WITH A HOT DAWG.

Transcription

WITH A HOT DAWG.
TAKE THE CHILL OUT OF
YOUR GARAGE OR WORKSPACE
WITH A HOT DAWG.
®
2
HOT DAWG® H2O LOW PROFILE HOT
WATER UNIT HEATER (MODEL HHD)
HOT DAWG® POWER-EXHAUSTED,
GAS-FIRED UNIT HEATER (MODEL HD)
• Hush-puppy
• No
external moving parts - twin centrifugal
blowers keep all moving parts inside the cabinet
quiet operation (see table)
• Right
or left hand controls available on all 30-75
units. Gas, electrical and flue connections can be changed by simply flipping the Hot Dawg over
• Uses
flexibility (parallel, perpendicular
or recessed between joists) allows for horizontal
or vertical air delivery
natural or propane gas
• Lightweight,
easily installs 1” from ceiling with
only two angle brackets (included on sizes
30-75, accessory for 100, 125)
• Full
• Mounting
• Low-profile
• Available
design
in hammertone beige
• Constructed
of heavy gauge steel for clean
appearance and maximum headroom
10-year warranty on heat exchanger
• Standard
• Includes
• Permanently-lubricated
• Internal
two mounting brackets with vibration
isolators to reduce noise and vibration
power exhaust simplifies side-wall
or roof venting with small-diameter vent pipe
coil can handle water pressures
up to 150 PSI and temperatures up to 200° F
motor for
trouble-free dependability
• Controls
can be either single or two-stage, direct spark ignition, 100% shut-off
with continuous retry
Hot Dawg H20 Applications
• Low-profile
design and neutral color to blend
in with decor
• Also
available with a blower (model HDB). Contact Modine for further information
Hot Dawg Applications
Model
Btu/Hr Input
Typical Application
HD/HDS 30
30,000
1 to 1-1/2 Car Garage
HD/HDS 45
45,000
2 to 2-1/2 Car Garage
HD/HDS 60
60,000
3 to 3-1/2 Car Garage
HD/HDS 75, 100, 125
75,000-125,000
Large Garage
*Sizing data for sample only. Consult a qualified installer for the actual requirements
for your building.
Model Sizes
Airflow
(CFM)
GPM
140° F
BTU/hr
180° F
BTU/hr
Application
HHD 30
405
405
2
4
20,600
24,200
30,900
36,300
1 to 2 car garage
HHD 45 (high speed)
710
710
2
4
29,900
35,100
44,800
52,700
2 to 3 car garage
HHD 45 (low speed)
425
425
2
4
20,700
24,400
31,100
36,600
2 to 3 car garage
Model HD/HDS Sound Pressure Level (dBA)1
Model
Size
Modine
Competitor2
5 ft.
5 ft.
30
53
59
45
57
59
60
59
59
75
58
69
1. Measured at distance from unit shown.
2. Competitor published data.
93%
Efficient
* Requires a 40 degree ambient temperature at all times
and access to a drain for condensate
EFFINITY 93® CONDENSING UNIT HEATER
(MODEL PTC)
HOT DAWG® SEPARATED COMBUSTION
GAS-FIRED UNIT HEATER (MODEL HDS)
Same features as HD, with these added benefits:
Looking for the most efficient unit?
All model sizes operate at 93% efficiency, making
it the most efficient gas-fired, condensing unit
heater in North America
• Draws
combustion air from outside the
work space, ensuring the unit always
has plenty of fresh, clean air to breathe
• The
fresh air supply reduces common
concerns about dusty, dirty or humid applications, providing greater durability
and reduced maintenance
All sizes are separated combustion
• Factory
assembled, certified separated combustion saves installation time
Performance Data - Model HD/HDS
Model Size
30
45
60
75
100
125
Btu/Hr Input
30,000 45,000 60,000 75,000 100,000 125,000
Btu/Hr Output1
24,000 36,000 48,000 60,000
1
Features Modine’s high-grade stainless steel
Conservicore® technology secondary heat exchanger
80,000
100,000
Entering Airflow (CFM)2
505
720
990
1,160
1,490
1,980
Outlet Velocity
The standard Contractor Convenience Package allows for easy connectivity and troubleshooting
with a factory mounted disconnect switch, external
operating lights and convienience outlet
A minimum 15% decrease in C02 versus other gas-fired heaters and minimum 17% gas savings
(up to 40%)
A smart investment and respectable ROI with valuable state utility rebates available
523
749
653
769
565
747
Air Temp. Rise (ºF)
44
46
45
48
50
47
Performance Data - Model PTC
Mounting Height (Max ft.) 2
10
10
12
14
12
16
Model size
55
Heat Throw (ft.)
