram Time relays 1 12....230 V AC/DC ca. 2 W +/- 0,2% of adjusted value +/-5% at 25 °C 8 A~ 2 A~ 4 A~ 1 Wechsler 105 switchings at 2000 VA 107 mechanical switchings 20 m -20....+60 °C IP20 ■ 7 domains of time: min. 0,1 s – 1s – 10 s – 1 min. – 10 min. – 1h – 10 h – max. 1s 10 s 100 s 10 min. 100 min. 10 h 100 h ■ Functions and switching diagrams ON-delay relay 047 40 Multifunctional relay 047 44 additionally to the previous mentioned functions, (except flashing relay) the multifunctional relay offer the following functions: ON/OFF delay Control input Y1 Control input Y1 Contact Contact OFF-delay 047 41 Flasher (impulse starting Control input Y1 Control input Y1 Contact Contact Clock generator relay 047 43 Flasher (OFF-time starting) Control input Y1 Control input Y1 Contact Contact Impulse former relay 047 45 Passing contact Control input Y1 Control input Y1 Contact Contact Flashing relay 047 42 Additive ON delay Control input Y1 Control input Y1 Contact Contact Additive fleeting ON Control input Y1 Contact 28 for example Rex - Hour counters : xxxxxxx for example : xxxxxxx xxxxxxxx ContaRex xxxxxxxx Dimensions (mm) Dimensions (mm) 6x 2,54 ca. 25 7,5 41,3 ContaRex 48x48 0,64 3,9 45 1 2 3 4 5 6 7 32 48 6 32 ■ Wiring diagram 1 and 2 channel 1 channel with control entry U1 0006723 h LCD UB Tasten 3 Kanal 1 5 2 Kanal 2 6 1 Steuereingang max. 3,5V 5V z.B. 750Ω 3 ContaRex ø 80mm z.B. Li-Zelle 3V z.B. Speicherkondensator max 3,5V 2 71+1 3V3 1 channel with radio control U1 51 80 18 LCD Tasten 3 Kanal 1 UB 5 MC 2 6 ContaRex 36x24 Komparator DCF77DCF77+ 7 ca. 5V z.B. 750Ω 22x33 24 4 z.B. Li-Zelle 3V z.B. Speicherkondensator max 3,5V 3,3V 36 8 55 29