EVOLVE® True Definitive Care for BPH.

Transcription

EVOLVE® True Definitive Care for BPH.
EVOLVE
EVOLVE
®
True Definitive Care
for BPH.
®
The future of BPH treatment has come to the office.
www.biolitec.com
LIFE™
Procedure
Laser Induced Flow Enhancement procedure for BPH treatment.
True Definitive Care for BPH
LIFE Laser Induced Flow Enhancement is much more than a laser system.
LIFE is a simple and effective process for bringing true definitive care to BPH.
The LIFE Procedure incorporates both our EVOLVE® Laser System and our patented
side-fire fiber: FUSION.™ The combined result is a minimally invasive procedure with
enhanced patient benefits such as quick recovery, local anesthesia and minimal
post-treatment side effects or discomfort.
LIFE provides a better patient experience through
a number of advanced features and benefits:
- Minimal post-treatment discomfort or side effects
- Option of local anesthesia in an office setting
- Quick recovery
- Limited or no need for post-op catheterization
- No hospitalization post-op required
- Office visit co-pay versus hospital deductible
Low Risk of Complications: - Can greatly reduce the possibility of retrograde ejaculation
- In most cases, there is no impact on sexual performance
or continence
- Wavelength is ideal for vaporization and hemostasis
Clinical Result:
pre-operative
post-operative
“The operation, performed with the Evolve 980nm laser, can be rightly considered a
breakthrough in the treatment of BPH as it achieved an unobstruction comparable to
TURP while preserving sexual performance and ensuring normal anterograde ejaculation.”
Source: R. Leonardi Manuscript Number: EURUROL-D-08-00245 SLV WITH DIODE LASER 980nm AND PRESERVATION OF ANTEROGRADE EJACULATION PERSONAL TECHNIQUE
Selective Laser Vaporization (SLV)
10.000
1.000
10
1
532
0.01
2100
0.1
980
Absorption (cm-1)
100
0.001
0.0001
Wavelength (nm) 980nm is 2300 times more absorbed in H2O than 532nm
532nm is 74 times more absorbed in HBO2 than 980nm
Ex-vivo Evaluation of EVOLVE®
5 minutes
10 minutes
15 minutes
EVOLVE® 120
EVOLVE® 80
EVOLVE® 100
KTP-Laser 80
EVOLVE® 120
TURP
KTP-Laser 80
TURP
Source: Wendt-Nordahl G, et al., 980-nm Diode Laser: A Novel Laser Technology for Vaporization of the Prostate, Eur Urol (2007), doi:10.1016/j.eururo.2007.06.029
EVOLVE
®
A Complete Procedural System
150 Laser Syste
EVOLVE® Laser System · FUSION™ Fiber
The EVOLVE Laser is used to vaporize and remove the obstructing prostate tissue
that causes the symptoms associated with BPH. The 980nm wavelength of the
EVOLVE Laser combined with the FUSION Fiber precisely eliminates the obstruction
while causing no damage to the surrounding tissue. This leads to a more rapid
recovery with less post-op discomfort compared to traditional surgery.
Tissue Interaction
The 980nm wavelength of the EVOLVE Laser System provides the highest
combined absorption in water and hemoglobin. Since the prostate contains
a high percentage of water, the EVOLVE Laser vaporizes tissue effectively.
Absorption of the laser energy by hemoglobin leads to excellent hemostasis
combined with precise ablation of the obstructing tissue.
EVOLVE 150 Laser System
The World’s Most Powerful Medical Laser System:
For unmatched performance in speed and effectiveness
Mobile Unit or Portable System:
Depending on the setup of your practice, you can choose between the portable laser
system or a complete mobile unit with additional light, camera module and monitor
Extremely Quiet:
Noise is an unwanted distraction in endourological ORs, our EVOLVE Laser System
allows you to work in a quiet environment
Automatic Fiber Type Recognition:
The maximum output is based on the connected fiber. The laser detects and protects
the fiber type by maintaining secured output parameters (RFID technique)
Auto-Memory Function:
Operating the EVOLVE Laser System is further simplified by automatically storing
the last parameter settings used, ensuring both operator and patient safety
Interdisciplinary Use:
Due to EVOLVE’s small footprint and its light weight, the LIFE™ Procedure can easily be
incorporated into a mixed-device/mixed-procedure environment within surgical centers
Excellent Visualization:
The wavelength of the EVOLVE diode laser is invisible to the human eye and does not
impair your vision during a procedure. The resulting lack of distraction makes it easier
to operate with precision in a stress-free environment
Minimal Maintenance Costs:
Thanks to the long life and trouble-free characteristics of biolitec’s laser diode
technology, high maintenance costs are things of the past
em
Specifications:
Laser type: diode laser
Wavelength: 980nm
Treatment mode: continuous-wave or pulsed
Pulse duration: 0.01 – 99.9 sec
Output: up to150 Watts
Aiming beam: 635nm – 4mW
Cooling: air
Dimensions: 22Wx12D x 12H (in); 56W x 30D x 30H (cm)
Weight: 66.1 lbs (30 kg)
Power supply: 220 V / 110 V, 50/60 Hz
FUSION
Fiber
70° forward deflection for high ablation
rates for vaporization of tissue.
FUSION Fiber
Designed specifically with a patented fused
cap and unique side-fire feature for soft
tissue urological procedures, FUSION Fiber
offers unsurpassed performance, reliability
and convenience.
- Uniform 600 µm fiber with a 1.95 mm outside diameter enables maximum performance in
conjunction with the EVOLVE Laser System
- Dual indicator lines provide easy visualization
for precise targeting of the laser beam
Visible aiming beam for precise control
of the laser beam.
Rugged construction.
- Special silica window protects the working tip
- Unique hand-positioning knob facilitates easy
reference to beam direction
A solid orange indicator line located
180° from the exit beam. A solid black
indicator line located at the exit beam.
Dual indicator lines allow for better
positioning of the fiber.
Retraction indicator lines for scope safety.
Comparison of Laser Systems
on the Urology Market
EVOLVE
KTP
Ho:YAG
Wavelength 980nm
Wavelength 532nm
Wavelength 2100nm
Highest combined absorption
in water and hemoglobin
Selectively absorbed in hemoglobin
Selectively absorbed in water
Selective Light Vaporization
(SLV) – perfect combination
of contact vaporization
and hemostasis
Non-contact vaporization of soft
and vascular tissue. No other
indications are possible.
Non-contact ablation through
vapor bubbles
Excellent hemostasis ensures
minimal post-operative bleeding
and preservation of surrounding
tissue for a quick recovery
Resulting heat induces a small
coagulation zone
Moderate hemostasis requires
post-operative catheterization
and can lead to intra-operative
bleeding
Tissue removal is superficial,
allows for precise cuts, but
slow vaporization
The benefits of biolitec’s EVOLVE® technology extend well beyond BPH treatment:
Bladder Tumors
Bladder Neck Condyloma
Urethra Strictures
External Genital Lesions such as Condyloma
biolitec AG
Winzerlaer Straße 2 · D-07745 Jena, Germany
Phone: +49 36 41 50 85 50 · Fax: +49 36 41 50 85 99
E-Mail: info@biolitec.de · http://www.biolitec.de
biolitec Inc.
515 A Shaker Road · East Longmeadow, MA 01028, USA
Phone: +800 934 2377 · Fax: +1 413 525 0611
E-Mail: info@biolitec-us.com · http://www.biolitec-us.com
biolitec Italia SRL
Viale Monza 133 · 20123 Milano, Italy
Phone: +39 02 28 17 2 400 · Fax: +39 02 28 17 2 299
E-Mail: info@biolitec.it · http://www.biolitec.com
biolitec (M) Sdn. Bhd.
No. 18, Jalan PJS. 7/21 · Bandar Sunway · 46150 Petaling Jaya, Selangor D.E., Malaysia
Phone: +603 56 32 71 28 · Fax: +603 56 38 01 28
E-Mail: info@biolitec.com.my · http://www.biolitec.com
biolitec India Pvt. Ltd.
603/604, Carlton Towers, Airport Road · Bangalore-8, India
Phone: + 91 80 4148 2050
E-Mail: info@biolitec.com · http://www.biolitec.com
biolitec FZ LLC
B/P 49 Unit 306 · P.O. Box 505072 · Dubai Healthcare City · United Arab Emirates
Phone: +97 1507946118
biolitec, SIA
Kaniera iela 10a · Riga, LV-1063 · Latvia
Phone: + 371 53 43 646 · Fax: + 371 53 07 210
E-mail: info.lv@biolitec.com · http://www.biolitec.com
EVOLVE® is a registered trademark of biolitec, Inc.
ML- 294 05/08
www.biolitec.com

Similar documents