25
27
36
38
42
56
Btu/Hr Input ➀
55,000
65,000 85,000 110,000
Btu/Hr Output1
51,150
60,450 79,050 102,300
2
1
65
85
110
Condensate Production (Gal./Hr.)
0.3
0.4
0.5
0.7
Entering Airflow (CFM) @ 70°F2
1,097
1,141
1,650
1,750
Outlet Velocity (FPM)2
618
650
619
668
Air Temp. Rise (°F)
43
49
44
54
Max. Mounting Height (Ft.)2
12
12
13
13
Heat Throw (Ft.) @ Max. Mtg Ht
43
43
48
46
1. Ratings shown are for elevations up to 2,000 ft. For elevations above 2,000 feet, ratings should be
reduced at the rate of 4% for each 1,000 feet about sea level. (In Canada see rating plate.)
Reduction of ratings requires use of high altitude kit.
2. Data taken at 65ºF ambient and unit fired at full-rated input. Mounting height as measured from
bottom of unit, and without deflector hoods.
ˆ
RESIDENTIALLY-CERTIFIED, gas-fired unit heater specifications
A
B
E
(OPENING)
Performance
30
Model Size
P
Air Temp. Rise (°F)
44
46
45
48
50
47
E
56
G
1,550
Gas Connection
25
3.7
2.4
3.7
38
1/12
1,625
1,625
1,050
1.2
2.7
P.S.C.
P.S.C.
3.7
2.5
2.5
1.2
1/12
D
H(APPROX.)
(APPROX.) 14.9
(APPROX.)
CR
F
7.25
H
1/8
S.P.
P.S.C.
4.7
4.2
S.P.
P.S.C.
3.7
2.5
2.4
1.2
2.7
I
3
K (HDS only)
Control Options
L (HDS only)
22
22
3/4*
2.74
2.74
3.19
3.19
1/2
1/2
34.5
3.15
3/4*
3.15
25
5.55
60
80
31.0
8.4
1/2
43.0
25
31.0
3.87
5.55
4
85
125
Clearances
Clearance To
Combustible Materials
33.50
35.00
31.50
29.50
27.50
25.50
Clearances for Residentially-Certified
Unit Heaters
Top and Bottom
1"
23.50
SIZES
100/125
(ACCESSORY)
21.50
13.50
11.50
Unit Side
Unit Side
ons
Access Side
Clearance To Combustible
Rear
Materials 18"
Vent Connector
4"
Top and Bottom
Control Description
Access Side
Spark Ignition, 100% Shut-Off with Continuous Retry
e combination gas control with ignition control.
spark igniter on call for heat.
Non-Access Side
Rear
park Ignition, 100% Shut-Off with Continuous Retry
combination gas control with built-in ignition control.
nd 50% of full rated input. Gas is lit with a direct spark
t.
Vent Connector
1"
Non-Access Side
Service
Voltage
11
115V
1"
1"
18"
1"
Recommended
Service
18"
Clearance
4"
21
115V
12
115V
22
115V
7.835
34.5
34.5
1/2
55
1/2
65
85
110
31.0
29.80
35.53
35.53
3.19
3.19
5.55
5.55
10.73
3
3
3/4*
3/4*
4
18.13
20.31
20.31
28.19
33.83
33.83
14
18.0
3
3
3
22
22
2.74
2.74
B
C3
25
3.15
3
Combustion Air
55
60
Inlet Pipe
10
10
4
14
80
25
29.80
8.4
1/2
43.0
3.15
18.13
28.19
4
85
3
3.87
4
125
Unit Side
Top and Bottom
Access Side
Non-Access Side
Rear
Vent Outlet Pipe
Clearance To
Gas
Connection
Combustible
Materials
1"
Approx. Shipping
1"
1"
Weight (lbs.)
18"
3
Recommended
Service Clearance
1/2
3
3
3
1/2
1/2
1/2
103
125
128
1"
9318"
1"
18"
4"
4" work.
➀ 1. Do not use propeller
units with duct
Vent Connector
Control
Code No.
Service
Voltage
Thermostat
Type of
Model
30-125
For
more information
on the Effinity93,
Voltage
Gas
Size
24V www.ModineHVAC.com/Effinity93
natural
30-125
visit
11
115V
21
115V
24V
propane
12
115V
24V
natural
75-125
22
115V
24V
propane
75-125
Hot Dawg H2O Mounting Flexibility
2
1”
Thermostat
Voltage
Type of
Gas
Model
Size
24V
natural
30-125
24V
propane
30-125
natural
75-125
1”
1”
7.835
Recommended
Service Clearance
1”
Control
Code No.
7.6
34.5
14.0
10.73
Direct
Spark
Ignition,
* 3"Two-Stage,
for Model HD,
4" for
Model
HDS 100% Shut-Off with Continuous Retry
- Utilizes a two-stage combination gas control with built-in ignition control.
Firing rate is 100% and 50% of full rated input. Gas is lit with a direct spark
igniter on call for heat.
25.10
26.20
23.10
21.10
19.10
17.10
9.10
7.10
SIZES
30-75
Clearances
20.5
3
3
3/4*
3/4*
4
Vent Connector Size (in.)
Control Description
Combustion Air Inlet Connector
3
3
4
4
4
Size (Model HDS only) (in.)
Single-Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry
- Utilizes
a single-stage
ignition 14
control. 18.0
Fan
Diameter combination
10gas control
10 with14
Gas is lit with a direct spark igniter on call for heat.
Approx. Shipping Weight (lbs.)
55
60
80
85
125
55
7.6
Approx. Shipping Weight (lbs.)
18.4
1/2
22.5
18.4
FAN
FAN
CONDENSATE DRAIN
DRAIN
CONDENSATE
F
3/4" PVC
PVC
CONDENSATE DRAIN
DRAIN 3/4"
CONDENSATE
3/4" PVC
PVC
3/4"
G
D (OPENING)
H
D (OPENING)
* 3" for Model HD, 4" for Model HDS
24.0
1/2
34.5
Fan Diameter
14.0
18.5
14.9
15.9
34.5
Combustion Air Inlet Connector
Size (Model HDS only) (in.)
22.5
15.9
22.0
10.75
A
J
35.5
25.10
26.20
25
7.835
18.5
23.10
7.835
21.10
26.8
14.9
18.0
10.75
15.9
22.0
14.9
15.9
35.5
20.5
FAN
FAN
16.5
10.75
1/2 size1/2
Model
L (HDS only)
33.50
35.00
1/234.5
14.9
10.75
19.10
9.10
34.5
16.5
31.50
25
100/125
14.9
10.1
100/125
Dimensions
Model24.0PTC1➀
18.5 (inches)
18.5
18.5 - 18.5
K (HDS only)
35.5
20.5
29.50
18.5
18.5
SIZES 7.6
7.6
100/125
1/2
1/2
(ACCESSORY)
16.5
27.50
1/2
J
3
10.1
18.0
7.25
7.25
26.8
7518.0
25.50
22
26.8
10.1
17.10
H
G
1/2
2.2
Approx. Shipping
Weight (lbs.)
12.2
26.8
18.0
23.50
Gas
P.S.C.Connection
S.P.
P.S.C.
1.2
F
Gas Connection
1,550
Vent Connector
(in.)
2.5
4.7 Size4.2
26.8
7.10
22
E
5.10
1/8
56
C1/12
1,050
D
3.10
12.2
16.5
16.5
SIZES
14.9
30-75 14.9
21.50
42
26.8
16
13.50
38
1/12
1,625
747
26.8
6012.2
16.5
75
26.8
18.0
7.25
Vent Connector Size (in.)
26.8
16.5
10.1
I
2.2
26.8
18.0
H(APPROX.)
(APPROX.)
(APPROX.)
CR
16
42
1/12
60
26.8
12.2
16.5
747
12
S.P.
12.2
11.50
36
1/12
1,625
47
B12
14
9.50
27
1/15
1,550
50
A565
769
7.50
12
C
.00
1.10
48
653
10
1,980
5.50
45
2.4
2.4
45
B
3.50
46
749
1,490
A
30
.00
1.50
44
S.P.
36
1,550
565
14
1” - angle,
mounting
brackets30are slotted
to60accommodate
joists
Model
Size
45
75
100/125
60
75
100 (inches)
125
Dimensions
- Model
HD/HDS
on 16” or 24” centerlines.
1,160
25
27
1/15
S.P.
769
12
1,550
Type
Amps
Unit Total Amps
990
1/15
653
10
1/15
RPM
Motor
Data
720
1,550
C C
1,980
749
45
26.8
1,490
Horsepower
505
12.2
C
1,160
10
Model Size
30
B
A
990
523
24,000 36,000 48,000 60,000 80,000 100,000
Model Size
720
Outlet Velocity
30,000 45,000 60,000 75,000 100,000 125,000
10
Dimensions (inches)
125
Mounting
Dimensions (inches)
45
523
100
505
Heat Throw (ft.)
30
75
18” 24V
1
4”/6” 24V
propane
18”
1”/18”1
Horizontal air delivery; perpendicular to joists
18”
4”/6”1
75-125
➀ 1. For high-efficiency unit only (Model PTC)
To find out where to buy a Hot Dawg,
visit www.ModineHVAC.com/HotDawg
Vertical air delivery; recessed between joists
Horizontal air delivery; parallel to joists
Modine Manufacturing Company
1500 DeKoven Avenue
Racine, Wisconsin 53403-2552
1.800.828.HEAT
www.ModineHVAC.com
Follow us on Twitter @ModineHVAC
©2013 Modine Manufacturing Co.
6-114.8
ACCESS
ACCESS
PANEL
PANEL
M
M
COMBUSTION
COMBUSTION
AIR INLET
INLET
COMBUSTION AIR
COMBUSTION
AIR INLET
INLET
AIR
VENT
VENT
OUTLET
OUTLET
VENT
VENT
OUTLET
OUTLET
GAS
GAS
CONN.
L
CONN.
GAS
GAS
CONN.
L
CONN.
K
K
J
J
B
B
B
B
Entering Airflow (CFM)
Mounting Height (Max ft.)
C (APPROX.)
C
60
24,000 36,000 48,000 60,000 80,000 100,000
Btu/Hr Output
COMBUSTION AIR
LOUVERS (HD ONLY)
45
E
(OPENING)
30,000 45,000 60,000 75,000 100,000 125,000
Btu/Hr Input
B
A
ng brackets are slotted to accommodate joists
* 3” for Model HD, 4” for Model HDS
erlines.
5.10
A
A
A
C (APPROX.)
C
t.)
9.50
N
P
N
KNOCKOUTS FOR
FOR
KNOCKOUTS
SUPPLY POWER
POWER WIRING
WIRING
SUPPLY
KNOCKOUTS FOR
FOR
KNOCKOUTS
CONDUIT ENTRANCE
ENTRANCE
CONDUIT
SUPPLY POWER
POWER WIRING
WIRING
SUPPLY
CONDUIT ENTRANCE
ENTRANCE
CONDUIT
A
A
A
ACCESS
ACCESS
PANEL
PANEL
)
er
ADJUSTABLE
LOUVERS
COMBUSTION AIR
LOUVERS (HD ONLY)
ADJUSTABLE
Q (MINIMUM DISTANCE TO WALL)
LOUVERS
Q (MINIMUM DISTANCE TO WALL)
3.56
14.90
(4) 3/8"-16 MTG HOLES
3.56
14.90
(4) 3/8"-16 MTG HOLES
For Hot Dawg H2O specifications,
visit www.ModineHVAC.com/HotDawg
I
F
G
H
I